256MB
512MB
1GB
SanDisk Corp.
SDCFB-256
SDCFB-512
SDCFG-1
AD-CFG256
-----
AD-CFX40T1G
BUFFALO INC.
RCF-X256MY
-----
RCF-X1GY
Capacity
2GB
4GB
8GB
SanDisk Corp.
* This instrument supports FAT16 and cannot save data of 2GB or more if a card of 4GB
or more is used.
(Identified as over capacity when the area of usage exceeds 2GB.)
* When a mark of
displayed for several tens of seconds at powering on the
instrument, the CF card inserted may not be appropriate to be used with this instrument.
In this case, try to format the card on this instrument. If it is failed, the card cannot be
used with this instrument.
Max possible recoding time
256MB
512MB
400,000
800,000
1sec
2 days
4 days
1min
144 days
288 days
Capacity
Instantaneous
measurement
Interval at
Integration/
Demand
measurement
30min
1GB
2GB
4GB
1,000,000 or more
9 days
18 days
over 1 year
over 1 year
20
8GB
Quick manual
MODEL 6300
KYORITSU ELECTRICAL INSTRUMENTS
WORKS, LTD.
.......................................................... 2
.............................................................. 3
................................................. 5
............................................................................ 8
.................... 9
..................... 13
............... 16
........................................................ 19
1. Functional overview
(Section 1)
ON: (Section 3)
* AC power supply
* Battery
OFF
W range
Wh range
DEMAND range
SET UP range
(Section 6)
Instantaneous value
measurement
(Section 7)
Integration value
measurement
(Section 8)
Demand value
measurement
(Section 4)
Setting
Measurement screen
Indication
W range
Instantaneous value
(Custom display)
Saving data
Saving method
Manual saving
Saving point
key
Saving item
Instantaneous
value
File name
*CF card
1F I LE000.CSV
*Internal memory
1DATA000.CSV
Measurement start/stop
* manual operation
* specifying date & time
Wh range
Integration value
key
Saving item
*Instantaneous value (*)
*Integration value
File name
*CF card
2F I LE000.CSV
*Internal memory
2DATA000.CSV
(USB communication)
(Section 10) Communication
function
* Basic setting
* Setting for integration
measurement
* Setting for demand
measurement
* Other settings
DEMAND range
Demand value
Saving data
Saving method
Automatic saving
Saving point
Integration interval
Data download
Saved file
Setting screen
Additional functions
(Section 11)
Other functions
Saving data
Saving method
Automatic saving
Saving point
Demand interval
Saving item
*Instantaneous value (*)
*Integration value
*Demand value
File name
*CF card
3F I LE000.CSV
*Internal memory
3DATA000.CSV
PC
2
External settings
(USB communication)
(Section 10) Communication
function
2. Instrument layout
Display & keys (2-1)
(Section 2)
LCD
Function switch
* Turns the instrument on when it is in
any position other than OFF.
(Section 3)
1. AC power supply, or
2. Battery
Keys
Details
Keys
Details
* Cancels a setting
* Clears integration/ demand value
* Data hold
* Key lock
Pressing this key for at least 2 sec
locks keys.
Pressing again this key for at least
2 sec releases key lock.
Saves the instantaneous
measurement data.
Measurement screen:
Switches the display contents.
Setting screen:
Changes selection, number, or
moves digits.
