Professional Documents
Culture Documents
USERS MANUAL
Issue date : 2/4/2009
INSTRUCTIONS
CO120/6.4-C/O
Comm. No.:
ECC39282-01
Customer:
PRAXAIR
Order No.:
186-LFPSG/DM
The purpose of these instructions is to facilitate the operation of your pump and to avoid
errors. Reading these instructions carefully before installation and start-up means safeguarding your interests and will be repaid by satisfactory service and performance of the
machine and low cost of repair.
We recommend you to keep on stock all spare parts mentioned in these instructions and
would be grateful if, when placing orders for spares, you would use our designation and
indicate the number of your pump. You will find the machine number of the name plate of
each pump.
Manufacturer
Cryostar-USA
9211 S. Greenleaf Ave.
Santa Fe Springs , CA 90670
Telephone:
fax:
Telephone :
fax :
(484) 281-3401
(484) 281-3402
(562) 903-1290
(562) 903-4511
Page 2
USERS MANUAL
Issue date : 2/4/2009
GLOBAL LOCATIONS
CRYOSTAR FRANCE S.A.
GLOBAL HEADQUARTERS
Zone Industrielle
B.P. 48
Hesingue
F-68221 HEGENHEIM CEDEX
Tel: +33(3) 89 70 27 27
Fax: +33(3) 80 67 59 54
CRYOSTAR SINGAPORE
CRYOSTAR UK
USER RESPONSABILITY
This equipment will perform in accordance with the instructions and information contained in this manual, and
its referenced documents, when such equipment is installed, operated and maintained in compliance with
such instructions. The equipment must be checked periodically. Defective equipment shall not be used. Parts
that are brocken, missing, plainly worn, distorted or contaminated shall be replaced immediately. Should such
repair or replacement become necessary, CRYOSTAR recommends that a request for service will be made.
We recommend you to keep on stock all spare parts mentioned in these instructions. At the end of the manual
we indicate how to put in an ordre for spares.
The equipment, or any of its parts, shall not be altered without the prior written approval of CRYOSTAR. The
user and /or purchaser of this equipment shall have the sole responsibility for any malfunction which results
from improper use, faulty maintenance, damage, the use of spare parts that are not from CRYOSTAR,
improper repair or alteration by any party other than the manufacturer.
Attention
It is essential to read the directions for use prior to unpacking and installation.
Moreover, the machine must be used and maintained by qualified personnel.
Note
This document is the property of BOC-AG Cryostar. It is not permitted to copy it, or to relate its contents to
other persons, or to misuse it in any other way.
TABLE OF CONTENTS
Page 3
USERS MANUAL
Issue date : 2/4/2009
1. TECHNICAL DATA
1.1. Pump data
1.2. Operating data
1.3. Motor data
1.4. Acoustic pressure
1.5. Test
1.6. Description of the Design
2. SAFETY
2.1. Warning
2.2. Isolation and energy dissipation
2.2.1. Isolation and dissipation of gas process energy
2.2.2. Isolation and dissipation of purging gas energy
2.2.3. Isolation and dissipation of electrical energy
2.3. Safety form for oxygen pump
2.4. Customer safety instructions - Summary
4. INSTALLATION
4.1. Handling
4.2. Erection
4.3. Installation Scheme
4.4. Storage Tank
4.5. Piping
4.5.1. Suction Line
4.5.2. Discharge Line
4.5.3. Bypass Line
4.5.4. Vent Line
4.6. Valves and Fittings
5. LUBRICANTS
5.1. Characteristics
6. START-UP
6.1. Pre-Start-Up Inspection
6.1.1. Spin Test by Hand
6.1.2. Direction of Rotation
6.1.3. Vent
6.1.4. In labyrinth pump : centering labyrinth rings
6
6
6
6
6
7
8
9
9
10
11
11
11
12
14
16
16
16
16
16
17
17
17
17
17
18
18
19
20
20
20
21
21
22
22
22
22
22
22
Page 4
USERS MANUAL
Issue date : 2/4/2009
23
24
25
7. TROUBLE SHOOTING
26
8. MAINTENANCE INSTRUCTIONS
29
8.1. General
8.1.1. Assembly / Disassembly : Table of tightening torques and forces
8.2. Periodical Revisions and Maintenance
8.3. Dismantling of the pump
8.4. Assembly of the Pump
8.5. Adjustment of the Mechanical Seal
10. ANNEX
10.1. NPSH
10.2. Appendix to spare parts lists
10.3. Documentation
29
29
31
32
32
33
34
34
35
35
37
38
Page 5
USERS MANUAL
Issue date : 2/4/2009
DRAWING TITLE
DRAWING
NUMBER
Flow diagram
Handling drawing
Dimensional drawing
Performance curve
Top Assembly
Special tools
Checklist
705070145
708114352
702114258-01
Test curve
763150972-02
763026005
706110196
SPARE PART
LIST NUMBER
E763150972-02
Page 6
USERS MANUAL
Issue date : 2/4/2009
1.
