Professional Documents
Culture Documents
The module of HSM-20G is essential for those applications where the relative humidity can be converted to standard voltage output.
1. Applications
Humidifiers & dehumidifiers Air-conditioner Humidity data loggers Automotive climate control Other applications
2.Specifications
Characteristics Input voltage range Output voltage range Measurement Accuracy Operating Current (Maximum) Storage RH Range Operating RH Range Transient Condensation Temperature Range Storage Operating Hysteresis (RH @ 25) Long Term Stability(typical drift per year) Linearity Time Response(63% step change) Dimensions(L*W) HSM-20G DC 5.00.2V DC 1.03.0 V 5% RH 2mA 0 to 99% RH 20 to 95% (100% RH intermittent) < 3%RH -20 to 70 0 to 50 MAX 2%RH 1.5% Linearity 1 min 34mm*22mm
3.Reliability Test
No Item Method Requirment No breakge, nor racks Should be electrically normal Within 5%RH Within 5%RH Within 5%RH Within 5%RH Within 5%RH
Impact test
To drop module 3times at random on to a hard wooden plate from 1meter above high
Vibration test Heat Resistance Cool Resistance Humidity Resistance Temperature cycle test
3 4 5
Vibration test in X-Y-Z axis for 30min .under 10 55Hz frequency,1.5mm (10-55-10Hz) To leave module in an ambient of 55 and 30%RH max. for 48hours. To leave module in an ambient of-10 and 30%RH max. for 48hours. To leave in an ambient of 40 and 95%RH for 48hours. 5cycles.1cycle stands for leaving module under -10 for next 1hour. Then ,leave it another 1hours ,and lower temp. to-10 for next 1hour.
Remark : - All standard figures are based on humidity variation under 60%RH (at 25 ) - Upon completion of all test, module will be left over under nominal environment - And humidity for 24hours.
STANDARD CHARACTERISTICS %RH 10 20 0.95 30 1.31 40 1.68 50 2.02 60 2.37 70 2.69 80 2.99 90 3.19
OutpotV 0.74
R-T 10000
1000
Rk
100
Center (k)
10
1
11 0 12 5 -4 0 -5 5 -2 5 -1 0 20 50 65 80 95 35 5
R-T
180 160 140 120 RK 100 80 60 40 20 0 0 10 20
HSM-20G47K HSM-20S(50K)
30 T
40
50
60