The gas feed systems V10k automatic and manual control is the proven gas feed technology from Wallace & Tiernan for capacities up to 15 kg/h combining a standardised flexible design with user-selectable configurations. The V10k gas feeders operate according the indirect procedure i.e. operating under a vacuum that is produced at the injector where the metered gas (e.g. chlorine gas) is dissolved in the operating water and the resultant solution is discharged to the point of application. Gas flow control is achieved by the proven Wallace & Tiernan V-notch ensuring the well-known accuracy and repeatability.

V10k automatic

METHOD OF OPERATION ADVANTAGES


Versatile gas feeder for wall-mounting Proven technology, excellent reliability and long service life Proven V-notch flow control technology providing accuracy and repeatability Rotameters with high resolution and easy readability in 15 capacities up to 15 kg/h Differential regulating valve for precise feed rate control at low vacuum levels and economical injector operation Operating range for automatic control mode 1: 20 Vacuum gauge for visual operation monitoring Serviceability - components easily accessible V10k automatic control: optional fully automatic control by process controller (e.g. PCU-fuzzy or with actuator control 4 20 mA) V10k manual control: retrofit for automatic control (electric positioner) possible Available for all water treatment gases: Chlorine Carbon dioxide Ammonia Sulphur dioxide (for other gases consult) The V10k gas feed systems operate under a vacuum that is produced at the injector and transmitted through the control unit to the pressure / vacuum regulating valve on the gas supply source. This diaphragm-operated valve is opened by the vacuum and allows the gas to flow to the control unit where it passes through the rotameter and the V-notch orifice. On the rotameter the gas flow rate is measured and indicated. Downstream of the V-notch orifice the gas passes the differential regulating valve which maintains a consistent feed rate regardless of changes in the operating vacuum. At the injector, the metered gas is dissolved in the operating water stream and discharged as solution to the point of application. Highest Safety by Remote Vacuum The remote vacuum principle (vacuum from the gas supply containers up to the injector) is the basic technology of this design. There are no gas lines under pressure. If any part after the supply container gets broken, no gas can leak out, but air will leak in. Therefore the remote vacuum technology stands for the highest safety level in gas feed systems. V-notch for Precise Gas Flow Control The V-notch control orifice, field proven in hundreds of thousands of installations around the world, provides reliable, consistent gas feed at any capacity. It consists of a precision-grooved plug that slides through an annular seat. Any position of the plug in the seat results in a specific orifice size and a corresponding feed rate. This results in accurate gas flow control and excellent repeatability. Due to their size and the configuration of the orifice, the V10k systems are resistant against fouling from contaminants in the gas supply. Control of the gas feed rate for the V10k manual control gas feed system is achieved manually by turning the adjustment knob, for the V10k automatic control gas feed system either manually or automatically via an electric positioner. Electric Positioner for Automatic control For automatic control, the V-notch plug is moved depending on the application requirements: Manual override is achieved by simply pulling the knob to disengage the drive motor 3 sets of volt-free contacts for system control: manual override MAX position MIN position Feedback potentiometer for precise operation with the SCU or PCU-fuzzy controllers 4 20 mA actuator control (optional) Simple ratio control Feed rate adjustment by means of a dosing factor Connection to SPS control systems

WALLACE & TIERNAN


www.wallace-tiernan.com

TI 25.100DE

TI 050.400-10DD

TECHNICAL DATA

Gases and Scale Capacities: Chlorine: up to 15.0 kg/h Carbon dioxide: up to 8.0 kg/h Sulphur dioxide: up to 10.0 kg/h Ammonia: up to 5.0 kg/h Feed Ranges: e.g. chlorine gas 1 22.5 g/h 3 60.5 g/h 10 200.5 g/h 20 400.5 g/h 30 600.5 g/h 50 1000.5 g/h 75 1500.5 g/h 100 2000.5 g/h

