For deeper depth TJi joists, see the Weyerhaeuser deep depth TJi Joist
Specifier's guide, TJ-4005, or contact your Weyerhaeuser representative.
Code evaluations:
ICC ES ESR-1153; ESR-1387
TaBle oF ConTenTS
Design Properties
Floor Span Tables
Material Weights
Floor Load Table
PSF to PLF Conversion Table
TJI Joist Floor Framing
Floor Details
Rim Board Selection
and Installation
Allowable Holes
Cantilevers
Fire-Safe Construction
Understanding and
Preventing Floor Noise
Roof Framing
Roof Details
Cut Length Calculations
Roof Span Table
Roof Load Tables
Framing Connectors
3
4
4
5
5
6
7
8
9
1011
12
12
13
1415
15
16
17
1819
perceived Floor
performance
9966%
%
6633%%
2288%%
25
Custo
mer
Satis
35
facti
on
TTJJ--PP 45
r
roo R
Raattiin 55
ngg PPo
oiinntts
s
65
9999.9.9%
%
8844%
%
March 2014
deSign pRopeRTieS
1"
2116"
1"138"
2516"
1"138"
9"
1178"
14"
38"
1"138"
9"
1178"
14"
16"
38"
2516"
3"
138"
138"
9"
1178"
14"
16"
38"
38"
1178"
14"
16"
716"
1178"
14"
16"
9"
1178"
14"
16"
TJI
Joist
Weight
(lbs/ft)
Maximum
Resistive
Moment (1)
(ft-lbs)
2.3
2.6
2.7
2.5
2.8
3.0
3.0
4.0
2.8
3.1
3.3
3.3
4.2
3.3
3.5
3.5
4.5
2,500
3,000
3,330
3,160
3,795
4,215
6,180
9,500
3,740
4,490
4,990
7,335
11,275
5,140
5,710
8,405
12,925
110
210
230
110
210
230
360
560
110
210
230
360
560
210
230
360
560
Joist Only
El x 10 6
(in. 2-lbs)
Maximum
Vertical
Shear
(lbs)
13 4" End
Reaction
(lbs)
31 2" End
Reaction
(lbs)
157
186
206
267
315
347
419
636
392
462
509
612
926
629
691
830
1,252
1,220
1,330
1,330
1,560
1,655
1,655
1,705
2,050
1,860
1,945
1,945
1,955
2,390
2,190
2,190
2,190
2,710
910
1,005
1,060
910
1,005
1,060
1,080
1,265
910
1,005
1,060
1,080
1,265
1,005
1,060
1,080
1,265
1,220
1,330
1,330
1,375
1,460
1,485
1,505
1,725
1,375
1,460
1,485
1,505
1,725
1,460
1,485
1,505
1,725
Reaction Properties
3" Intermediate
Reaction (lbs)
No Web
Stiffeners
1,935
2,145
2,410
1,935
2,145
2,410
2,460
3,000
1,935
2,145
2,410
2,460
3,000
2,145
2,410
2,460
3,000
With Web
Stiffeners (2)
N.A.
N.A.
N.A.
2,295
2,505
2,765
2,815
3,475
2,295
2,505
2,765
2,815
3,475
2,505
2,765
2,815
3,475
5" Intermediate
Reaction (lbs)
No Web
Stiffeners
2,350
2,565
2,790
2,350
2,565
2,790
3,000
3,455
2,350
2,565
2,790
3,000
3,455
2,565
2,790
3,000
3,455
With Web
Stiffeners (2)
N.A.
N.A.
N.A.
2,705
2,925
3,150
3,360
3,930
2,705
2,925
3,150
3,360
3,930
2,925
3,150
3,360
3,930
(1) Caution: Do not increase joist moment design properties by a repetitive member use factor.
(2) See detail W on page 6 for web stiffener requirements and nailing information.
General Notes
Design reaction includes all loads on the joist. Design shear is computed at
the inside face of supports and includes all loads on the span(s). Allowable
shear may sometimes be increased at interior supports in accordance with
ICC ES ESR-1153, and these increases are reflected in span tables.
pRoduCT
SToRage
om
oist.c 58
TrusJ 53.83
888.4
m
t.co 8
Jois
Trus.453.835
t.com8
Jois .835
Trus.453
888
888
.com
Joist8358
Trus453.
888.
m
t.co 8
Jois.835
Trus.453
com
ist. 58
sJo .83
Tru 53
888
8.4
CAUTION:
Wrap is slippery when wet or icy
88
m
ist.co58
sJo .83
Tru 53
8.4
88
March 2014
117 8"
14"
16"
TJI
110
210
230
110
210
230
360
560
110
210
230
360
560
210
230
360
560
Material Weights
117 8"
14"
16"
TJI
110
210
230
110
210
230
360
560
110
210
230
360
560
210
230
360
560
(1) Web stiffeners are required at intermediate supports of continuous-span joists when the intermediate bearing length is less than
5" and the span on either side of the intermediate bearing is greater than the following spans:
TJI
110
210
230
360
560
Floor Panels
Southern Pine
" plywood . . . . . . . . . . . . . . . . . . . . . . . 1.7 psf
5 8"
11 8"
Roofing
Asphalt shingles . . . . . . . . . . . . . . . . . . . 2.5 psf
Wood shingles . . . . . . . . . . . . . . . . . . . . . 2.0 psf
Clay tile . . . . . . . . . . . . . . . . . . . . 9.0 to 14.0 psf
Slate (3 8" thick) . . . . . . . . . . . . . . . . . . . 15.0 psf
Roll or Batt Insulation (1" thick):
Rock wool . . . . . . . . . . . . . . . . . . . . . . . . . 0.2 psf
Glass wool . . . . . . . . . . . . . . . . . . . . . . . . 0.1 psf
Floor Finishes
Hardwood (nominal 1") . . . . . . . . . . . . . . 4.0 psf
Sheet vinyl . . . . . . . . . . . . . . . . . . . . . . . . 0.5 psf
Carpet and pad . . . . . . . . . . . . . . . . . . . . 1.0 psf
" ceramic or quarry tile . . . . . . . . . . . . 10.0 psf
Concrete:
Regular (1") . . . . . . . . . . . . . . . . . . . . . . 12.0 psf
Lightweight (1") . . . . . . . . . . . . . . 8.0 to 10.0 psf
Gypsum concrete (") . . . . . . . . . . . . . . . 6.5 psf
Ceilings
Acoustical fiber tile . . . . . . . . . . . . . . . . . 1.0 psf
" gypsum board. . . . . . . . . . . . . . . . . . . 2.2 psf
5 8"
Long-term deflection under dead load, which includes the effect of creep, has not been considered. Bold italic spans reflect initial
dead load deflection exceeding 0.33".