TECHNICAL DATA
1.1.
Pump data
Serial number
Type
Number of stages
Nominal impeller diameter
Speed
Position of suction nozzle
Position of discharge nozzle
Material Execution
Year / Month built
1.2.
Operating data
Medium
Liquid temperature
Max. Suction pressure
Minimum NPSH
Flow rate
Differential head
1.3.
LN2
-196C
5 barg
0.6 m
25 gpm
380 ft
Motor data
Cryostar ref.
Type
Protection
Insulation class
Temperature rise
Frequency
Phase
Voltage
Power
Speed
Forced ventilation
1.4.
ECC39282-01
CO120-6.4 C/O
1
120 mm
6400 rpm
Axial
I
Bronze / Bronze
2007 / 12
792605195-01/004
213T NEMA
IP 55
F
B
104 Hz
3
460 V
10 HP
6400 rpm
3x480V, 60 Hz
Acoustic pressure
Average value
85 dB A
Page 7
USERS MANUAL
Issue date : 2/4/2009
1.5.
Test
Medium
Test speed
Nitrogen
Refer to acceptance report
Note :
Working data have been measured at the test stand.
The test allows pressure to be checked under cryogenic working conditions.
Note : if required, test protocoles, material certificates or pressure test certificates are
included in the quality data book depending on the contract conditions.
Page 8
USERS MANUAL
Issue date : 2/4/2009
1.6.
Page 9
USERS MANUAL
Issue date : 2/4/2009
2.
SAFETY
2.1.
Warning
Page 10
USERS MANUAL
Issue date : 2/4/2009
Burning hazard !
During cool-down and working periods, it is strictly forbidden to touch
the machine
(Maintenance)
Our products must be installed in a unit which ensures all functions of
cutting, separation, locking, pressure purging and checking
All energy external to our product originating from the customer (electricity,
purging gas, compressed air, N2-purging, etc...) must be isolated and
dissipated by means of isolating switches (hand operated valves with
padlocks, locking electric switches..). Gas line valves must be chosen
Page 11
USERS MANUAL
Issue date : 2/4/2009
Components and instruments which permit the isolation and the dissipation of
the gas process energy depend on the users internal procedures of isolation
and energy dissipation and the parameters of their networks. Thus, it is not
possible for CRYOSTAR to plan the installation of this type of equipment on
the supplied machine.
2.2.2.
The user must ensure that all purging pipes have been isolated before any
operation on the product.
2.2.3.
Page 12
USERS MANUAL
Issue date : 2/4/2009
2.3.
Physical properties:
. Formula :
. Atomic number
. Molecular weight :
. Molecular dimensions :
. First ionization potential :
. Gas density S.T.P. :
O2
Z=8
31.9988 g.mole-1
4,2-2,8
12.059 eV
1,4289 kg.m-3
Working recommendations :
. No smoking near the pump.
. Oil and grease stained clothing must not be worn.
. Greasy rags should not be left lying about and the floor must be free of oil stains.
. Work with flame should be avoided in the enclosure of the pump.
Page 13
USERS MANUAL
Issue date : 2/4/2009
Page 14
USERS MANUAL
Issue date : 2/4/2009
2.4.
