STRIPPING COLUMN AIR REQUIRMENT INPUT Flow rate (M3/d) Inlet Conc (ppm) M. W.

OUTPUT Na in (moles of A) Co (molesof A/moles of water) Ye (moles of A/moles of air) G/L (moles of air/moles of water) Air (liter) Water (liter) G/L (Liter) G (M3/d)

1200 30 34

50 m3/hr

0.000882 1.59E-05 1.19E-05 1.333333 32.13333 0.018 1785.185 2142222 89259.259 m3/hr

DETERMANATION OF DIAMETER INPUT PACKING Pacing factor Assum striping factor (s) prssure drop

130 4

OUT PUT S=(G'/L')*(H/P) L'/G' X axis value put y axis value G' (kg/m2 sec) L' (kg/m2 sec) D (m)

1.208333 3.310345 0.114934 0.04 0.860251 2.847726 2.492584

DETERMINATION OF HEIGHT Put value of Kla A (m2) HTU=L/Kla*A (M) 0.0125 4.877186 0.227818

NTU HEIGT OF COLUMN (M)

#DIV/0! #DIV/0!

Henrys const (atm) Pressure (atm) Outlet Conc (ppm)

0.75 1 0

Na out (moles of A) Ce (molesof A/moles of water)

0 0

Densty of liq densty of gas viscosity to power 0.1 (0.001)

1000 1.204 0.5

Table 6.2 Constant for HETP Correlation

Ref.:: Random Packings and Packed Towers ---- Strigle