General Notes
March 2014
9"
117 8"
14"
16"
TJI
Live
Load
L /480
110
210
230
110
210
230
360
560
110
210
230
360
560
210
230
360
560
*
*
*
*
*
*
*
*
*
*
*
*
*
*
*
*
*
10'
Total
Load
Live
Load
L /480
190
210
236
190
210
236
241
294
190
210
236
241
294
210
236
241
294
140
161
175
*
*
*
*
*
*
*
*
*
*
*
*
*
*
12'
14'
Total
Load
Live
Load
L /480
Total
Load
Live
Load
L /480
152
169
190
152
169
190
193
236
152
169
190
193
236
169
190
193
236
85
99
108
*
*
*
*
*
*
*
*
*
*
*
*
*
*
127
141
158
127
141
158
162
197
127
141
158
162
197
141
158
162
197
56
65
71
92
106
116
136
*
*
*
*
*
*
*
*
*
*
38
45
49
63
74
80
95
138
91
*
115
*
*
*
*
*
*
76
90
99
95
106
119
121
148
95
106
119
121
148
106
119
121
148
45
53
58
69
101
66
76
83
98
*
*
*
*
*
76
92
102
108
132
85
94
106
108
132
94
106
108
132
20'
Live
Load Total
L /480 Load
22'
Live
Load Total
L /480 Load
43
51
76
83
97
119
39
58
78
108
57
62
73
107
76
83
*
*
85
95
97
119
85
95
97
119
47
56
83
58
64
75
*
81
88
108
77
87
88
108
24'
Live
Load Total
L/480 Load
45
91
44
65
81
99
50
59
86
78
81
99
General Notes
1. Calculate actual total and live load in pounds per linear foot (plf).
20
25
12"
16"
19.2"
24"
20
27
32
40
25
34
40
50
55
60
55
74
88
110
60
80
96
120
WaRning
DO NOT walk on joists until braced.
INJURY MAY RESULT.
If a live load deflection limit of L /360 is desired, multiply value in Live Load column
by 1.33. The resulting live load must not exceed the Total Load shown.
Table does not account for concentrated loads. Use Weyerhaeuser software when
this conditionapplies.
WARNING NOTES:
Joists are
unstable
until braced
laterally
1. All blocking, hangers, rim boards, and rim joists at the end supports of the TJI
joists must be completely installed and properly nailed.
Bracing Includes:
Blocking
Hangers
Rim Board
Sheathing
Rim Joist
Strut Lines
3. Safety bracing of 1x4 (minimum) must be nailed to a braced end wall or sheathed
area (as in note 2) and to each joist. Without this bracing, buckling sideways or
rollover is highly probable under light construction loadssuch as a worker or one
layer of unnailed sheathing.
2. Lateral strength, like a braced end wall or an existing deck, must be established at
the ends of the bay. This can also be accomplished by a temporary or permanent
deck (sheathing) fastened to the first 4 feet of joists at the end of the bay.
4. Sheathing must be completely attached to each TJI joist before additional loads
can be placed on the system.
5. Ends of cantilevers require safety bracing on both the top and bottom flanges.
6. The flanges must remain straight within a tolerance of " from true alignment.
March 2014
E1
H2
E2
A1
A3
CS
A2
L3
B1
B2
L5
L1
H1
B3
P1
B4
P2
L2
Safety bracing (1x4 minimum) placed at
8' on-center (6' on-center for TJI 110
joists) and extended to a braced end
wall. Fasten at each joist with two
8d (0.113 x 2") nails minimum.
L4
Structural sheathing
LA
Protect untreated wood
from direct contact
with concrete
1" knockouts
at approximately
12" on-center
H3
WARNING
Joists are unstable until
laterally braced.
See Warning Notes on page 5.
Gap:
18" minimum
2" maximum
1" minimum
bearing
Web stiffener
both sides:
See sizes below
Tight fit
Nailing:
See table below
TJI
110
210
230,
360
560
Top View
March 2014
Min. Web
Stiffener
Size
58" x 2 516"(1)
" x 2 516"(1)
78"
Nailing Requirements
Type
Quantity
8d (0.113" x 2")
x 2 516"(1)
2x4(2)
FlooR deTailS
Load bearingor
braced/shear
wallabove
(must stack
over wall
below)
Blocking panel:
118" TJ Rim Board,
1" TimberStrand LSL,
or TJI joist
116"
B1
B1
W
B2
Top mount
hanger
116"
Face mount
hanger
H1
H3
TJI
Backer block
both sides of
web with single
TJI joist
CS
110
9" or 14"
117 8"
Filler Block(1)
(Detail H2)
2x6
2x8
Cantilever
Filler
(Detail E4)
2x6
4'-0"
long
2x10
6'-0"
long
2x6 + 38"
sheathing
4'-0" long
Depth
Backer Block(1)
(Detail F1
or H2)
210
9" or
117 8"
2x6 + 38"
sheathing
5 8"
or "
14" or
16"
2x8 + 38"
sheathing
230 or 360
9" or
14" or
117 8"
16"
2x6 + "
2x8 + "
sheathing sheathing
560
14" or
117 8"
16"
Two
Two
2x6
2x8
2x10 + 38"
sheathing
6'-0" long
2x6 + "
sheathing
4'-0" long
Not applicable
" or 7 8"
7 8"
2x10 + "
sheathing
6'-0" long
or 1" net
2x6
2x8
(1) If necessary, increase filler and backer block height for face mount hangers and maintain 18" gap at top of joist.
See detail W. Filler and backer block dimensions should accommodate required nailing without splitting. The
suggested minimum length is 24" for filler and 12" for backer blocks.
8d (0.113" x 2"),
8d (0.131" x 2"),
10d (0.128" x 3"),
12d (0.128" x 3")
Equivalent
Nominal
Framing
Width
4"
4"
3"
4"(3)
4"(3)
4"(3)
6"
6"
6"
2"
3"
3"
285
320
320
215
240
240
185(5)
205(5)
240
(1) Stagger nails when using 4" on-center spacing and maintain 38" joist and panel edge distance. One row of fasteners is permitted (two at abutting panel edges) for diaphragms. Fastener spacing
for TJI joists in diaphragm applications cannot be less than shown in table. When fastener spacing for blocking is less than above, rectangular blocking must be used in lieu of TJI joists.
(2) For non-diaphragm applications, multiple rows of fasteners are permitted if the rows are offset at least " and staggered.
(3) Can be reduced to 3" on-center for light gauge steel straps with 10d (0.148" x 1") nails.
(4) The maximum allowable seismic design capacities may be increased by a factor of 1.4 for wind design applications.
(5) The design capacity of an upblocked diaphragm framed with TJI 110, 210 or 230 joists may be multiplied by a factor of 1.18 if a solvent-based subfloor adhesive that meets ASTM D3498
(AFG-01) performance standards is used in combination with mechanical fasteners for sheathing attachment. See page 12 for Weyerhaeuser's adhesive recommendations.
14 gauge staples may be substituted for 8d (0.113" x 2") nails if minimum penetration of 1" is achieved.