AVERTISSEMENT
Toutes les interventions doivent tre
effectues par un personnel habilit
ACHTUNG
Alle Arbeiten mssen von
entsprechend geschultem Personal
ausgefhrt werden
LIFTING
Vertical lifting : prevent uncontrolled
rotation
LEVAGE
Levage vertical : Empcher toute
rotation non contrle
HEBEN
Senkrechtes Heben : unkontrolliertes
Drehen vermeiden
PRE-INSTALLATION CHECKS
CONTRLES AVANT
INSTALLATION
Toute pompe doit tre contrle ds
rception
Typenschilddetails prfen
No loose fasteners
MECHANICAL INSTALLATION
Gaskets and seals correctly mounted
INSTALLATION MECANIQUE
Montage correct des joints et
garnitures
MECHANISCHE INSTALLATION
Korrekte Montage von Dichtungen
und Gleitringdichtungen
Refer to instructions
Siehe Betriebsanleitung
ELECTRICAL INSTALLATION
All operations must be carried out by
appropriately trained personnel
INSTALLATION ELECTRIQUE
Toutes les interventions doivent tre
effectues par un personnel habilit
ELEKTRISCHE INSTALLATION
Alle Arbeiten mssen von
entsprechend geschultem Personal
ausgefhrt werden
Earthed
Mis la terre
geerdet
Page 15
USERS MANUAL
Issue date : 2/4/2009
Abdeckungen zumachen
ANSCHLUESSE
Anschlsse nach Anschlussplan
berprfen
PROBLEMS
Pump does not prime
PROBLEMES
La pompe naspire pas
Fuites garniture
Gleitringdichtung undicht
Vibrations
Vibrations
Pumpe vibriert
Moteur surcharg
Bearings overheated
Roulements schauffent
Refer to supplier
Consulter le fournisseur
Hersteller fragen
MAINTENANCE
Isolate
ENTRETIEN
isoler
WARTUNG
trennen
SPARES
Refer to supplier
PIECES DE RECHANGE
Consulter le fournisseur
ERSATZTEILE
An Hersteller wenden
Maschinennummer,
Zeichnungsnummer, Benennung
angeben
HAZARDOUS AREAS
All operations must be carried out by
appropriately trained personnel
ZONES DANGEREUSES
Toutes les interventions doivent tre
effectues par un personnel habilit
GEFAHRENBEREICHE
Alle Arbeiten mssen von
entsprechend geschultem Personal
ausgefhrt werden
Refer to:
construction standard EN 294
Se reporter :
norme de construction EN 294
Bitte nachschlagen in :
Baunorme EN 294
STORAGE
Storage in a dry environment
the right way round
STOCKAGE
Stockage en lieu sec
lendroit
LAGERUNG
Lagerung in trockenem Raum
Richtig stellen
CONNECTIONS
Check connection diagram
Page 16
USERS MANUAL
Issue date : 2/4/2009
3.
3.2.
3.3.
3.4.
Page 17
USERS MANUAL
Issue date : 2/4/2009
4.
INSTALLATION
4.1.
Handling
Every machine that weights more than 55 kg must only be handled with a
Handling System. Please refer to Handling drawing.
PUMP TYPE
Weight 500 Kg
Pump with gearbox
Weight 500 Kg
Pump without gearbox
VCS
LOX
CBSH
4.2.
Erection
Place skid on a flat surface that has been prepared according to the
dimensional layout drawing and capable of supporting the indicated load.
Secure the skid to the surface with the required amount and size of bolts as
indicated in the foundation drawing. The skid to be preferably grouted to limit
vibration. The stability of the whole installation must be ensured.
4.3.
Installation Scheme
The enclosed installation schematic drawing and operating instructions on the
following pages apply in normal operating circonstances only. Therefore, they
are relatively general and only the most important points for all different
service applications are mentioned. The installation schematic drawing shows
only indispensable equipment and piping for the operation of a pump for
liquefied gases and should be completed accordingly for different applications.
4.4.
Storage Tank
Most suitable is a pressurised storage tank which maintains the required
NPSH of the pump (see par. 10.1). The machine must be installed as close as
possible from the tank.
The tank discharge connection should be in the bottom of the tank and short.
A syphon or plunging pipe are unsuitable as gas which is formed in the line is
collected and cannot leave the pipe.
Page 18
USERS MANUAL
Issue date : 2/4/2009
The diameter of the tank discharge connection should be adjusted to the flow.
It should not be too small (minimum diameter same as the pump suction
connection) to keep the pressure drop small.
4.5.
Piping
Piping must be carefully designed so as not to transmit any stresses or forces
to the pump during operation or during stand still. Temperature contractions
and elongations must also be taken into consideration. For this reason,
flexible pipe parts should be installed.
4.5.1.
Suction Line
The suction line connects the tank discharge and the pump suction connection
and should be as direct and as short as possible.
