6th FLOOR PLAN
01
02
03
04
05
LADIES
LIFT
LIFT
WC WC
HOSE REELS TO DETAILS
sh. WC
CLEANER'S ROOM
GENTS
WC WC
SECRETARY
TERRACE
WALKWAY
DEPUTY SECRETARY.
KNCST
Administration
R
E
C
E
PT
IO
N
WAITING
AREA
BOARD
ROOM.
CHAIRMAN
BA
LC
O
N
Y
WAITING
SE
C
R
E
T
A
R
Y
OFFICE
CLEANERS
RM
WC
K
IT
C
H
E
N
E
T
T
E
SECRETARY.
KNCST
SECRETARY
WAITING
AREA
WALKWAY
STORE
WC
sh.
whb
CLEANERS
RM
BATH
BATH
A B C D E F G H J K L M N P Q
01
02
03
04
05
DEPUTY SECRETARY.
KNCST
Technical Services
RECEPTION & WAITING AREA
hd
ur ur
ur
ur
sd
hd
sd
hd
sd
hd
sd
200 x 200
a ir re gist e r
200 x 200
a ir re gist e r
200 x 150
200 x 200
Duct Rise
0.09mfs
0
.1
5
m
fs
0.20mfs
200 x 200
a ir re gist e r
200 x 200
a ir re gist e r
200 x 150
200 x 200
Duct Rise
0.09mfs
0
.1
5
m
fs
0.20mfs
200 x 150
0.09mfs
200 x 200
a ir re gist e r
20
To floor t ra p
25
From out door unit
T
o
flo
o
r trap
Indoor ce iling ca s s e t t e unit of
ca pa cit y 7. 1Kw ( 24, 000Bt u/ hr)
Indoor ce iling ca s s e t t e unit of
ca pa cit y 7. 1Kw ( 24, 000Bt u/ hr)
From out door unit
Re frige ra nt Pipe s in t he ce iling
To floor t ra p
Indoor ce iling ca s s e t t e unit of
ca pa cit y 3. 5Kw ( 12, 000Bt u/ hr)
Indoor ce iling ca s s e t t e unit of
ca pa cit y 3. 5Kw ( 12, 000Bt u/ hr)
Indoor ce iling ca s s e t t e unit of
ca pa cit y 3. 5Kw ( 12, 000Bt u/ hr)
Indoor ce iling ca s s e t t e unit of
ca pa cit y 7. 1Kw ( 24, 000Bt u/ hr)
Indoor ce iling ca s s e t t e unit of
ca pa cit y 3. 5Kw ( 12, 000Bt u/ hr)
Indoor ce iling ca s s e t t e unit of
ca pa cit y 5. 3Kw ( 18, 000Bt u/ hr)
Indoor ce iling ca s s e t t e unit of
ca pa cit y 5. 3Kw ( 18, 000Bt u/ hr)
Indoor ce iling ca s s e t t e unit of
ca pa cit y 5. 3Kw ( 18, 000Bt u/ hr)
Indoor ce iling ca s s e t t e unit of
ca pa cit y 7. 1Kw ( 24, 000Bt u/ hr)
Indoor ce iling ca s s e t t e unit of
ca pa cit y 7. 1Kw ( 24, 000Bt u/ hr)
Indoor ce iling ca s s e t t e unit of
ca pa cit y 7. 1Kw ( 24, 000Bt u/ hr)
32 drainage pipe 32 drainage pipe 32 drainage pipe
Re frige ra nt pipe s
Re frige ra nt pipe s
350mm Re fuse Chut e
Re fuse Chut e door
Kitchen
Store AMBULENT
TOILET
Name Signature
1:100
MI NI STRY OF PUBLI C WORKS
ELECT. & MECH DEPT. ( BS)
CHI EF ELECT. AND MECH. ENGI NEER( BS)
Eng . W. R. Okubo , OGW
Date
Date Approve d
Client
Date Scale Drawing No.
Project
Title
THE GOVERNMENT OF THE REPUBLIC OF KENYA
BY DATE DESCRIPTION
REVISIONS
NO SIGNATURE
9. All fans should be supported firmly and should
have anti-vibration supports.
NOTES
1. All dime nsions a re in millime t e rs unle ss
ot he rwise st a t e d.
2. All dra wing sha ll be re a d t oge t he r wit h
Archit e ct s a nd St ruct ura l Engine e rs dra wings
3. All re frige ra nt pipe s sha ll be coppe r pipe s.
Sa mple sha ll be a pprove d be fore inst a lla t ion
comme nce s.
5. All pipe work sha ll run in duct s. Expose d pipe work
sha ll not be a cce pt e d.
4. Do not sca le from t his dra wing. All dime nsions t o
be crossche cke d on sit e . Any discre pa ncie s t o be
re port e d t o t he de signe r prior t o const ruct ion.
8. All outdoor units should be supported firmly and
should have anti-vibration supports.
7. The air conditioning units to operate on R410A
refrigerant or any other non-ozone depleting
refrigerant.
6. Contractor to allow for sealing off or making
good of junctions between beams, floor slab, or
any other incidental openings as necessary.
Eng . L. M. GI THI ARI
H. M. MWANGI
Eng . N. N. ONI MBO
M. E. KI GEN
C. S. Eng
Dra wn
De signe d
P. S. Eng
OFFI CE SI XTH FLOOR PLAN -
MECHANI CAL VENTI LATI ON AND
AI R CONDI TI ONI NG LAYOUT
NATI ONAL COUNCI L FOR
SCI ENCE AND TECHNOLOGY
P. O. BOX 3 0 6 2 3 - 0 0 1 0 0 ,
NAI ROBI .
JANUARY 2012
PROPOSED CONSTRUCTI ON OF
NATI ONAL COUNCI L FOR SCI ENCE
AND TECHNOLOGY HEADQUARTERS
D43/ 9768A/ M35
LEGEND
fa - from above
tb - to below
ta - to above
- drainage pipe
- Delivery line
-U Trap
- Supply line
-Ce iling Ca sse t t e indoor unit

You might also like