Dec 2008
ITEM NO. 209.01000 212.02100 212.02200 301.01020 513.00015 514.00015 900.60000 WATER DRY EXCAVATION WET EXCAVATION CRUSHER RUN SUBBASE CLASS B CONCRETE REINFORCING STEEL CONTRACTOR QUALITY CONTROL (CONCRETE) Construction, 2003 Edition correction for grade.
Wyo.
Proj.
2202016
Sheet
B33
of
B128
Sheets
DESIGN DATA
SPECIFICATIONS: AASHTO LRFD Bridge Design Specifications, 4th Edition
ESTIMATED QUANTITIES
ITEM UNIT MG CY CY TON LS LS LS TOTAL QUANTITY 125 6550 490 8032 LUMP SUM LUMP SUM LUMP SUM 610.8 CY 65,230 LB ESTIMATE
REINFORCED CONCRETE: Load and Resistance Factor Design Class B Concrete f c =3250 psi Reinforcing Steel f y =60,000 psi (Grade 60) fy =40,000 psi (Grade 40)
4.0 tsf
1.66 tsf
GENERAL NOTES
SPECIFICATIONS: WYDOT Standard Specifications for Road and Bridge WATERSTOP: Work necessary for the waterstop is incidental to the contract pay item Class B Concrete. Supplementary Specifications: SS-500G
REFERENCES
Dated
Structural Concrete With Quality Control and Quality Acceptance Rev 5-2-07
REINFORCING STEEL: Concrete cover to face of reinforcing steel is 2" unless noted. Dimensions for bent bars are out to out. BAR MARKS Straight Bars Size
~
WATER: Water at 13.6 gallons per ton has been estimated for compaction of the crusher run subbase.
4.02 - Example
DRY EXCAVATION: The estimated quantity of dry excavation is calculated below the existing ground line to elevation 4072.0.
Length
~
Designation
~
508-3
4A2
WET EXCAVATION: The estimated quantity of wet excavation is calculated below elevation 4072.0.
PREFORMED EXPANSION JOINT FILLER: Use preformed expansion joint filler conforming to AASHTO M 153 Type ?. Work necessary for the joint filler is incidental to the contract pay item Class B Concrete. FOUNDATION: The retaining wall is on a footing founded on dense sand and gravel.
BRIDGE PROGRAM
REVISIONS
Design Section
Q R Stuv
Sheet
DATE
JJJ
PPP
Drwg. No.
0021
of
2202016_2ts.dgn
AS=25
Dec 2008
30-4" 27-4" 3-0" 13-0" 17-4"
Wyo.
Proj.
2202016
Sheet
B34
of
B128
Sheets
City of Worland Underground Water Line Wyoming Gas Underground Gas Line
41+00
42+00
43+00
N 0^1200.0" W
Telephone Pole | Const Jt RT Communications Overhead Telephone Line & Exp Jt | Const Jt & Exp Jt
FF Wall
Footing
| Exp Jt
| Survey
PLAN
Elev 4089.72
Contr Jt (Typ)
Top of Wall
Elev 4089.29
Elev 4088.84
Elev 4088.59
4080
4070 | Const Jt 4060 & Exp Jt Bott of Footing | Const Jt & Exp Jt Elev 4070.00 | Exp Jt
ELEVATION
WYOMING DEPARTMENT OF TRANSPORTATION
BRIDGE PROGRAM
REVISIONS
4.21 - Example
DATE
Q R Stuv
Sheet
0021
of
2202016_2gp.dgn
OPW
OTW
AS=12
Dec 2008
13-0"
Wyo. Proj.
2202016
Sheet
B35
of
B128
Sheets
6"
6"
Match Line
Match Line
FF Wall
FOOTING PLAN
(Longitudinal keyway not shown)
4.21 - Example
2202016
DESIGN DETAIL QS
Wa
DATE
Q R Stuv
Sheet
0021
of
2202016_2rw1.dgn
AS=8
Dec 2008
3-10" 17-7" 13-9"
Wyo. Proj.
2202016
80-0"
Sheet
B36
of
B128
Sheets
25-0"
460-0 & 421-7 @12"=2-0" (EF)
3" 3"
@12"=13-0" (EF)
6"
Wall Segment B
13-9"
660-0 or 622-7
(3-10" to 3-8 5/8 ")
Varies
7W2
417-3
13-9"
FF Wall
460-0 or 421-7
Note: 1) Place 7W2 bars with 7W1 bars. 2) Place 7W2 and 417-3 bars to maintain 2" clearance from top of wall. 3) Trim contraction joints with 1/2 " bevel strips.
