E.M.F. Equation & Armature Resistance of a D.C. Generator Losses in a D.C. Machine


Get posts electricalandelect en_US

Advanced Battery Storage System (11) Types of D.C. Generators Air Blast Circuit Breaker (2) arc interruption Author: arjun method (1) Category: Direct Current Armature Reaction Machines, Electrical Machines and Commutation (7) Brushless Motors (2) The magnetic field in a d.c. generator is Cables (1) normally produced by electromagnets causes of over rather than permanent magnets. voltage (1) Generators are generally classified circuit breaker rating according to their methods of field (1) excitation. On this basis, d.c. generators circuit breakers (13) are divided into the following two classification of classes: relays (20) (i) Separately excited d.c. generators Construction of D.C. (ii) Self-excited d.c. generators Machines (11) The behaviour of a d.c. generator on load D.C. Generator depends upon the method of field Characteristics (9) excitation adopted. DC Motor (11) Depletion type Separately Excited D.C. Generators MOSFET (3) DIAC (1) A d.c. generator whose field magnet Diesel Power Plant winding is supplied from an independent (2) external d.c. source (e.g., a battery etc.) is Direct Current called a separately excited generator. Fig. Machines (47) (1.32) shows the connections of a Electrical Energy (4) separately excited generator. The voltage Electrical output depends upon the speed of rotation Installations (9) of armature and the field current (Eg Electrical Machines =P ZN/60 A). The greater the speed (52) and field current, greater is the generated Electromechanical e.m.f. It may be noted that separately energy conversion excited d.c. generators are rarely used in

Subscribe

Looki ng Back
o

Jan uar y 20 10 De ce mb er 20 09 Se pte mb er 20 09 Au gus t 20

o o o o o o o o o o o o o o o

o o o o o o o o o o o o o o

(3) practice. The d.c. generators are normally Enhancement type of self-excited type. MOSFET (2) Equipments of steam power plant (5) Feeder protection (12) fuzzy logic control (4) Gas turbine power plant (2) Gate Turn Off Thyristor (4) generator (1) Generator protection (6) HVAC system (1) Hybrid Vehicle (3) Hydro-electric Power Plant (4) Hydrophone (3) IGBT (1) important terms regarding relays (1) Important terms Self-Excited D.C. Generators regarding switch A d.c. generator whose field magnet gears (1) winding is supplied current from the introduction (1) output of the generator itself is called a LED (4) self-excited generator. There are three LED wireless (2) types of self-excited generators Lightning (11) depending upon the manner in which the Linear Integrated field winding is connected to the Circuits (13) armature, namely; Maglev (3) (i) Series generator; Miscellaneous (1) (ii) Shunt generator; MOSFET (4) (iii) Compound generator motors (1) (i) Series generator Nuclear power plant In a series wound generator, the field (3) oil circuit breaker (5) winding is connected in series with armature winding so that whole armature op-amp (12) op-amp applications current flows through the field winding as well as the load. Fig. (1.33) shows the (2) connections of a series wound generator. Open and closed loop configurations Since the field winding carries the whole of load current, it has a few turns of thick (2) wire having low resistance. Series

09 Jul y 20 09 Ma y 20 09 Ap ril 20 09 Ma rch 20 09 Fe bru ary 20 09 Jan uar y 20 09 No ve mb er 20 08 Oct obe r 20 08 Se pte mb er 20 08

o o o o o o o o o o o o

o o o o o o o o o

o o o o o o o

organic LEDs (2) generators are rarely used except for Parallel Operation of special purposes e.g., as boosters. D.C. Generators (3) Photo Voltaics (11) piezoelectric motor (1) Power diode (1) Power Electronics (26) power line communication (2) Power Plant (21) Power System (100) Power Transformers (1) Power transistor (1) Preparation of completion Reports (1) Project Based Papers (2) Projects (22) Protection against lightning (9) generator Protective earthing Shunt In a shunt generator, the field winding is (1) Protective Relays (1) connected in parallel with the armature winding so that terminal voltage of the Radio Frequency generator is applied across it. The shunt Identification (6) field winding has many turns of fine wire Reference Papers having high resistance. Therefore, only a (73) part of armature current flows through Relays (25) shunt field winding and the rest flows requirement of protective relaying through the load. Fig. (1.34) shows the connections of a shunt-wound generator. (1) SCADA (2) SF6 Circuit Breaker (1) smart dust (8) Solar Power Satellite (7) Stages of op-amp (3) Steam Power Plant (9) super conducting Compound generator motor (5) In a compound-wound generator, there

o o o o o o o o o

Surge Over Voltages (17) Switch Board Assemblies (1) Switchgear&Protecti on (77) Technology & Innovation (13) Thyristor (15) Transformer Protection (3) Types of relay protection (1) Uncategorized (1) vacuum circuit breaker (1)

are two sets of field windings on each poleone is in series and the other in parallel with the armature. A compound wound generator may be: (a) Short Shunt in which only shunt field winding is in parallel with the armature winding [See Fig. 1.35 (i)]. (b) Long Shunt in which shunt field winding is in parallel with both series field and armature winding [See Fig. 1.35 (ii)].

Brush Contact Drop It is the voltage drop over the brush contact resistance when current flows. Obviously, its value will depend upon the amount of current flowing and the value of contact resistance. This drop is generally small. Share and Enjoy:

If you enjoyed this post, make sure you

subscribe to my RSS feed!

12 Responses to Types of D.C. Generators


1. rashad Says:
July 20th, 2009 at 7:09 pm

its good 2. VIMALRAJ Says:


July 23rd, 2009 at 4:05 am

satisfaction 3. mohan Says:


August 17th, 2009 at 11:15 pm

MITE BE GOOD 4. srikanth Says:


November 9th, 2009 at 8:37 am

average performence 5. happy Says:


January 21st, 2010 at 6:44 am

thanks 6. pramod kumar Says:


February 17th, 2010 at 11:44 am

nice arr!! 7. JAYDEV Says:


February 19th, 2010 at 2:35 pm

GOOD PERFORMENCE 8. Rukmini Says:


February 26th, 2010 at 5:13 pm

very very nice and good 9. Rukmini Says:

February 27th, 2010 at 8:51 am

please post design of dc machines 10. tibebu tirunh Says:


March 15th, 2010 at 1:33 am

solve my problem 11. Salman Khalidi Says:


May 2nd, 2010 at 12:28 am

please also post the speed control method of all these cases.. 12. Akhil Says:
May 23rd, 2010 at 6:42 am

its nice.please post with animations.itll be interesting.