You are on page 1of 29

Document #: LGD-DIG-0124

Document Rev: B
Effective Date: 11/4/2010

CR145 Installations: CR Installation Worksheet


Customer Name
Date
Installer Name

CR Serial Number
X-Ray Generator Make
X-Ray Tube Make
X-Ray Table Make
System Comments

Notes about color coding of cells


Green
Blue
Tan

Revision History
18-may-10

Test data or measurements are to be entered in these cells


These are intermediate calculation cells- You do not need to change these values
Historical averages or required values are kept here. Do not make changes to these cells.

Original Release

22-jun-10
11-ago-10
29-oct-10

Set exposure values per test data, removed old references to CR140, and corrected error in G
reference
Added minimum exposure data
Corrected 1/40 value to 1/60 in repeatability tests. Increased suggested KV and mR in GT tho

d to change these values


not make changes to these cells.

James Roe

s to CR140, and corrected error in GT Skull/Spine/Pelvis KV

sed suggested KV and mR in GT thorax

James Roe
James Roe
James Roe

System Performance Measurements


1. Warm up the generator with 10 exposures of 80KV and 5mAs.
2. Take measurements at 300mA, 10mAs, 40", Tabletop from 60 to 120KV.
3. Record mR and KV measured in the table below.
4. Verify that the KV is within the control limits on the graph at right.
5. Note the generator performance relative to Standard Frequency and High Frequency systems.

Measured Performance
KV
mR
60
29,2
70
36
80
40,34
90
41,79
100
50,93
110
60,12
120
71,3

KV Actual
60,6
70,6
81,7
93,1
105,1
112,6
122,3

Min. KV
55,5
64,75
74
83,25
92,5
101,75
111

Max. KV
64,5
75,25
86
96,75
107,5
118,25
129

Generator KV Accuracy
+/- 7.5% Threshold
140
130
120

System Exposure Response


10 mAs 40"

110
KV Measured

140
120

Exposure (mR)

100
Column C

80

100

Column
Column
Column
Column

90
80

Column C

D
E
F
C

Column D

60

70

40

60
20

50

0
50

60

70

80

90

100

110

120

130

50

60

70

80

90

100

110

120

130

KV Set

KV

Computation Data (do not change)


KV Predicted line equation
m
1,07
b
-3,76

Corrected KV Line Equation


m
0,93
b
3,51

Exposure Response Predicted Line Equation


mR for 1 mAs
m
0,06
-0,57
b

Predicted Behavior
KV Set KV expected
50
50
60
61
70
71
80
82
90
93
100
103
110
114

Corrected Values
KV needed KV to Set
50
50
60
60
70
69
80
78
90
88
100
97
110
106

Exposure Response
Exposure Response
KV Set
mR per 1 mAs mAs for 1 mR(mR per 1mAs)
60
2,92
0,3425
7
70
3,6
0,2778
80
4,03
0,2479
6
90
4,18
0,2393
100
5,09
0,1963
110
6,01
0,1663
5

mR

Average Generator Performance


Std. Freq.
HF
KV mR
mR
60
13
35
70
19
45
80
26
60
90
34
76
100
42
93
110
51
115
120
65
127

0
60

70

80

90
KV

100

110

120

Measurement of Grid Tray Attenuation


1. Set the system up for a 40" Grid Tray exposure at 10mAs
2. Place the Unfors probe in the center of the bucky, under the table and grid.
3. Take exposures at 60, 80, 100, and 120KV. Record here.
4. The attenuation of the table and grid tray will be calculated and used for gridded exposures.

KV
60
80
100
120

TT
29,2
40,34
50,93
60,43

GT
19,14
25,05
33,54
42,15

Transmission
0,655
0,621
0,659
0,698

Table and Grid Transmission


0,750
0,700

Transmission Coefficient

0,650
0,600
0,550
0,500
0,450
0,400
0,350
0,300
0,250
40

50

60

70

80

90
KV

Computational Data (do not change)

100

Transmission Performance
Interpolation Equation
m
0
b
0,58

Linear plot of interpolation line and Average Performance


KV
60
80
100
120

Transmission
0,634
0,650
0,666
0,683

ded exposures.

Grid Transmission

Column E
Column H
Column I

80

90
KV

100

110

120

130

terpolation line and Average Performance


Average Performance
0,395
0,430
0,465
0,495

mAs vs. mR Measurements


1. Warm up the tube with 5 exposures at 80 KV, 5mAs
2. Set the generator for each of the mAs stations present in the technique chart and record the resulting mR values below.
(These measuments should be made on the tabletop, 40" SID)
3. All mAs stations on the Technique Chart should be included in this test. Adjust or add any additional stations as required.