Table also applies to the attachment of TJI rim joists and blocking panels to the wall plate.
March 2014
Plate nail
Plate nail
Toe
nail
When sheathing
thickness exceeds
78", trim sheathing
tongue at rim board
Toe nail
6"
Structural exterior
sheathing
Treated
2x_ ledger
Siding
Weather-resistive barrier
Flashing
118" TJ Rim Board or
1" TimberStrand LSL
Washers or prefab spacers to
allow for drainage. Maximum
airspace is ". Add sealant.
6"(2)
(1) Can be reduced to 5" on-center if nail penetration into the narrow edge is no more than 138" (to avoid splitting).
(2) Can be reduced to 4" on-center if nail penetration into the narrow edge is no more than 138" (to avoid splitting).
If more than one row of nails is used, the rows must be offset at least " and staggered.
14 gauge staples may be substituted for 8d (0.113" x 2") nails if minimum penetration of 1" is achieved.
Rim Board
Thickness
Plate nail
118"
1"
A1
W
A2
"
Lag Bolt
480
610
" Through
Bolt
695
725
General Notes
Toe nail
Web stiffeners required
on both sides at A1W ONLY
Rim-to-joist
nail
A1
Blocking panel:
118" TJ Rim Board,
1" TimberStrand LSL,
or TJI joist
Toe nail
Staggered bolts
Treated 2x_ ledger
Structural exterior sheathing
3,400
3,760
Plate
nail
Staggered
bolts
4"
16"(1)
Flashing
LA
Nail Size
Rim Material
A3.4 A3.4
W
12"
min.
1"
TimberStrandLSL
rim board
March 2014
ALLOWABLE HOLES
Minimum distance from Table B
6"
D1
2 x D1
minimum
(applies to all holes
except knockouts)
6"
L1
6"
L2
6"
2 x L2 D2
minimum
6"
Minimum distance from edge of hole to inside face of nearest end support
Depth
9"
117 8"
14"
16"
TJI
110
210
230
110
210
230
360
560
110
210
230
360
560
210
230
360
560
2"
1'-0"
1'-0"
1'-6"
1'-0"
1'-0"
1'-0"
1'-6"
1'-6"
1'-0"
1'-0"
1'-0"
1'-0"
1'-0"
1'-0"
1'-0"
1'-0"
1'-0"
3"
1'-6"
1'-6"
2'-0"
1'-0"
1'-6"
1'-6"
2'-0"
2'-6"
1'-0"
1'-0"
1'-0"
1'-0"
1'-0"
1'-0"
1'-0"
1'-0"
1'-0"
4"
2'-0"
2'-6"
2'-6"
1'-6"
2'-0"
2'-0"
3'-0"
3'-0"
1'-0"
1'-0"
1'-0"
1'-6"
2'-0"
1'-0"
1'-0"
1'-0"
1'-0"
87 8"
5'-6"
6'-0"
6'-6"
7'-0"
8'-0"
3'-0"
3'-6"
4'-0"
5'-6"
6'-6"
2'-6"
3'-0"
4'-6"
5'-0"
11"
13"
5'-6"
6'-0"
7'-0"
8'-0"
9'-0"
3'-6"
4'-0"
6'-6"
7'-6"
6'-0"
7'-0"
9'-0"
10'-0"
2"
1'-0"
1'-0"
1'-0"
1'-0"
1'-0"
1'-0"
1'-6"
2'-6"
1'-0"
1'-0"
1'-0"
1'-0"
1'-6"
1'-0"
1'-0"
1'-0"
1'-0"
3"
1'-6"
2'-0"
2'-0"
1'-6"
1'-6"
2'-0"
2'-6"
3'-6"
1'-0"
1'-0"
1'-0"
1'-6"
3'-0"
1'-0"
1'-0"
1'-0"
2'-0"
4"
2'-6"
2'-6"
3'-0"
2'-0"
2'-6"
2'-6"
3'-6"
4'-6"
1'-6"
2'-0"
2'-0"
2'-6"
4'-0"
1'-0"
1'-0"
1'-6"
3'-0"
5"
3'-6"
4'-0"
4'-6"
2'-6"
3'-0"
3'-6"
4'-6"
5'-6"
2'-0"
2'-6"
3'-0"
4'-0"
5'-0"
2'-0"
2'-0"
3'-0"
4'-6"
6"
4'-6"
5'-0"
5'-0"
4'-6"
5'-0"
5'-6"
6'-6"
7'-0"
3'-6"
4'-0"
4'-0"
6'-0"
7'-0"
3'-0"
3'-6"
5'-0"
6'-6"
7"
87 8"
11"
13"
5'-0"
5'-6"
5'-6"
6'-6"
7'-6"
4'-0"
4'-6"
5'-0"
6'-6"
7'-6"
3'-6"
4'-0"
5'-6"
7'-0"
6'-0"
6'-6"
7'-0"
7'-6"
8'-0"
6'-0"
6'-6"
7'-0"
8'-0"
9'-0"
6'-6"
7'-0"
9'-0"
10'-0"
8'-0"
8'-6"
9'-0"
9'-6"
10'-0"
8'-0"
9'-0"
10'-0"
11'-0"
11'-0"
11'-0"
11'-6"
12'-0"
Minimum distance from edge of hole to inside face of nearest intermediate or cantilever support
Depth
9"
117 8"
14"
16"
TJI
110
210
230
110
210
230
360
560
110
210
230
360
560
210
230
360
560
2"
2'-0"
2'-0"
2'-6"
1'-0"
1'-0"
1'-0"
2'-0"
1'-6"
1'-0"
1'-0"
1'-0"
1'-0"
1'-0"
1'-0"
1'-0"
1'-0"
1'-0"
3"
2'-6"
2'-6"
3'-0"
1'-0"
1'-0"
2'-0"
3'-0"
3'-0"
1'-0"
1'-0"
1'-0"
1'-0"
1'-0"
1'-0"
1'-0"
1'-0"
1'-0"
4"
3'-6"
3'-6"
4'-0"
1'-6"
2'-0"
2'-6"
4'-0"
4'-6"
1'-0"
1'-0"
1'-0"
2'-0"
1'-6"
1'-0"
1'-0"
1'-0"
1'-0"
87 8"
8'-6"
9'-0"
10'-0"
11'-0"
12'-0"
4'-6"
5'-6"
6'-0"
8'-6"
9'-6"
3'-6"
4'-0"
6'-6"
7'-0"
11"
13"
8'-6"
9'-6"
10'-6"
12'-6"
13'-6"
6'-0"
6'-6"
10'-0"
11'-0"
10'-0"
11'-0"
13'-6"
15'-0"
2"
1'-6"
2'-0"
2'-0"
1'-0"
1'-0"
1'-0"
2'-0"
3'-0"
1'-0"
1'-0"
1'-0"
1'-0"
1'-0"
1'-0"
1'-0"
1'-0"
1'-0"
3"
2'-6"
3'-0"
3'-6"
1'-6"
2'-0"
2'-6"
3'-6"
4'-6"
1'-0"
1'-0"
1'-0"
2'-0"
3'-0"
1'-0"
1'-0"
1'-0"
1'-0"
4"
3'-6"
4'-0"
4'-6"
2'-6"
3'-0"
3'-6"
5'-0"
6'-0"
1'-0"
2'-0"
2'-6"
4'-0"
5'-0"
1'-0"
1'-0"
2'-0"
3'-6"
5"
5'-6"
6'-6"
6'-6"
4'-0"
4'-6"
5'-0"
7'-0"
8'-0"
2'-6"
3'-6"
4'-0"
5'-6"
7'-0"
1'-6"
2'-6"
4'-0"
5'-6"
6"
6'-6"
7'-6"
7'-6"
7'-0"
8'-0"
8'-6"
9'-6"
10'-6"
5'-0"
6'-0"
6'-6"
9'-0"
10'-0"
4'-6"
5'-0"
7'-6"
9'-0"
7"
87 8"
11"
13"
7'-0"
8'-0"
9'-0"
9'-6"
11'-0"
6'-0"
7'-0"
7'-6"
10'-0"
11'-0"
5'-6"
6'-0"
8'-6"
10'-0"
9'-6"
10'-0"
10'-6"
11'-0"
12'-0"
9'-0"
10'-0"
11'-0"
12'-0"
13'-6"
10'-0"
10'-6"
13'-0"
14'-6"
12'-0"
13'-0"
13'-6"
14'-0"
15'-0"
12'-6"
13'-6"
14'-6"
16'-0"
16'-0"
16'-6"
17'-0"
18'-0"
DO NOT
cut or notch flange.
