You are on page 1of 1

ASME B31.3, 2008 Edition, para. 304.

1
P (Internal Pressure)
D (Outside Diameter)
S (Allowable Stress at Temperature)
E (Weld Joint Efficiency)
W (Weld Joint Reduction Factor)
Y (Coefficient, Table 304.1.1)
CA (Corrosion Allowance)
UTP (Undertolerance Allowance)
t (Given Wall Thickness)

660
12.75
13000
0.8
1
0.4
0
0.125
0.468898

(PSIG)
(INCH)
(PSI)

(INCH)
(INCH)

11.91 (MM)

Calculation Variables
UT = t*UTP
nt = (t-CA-UT)
Ri = Do/2-nt
d=Ri*2

0.058612
0.410285
5.964715
11.92943

t1 = P*D/(2*(S*E*W+P*Y)) , Minimum Required Wall Thickness


t2 = P*(d +2c)/(2*(S*E8W - P*(1-Y)))

0.394552 (INCH)
0.393514 (INCH)

10.02161 (MM)
9.995249 (MM)

Check MAX(t1,t2)<=nt?

OK

Geometry and Pressure Check


t<(Do/6), Diameter
P/(S*E)<0.385, Pressure

OK
OK