4.21 - Example
712-8
WYOMING DEPARTMENT OF TRANSPORTATION
2-3"
BRIDGE PROGRAM
REVISIONS
7W1
3" Cl
Wa
SECTION A-A
DATE
DETAIL QS
Q R Stuv
Sheet
0021
of
2202016_2rw2.dgn
AS=8
Dec 2008
3-8 5/8 " 17-5 5/8 " 13-9" (3-8 5/8 " to 3-3 1/2 ") Varies 13-9"
Wyo.
Proj.
2202016
90-0"
Sheet
B37
of
B128
Sheets
30-0"
460-0 & 431-7 @12"=2-0" (EF)
3" 3"
| Exp Jt
| Exp Jt
3"
@12"=13-0" (EF)
6"
Wall Segment C
13-9"
660-0 or 632-7
7W3
416-10
FF Wall
460-0 or 431-7
Note: 1) Place 7W3 bars with 7W1 bars. 2) Place 7W3 and 416-10 bars to maintain 2" clearance from top of wall. 3) Trim contraction joints with 1/2 " bevel strips.
4.21 - Example
712-8
WYOMING DEPARTMENT OF TRANSPORTATION
2-3"
BRIDGE PROGRAM
REVISIONS
7W1
3" Cl
Wa
SECTION B-B
DATE
DETAIL QS
Q R Stuv
Sheet
0021
of
2202016_2rw3.dgn
AS=8
Dec 2008
3-3 1/2 " 17-0 1/2 " 13-9" (3-3 1/2 " to 2-10 1/8 ") Varies 13-9"
Wyo.
Proj.
2202016
90-0"
Sheet
B38
of
B128
Sheets
30-0"
460-0 & 431-7 @12"=2-0" (EF)
3" 3"
| Exp Jt
| Exp Jt
3"
@12"=13-0" (EF)
6"
Wall Segment D
13-9"
660-0 or 632-7
7W4
416-5
FF Wall
460-0 or 431-7
Note: 1) Place 7W4 bars with 7W1 bars. 2) Place 7W4 and 416-5 bars to maintain 2" clearance from top of wall. 3) Trim contraction joints with 1/2 " bevel strips.
4.21 - Example
712-8
WYOMING DEPARTMENT OF TRANSPORTATION
2-3"
BRIDGE PROGRAM
REVISIONS
7W1
3" Cl
Wa
SECTION C-C
DATE
DETAIL QS
Q R Stuv
Sheet
0021
of
2202016_2rw4.dgn
AS=8
Dec 2008
3" 3" | Exp Jt
2-10 1/8 " 449-7@12"=13-0" (EF) 3" 12" 16-7 1/8 " 13-9"
Wyo.
Proj.
2202016
Sheet
B39
of
B128
Sheets
| Contr Jt
649-7 (EF)
2-7 1/8 "
449-7 (EF)
16-4 1/8 "
8-0" 1-0"
2-0"
3-0" 1-0"
6"
13-9"
649-7
(2-10 1/8 " to 2-7 1/8 ") Varies
7W5
416-2
13-9"
FF Wall
449-7
712-8
Note: 1) Place 7W5 bars with 7W1 bars. 2) Place 7W5 and 416-2 bars to maintain 2" clearance from top of wall. 3) Trim contraction joints with 1/2 " bevel strips.
4.21 - Example
2-3"
460-0 or 419-3
7W1
3" Cl
SECTION D-D
APPROVED DATE
2202016
DESIGN DETAIL QS
Wa
Q R Stuv
Sheet
0021
of
2202016_2rw5.dgn
AS=8
X 2008 Dec 2008
27-4" Location Mark 419-3 | Survey Footing Roadway FF Wall 460-0 7W1 712-8 Weight 416-2 416-5 Backfill to match existing ground line 416-10 Approximate Existing Ground Line 417-3 421-7 431-7 449-7 1 1 3/4 Wall 460-0 622-7 632-7 Back Limits of Excavation 649-7 660-0 7W2 2-6" 7W3 7W4 18
3-6 1/2 " 3-1 1/2 "
Wyo.
Proj.
2202016
Sheet
B40
of
B128
Sheets
BILL OF REINFORCEMENT
Number Required
4 1/2 "
Bending Diagrams
3"
2 3/4 "
90
5-1"
620 32,458 LB
90 90 80 34 68
7W1 (9-11")
2 1/4 "
2-8"
102 2 4
2-5"
2"
7W2 (17-4")
2-8" 2-5"
7W3 (16-11")
32
50
5-1"
620
TYPICAL SECTION
7W5 Weight
7W4 (16-6")
7W5 (16-3")
| Exp Jt
Note: The estimated quantity of class B concrete for footing is 335.8 CY. The estimated quantity of class B concrete for wall is 275.0 CY.
6"
4.21 - Example
FF Wall
REVISIONS
BRIDGE PROGRAM
DATE
Q R Stuv
Sheet
0021
of
2202016_2rw6.dgn