General Notes
Holes may be located vertically anywhere within the web. Leave 18"
of web (minimum) at top and bottom of hole.
Knockouts are located in web at approximately 12" on-center; they
do not affect hole placement.
For simple span (5' minimum) uniformly loaded joists meeting
the requirements of this guide, one maximum size round hole may
be located at the center of the joist span provided that no other
holes occur in the joist.
Distances are based on the maximum uniform loads shown in this
guide. For other load conditions or hole configurations, use Forte
software or contact your Weyerhaeuser representative.
March 2014
DO NOT
cut holes in cantilever
reinforcement.
CanTileveRS
Cantilevers Less than 5" (Brick Ledge)
2'-0"
L1
L2
L2
Less than 5"
5"
4"
to 2
E1
1 3
E3
E2
E1
W
1 3
E4
1 3
F1
PB1
E5
E6
E8
E7
th
eng
er l um y)
v
e
til
xim nl
Can 0" ma ads o
4'- orm lo
if
(un
E9
Wood
backer
Nail rim to blocking panel and
blocking panel to plate with
connections equivalent to floor
panel schedule (E7/E8/E9).
Less
than 5"
sc
ime
ev
ntil
th
eng
er l
t
1
Blocking panel between
each joist. Full depth
vertical blocking at
E5 and E6, horizontal
blocking at E7/E8/E9.
5" to 24"
TJI
L1
2'-0"
Apply subfloor
adhesive to all
contact surfaces
Two
8d (0.113" x 2")
nails or 2" screws,
typical
10
March 2014
CanTileveRS
Cantilever Reinforcement
Section A: Cantilevers less than 5" (Brick Ledge)
Depth
TJI
Roof
Truss
Span
35 PSF
16"
9"
117 8"
14"
9"
117 8"
14"
16"
9"
117 8"
14"
16"
117 8"
14"
16"
117 8"
14"
16"
110
210
230
360
560
20'
22'
24'
26'
28'
30'
32'
20'
22'
24'
26'
28'
30'
32'
24'
26'
28'
30'
32'
34'
28'
30'
32'
34'
36'
38'
40'
30'
32'
34'
36'
38'
40'
19.2"
E5
X
E5
E5
E5
E5
E5
55 PSF
19.2"
E5
E5
E5
E5
E5
X
E5
E5
E5
E5
E5
E5
E5
E5
E5
E5
E5
E5
E5
E5
E5
E5
E5
E5
E5
E5
E5
E5
E5
35 PSF
24"
E5
E5
E5
E5
E6
X
X
E5
E5
E5
E5
E5
E6
X
E5
E5
E5
E5
E6
X
E5
E5
E5
E6
E6
E6
E6
E5
E5
E5
E6
E6
E6
16"
E2
19.2"
E2
E2
E3
E2
E2
E2
E3
X
E2
E2
E2
E2
E3
X
General Notes
4. Scan down to find the appropriate cantilever detail and refer to drawing
on page 10:
Blank cells indicate that no reinforcement is required.
E4 may be used in place of E2 or E3 except when using TJI 560 joists.
X indicates that cantilever will not work. Use Forte and Javelin software, or
reduce spacing of joists and recheck table.
E2
E3
E3
E2
E3
X
X
E2
E2
E3
X
X
E2
19.2"
E2
E2
E3
X
X
X
E2
E3
X
X
X
X
24"
X
X
X
X
X
X
X
E2
E3
X
X
X
X
X
X
X
X
X
X
X
E2
E3
E3
E2
E2
E3
X
X
X
E2
E3
X
X
X
X
11
E2
E2
E3
E2
E3
X
X
E2
E3
E3
X
X
X
E2
E3
X
X
X
X
55 PSF
E2
E2
E2
E2
E3
E2
E3
E3
X
E2
March 2014
FiRe-SaFe ConSTRuCTion
The assemblies shown below are provided to help you specify and install Trus Joist brand products with fire safety in mind. For more information on fire assemblies
and fire-safe construction, please refer to the Weyerhaeuser Fire-Rated Assemblies and Sprinkler Systems Guide, 1500, or visit woodbywy.com.
TJI joists with Flak Jacket protection meet 2012 IRC requirements for fire protection of floors and give you an effective one-hour-rated assembly for multi-family
projects. This new solution helps you easily and efficiently meet code without impacting construction procedures or adding complexity to your jobs. TJI joists with
FlakJacket protection are available in limited markets; contact your Weyerhaeuser representative for more information.
Single Layer
Single Layer
Double Layer
Prevent Shrinkage
Construction
adhesive
Avoid Shiners
Movement
Gaps develop as
sheathing shrinks
Shiner
Bend tab
and fasten
For more information and tips on how to prevent floor noise, refer to the Weyerhaeuser
Prevention and Repair of Floor System Squeaks Technical Resource Sheet, 9009,
orcontact your Weyerhaeuser representative.
12
March 2014
RooF FRaMing
WARNING
Joists are unstable until
laterally braced.
See Warning Notes on page 5.
H5
Safety bracing (1x4 minimum) placed
at 8' on-center (6' on-center for TJI
110 joists) and extended to a braced
end wall. Fasten at each joist with two
8d (0.113" x 2") nails minimum.
