You are on page 1of 1

Steam Turbine

Operation

Technical Data
Limit Curves

Permissible temperature difference in the wall of HP stop and control valve casing during Sliding
Pressure Operation Mode
140
= f(m )

120
Heating up

100
F
80
N

60

40

[K]

OPERATION MODE
F=Fast
N=Normal
S=Slow

20
0
-20
-40

Cooling down

-60
-80
0

100

200

300

400

500

600
m [C]

= (i - m) on the wall temperature sensor

= temperature of inner layer

m = temperature of middle layer

BHEL, Hardwar

6.1-0110-01