AWG 20/19/32 Silver Plated Conductor, PTFE Insulated Type 'E' 600 V AC, Blue Color AWG 20/19/32 Silver Plated Conductor, PTFE Insulated Type 'E' 600 V AC, Blue Color 2019EB GTP/ Customer Specs. No.

Description Conductor

Parameter Material Overall Diameter of Strand No of strands Conductor Diameter Cross-Sectional Area Conductor Resistance (max) Elongation -

Unit

Specified Value Silver Plated Copper 0.2 19 1.01 0.62 29.1 13.5(before stranding) Core complies with the requirements of U.S. Military Specification MIL-W-16878/21 E 0.25 1.51 OK OK OK OK OK OK OK Passed - OK Passed - OK Passed - OK Passed - OK Page No. 1 of 1

mm (nom) nos mm (nom) Sqmm (max) /km at 20deg.oC % (min) PTFE, Tape Wrapped & Sintered mm (nom) mm (nom) mm (nom) mm (nom) Unit mm (nom) mm (nom) mm (nom) 1 Second at 5.0 KV 1 Minute at 3.0 KV 1 Meter from each end of Wires /km at 20deg.oC

Insulation Material Insulation Type Thickness Dia of core Gauge/Size Conductor Diameter Number of Strands Strand Diameter Core Insulation Core Diameter at Final Stage Color Sequence & Lay Spark Test Dielectric Test

Physical Test

Electrical Test (Before Twisting on Cores, 100% Length in Water BDV on Cores Tank)

DC Resistance at 20 C Prepared & Checked by :

Checked & Approved By Manoj Agarwal

Reference International
ASTM B 3, ASTM B 8, ASTM B 787, IEC 228 (1978)

Reference Domestic

886226947319.00 886-2-22992121