KV
Setting
80
80
80
80
80
80
80

mA

Seconds

mAs

0
300
300
300
300
300
300

0
1/120
1/60
1/40
1/30
1/20
1/15

0
2,5
5
7,5
10
12,5
15

mR Measured

X-Ray Linearity
80KV, 100cm, 2.5 - 25 mAs
12

10

R^2

X-Ray Linearity

#VALUE!

R^2 > 0.98?

#VALUE!

Exposure (mR)

0
0

10

mAs

System
Repeatability
1. Set
the generator for 80KV, 300mA, 1/40 Second, 5mAs
2. Take 10 exposures and record the mR for each

KV
Setting
80
80

mA
300
300

Seconds
1/60
1/60

mAs
5
5

80
80
80
80
80
80
80
80

300
300
300
300
300
300
300
300

1/60
1/60
1/60
1/60
1/60
1/60
1/60
1/60

5
5
5
5
5
5
5
5

mR Measured

Correlation Coefficient

Average
N
(Xi - Average)^2/(N-1)
"
"
"
"
"
"
"
"
"
Sum(Xi-Avg)
Sqrt(Sum)

#DIV/0!
0
#DIV/0!
#DIV/0!
#DIV/0!
#DIV/0!
#DIV/0!
#DIV/0!
#DIV/0!
#DIV/0!
#DIV/0!
#DIV/0!
#DIV/0!
#DIV/0!

C= #DIV/0!
C < 0.05? #DIV/0!

12

14

16

Tabletop Technique Values


1. Using the Required mAs, insert the closest or higher Generator mAs values to the table below. (mAs to Set column)
2. View each graph below the table. Adjust the mAs and KV so the purple line follows the blue one.
3. Holding mAs to higher values and using lower KV will produce smoother plots.
4. Insert the correct mA values for the required mAs. Note large or small filament as needed.
5. The values in the green columns will be transferred to the technique chart.
EXTREMITIES SKULL SPINE PELVIS SHOULDER

KV to Start
Corrected KV
KV to Set
Minimum Exposure
mR Needed
Best IQ mR Needed
mAs Target
mAs to Set
mR Generated
mA

<4

4-6

6-8

8-10

10-12

58

64

68

70

76

58

63

67

69

74

58

63

67

69

74

10,0

11,0

13,0

15,3

18,0

12,0

13,5

15,7

19,0

23,0

3,6

3,6

4,0

4,5

4,9

3,6

3,6

4,0

4,5

4,9

9,9

11,0

13,1

15,2

18,0

100

100

100

100

100

25,0
20,0
Exposure (mR)

Thickness (cm)

Extr

15,0
10,0
5,0
0,0
<4

THORAX

KV to Start
Corrected KV
KV to Set

<4

4-6

6-8

8-10

10-12

70

73

75

77

69

72

74

75

69

72

74

75

16,0
14,0
12,0

Thickness (cm)

10,0

16,0
14,0

Best IQ mR Needed
mAs Target
mAs to Set
mR Generated
mA

7,0

8,5

10,0

11,5

8,0

10,0

12,0

14,0

2,1

2,4

2,7

3,1

2,1

2,4

2,7

3,1

7,1

8,5

9,9

11,6

100

100

100

100

12,0

Exposure (mR)

Minimum Exposure
mR Needed

10,0
8,0
6,0
4,0
2,0
0,0
<4

ABDOMEN

KV to Start
Corrected KV
KV to Set
Minimum Exposure
mR Needed
Best IQ mR Needed
mAs Target

<4

4-6

6-8

8-10

10-12

58

62

66

70

58

61

65

69

58

61

65

69

8,5

11,5

14,2

16,7

9,5

12,5

16,0

20,0

3,1

3,9

4,5

4,9

25,0

20,0

Exposure (mR)

Thickness (cm)

15,0

10,0

mR Generated
mA

3,1

3,9

4,5

4,9

8,5

11,4

14,2

16,6

100

100

100

100

Exposure (mR)

mAs to Set

15,0

10,0

5,0

0,0
<4

below. (mAs to Set column)

Extremities Skull Spine Pelvis Shoulder Tabletop


25,0

Exposure (mR)

20,0
15,0
Minimum Exposure
mR Needed
mR Generated
Best IQ mR Needed

10,0
5,0
0,0
<4

4-6

6-8
Thickness (cm)

Thorax Tabletop
16,0
14,0

12,0
10,0

8-10

10-12

16,0
14,0

Exposure (mR)

12,0
10,0
Minimum Exposure mR
Needed
mR Generated
Best IQ mR Needed

8,0
6,0
4,0
2,0
0,0
<4

4-6

6-8

8-10

Thickness (cm)