H5
R10
H6
R7
R5
R5
R3
R1
R10
R1
See
Allowable Holes
on page 9
R8
General Notes
Unless otherwise noted, all details are valid to a maximum slope of 12:12.
Web stiffeners are required if the sides of the hanger do not laterally support at
least 38" of the TJI joist top flange.
Intermediate Bearing
(3" minimum bearing required)
13
March 2014
RooF deTailS
Shear blocking:
118" TJ Rim Board,
1" TimberStrand LSL,
or TJI joist
R1
Variable slope
seat connector
13
R1
W
R3
TJI joist
flange must
bear fully on
plate
R3
W
Two rows
8d (0.113" x 2")
nails at 8" on-center
0" m
4'- imu
n
mi
R7
S
"
2'-0 um
xim
a
m
R8
R7
W
Birdsmouth
cut must not
overhang
inside face
of plate
Birdsmouth Cut
Intermediate Bearing
R7
"
2'-0 um
m
i
x
ma
R5
Web stiffeners
required on both sides
at R7W ONLY
Web stiffeners
required on
both sides at
R3W ONLY
Web stiffeners
required on
both sides at
R1W ONLY
13
Birdsmouth Cut
Birdsmouth Cut
0" m
4'- imu
n
i
m
Two rows
8d (0.113" x 2")
nails at 8" on-center
0" m
4'- imu
n
i
m
Filler
10d (0.128" x 3") nails
at 8" on-center
"
2'-0 um
m
i
x
ma
R9
"
2'-0 um
xim
a
m
R10 R10
W
14
March 2014
RooF deTailS
LSTA18 (Simpson or USP) strap with
twelve 10d (0.148" x 112") nails
Double beveled
bearing plate
when slope
exceeds :12
R14 R14
W
Birdsmouth Cut
Strap nails:
Leave 238"
minimum
end distance
End wall
BC
Backer block: Install tight to bottom
flange (tight to top flange with top mount
hangers). Attach with ten 10d (0.128" x 3")
nails, clinched when possible.
H6 H6S
1 3
1 3
1 3
1 3
1 3
1 3
1 3
1 3
1 3
For TJI joists with slopes of 10 :12 to 12 :12, the vertical depth of the shear blocking at bearing will require 118" TJ Rim Board or 1" TimberStrand LSL that is one size
deeper than the TJI joist. DO NOT use 118" TJ Rim Board in ventilation-hole applications.
110
9" or
14"
117 8"
2x6
5 8"
2x8
210
9" or
117 8"
2x6 + 38"
sheathing
or "
14" or
16"
2x8 + 38"
sheathing
230 or 360
9" or
14" or
117 8"
16"
2x6 + 12"
2x8 + 12"
sheathing
sheathing
" or 7 8"
7 8"
or 1" net
560
Two
2x6
14" or
16"
Two
2x8
2x6
2x8
117 8"
Horizontal length = L
If necessary, increase filler and backer block height for face mount hangers and maintain 18" gap at top of joist; see detailW
on page 6. Filler and backer block dimensions should accommodate required nailing without splitting. The suggested
minimum length is 24" for filler and 12" for backer blocks.
2:12
2"
2"
3"
33 8"
3:12
23 8 "
3"
3"
4"
3:12
278"
3"
418"
4"
4:12
314"
4"
4"
53 8"
4:12
358"
4"
5"
6"
5:12
4"
5"
578"
6"
Slope
6:12
4"
6"
7"
8"
Add D factor
to obtain proper
cut length
tor
fac h
ngt
s
L x Cut le
e
lop
8:12
63 8"
8"
93 8 "
10"
9:12
718"
9"
10"
12"
10:12
8"
10"
11"
1338"
11:12
8"
11"
1278"
14"
12:12
9"
1178"
14"
16"
15
March 2014
Depth
9"
117 8"
16"
14"
16"
9"
117 8"
19.2"
14"
16"
9"
117 8"
24"
14"
16"
TJI
110
210
230
110
210
230
360
560
110
210
230
360
560
210
230
360
560
110
210
230
110
210
230
360
560
110
210
230
360
560
210
230
360
560
110
210
230
110
210
230
360
560
110
210
230
360
560
210
230
360
560
Non-Snow (125%)
20LL + 15DL
20LL + 20DL
Low
High
Low
High
20'-0"
17'-10"
19'-1"
16'-11"
21'-2"
18'-10"
20'-2"
17'-10"
21'-11"
19'-6"
20'-10"
18'-6"
23'-11"
21'-4"
22'-9"
20'-2"
25'-3"
22'-6"
24'-1"
21'-4"
26'-1"
23'-3"
24'-10"
22'-0"
27'-9"
24'-9"
26'-5"
23'-5"
31'-11"
28'-6"
30'-5"
27'- 0"
27'-2"
24'-3"
25'-7"
23'-0"
28'-9"
25'-7"
27'-4"
24'-3"
29'-8"
26'-6"
28'-3"
25'-1"
31'-6"
28'-2"
30'-0"
26'-8"
36'-3"
32'-4"
34'-6"
30'-7"
31'-10"
28'-5"
30'-0"
26'-11"
32'-10"
29'-4"
31'-4"
27'-9"
34'-11"
31'-2"
33'-3"
29'-6"
40'-1"
35'-9"
38'-2"
33'-11"
18'-9"
16'-9"
17'-11"
15'-10"
19'-10"
17'-9"
18'-11"
16'-9"
20'-7"
18'-4"
19'-7"
17'-4"
22'-5"
20'-0"
21'-5"
19'-0"
23'-9"
21'-2"
22'-7"
20'-0"
24'-6"
21'-10"
23'-4"
20'-8"
26'-1"
23'-3"
24'-10"
22'-0"
30'- 0"
26'-9"
28'-7"
25'-4"
25'-1"
22'-10"
23'-4"
21'-7"
27'-0"
24'-1"
25'-7"
22'-10"
27'-10"
24'-10"
26'-6"
23'-7"
29'-7"
26'-5"
28'-2"
25'-0"
34'-0"
30'-4"
32'-5"
28'-9"
29'-5"
26'-8"
27'-5"
25'-4"
30'-11"
27'-7"
28'-11"
26'-1"
32'-10"
29'-3"
31'-3"
27'-9"
37'-8"
33'-7"
35'-10"
31'-10"
17'-5"
15'-6"
16'-7"
14'-8"
18'-5"
16'-5"
17'-6"
15'-6"
19'-0"
17'-0"
18'-1"
16'-1"
20'-7"
18'-7"
19'-2"
17'-7"
21'-11"
19'-7"
20'-11"
18'-7"
22'-8"
20'-3"
21'-7"
19'-2"
24'-1"
21'-6"
23'- 0"
20'-5"
27'-9"
24'-9"
26'-5"
23'-6"
22'-5"
21'-1"
20'-10"
19'-6"
24'-7"
22'-4"
22'-11"
21'-1"
25'-9"
23'-0"
24'-1"
21'-10"
27'-5"
24'-6"
26'-1"
23'-2"
31'-6"
28'-1"
30'-0"
26'-8"
26'-3"
24'-9"
24'-6"
22'-11"
27'-9"
25'-6"
25'-10"
24'-2"
30'-4"
27'-1"
28'-11"
25'-8"
34'-10"
31'-2"
33'-2"
29'-6"
General Notes
1. Determine appropriate live and dead load, and the load duration factor.
2. If your slope is 6:12 or less, use the Low slope column. If it is between 6:12
and 12:12, use the High column.