Connector (2-2)
USB connector
CF card
Connector
Power supply connector
Current input terminal
(A1, A2, A3
Eject button
Wiring
Phase
number
Unit
Current range
< Marks indicate the measurement status or functions >
Mark
3. Setting:
SET UP
range (Section 4)
Basic
setting
Mark
01
Wiring
02
Voltage range
03
Current range
Clamp sensor
VT ratio
06 CT ratio
04
05
Other
settings
Settings
only for
integration
measurement
07
Time (*1)
08
Buzzer
09
Integration interval
Integration start
time & date
11 Integration stop
time & date
12 Reset of
integration value
10
13
Demand Interval
Demand start
time & date
15 Demand stop
time & date
Settings
only for
16 Demand target
demand
value
measurement 17 Demand inspection
cycle
14
18
Setting
1P2W(1ch)/ 1P2W(2ch)/
1P2W(3ch)/ 1P3W/ 3P3W /3P4W
150/ 300/ 600V
Range
(04 Clamp sensor)
5/ 10/ 20/ 50A
: (50A)
10/ 20/ 50/ 100A
: (100A)
20/ 50/ 100/ 200A
: (200A)
50/ 100/ 200/ 500A : (500A)
100/ 200/ 500/ 1000A : (1000A)
1000/ 3000A
: (3000A)
50/ 100/ 200/ 500/ 1000/ 3000A
1 ~ 10000
1.00 ~ 10000.0
Year : Month : Day,
Hour : Minute : Second
on (sound)
oFF (not sound)
1/ 2/ 5/ 10/ 15/ 20/ 30 sec.
1/ 2/ 5/ 10/ 15/ 20/ 30 min., 1 hour
Year : Month : Day,
Hour : Minute : Second
Year : Month : Day,
Hour : Minute : Second
on (reset)
oFF (not reset)
1/ 2/ 5/ 10/ 15/ 20/ 30 sec.
1/ 2/ 5/ 10/ 15/ 20/ 30 min., 1 hour
Year : Month : Day,
Hour : Minute : Second
Year : Month : Day,
Hour : Minute : Second
0.1W ~ 999.9GW
Can select a time from any three
of preceding time as demand
interval.
<e.g.>
Interval =30min. 10/ 15/ 20 min.
on (reset)
oFF (not reset)
Reset of
demand value
5
Each Setting
Mark
20 Formatting of
on
oFF
CF card (*3)
Other
settings
Setting
on
oFF
23 System reset
24 Loading settings
25 Saving settings
(use)
(not use,
use internal memory)
(formatting)
(not formatting)
dEL
(delete)
not.dEL (not delete)
dEL
not.dEL
on
oFF
(delete)
(not delete)
(reset)
(not reset)
Save number 01 ~ 20
Save number 01 ~ 20
(*1) Time has been adjusted to Japanese local time at the shipment.
(*2) A message on is displayed on the LCD when powering on the instrument
while the formatted CF card has been inserted.
(*3) Format a CF Card before use.
Item number
Setting screen
STEP 2
STEP 3
STEP 4
keys.
Press the
key on the selected item.
(Then settings blink and the instrument gets setting change mode.)
Change the settings with
keys.
< Example>
Item number [01], Setting item [Wiring]
Setting [1P2W(1ch)/ 1P2W(2ch)/ 1P2W(3ch)/ 1P3W/ 3P3W/ 3P4W]
or
or
STEP 5
3P3W
1P3W
3P4W
1P2W(3ch)
STEP 5
key.)
1P2W(1ch)
1P2W(2ch)
key.)
4. Wiring (Section 5)
VN
V1
V2
V3
A1
A2
A3
L
N
LOAD1
VN V1
A1
L
N
LOAD1
LOAD2
SOURCE
L
N
VN V1
A1
A2
LOAD1
LOAD2
LOAD3
VN V1
A1
A2
A3
SOURCE
L1
N
L2
VN V1 V2
LOAD
L1
L2
L3
A1
A2
LOAD
VN V1 V2
A1
A2
SOURCE
L1
L2
L3
N
VN V1 V2 V3 A1
LOAD
A2
A3
(Section 6)
Setting 01 Wiring
Setting 02 Voltage range
Setting 03 Current range
Setting 04 Clamp sensor
Setting 05 VT ratio (if necessary)
Setting 06 CT ratio (if necessary)
W range
Wiring
Instantaneous value
measurement
Displayed items on W range
Voltage (RMS)
Current (RMS)
Active power
Reactive power
Apparent power
Power factor
Frequency
Neutral current
Displayed parameters
V : Average voltage of Vi
Vi : Voltage per phase
A : Average current of Vi
Ai : Current per phase
P : Total active power
Pi : Active power per phase
Polarity: + (no mark) consumption,
- (minus) regenerating
Q : Total reactive power
Qi : Reactive power per phase
Polarity: + (no mark) phase lag,
- (minus) phase lead
S : Total apparent power
Si : Apparent power per phase
PF : Total power factor
Pfi : Power factor per phase
Polarity: + (no mark) phase lag,
- (minus) phase lead
f : Frequency at V1
In : Current on a neutral line (only at three-phase 4-wire)
**
Unit
V
A
W
Var
VA
PF
Hz
An
* i = 1, 2, 3
** : The recorded/displayed In(neutral current) value will not be a true value in situations where
there is an earth leakage or leakage current flowing through the live conductors of the three
phase system that is being monitored using the Power Meter Model 6300.