Power Supply (V10k automatic control): 0.25 A at 230 V AC 0.50 A at 115 V AC Electric Positioner (V10k automatic control): Operating voltages: 230 V 115 V 50/60 HZ 50/60 Hz Rating: 19 mA 46 mA Time for 0100% move: 80 sec. 66 sec. Potentiometer: 1 kOhm 10 % Max. switching capacity: 1250 VA 150 W Enclosure: IP 67 Available Configurations: with 5 rotameter (standard) or 10 rotameter 4 kg/h, 10 kg/h vacuum regulator or higher capacities standard or with switch-over option injector size 1/3, 1 or 2 standard or anti-siphon type Option: Vacuum contact pressure gauge for installation into the gas supply line for monitoring operating vacuum Dimensions: V10k automatic control incl. panel (W x H x D): with electric positioner: 369 x 880 x 185 mm with electric positioner and controller 580 x 880 x 185 mm V10k manual control: 350 x 380 x 150 mm Weight: V10k automatic control with electric positioner V10k automatic control with electric positioner and controller V10k manual control 15 kg 20 kg 5 kg

0.15 3.0 kg/h 0.20 4.0 kg/h 0.25 5.0 kg/h 0.30 6.0 kg/h 0.40 8.0 kg/h 0.50 10.0 kg/h 10.00 15.0 kg/h

Operating Range (V10k automatic control): 1: 20 for any rotameter V10k manual Accuracy: 4 % of F. S. Operating Temperature: +10 C to + 50 C Operating Vacuum: 40 200 mbar Operating Water Pressure at Injector: max. 21 bar at 20 C max. 13 bar at 30 C max. 10 bar at 40 C max. 5.9 bar at 50 C 4 20 mA actuator control (optional) Measurement Inputs: 1 x 4 20 mA 1 x servo motor position feedback 1 x external dosing factor Relay Outputs: 2 x non-isolated Power Supply: 115/230 V AC, 50 60 Hz

WALLACE & TIERNAN


Australia WALLACE & TIERNAN Pty Limited Level 1, 6 10 Talavera Road North Ryde, NSW 2113, AUSTRALIA Tel.: +61 2 9850 2800, Fax: +61 2 9850 2801 Email: wt.sales@wandt.com.au Canada U.S. FILTER / WALLACE & TIERNAN 250 Royal Crest Court Markham, Ontario L3R 3S1, CANADA Tel.: +1 905 944-2800, Fax: +1 905 474-1660 France WALLACE & TIERNAN S.A.R.L. BP 150, 1/3 rue Pavlov F-78196 Trappes Cedex, FRANCE Tel.: +33 1-34 82 18 50, Fax: +33 1-30 50 98 08 Email: wtfr@chemfeed.org Germany WALLACE & TIERNAN GmbH Auf der Weide 10 D-89312 Gnzburg, GERMANY Tel.: +49 8221-9040, Fax: +49 8221-904203 Email: wtger@chemfeed.org Mexico U.S. FILTER Chem Feed Mexico SA De CV Via Jose Lopez Portillo 321 Tultitlan, Edo. Mex., 54900 MEXICO Tel.: +52 55 2159-2959, Fax: +52 55 2159-2985 Email: ventasmx@usfilter.com Romania WALLACE & TIERNAN Romania srl. Str. Liviu Rebreanu nr. 6 Bl B1 Sc. A, ap. 39, Sector 3, Bucuresti, ROMANIA Tel.: +40 21-3046011, Fax: +40 21-3046012 Email: wtro@chemfeed.org United Kingdom WALLACE & TIERNAN Priory Works, Tonbridge Kent TN11 0QL, ENGLAND Tel.: +44 1732-771777, Fax: +44 1732-771800 Email: inform@wallace-tiernan.com USA U.S. FILTER / WALLACE & TIERNAN Products 1901 West Garden Road Vineland, NJ 08360, USA Tel.: +1 856-507-9000, Fax: +1 856-507-4125