3. Scan down the column until you find a span that meets or exceeds the span
of your application.
16
50LL + 15DL
Low
High
15'-11"
14'-9"
17'-2"
15'-7"
17'-9"
16'-2"
17'-11"
17'-4"
19'-8"
18'-8"
20'-9"
19'-3"
22'-7"
20'-6"
26'- 0"
23'-7"
19'-6"
18'-11"
21'-5"
20'-9"
22'-7"
21'-10"
25'-8"
23'-4"
29'-6"
26'-9"
22'-8"
22'-2"
24'-2"
23'-5"
26'- 0"
25'-10"
31'-8"
29'-8"
14'-6"
13'-10"
15'-11"
14'-8"
16'-8"
15'-2"
16'-4"
15'-10"
17'-11"
17'-4"
18'-11"
18'-1"
21'-2"
19'-3"
24'-4"
22'-2"
17'-0"
17'-3"
18'-10"
18'-11"
20'-7"
19'-11"
21'-7"
21'-8"
26'-5"
25'-2"
18'-10"
20'-2"
21'-2"
21'-3"
21'-7"
21'-8"
26'-5"
25'-5"
13'-0"
12'-7"
14'-3"
13'-7"
15'-0"
14'-0"
13'-7"
14'-2"
15'-0"
15'-6"
16'-11"
16'-4"
17'-3"
17'-4"
21'-1"
20'-3"
13'-7"
14'-7"
15'-0"
16'-1"
16'-11"
17'-0"
17'-3"
17'-4"
21'-1"
20'-3"
15'-0"
16'-1"
16'-11"
17'-0"
17'-3"
17'-4"
21'-1"
20'-3"
March 2014
9"
117 8"
14"
16"
TJI
110
210
230
110
210
230
360
560
110
210
230
360
560
210
230
360
560
6'
Total Load
Snow
115%
289
321
360
289
321
360
368
449
289
321
360
368
449
321
360
368
449
NonSnow
125%
314
349
392
314
349
392
400
488
314
349
392
400
488
349
392
400
488
Defl.
Live
Load
L/240
*
*
*
*
*
*
*
*
*
*
*
*
*
*
*
*
*
8'
Total Load
Snow
115%
218
242
272
218
242
272
277
338
218
242
272
277
338
242
272
277
338
NonSnow
125%
237
263
295
237
263
295
301
368
237
263
295
301
368
263
295
301
368
Defl.
Live
Load
L/240
*
*
*
*
*
*
*
*
*
*
*
*
*
*
*
*
*
Live
Load
L/240
*
*
*
*
*
*
*
*
*
*
*
*
*
*
*
*
*
Defl.
Snow
115%
175
194
218
175
194
218
223
272
175
194
218
223
272
194
218
223
272
NonSnow
125%
190
211
237
190
211
237
242
295
190
211
237
242
295
211
237
242
295
Live
Load
L/240
*
*
*
*
*
*
*
*
*
*
*
*
*
*
*
*
*
Defl.
Snow
115%
146
162
182
146
162
182
186
227
146
162
182
186
227
162
182
186
227
14'
Total Load
Snow
115%
114
137
153
125
139
156
159
195
125
139
156
159
195
139
156
159
195
NonSnow
125%
124
149
166
136
151
170
173
212
136
151
170
173
212
151
170
173
212
Defl.
Live
Load
L/240
112
130
143
*
*
*
*
*
*
*
*
*
*
*
*
*
*
16'
Total Load
Snow
115%
88
105
117
110
122
137
140
170
110
122
137
140
170
122
137
140
170
NonSnow
125%
95
115
127
119
132
149
152
185
119
132
149
152
185
132
149
152
185
Defl.
Live
Load
L /240
77
90
99
*
*
*
*
*
*
*
*
*
*
*
*
*
*
9"
117 8"
14"
16"
TJI
110
210
230
110
210
230
360
560
110
210
230
360
560
210
230
360
560
18'
Total Load
Defl.
Snow
115%
NonSnow
125%
Live
Load
L/240
83
93
88
106
117
124
152
98
108
122
124
152
108
122
124
152
86
94
95
115
128
135
165
106
118
132
135
165
118
132
135
165
64
71
91
106
116
*
*
*
*
*
*
*
*
*
*
*
20'
Total Load
Defl.
Snow
115%
NonSnow
125%
Live
Load
L/240
86
95
112
137
84
97
110
112
137
97
110
112
137
77
93
103
122
148
92
106
119
122
148
106
119
122
148
68
79
86
103
*
*
*
*
*
*
*
*
*
*
6:12
1.118
NonSnow
125%
Live
Load
L/240
84
93
102
124
89
100
102
124
77
85
105
135
76
91
101
111
135
96
108
111
135
60
66
78
117
75
87
95
*
*
*
*
*
*
7:12
1.158
8:12
1.202
9:12
1.250
Snow
115%
79
102
124
Snow
115%
NonSnow
125%
Live
Load
L/240
82
114
82
122
61
91
78
93
114
81
90
93
114
77
85
101
124
88
97
101
124
68
74
88
*
*
*
*
*
26'
Total Load
Defl.
Snow
115%
NonSnow
125%
Live
Load
L/240
97
97
86
105
94
114
75
83
94
114
76
86
105
28'
Total Load
Defl.
Snow
115%
NonSnow
125%
Live
Load
L /240
73
79
79
59
70
104
73
79
*
*
76
98
76
106
57
85
80
98
87
106
76
*
Slope Factors
Slope
Factor
10:12
1.302
11:12
1.357
12:12
1.414
General Notes
2. Select appropriate Roof Joist Horizontal Clear Span. For slopes greater than
2:12, approximate the increased dead load by multiplying the joist horizontal clear
span by the Slope Factor above.
3. Scan down the column to find a TJI joist that meets or exceeds actual total load.
17
March 2014
Joist
Depth
9"
117 8"
14"
16"
TJI
Hanger
110
210
230
110
210
230
360
560
110
210
230
360
560
210
230
360
560
ITS1.81/9.5
ITS2.06/9.5
ITS2.37/9.5
ITS1.81/11.88
ITS2.06/11.88
ITS2.37/11.88
ITS2.37/11.88
ITS3.56/11.88(6)
ITS1.81/14
ITS2.06/14
ITS2.37/14
ITS2.37/14
ITS3.56/14(6)
ITS2.06/16
ITS2.37/16
ITS2.37/16
ITS3.56/16(6)
Nailing
Capacity
(lbs)
Header
Joist
975
10d
N.A.