9
Upper : V
Middle : A
Lower : P
X Axis
A
(1-A)
1
V
A
P
(2-A)
P
S
PF
(3-A)
V1
V2
V3
B
(1-B)
V1
A1
P1
(2-B)
P1
S1
PF1
(3-B)
A1
A2
A3
C
(1-C)
V2
A2
P2
(2-C)
P2
S2
PF2
(3-C)
P1
P2
P3
D
(1-D)
V3
A3
P3
(2-D)
P3
S3
PF3
(3-D)
PF1
PF2
PF3
(3-E)
S1
S2
S3
(3-F)
Q1
Q2
Q3
(3-G)
f
In
-
1P2W
(1ch)
9 screens
1P2W
(2ch)
13 screens
1P2W
(3ch)
15 screens
1P3W
13 screens
3P3W
13 screens
A
V
A
P
P
S
PF
V
V
A
P
P
S
PF
V
V
A
P
P
S
PF
V
V
A
P
P
S
PF
V1
V2
V
A
P
P
S
PF
V1
V2
-
A
V
A1
P1
P1
S1
PF1
A1
A2
V
A1
P1
P1
S1
PF1
A1
A2
A3
V1
A1
P1
P1
S1
PF1
A1
A2
V1
A1
P1
P1
S1
PF1
A1
A2
-
P
V
A2
P2
P2
S2
PF2
P1
P2
V
A2
P2
P2
S2
PF2
P1
P2
P3
V2
A2
P2
P2
S2
PF2
P1
P2
V2
A2
P2
P2
S2
PF2
P1
P2
-
PF
-
S
-
Q
-
f
-
PF1
PF2
V
A3
P3
P3
S3
PF3
PF1
PF2
PF3
S1
S2
-
Q1
Q2
-
f
-
S1
S2
S3
Q1
Q2
Q3
f
-
PF1
PF2
-
S1
S2
-
Q1
Q2
-
f
-
PF1
PF2
-
S1
S2
-
Q1
Q2
-
f
-
11
W range
File number
Pressing the
W range
mark is displayed.
(file is opened)
mark is displayed
for about one second.
Closing a file
Set the Function switch to any position other than W and OFF.
Display screen
on other range
mark disappears
key
mark.
(Section 7)
Setting 01 Wiring
Setting 02 Voltage range
Setting 03 Current range
Setting 04 Clamp sensor
Setting 05 VT ratio (if necessary)
Setting 06 CT ratio (if necessary)
W range
Wiring
SET UP range
Confirmation of
instantaneous value
Setting for Integration
measurement
Wh range
Instantaneous value
measurement
Items displayed on Wh range
Active electrical
energy (consumption)
Apparent electrical
energy (consumption)
Elapsed time of
integration
Displayed parameters
WP
WP1/WP2/WP3
WS
WS1/WS2/WS3
TIME
13
Unit
Wh
VAh
-
Wh range
(open a file)
Start
Displayed
Flashing
Stand-by
Displayed
Measuring
Manual operation
Press the
key.
(at least for 2 sec.)