The pipe must have a constant downwards inclination to the pump to allow
forthcoming gas to return into the tank.
The pipe diameter should be selected and designed for flow with an average
velocity of approx. 1 m/sec. Smaller velocities reduce the friction losses, but
disadvantageously increase the heat inleak accordingly. This reduces the
available NPSH (see
par. 10.1) and increases the gas vaporization loss during the cool down
period.
Good insulation is therefore essential. But it should not hinder the movements
of flexible pipe parts (flexible hose).
In view of gas vaporization losses the shut-off valves and the filter should not
be too large, as larger sizes mean increased heat inleak and longer cool down
time.
Pumps for oxygen service must be protected against foreign particles by a
filter in the suction line. Particles, which enter the pump are a potential fire or
explosion hazard.
The filter should have approx. 560 micron mesh and the useful surface should
be two times the suction pipe area at minimum.
Manifolds without a constant liquid flow should be shut-off as close as
possible to the branch in order to minimize the liquid gas vaporization.
All piping sections which can be shut-off must be equipped with safety valves
to avoid excessive pressure increase due to the vaporization of liquid gas.
Page 19
USERS MANUAL
Issue date : 2/4/2009
a) Shut-off valve
b) Safety valve
c) Flexible pipe section
d) Filter for oxygen service (only if the pump is used with oxygen)
e) Non-return valve on the pump discharge
Recommendations
Flexible elbow
Lack or filter or safety valve
Trouble
Pressure drop
Pressure drop
Pressure drop and heat inleak
Gas formation, the gas will be sucked
into the pump or the suction line will be
clogged
Gas accumulation, gas bubbles will be
sucked into the pump or the suction line
will be clogged
Additional force
Pump or seal failure possible
Discharge Line
The discharge pipe should have the same diameter as the discharge
connection of the pump, or somewhat larger for longer piping and when
excessive pressure loss would restrict the flow too much.
Page 20
USERS MANUAL
Issue date : 2/4/2009
The discharge line characteristic must be put into consideration with the pump
characteristic curve!
A shut-off valve, a non-return valve and pressure gauge should be installed in
the discharge line.
4.5.3.
Bypass Line
For faster cool down and for easier start-up a bypass line should be provided.
The bypass pipe should have the same diameter as the pump discharge line
or should be designed for the pump minimum flow.
4.5.4.
Vent Line
A vent pipe with shut-off valve is advantageous for the venting of piping and
pump and for faster cool down.
4.6.
Page 21
USERS MANUAL
Issue date : 2/4/2009
5.
LUBRICANTS
The following lubricants should be used:
Motor-bearing Grease
ESSO Beacon 325
ESSO Beacon 325
Caution:
Because of explosion risk, do not use normal, commercially mineraloil-based
lubricants for oxygen service.
5.1.
Characteristics
CHARACTERISTICS
Appearance
Soap base
Temperature range
Base oil
Kin. viscosity
at 40C
at 100C
Drop point
Penetration-unworked
Penetration-worked x60
Bearing performance against corrosion
Test NF T 60-135
Resistance to water washing out at 40C
Loss
Tests on bearings at high temperature
Test FTMS 791 b-331-2 at 120C
Vaporization losses
Test ASTM D 972 (22 h 121C), loss
AVERAGE VALUE
creamy smooth grease
Lithium
-55 to 120C
synthetic ester
cSt
cSt
C
11.8
3.25
180
260
280
0
% wt
>1000
% wt
0.5
Page 22
USERS MANUAL
Issue date : 2/4/2009
6.
START-UP
6.1.
Pre-Start-Up Inspection
Check whether all pipes, fittings, fixing bolts and electric connections are
ready for start-up.
Prepare the complete system, in which the pump is installed for start-up.
For gearbox driven pumps, check the oil level.
6.1.1.
Spin the pump by hand using the slinger ring on the pump shaft or an offset
spanner on the motor fan screw to control the rotation.
6.1.2.
Direction of Rotation
Start the motor for a short run (the pump must not be operated without liquid!)
and check whether the pump shaft rotation is the same as the arrow direction
on the pump volute.
6.1.3.