1,070
10d
N.A.
1,120
10d
N.A.
975
10d
N.A.
1,070
10d
N.A.
1,120
10d
N.A.
1,140
10d
N.A.
1,150
10d
N.A.
975
10d
N.A.
1,070
10d
N.A.
1,120
10d
N.A.
1,140
10d
N.A.
1,150
10d
N.A.
1,070
10d
N.A.
1,120
10d
N.A.
1,140
10d
N.A.
1,150
10d
N.A.
Hanger
IUS1.81/9.5
IUS2.06/9.5
IUS2.37/9.5
IUS1.81/11.88(1)
IUS2.06/11.88(1)
IUS2.37/11.88(1)
IUS2.37/11.88(1)
IUS3.56/11.88(1)(6)
IUS1.81/14(1)
IUS2.06/14(1)
IUS2.37/14(1)
IUS2.37/14(1)
IUS3.56/14(1)(6)
IUS2.06/16 (1)
IUS2.37/16 (1)
IUS2.37/16 (1)
IUS3.56/16(1)(6)
Nailing
Capacity
(lbs)
Header
Joist
950
10d
N.A.
950
10d
N.A.
950
10d
N.A.
975
10d
N.A.
1,070
10d
N.A.
1,120
10d
N.A.
1,140
10d
N.A.
1,150
10d
N.A.
975
10d
N.A.
1,070
10d
N.A.
1,120
10d
N.A.
1,140
10d
N.A.
1,150
10d
N.A.
1,070
10d
N.A.
1,120
10d
N.A.
1,140
10d
N.A.
1,150
10d
N.A.
9"
117 8"
14"
16"
TJI
110
210
230
110
210
230
360
560
110
210
230
360
560
210
230
360
560
SUR/L1.81/9
SUR/L2.1/9
SUR/L2.37/9
SUR/L1.81/11
SUR/L2.1/11
SUR/L2.37/11
SUR/L2.37/11
SUR/L410
SUR/L1.81/14
SUR/L2.1/11
SUR/L2.37/14
SUR/L2.37/14
SUR/L414
SUR/L2.1/11
SUR/L2.37/14
SUR/L2.37/14
SUR/L414
Nailing
Capacity
(lbs)
Header
Joist
1,220
16d
10d x 1"
1,330
16d
10d x 1"
1,330
16d
10d x 1"
1,240
16d
10d x 1"
1,380
16d
10d x 1"
1,410
16d
10d x 1"
1,430
16d
10d x 1"
1,495
16d
16d
1,240
16d
10d x 1"
1,380
16d
10d x 1"
1,410
16d
10d x 1"
1,430
16d
10d x 1"
1,460
16d
16d
1,380
16d
10d x 1"
1,410
16d
10d x 1"
1,430
16d
10d x 1"
1,460
16d
16d
Variable Slope Seat Connector (2)
Joist
Depth
Hanger
Nailing
Capacity
(lbs)
Header
Joist
MIT49.5
2,115
16d
10d x 1"
MIT4.28/9.5
2,115
16d
10d x 1"
MIT359.5-2
2,115
16d
10d x 1"
MIT411.88
2,115
16d
10d x 1"
MIT4.28/11.88 2,115
16d
10d x 1"
MIT3511.88-2
2,115
16d
10d x 1"
MIT3511.88-2
2,115
16d
10d x 1"
B7.12/11.88
2,925
16d
16d
MIT414
2,115
16d
10d x 1"
MIT4.28/14
2,115
16d
10d x 1"
MIT3514-2
2,115
16d
10d x 1"
MIT3514-2
2,115
16d
10d x 1"
B7.12/14
2,925
16d
16d
LBV4.28/16
2,395
16d
10d x 1"
LBV4.75/16
2,115
16d
10d x 1"
LBV4.75/16
2,115
16d
10d x 1"
B7.12/16
2,925
16d
16d
Hanger
Hanger
MIU3.56/9(1)
MIU4.28/9
MIU4.75/9
MIU3.56/11(1)
MIU4.28/11(1)
MIU4.75/11(1)
MIU4.75/11
HU412-2
MIU3.56/14(1)
MIU4.28/14(1)
MIU4.75/14(1)
MIU4.75/14(1)
HU414-2
MIU4.28/16(1)
MIU4.75/16(1)
MIU4.75/16(1)
HU414-2
Nailing
Capacity
(lbs)
Header
Joist
2,215
16d
10d x 1"
2,305
16d
10d x 1"
2,305
16d
10d x 112"
2,215
16d
10d x 1"
2,395
16d
10d x 1"
2,490
16d
10d x 1"
2,525
16d
10d x 1"
2,380
16d
16d
2,215
16d
10d x 1"
2,395
16d
10d x 1"
2,490
16d
10d x 1"
2,525
16d
10d x 1"
2,925
16d
16d
2,395
16d
10d x 1"
2,490
16d
10d x 1"
2,525
16d
10d x 1"
2,925
16d
16d
Nailing
Hanger Capacity
(lbs)
Header
Joist
VPA25
975
10d
10d x 1"
VPA2.1
1,070
10d
10d x 1"
VPA35
1,120
10d
10d x 1"
VPA35
1,140
10d
10d x 1"
VPA4
1,230
10d
10d x 1"
TJI
110
210
230
360
560
General Notes
Joist
Capacities will vary with different nailing criteria or other support conditions; contact your
Weyerhaeuser representative for assistance.
TJI
Hanger
110
210
230
360
560
LSSUI25
LSSU2.1
LSSUI35
LSSUI35
LSSU410
Capacity (lbs)
Nailing
Sloped
Sloped and Header
Joist
Only
Skewed
(1)
1,110
995
10d
10d x 1"
1,110(1)
995
10d
10d x 1"
1,110(1)
995
10d
10d x 1"
1,110(1)
995
10d
10d x 1"
1,725(1)
1,625
16d
10d x 1"
Hanger capacities shown are either joist bearing capacity or hanger capacitywhichever
is less. Joist end reaction must be checked to ensure it does not exceed the capacity shown
in the tables.
Use sloped seat hangers and beveled web stiffeners when TJI joist slope exceeds :12.
Leave 116" clearance (18" maximum) between the end of the supported joist and the header or
hanger.
Nails: 16d = 0.162" x 3", 10d = 0.148" x 3", and 10d x 1" = 0.148" x 1".