Stop
Wh range
Automatic operation
Measurement ends at set time & date
or
Screen 3
Screen 2
or
Displayed at
Upper
Middle
Lower
Upper
Middle
Lower
Upper
Middle
Lower
1P2W (1ch)
1P2W (2ch)
1P3W
3P3W
1P2W (3ch)
3P4W
Screen 4
Displayed contents
Screen1 Screen2 Screen3 Screen4
TIME
WP
WS
TIME
TIME
TIME
WP
WP1
WP2
WS
WS1
WS2
TIME
TIME
TIME
TIME
WP
WP1
WP2
WP3
WS
WS1
WS2
WS3
Electrical energy
Elapsed time
First data point saved
Measurement starts
(manually/automatically)
Measurement ends
(manually/automatically)
15
(Section 8)
Setting 01 Wiring
Setting 02 Voltage range
Setting 03 Current range
Setting 04 Clamp sensor
Setting 05 VT ratio (if necessary)
Setting 06 CT ratio (if necessary)
W range
Wiring
SET UP range
Confirmation of
instantaneous value
Setting for demand
measurement
DEMAND range
Demand value
measurement
Displayed items on DEMAND range
Displayed parameters
Target value
Predicted value
Present value
Load factor
Remaining time
Max. demand value
Unit
W
W
W
%
W
-
DEMAND
range
Start
Displayed
Stand-by
Flashing
Displayed
Measuring
Manual operation
Press the
key.
(at least for 2 sec.)
Stop
DEMAND
range
(close a file)
, the
Automatic operation
Measurement ends at set time & date
mark disappear and LED status
or
or
(W)
Inspection
cycle
Demand interval
Demand interval
0
Demand measurement starts
(manually/automatically)
: Demand value
(Present value)
: Max. demand value
(indicated on the LCD)
: Data saving point
Elapsed time
Demand measurement stops
(manually/automatically)
18
19
Reactive
power
Apparent
power
Power
factor
Frequency
Parameters recorded
Vi
: Voltage per phase
Vi max : Each max. value of Vi
Vi avg : Each average value of Vi
Ai
: Current per phase
Ai max : Each max. value of Ai
Ai avg : Each average value of Ai
P
: Total active power
Pi
: Active power per phase
P max : Max. value of P
Pi max : Each max. value of Pi
P avg : Average value of P
Pi avg : Each average value of Pi
Q
: Total reactive power
Qi
: Reactive power per phase
Q max : Max. value of Q
Qi max : Each max. value of Qi
Q avg : Average value of Q
Qi avg : Each average value of Qi
S
: Total apparent power
Si
: Apparent power per phase
S max : Max. value of S
Si max : Each max. value of Si
S avg : Average value of S
Si avg : Each average value of Si
PF
: Total power factor
PFi
: Power factor per phase
PF max : Max. value of PF
PFi max : Each max. value of PFi
PF avg : Average value of PF
PFi avg : Each average value of PFi
f
: Frequency of V1
In
: Neutral current
Neutral
f max : Max. value of f
In max : Max. value of In
current
f avg : Average value of f
In avg : Average value of In
+WP
: Total active electrical energy(consumption)
+WPi
: Active electrical energy per phase (consumption)
-WP
: Total active electrical energy (regenerating)
-WPi
: Active electrical energy per phase (regenerating)
#WP
: Total active electrical energy(overall)
#WPi
: Active electrical energy per phase (overall)
+WS
: Total apparent electrical energy (consumption)
+WSi
: Apparent electrical energy per phase (consumption)
-WS
: Total apparent electrical energy (regenerating)
-WSi
: Apparent electrical energy per phase (regenerating)
#WS
: Total apparent electrical energy(overall)
#WSi
: Apparent electrical energy per phase (overall)
Active
electrical
energy
(consumption)
(regenerating)
(overall)
Apparent
electrical
energy
(consumption)
(regenerating)
(overall)
Reactive
electrical
+WQ
energy
(consumption)
#DEMi
* i = 1, 2, 3
max and avg mean maximum value and average value during an interval.
20
MEMO
MEMO