Vent
CAUTION
BEFORE OPERATING THE PUMP, ALL SUCTION LINES, DISCHARGE
LINES AND THE PUMP SHOULD BE VENTED SO AS TO PREVENT
HUMIDITY OR ICE FROM BUILDING-UP IN THE PUMP DURING THE
COOL DOWN PERIOD
THE LENGTH OF TIME FOR THIS WILL VARY DEPENDING UPON LOCAL
CONDITIONS : ONE DAY MINIMUM after a long break
6.1.4.
Caution : For labyrinth pumps, loosen the labyrinth seal cover screws. Turn
pump on end i.e. rotate the shaft manually to ensure that it rotates
correctly and to ensure the self-centering of the labyrinth rings. Then, the
cover screws of the labyrinth seal may be definitively tightened-up.
Page 23
USERS MANUAL
Issue date : 2/4/2009
6.2.
WARNING
The pump must not run without liquid!
Safety clothes, gloves, spectacles, etc... according to On-Site regulations
Page 24
USERS MANUAL
Issue date : 2/4/2009
When cooling down, start the pump every 2-3 minutes for a short run of 2 to 3
seconds. This prevents contact freezing of the sealing surfaces.
During cool-down the storage tank pressure rises. This improves the pump
start-up conditions due to improved NPSH - see section NPSH.
When a ventline with block-valve against air inlet is installed in the discharge
or bypass line, cool-down can be accelerated by venting the gas into the
atmosphere. Do not open the shut off valve for too long a period, otherwise
the storage tank pressure will drop too much.
Normally the pump will be cooled down after 10-15 minutes.
The white frost from the pump body then begins to extend to the four support
arms. If the pump is overcooled (support arms completely frosted) it should be
started only after the shaft has been checked for freedom of rotation.
After the pump is well cooled down fully open the suction valve. If one is
installed, close the ventline and block valve and regulate the bypass valve
according to the diameter of the pipe. Start the pump.
Adjust to the required discharge pressure with bypass valve 6. Then
simultaneously open pressure regulating valve 4 and close bypass valve 6.
This starts liquid gas delivery to the consumer.
Do not control the flow with the suction shut off valve! This valve must remain
fully open during operation. Partial closure will decrease the available NPSH
and could disturb the trouble free operation.
6.3.
Page 25
USERS MANUAL
Issue date : 2/4/2009
The pump mechanical seal is designed for a suction pressure of 5 bars. Keep
the pump suction pressure as low as possible. This improves the life time of
the mechanical seal.
6.4.
Page 26
USERS MANUAL
Issue date : 2/4/2009
7.
TROUBLE SHOOTING
Trouble
Probable Cause
Trouble Shooting
Insufficient cool-down
or the priming is
or increase suction
lost
pressure (NPSH)
(insufficient NPSH)
Vapor pocket in the
suction line
Contamination in the
pump
Worn-out parts
Repair/overhaul cold
end
Wrong direction of
rotation
leads on motor
Mechanical seal
leaking
too high
suction pressure to
prescribed value
to prescribed value
worn-out
Page 27
USERS MANUAL
Issue date : 2/4/2009
Trouble
Probable Cause
Trouble Shooting
Rated capacity
Improve suction
well
achieved
suction filter
Vapor in suction line
NPSH not sufficient
Impeller or volute
passages clogged
parts
Exchange worn or
impeller damaged
damaged parts
system characteristic
rated
cient
Pump noisy, internal
rubbing noise
Flow higher than rated
Low voltage
Increase voltage to
rated value
Page 28
USERS MANUAL
Issue date : 2/4/2009
Trouble
Probable Cause
Trouble Shooting
Pump vibration
Pump cavitating
minimum recommended
minimum value
flow
Impeller clogged, un-
balance
ting parts
Improve fixation
and/or foundation
Exchange worn-out
parts
Use prescribed
heated or wearing
rapidly
preload
Improper lubrication
Improve lubrication,
check lubricant flow
passages
Dirt or water in
Clean or exchange
bearings
bearings
Reduce vibration as
prescribed above
Page 29
USERS MANUAL
Issue date : 2/4/2009
8.
MAINTENANCE INSTRUCTIONS
8.1.
General
The following maintenance instructions are sufficient in normal use.
Estimates and proposals for spare parts and revisions will be supplied upon
request.
Nevertheless it is not recommended nor practical to attempt to completely
overhaul it due to the close tolerances and precision finishes of the interior
components.
When extensive overhaul works or complete revisions are necessary, we
recommend that the help of our service engineer is requested.
