You are on page 1of 5

24 July 2012

Features:
No need of amplification device( booster, quick exaust ..) in most application Superior control capacity of amplification device when installed High flow with quick, precise complete control capability Powerful self calibration software Wide set of configurable embedded features Strong design with full metal housing

FastTrak key features


High capacity spool and housing design Patented control algorithms Unique environmental protection Extra strong feedback shaft, feedback sensor protected from load PC interface & diagnostic
3

2001. CCI Control Components Inc. All rights reserved.

24 July 2012

High capacity spool (CV = 2)


High capacity spool with short stroke -> better frequency response Fully pressure balanced spool design Low friction spool

Patented control algorithms


Patented control algorithms allow exceptional performances Special control loop design to remove sw delay The self calibration wizard allow an easy setup Adjustable control parameter independently to open and close

Unique environmental protection


FT meets IP66 protection class. Two flexible diaphragms on exhaust ports work as check valves preventing water and dust from entering the spool area

2001. CCI Control Components Inc. All rights reserved.

24 July 2012

Extra strong feedback shaft, feedback sensor protected from load

Feedback sensor is mounted elastically and independent from feedback shaft therefore gets no load Strong shaft with long bearing guide takes all the load

PC interface & diagnostic


Graph tool

Actual status

Tuning parameters

Diagnostic

Advanced options
8

Self Tune wizard

2001. CCI Control Components Inc. All rights reserved.

24 July 2012

Tuning parameters

Actual status

10

Advanced options :
-Transfer function curve -Digital Input config -Digital Output config -Analog Output config -4-20mA Input calib -Split range

11

Graph Tool :

12

2001. CCI Control Components Inc. All rights reserved.

24 July 2012

FT specifications:
Power Supply/Signal : Signals Connections: Pneumatic Connect. Outputs: Operating angle: Communication: Air supply: Flow capacity: Bleed at steady state: Certifications & Qual. Protection Class: Ambient Temperature: Housing material: Weight: 4 to 20 mA (min.3,5 mA, 12-30V dc);HART 2x NPT (M20x1,5 on request) 3x NPT (1 supply+2 outputs) 4 to 20 mA pos. feedback+2 configurable digital (optocoupler 24V dc) 30to 120( <30possible with lower resolution) via Hart and TTL RS232 2,5 to 10 barg instrument air acc. ISO 8573-1, cl.3 180 Nm3/h at 6 barg ( Cv=2,3) 1,2 Nm3/h at 6 barg CE, Atex EEx.ia.IIC.T6/T5/T4 (intrinsecally safe) IP 66 -30 to +80 C C Aluminium, copper free 3,25 kg
13

FT Positioner Hazardous area II 2GD Eex d IIC installation (future development)


FT can be opened for setup/diagnostic without removing power Handheld can be connected locally to test positioner performances