You are on page 1of 2

INTRINSICALLY SAFE OIL SMART PUMP SYSTEM

Overview:
See Water offers a complete line of Intrinsically Safe Oil Smart pump control systems. The systems are designed to pump water without the risk of pumping oil, and provide constant monitoring of oil and water in hazardous locations. The components are UL listed as Intrinsically Safe approved for Class 1, Div 1, and Group D Applications. See Water offers a complete line of Intrinsically Safe Oil Smart pump control systems. These Intrinsically Safe Control Panels are used on pump applications. The Panels provide intrinsically safe circuit extensions and control one (simplex) or two (duplex) pumps for use in hazardous locations. Features: Industrial alarm system that is UL listed relating to hazardous locations with intrinsically safe circuit extensions approved for Class 1, Div 1, Group D applications Intrinsically safe Liquid Smart Sensor, Oil Smart Sensor, and High Water Sensor (included only with Duplex systems) with 20 cords Indoor/outdoor NEMA 4X heavy duty polycarbonate enclosure with clear front and lockable latches Intrinsically safe relay box to provide maximum safe circuit protection High liquid alarm with test and silence buttons, red beacon alarm light. Alarm sounds at 85 decibels at 10 feet Dry contacts for oil, water and high liquid condition High demand two pump operation and pump alternation (Duplex only) IEC motor contactor, pump circuit breaker, adjustable overload protection is provided in three phase panels. HOA switch for auto or manual pump control, pump run indicator

121 N. Dillon Street |San Jacinto, CA 92583 Voice: (951) 487-8073 | FAX: (951) 487-0557 http://www.seewaterinc.com

Applications Hazardous locations classified as Class 1, Div 1, Group D Elevator sumps, underground vaults, petroleum Any application where there is a need to remove water while containing oil

Specifications:

Duplex Single Phase IS-WD1P-4-1021 IS-WD1P-4-1022 IS-WD1P-4-1023 IS-WD1P-4-1024

120/208/240VAC 0-7 FLA 7-15 FLA 15-22 FLA 22-32 FLA

Technical Specifications:

Oil Smart Entity Parameters: Vmax=15.5VDC, Imax=300mA, Li=OuH, Ci=3.05uF Oil Smart enclosure: Type 3R high impact Injected plastic: 11.3H x 2.5W x 1.9D High Water Entity Parameters: Vmax=15.5VDC, Imax=300mA, Li=1.13mH, Ci=.26uF max High Water enclosure: Type 3R high impact Injected plastic: 3.6H x 1.5W x 1.5D Liquid Smart Entity Parameters: Vmax=15.5VDC, Imax=450mA, Li=1.13mH, Ci=.26uF Liquid Smart enclosure: Type 3R high impact Injected plastic: 4.7H x 1.5W x 1.5D Intrinsically Safe components for use in Class 1, Div 1, Group D Hazardous Locations

121 N. Dillon Street |San Jacinto, CA 92583 Voice: (951) 487-8073 | FAX: (951) 487-0557 http://www.seewaterinc.com