WARNING
Before use, ensure that the pump is not under voltage and that it is not cold. If
necessary, the installation must be isolated and the energy must be dissipated
according to safety procedures.
WARNING
Before use, ensure that no impurity enters into the pump or the pipes.
8.1.1.
After manual tightening, the end tightening must be made with a torque
wrench, at 75% of the limit of elasticity or at the drawing value.
Page 30
USERS MANUAL
Issue date : 2/4/2009
Torques and forces for Bolts of type H, in stainless steel, class A1, A2, A4
Bolts class of resistance: 70
M6
M8
M10
M12
M14
M16
M18
M20
M22
M24
M27
M30
Torque (Nm)
Max
5.9
14.5
30
50
79
121
174
244
182
234
328
445
Standard
5
12
25
42
66
101
145
203
152
195
273
371
Force (Nm)
Max.
6.85
12.6
20
29.1
40
55
69
88.6
61.5
70.9
90
109.4
Standard
6
11
17
24
33
46
58
74
51
59
75
91
M6
M8
M10
M12
M14
M16
M18
M20
Torque (Nm)
Max
8
19.3
39.4
67
106
161
232
325
Standard
7
16
33
56
88
134
193
271
Force (Nm)
Max.
9.13
16.7
26.6
38.8
53.3
73.3
92
118.1
Standard
8
14
22
32
44
61
77
98
Torques (Nm) for hexagon socket flat or small head cap screws in stainless
steel, class A2, A4
Screw
type
M6
M8
M10
M12
M14
M16
M18
M20
M22
M24
Din 6912
Chc
70
Max
5
12
24
40
66
110
Standard
4
10
20
33
55
92
170
142
Din 7991
Fhc
70
Max.
5
7
21
30
66
Standard
4
6
18
25
0
55
Din 7991
FHc
70
Max
5
8
20
33
50
55
Standard
4
7
17
28
42
46
120
100
75
63
235
196
200
167
Page 31
USERS MANUAL
Issue date : 2/4/2009
8.2.
The time limits given above should be adapted to the type of pump operation,
the atmospheric exposure, the internal operating practice and operating
experience. The given time limits are a recommendation only.
Page 32
USERS MANUAL
Issue date : 2/4/2009
8.3.
8.4.
Page 33
USERS MANUAL
Issue date : 2/4/2009
Page 34
USERS MANUAL
Issue date : 2/4/2009
9.
Order Instructions
Lists of spare parts are enclosed with these instructions. On each sectional
drawing, the spare parts are marked with item numbers corresponding with
those on the spare parts list; on the spare parts list, stock part number and
designation are added to each item.
It is advisable to always keep in stock the spare parts recommended in these
lists; you may save unwelcome waiting time.
When ordered the spare parts, please indicate the following:
1.Equipment number
2.Stock number of the required part
3.Designation of the required part
Page 35
USERS MANUAL
Issue date : 2/4/2009
10.
ANNEX
10.1. NPSH
NPSH = Net positive Suction Head = difference between the static
pressure (Ps) and the actual vapour pressure (Pt) of the vapourfree liquid
in the suction nozzle of the pump.
To allow a cryogenic pump to start and operate correctly, a specific NPSH
must be available.
The NPSH in the suction nozzle of the pump has to prevent local vaporization
of the liquid and can also be described as relative undercooling ( DT). The
actual vapour pressure (Pt) is determined only by the temperature (Ts) in the
suction nozzle of the pump, expressed in meters of liquid head.
Page 36
USERS MANUAL
Issue date : 2/4/2009
Page 37
USERS MANUAL
Issue date : 2/4/2009
Ref. No.
Explanation
Position on drawing
IMPORTANT :
Stock number
Page 38
USERS MANUAL
Issue date : 2/4/2009
10.3. Documentation
CRYOSTAR Ref.
DESIGNATION
CRYOSTAR DOC.