Abdomen Tabletop
25,0

Exposure (mR)

20,0

15,0

10,0

Minimum Exposure mR
Needed
mR Generated
Best IQ mR Needed

10-12

Exposure (mR)

15,0
Minimum Exposure mR
Needed
mR Generated
Best IQ mR Needed

10,0

5,0

0,0
<4

4-6

6-8
Thickness (cm)

8-10

10-12

Exposure
ed
rated
mR Needed

10-12

re mR

ed

sure mR

eded

10-12

sure mR

eded

10-12

Grid Tray Technique Values


SKULL SPINE

KV to Start
Corrected KV
KV to Set
Minimum Exposure
mR Needed
Best Image Quality
mR Needed
mAs Target
mAs to Set
Undertable mR
Generated
mA

10-15

15-20

20-25

25-30

75

77

82

85

74

75

80

83

74

75

80

83

35,0

11,3

16,8

24,3

32,0

30,0

16,0

25,0

34,0

42,0

4,8

7,0

9,3

11,7

4,8

7,0

9,3

11,7

11,4

16,9

24,3

32,0

100

100

100

100

45,0
40,0

Exposure (mR)

Thickness (cm)

Skull S

25,0
20,0
15,0
10,0
5,0
0,0
10-15

THORAX

KV to Start
Corrected KV
KV to Set
Minimum Exposure
mR Needed
Best Image Quality
mR Needed
mAs Target

10-15

15-20

20-25

25-30

78

84

94

100

76

82

91

97

76

82

91

97

9,5

13,0

16,5

19,5

11,5

15,5

20,0

24,0

3,9

4,8

5,4

5,9

25,0
23,0
21,0
19,0
posure (mR)

Thickness (cm)

17,0
15,0

21,0

mAs to Set
Undertable mR
Generated
mA to use

3,9

4,8

5,4

5,9

9,6

12,9

16,5

19,6

100

100

100

100

Exposure (mR)

19,0
17,0
15,0
13,0
11,0
9,0
7,0
5,0
10-15

ABDOMEN

KV to Start
Corrected KV
KV to Set
Minimum Exposure
mR Needed
Best Image Quality
mR Needed
mAs Target
mAs to Set
Undertable mR
Generated
mA

10-15

15-20

20-25

25-30

75

77

82

85

74

75

80

83

74

75

80

83

13,5

19,0

26,0

32,0

15,0

23,0

30,0

37,0

5,7

7,9

10,0

11,7

5,7

7,9

10,0

11,7

13,5

19,0

26,1

32,0

100

100

100

100

40,0

35,0

30,0
Exposure (mR)

Thickness (cm)

25,0

20,0

15,0

10,0
10-15

Exp

20,0

15,0

10,0
10-15

15

Skull Spine Pelvis Shoulder Grid Tray

Minimum Exposure
mR Needed
Undertable mR
Generated
Best Image Quality
mR Needed

15-20

20-25

25-30

Thickness (cm)

Thorax Grid Tray

Minimum Exposure mR
Needed
Undertable mR Generated

15

15

Minimum Exposure mR
Needed
Undertable mR Generated
Best Image Quality mR
Needed

15-20

20-25

25-30

Thickness (cm)

Abdomen Grid Tray

Minimum Exposure mR
Needed
Undertable mR Generated
Best Image Quality mR
Needed

15-20

20-25

25-30

15

Undertable mR Generated
Best Image Quality mR
Needed

15-20

20-25
Thickness (cm)

25-30

Clinica Veterinaria Guayana


Variable 100 mA
14/08/2011
Use 40" 100cm SID for Tabletop and Grid Tray

Anatomy Thickness (cm)


Table Top

Grid Tray

0-4

4-6

6-8

8 - 10

10 - 12

10 - 15

15 - 20

20- 25

25 - 30

Espina,
Craneo

kVp

58

63

67

69

74

74

75

80

83

Pelvis,

mAs

3,6

3,6

4,0

4,5

4,9

4,8

7,0

9,3

11,7

100

100

100

100

100

100

100

100

100

kVp

69

72

74

75

76

82

91

97

mAs

2,1

2,4

2,7

3,1

3,9

4,8

5,4

5,9

mA

100

100

100

100

100

100

100

100

kVp

58

61

65

69

74

75

80

83

mAs

3,1

3,9

4,5

4,9

5,7

7,9

10,0

11,7

100

100

100

100

100

100

100

100

Time
Extremidades

Torax

mA

Time

Abdomen

Time
mA

Table Top

Grid Tray

Support:0243 2420968
2001 2011 IDEXX Laboratories, Inc. All rights reserved.

soportedigital@agrobiotek.com

You might also like