RANCANG BANGUN ALAT PENDETEKSI KADAR HEMOGLOBIN (PULSE
OXIMETRY) DALAM DARAH SECARA NON INVASIVE BERBASIS
MIKROKONTROLER ATMEGA 8535
DESIGN OF HEMOGLOBIN LEVEL DETECTOR (PULSE OXIMETRY) IN THE BLOOD
IN NON - INVASIVE MICROCONTROLLER
BASED ATMEGA 8535
Created by RAHMAD
Subject

: Detektor, Mikrokontroller

Subject Alt

: Detectors, Microcontrollers

Keyword :

: Pulse Oximetry; Noninvasive; Hemoglobin; and Microcontroller

Description :
Telah dibuat rancang bangun alat pendeteksi kadar Hb dalam darah secara Non-Invasive berbasis mikro dengan lancar.
Pulse oximetry adalah suatu metode non-invasive untuk mengukur persentase hemoglobin (Hb) yang saturasi dengan
oksigen di dalam darah. Metode ini menggunakan perbedaan panjang gelombang dari cahaya merah (660 nm) dan
cahaya inframerah (940 nm) yang ditangkap oleh sensor deteksi setelah melewati pembuluh balik dan pembuluh
kapiler pada ujung jari telunjuk. Data dari sensor deteksi tersebut dikirim ke mikrokontroller kemudian ditampilkan
ke LCD. Di mikrokontroller, data tersebut diolah kemudian diproses untuk mendapatkan data hemoglobin (Hb). Batas
normal hemoglobin dalam darah adalah diatas 12g/ml sampai 15g/ml. Akurasi dari proyek akhir ini mempunyai
persentase error 4 % sampai 4,8 % bila dibandingkan dengan alat ukur standart.

Description Alt:
Has made design of hemoglobin level detector (pulse oximetry) in the blood in non - invasive microcontroller based
smoothly Pulse oximetry is a non-invasive method to measure the percentage of hemoglobin (Hb) of saturation with
oxygen in the blood. This method uses different wavelengths of redlight (660 nm) and infrared light (940 nm) is
captured by the detection sensor after passing through the veins and capillaries at the tip of the index finger. Data from
the detection sensor is sent to the microcontroller is then displayed to the LCD. In themicrocontroller, the data is
processed and then processed to obtain the data of hemoglobin (Hb). Normal limits in hemoglobin is above 12 g/ml
until 15g/ml. The accuration of my final project have 4% until 4,8% if compared with standart oximetry.

Contributor

: Suyanto, ST, MT.

Date Create

: 23/07/2012

Type

: Text

Format

: pdf

Language

: Indonesian

Identifier

: ITS-NonDegree-24002130000362

Collection

: 24002130000362

Call Number

: RSF 621.381 536 Rah r

Page 1

Source

: Non Degree of Physics Engineering, RSF 621.381 536 Rah r, 2013

COverage

: ITS Community

Right

: Copyright @2012 by ITS Library. This publication is protected by copyright and per obtained
from the ITS Library prior to any prohibited reproduction, storage in a re transmission in any form
or by any means, electronic, mechanical, photocopying, reco For information regarding
permission(s), write to ITS Library

Full file - Member Only


If You want to view FullText...Please Register as MEMBER

Contact Person :
Administrator (timit_perpus@its.ac.id)
Taufik Rachmanu (taujack@its.ac.id)
Dewi Eka Agustina (dee@its.ac.id)
Ansi Aflacha Putri (ansi@its.ac.id)
Tondo Indra Nyata (tondoindra@gmail.com)
Aprillia Tri Wulansari (rezha_la2@ymail.com)

Thank You,

Nur Hasan ( hassane@its.ac.id )


Supervisor

Page 2

You might also like