Safety valves must be set every year
LEAFLETS
792605195-01/004
Motor
Leroy Sumer
56
1.000
quantity
Unit
Factor
P/N
Description
Material
Dimentions
Created:14DEC07
Updated:14DEC07
Valid BOM
by:ORTEGAC
Page:
1.000 740150336
PC
Plate Insulating
---------------------------------------------------------------------------------------------------------------------------------------002
1.000
1.000 769111843
PC
Welded support
---------------------------------------------------------------------------------------------------------------------------------------003
1.000
1.000 740081885
C
PC
Pump casing (from casting)
---------------------------------------------------------------------------------------------------------------------------------------004
1.000
1.000 798160823
PC
Spiral wound gasket
---------------------------------------------------------------------------------------------------------------------------------------005
1.000
1.000 740150332
PC
Casing Cover CO120
---------------------------------------------------------------------------------------------------------------------------------------006
1.000
1.000 740108277
PC
Isolating ring
---------------------------------------------------------------------------------------------------------------------------------------007
1.000
1.000 730000169
PC
O-ring
---------------------------------------------------------------------------------------------------------------------------------------008
1.000
1.000 798250060
PC
Mechanical seal
---------------------------------------------------------------------------------------------------------------------------------------009
1.000
1.000 740026827
B
Sealing ring
PC
---------------------------------------------------------------------------------------------------------------------------------------010
1.000
1.000 740104736
PC
Shim
---------------------------------------------------------------------------------------------------------------------------------------011
1.000
1.000 740026828
E
PC
Shim
---------------------------------------------------------------------------------------------------------------------------------------012
2.000
1.000 795080919
PC
KEY
---------------------------------------------------------------------------------------------------------------------------------------013
1.000
1.000 740027146
B
PC
Impeller from casting
---------------------------------------------------------------------------------------------------------------------------------------014
1.000
1.000 740026826
C
PC
Inducer
---------------------------------------------------------------------------------------------------------------------------------------015
1.000
1.000 740150333
PC
Shaft CO120
---------------------------------------------------------------------------------------------------------------------------------------016
1.000
1.000 740111839
PC
Slinger ring shaft
---------------------------------------------------------------------------------------------------------------------------------------017
1.000
1.000 730001637
PC
Hexagon socket set screw cone point
----------------------------------------------------------------------------------------------------------------------------------------
001
Pos
User: ROBLEDS
1.000
quantity
Unit
Factor
P/N
Description
Material
Dimentions
Created:14DEC07
Updated:14DEC07
Valid BOM
by:ORTEGAC
Page:
1.000 795080954
PC
Spring type straight pin
---------------------------------------------------------------------------------------------------------------------------------------019
1.000
1.000 709058819
A
PC
Hexagon socket head cap screw
---------------------------------------------------------------------------------------------------------------------------------------020
1.000
1.000 795061119
PC
Conical spring washer
---------------------------------------------------------------------------------------------------------------------------------------021
1.000
1.000 72AP01002
ML
Wire
---------------------------------------------------------------------------------------------------------------------------------------022
8.000
1.000 730150315
PC
SCREW, HEX HEAD, M8 x 30MM SS
---------------------------------------------------------------------------------------------------------------------------------------023
8.000
1.000 730002188
PC
Spring washer
---------------------------------------------------------------------------------------------------------------------------------------028
4.000
1.000 730150314
PC
SCREW, HEX HD, 1/2"-13 x 1.25" SS
---------------------------------------------------------------------------------------------------------------------------------------029
4.000
1.000 730150154
PC
WASHER, LOCK 1/2" , 18-8 SST
---------------------------------------------------------------------------------------------------------------------------------------030
4.000
1.000 769150042
Flex Hose 1/4 ODx10lg
PC
---------------------------------------------------------------------------------------------------------------------------------------031
6.000
1.000 730150309
PC
SCREW, SOCKET HEAD CAP, M10 x 65MM
---------------------------------------------------------------------------------------------------------------------------------------032
6.000
1.000 730000005
PC
Spring washer
---------------------------------------------------------------------------------------------------------------------------------------033
1.000
1.000 792605195-01/004
PC
Asynchron-Motor for variable speed
---------------------------------------------------------------------------------------------------------------------------------------034
1.000
1.000 791564839
PC
Coupling male - BW, conical seal
---------------------------------------------------------------------------------------------------------------------------------------035
1.000
1.000 730150353
PC
NAMEPLATE, CENTRIFUGAL PUMP
---------------------------------------------------------------------------------------------------------------------------------------036
2.000
1.000 740026831
PC
BACK-UP-RING
---------------------------------------------------------------------------------------------------------------------------------------038
2.000
1.000 730150689
PC
PLUG, HEX SOCKET HEAD, 1/8" NPT
========================================================================================================================================
018
Pos
User: ROBLEDS