18
March 2014
Joist
Depth
9"
117 8"
14"
16"
TJI
Hanger
110
210
230
110
210
230
360
560
110
210
230
360
560
210
230
360
560
THO17950
TFL2095
TFL2395
THO17118
TFL20118
TFL23118
TFL23118
THO35118
TFL1714
TFL2014
TFL2314
TFL2314
THO35140
TFL2016
TFL2316
TFL2316
THO35160
Nailing
Capacity
(lbs)
Header
Joist
975
10d
10d x 1"
1,070
10d
10d x 1"
1,120
10d
10d x 1"
975
10d
10d x 1"
1,070
10d
10d x 1"
1,120
10d
10d x 112"
1,140
10d
10d x 1"
1,430
10d
10d x 1"
975
10d
10d x 1"
1,070
10d
10d x 1"
1,120
10d
10d x 1"
1,140
10d
10d x 1"
1,430
10d
10d x 1"
1,070
10d
10d x 1"
1,120
10d
10d x 1"
1,140
10d
10d x 1"
1,430
10d
10d x 1"
Hanger
THF17925
THF20925
THF23925
THF17112
THF20112
THF23118
THF23118
THF35112
THF17140
THF20140
THF23140
THF23140
THF35140
THF20157
THF23160
THF23160
THF35157
Nailing
Capacity
(lbs)
Header
Joist
910
10d
10d x 1"
910
10d
10d x 1"
1,245
10d
10d x 1"
910
10d
10d x 1"
910
10d
10d x 1"
1,245
10d
10d x 112"
1,265
10d
10d x 1"
1,460
10d
10d x 1"
975
10d
10d x 1"
1,070
10d
10d x 1"
1,245
10d
10d x 1"
1,265
10d
10d x 1"
1,460
10d
10d x 1"
1,425
10d
10d x 1"
1,245
10d
10d x 1"
1,265
10d
10d x 1"
1,460
10d
10d x 1"
Hanger
SKH1720L /R
SKH2020L /R
SKH2320L /R
SKH1720L /R
SKH2020L /R
SKH2320L /R
SKH2320L /R
SKH410L /R (4)
SKH1720L /R
SKH2020L /R
SKH2324L /R
SKH2324L /R
SKH414L /R (4)
SKH2024L /R
SKH2324L /R
SKH2324L /R
SKH414L /R (4)
Joist
Depth
9"
117 8"
14"
16"
TJI
Hanger
110
210
230
110
210
230
360
560
110
210
230
360
560
210
230
360
560
THO35950
THO20950-2
THO23950-2
THO35118
THO20118-2
THO23118-2
THO23118-2
BPH71118
THO35140
THO20140-2
THO23140-2
THO23140-2
BPH7114
THO20160-2
THO23160-2
THO23160-2
BPH7116
Nailing
Capacity
(lbs)
Header
Joist
2,050
10d
10d x 1"
2,330
16d
10d
2,660
16d
10d
2,050
10d
10d x 1"
2,330
16d
10d
2,730
16d
10d
2,770
16d
10d
3,185
16d
10d
2,150
10d
10d x 1"
2,330
16d
10d
2,730
16d
10d
2,770
16d
10d
3,185
16d
10d
2,330
16d
10d
2,730
16d
10d
2,770
16d
10d
3,185
16d
10d
Hanger
THF35925
THF20925-2
THF23925-2
THF35112
THF20112-2
THF23118-2
THF23118-2
HD7120
THF35140
THF20140-2
THF23140-2
THF23140-2
HD7140
THF20140-2
THF23160-2
THF23160-2
HD7140
Nailing
Capacity
(lbs)
Header
Joist
1,370
10d
10d x 1"
1,390
10d
10d
1,625
10d
10d
1,825
10d
10d x 1"
1,855
10d
10d
1,855
10d
10d
1,855
10d
10d
2,255
16d
10d
2,215
10d
10d x 1"
2,320
10d
10d
2,490
10d
10d
2,525
10d
10d
2,820
16d
10d
2,320
10d
10d
2,490
10d
10d
2,525
10d
10d
2,820
16d
10d
TJI
110
210
230
360
560
Support Requirements
Nailing
Capacity
(lbs)
Header
Joist
945
10d
10d x 1"
1,035
10d
10d x 1"
1,090
10d
10d x 1"
945
10d
10d x 1"
1,035
10d
10d x 1"
1,090
10d
10d x 112"
1,110
10d
10d x 1"
1,460
10d
16d
945
10d
10d x 1"
1,035
10d
10d x 1"
1,090
10d
10d x 1"
1,110
10d
10d x 1"
1,460
10d
16d
1,035
10d
10d x 1"
1,090
10d
10d x 1"
1,110
10d
10d x 1"
1,460
10d
16d
Nailing
Hanger Capacity
(lbs)
Header
Joist
TMP175
1,150
10d
10d x 1"
TMPH175 1,220
10d
10d x 1"
TMP21
1,290
10d
10d x 1"
TMPH21
1,330
10d
10d x 1"
TMP23
1,330
10d
10d x 1"
TMPH23
1,330
10d
10d x 1"
TMP23
1,505
10d
10d x 1"
TMPH23
1,505
10d
10d x 1"
TMP4
1,725
10d
10d x 1"
TMPH4
1,725
10d
10d x 1"
Joist
Minimum support width for single- and double-joist top mount hangers is 3" (1" for ITS hangers).
Minimum support width for face mount hangers with 10d and 16d nails (clinched) is 1" and 1",
respectively.
Footnotes:
(1) Face mount hanger capacities may be increased up to 15% for snow roofs or 25% for non-snow roofs. Maximum
increase for LSSU, LSSUI, and LSSH hangers is 15%.
(2) VPA connectors are allowed on slopes of 3:12 through 12:12 only.
(3) LSSU, LSSUI, and LSSH hangers can be field adjusted for slopes and skews of up to 45 degrees. Additional lateral
restraints are required for 16" deep TJI joists.
(4) Miter cut is required at end of joist.
(5) TMP connectors are allowed on slopes of 1:12 through 6:12 only, and TMPH connectors are allowed on slopes of
6:12 through 12:12 only.
(6) Capacity may be increased to 1,330 lbs if web stiffeners are used.
TJI
Hanger
110
210
230
360
560
LSSH179
LSSH20
LSSH23
LSSH23
LSSH35
19
March 2014
Capacity (lbs)
Nailing
Sloped Sloped and Header
Joist
Only
Skewed
1,180
1,180
10d
10d x 1"
1,180
1,180
10d
10d x 1"
1,180
1,180
10d
10d x 1"
1,180
1,180
10d
10d x 1"
1,595(1)
1,595
16d
10d x 1"
ConTaCT uS
1.888.453.8358 woodbywy.com/contact
Contact your local representative or dealer at:
, Weyerhaeuser, Flak Jacket, Forte, Javelin, Microllam, Parallam, TimberStrand, TJ, TJI,
and Trus Joist are registered trademarks and Edge Gold, and TJ-Pro are trademarks of
Weyerhaeuser NR. 2014 Weyerhaeuser NR Company. All rights reserved. Printed in the USA.