Strip back approximately

50mm (2 in.) of cable jacket


using Siemon AllPrep

tool
(P/N: CPT-RGTP) or equivalent.
Note: Although round cable is shown, flat
cables may also be used
2
Angled MAX

3, MAX 5e, MAX6 & 10G

6 MAX Module Instructions


Pull cables through the
appropriate openings in the
faceplate and mount the faceplate
to the electrical box with the screws
provided.
Note: Faceplate may be mounted before or
after cable termination.
1
View the color code label on
the module to determine
proper location of conductors based
upon preferred wiring scheme.
Note: MAX 6 shown
3a
Fan out cables based on
desired wiring scheme. Cut
the rip cord or separator (if present)
as close as possible to the jacket.
Note: Be careful not to nick conductors.
There is no need to untwist pairs,
(except for bonded pairs) since the
310

block includes features to facil-


itate wire lacing.
4
Insert the MAX module into
the PG-MX guard. Center
cable jacket down into 310block
(as shown above). Lace all pairs by
pressing firmly into position as
shown. Optionally 2-pairs can be
terminated first to help secure cable
before lacing final 2-pairs.
5a
Correct termination:
Terminate using Siemon S814
termination tool or equivalent. Tool
is in-line with 310 block. MAX
module is contained within the PG-
MX guard. PG-MX guard can be
placed on a flat surface or in a
Siemon Palm Guard as shown.
Note: It is recommended to use the low
impact setting to maximize module stability
during termination.
6a
Incorrect termination:
Termination tool is not
perpendicular to the 310 block. MAX
module is not on a stable surface or
in the PG-MX guard. Cable jacket is
not within 310termination posts.
6b
For mounting locations with
limited rear clearance, tilt
cable 90 degrees to the side as
shown and lace as described in
step 5a.
Note: Modules cannot be side-stacked
if side entry is used.
5b
Slide termination cap onto
cable and snap into place prior to
testing.
7
Straight
Entry
Side
Entry
Required Step
FOR 10G 6 MAX MODULES
ONLY:
Follow the color-coded label for
T568A/B wiring schemes, starting
with the brown pair on the top left
IDC positions and ending with the
blue pair on the bottom right
positions.
3b
BROWN
BROWN
BLUE
BLUE
Rotate forward (45) and pull
straight out.
First remove the protective
door before inserting into
faceplate. Align the top of the MAX
module into the faceplate and angle
the module down until it snaps into
place.
9
Insert the color icons by
sliding them into place from
the side.To install protective rubber
doors, slide the bottom of the door
into slot below outlet opening until
it bottoms out.
10
Insert a patch cord to prevent
loss of module & push down
on the icon area to defeat the top
latch.
14
Press the door into the jack
opening. The door will close
easily when pressed. If the door is
not aligned correctly, verify steps 12
& 13 were performed correctly.
12
R
e
v
.

B



0
8
/
0
3


1
0
0
.
1
2
4
4
9


2
0
0
3

T
h
e

S
i
e
m
o
n

C
o
m
p
a
n
y
To assist safe installations, comply with the following:
A. Use caution when installing or modifying telecommunications circuits.
B. Never touch uninsulated wire terminals unless the circuit has been disconnected.
C. Never install this device in a wet location.
D. Never install wiring during a lightning storm.
Remove the rubber door
(if present).
13
Bend door and press firmly
into slot.
Note: Once inserted, the door hinges
downward for insertion of a modular plug.
Removal of the door is not required.
11
Cap removal can be
accomplished by prying with
a small screwdriver placed in slot as
shown.
8
Angled MAX 3, MAX 5e, MAX6 & 10G 6 MAXModule Instructions
Rotate the module (90)
backward to get the bottom
latch entirely out first.
15
Outlet Removal
16
Outlet Removal
45
Outlet Removal Outlet Removal
90
www.siemon.com
Siemon UK
Woking, England
Tel: (44) (0) 1483 480040
Siemon USA
Watertown, Connecticut
Tel: (1) 866-548-5814
Siemon Australia
Sydney, Australia
Tel: (61) 2 9452 2666
Siemon Canada
Markham, Ontario
Tel: (1) 905 940 9223
Siemon China
Beijing, P.R. China
Tel: (86) 10 6559 8860
Siemon France
Paris, France
Tel: (33) 1 46 46 11 85
Siemon Germany
Frankfurt, Germany
Tel: (49) (0) 69 97168 184
Siemon Italy
Milano, Italy
Tel: (39) 02 64 672 209
Siemon Latin America
Coral Gables, Florida USA
Tel: (1) 305 446 9150
Siemon Southeast Asia
Singapore
Tel: (65) 345 9119

You might also like