Professional Documents
Culture Documents
Zte Lte FDD Handover Feature
Zte Lte FDD Handover Feature
Handover
Feature Description
Version
Date
Author
Approved By
Remarks
V1.0
2011-02-15
Cheng Hao
V2.0
2011-08-15
Cheng Hao
V2.1
2011-09-01
Cheng Hao
V2.2
2011-9-21
Cheng Hao
TABLE OF CONTENTS
1
Introduction ................................................................................................................ 1
2
2.1
2.2
2.3
2.4
2.5
2.6
2.7
2.8
3
3.1
3.1.1
3.1.2
3.1.3
3.1.4
3.1.5
3.1.6
3.2
3.2.1
3.3
3.3.1
3.3.2
3.4
3.4.1
3.4.2
3.5
3.5.1
3.5.2
3.6
3.6.1
3.6.2
3.7
3.7.1
4
4.1
4.1.1
4.1.2
Glossary .................................................................................................................... 36
FIGURES
Figure 1
Figure 2
II
Introduction
This document describes the connection mode management functions within the
eNodeB in LTE network.
Abbreviations used in this document are explained in Glossary.
Function Description
In LTE system, RRC-connection mobility management is realized by cell handover
strategy for the reason of UE mobility; the load balancing can adjust the traffic
distribution among the cells to reduce the traffic of high-load cell. During the handover,
the service continuity should be guaranteed and the service Qos should be satisfied.
Based on the different characteristics of cell frequency and access technologies before
and after the handover, the cell handover strategy can be divided into intra-frequency
handover, inter-frequency handover and inter-RAT handover.
This document mainly introduces the ZTE eNodeB mobility management in RRC
connection state by adopting cell handover strategy.
Based on the different characteristics of cell frequency before and after the handover,
the cell handover strategy can be divided into:
1
Redirection strategy
Handover to UTRAN
Handover to GERAN
CS fallback to GERAN/UTRAN
Handover strategy includes measurement control and event report. Handover include
measurement, handover decision and handover execution. Measurement is the
prerequisite for handover, and handover decision is the core and the handover
execution is the procedure realizing the handover.
2.1
Intra-Freq handover means the UE in connected state performs handover between the
neighbor cells with the same frequency in E-UTRAN. Intra-Freq handover algorithm is
based on the measurement including Intra-Freq measurement control and Intra-Freq
measurement report handling. Intra-Freq measurement control involves the
establishment, modification, and release of Intra-Freq measurement. For related details,
please refer to Section 3.1.1. The Intra-Freq measurement report handling means that
when eNB receives the Intra-Freq measurement report from UE, the eNB performs IntraFreq handover judgment according to the specific measurement report and other related
information. byReportQuan controls the Intra-Freq measurement quantity that triggers
the report. For related details, please refer to Section 3.2.
2.2
2.3
2.4
Redirection Strategy
The system use redirectedCarrierInfo in the Message RRCConnectionRelease to
indicate UE to camp on the specified system/frequency when disconnected. LTE
supports Intra-Rat redirection and Inter-Rat redirection. This algorithm in this documents
mainly describes redirection from LTE to 3GPP 2G/3G, CDMA2000-HRPD and
CDMA2000-1xRTT.
The UE wireless ability is optional for handover to some target system/neighbor cell. As
long as UE supports the target system/frequency, it can support redirection to target
system/frequency. Therefore, in this mobility management algorithm based on coverage,
if the Intra-Freq measurement report from CEU (Cell Edge UE) shows that the signal
quality of the serving cell is deteriorating, and if the UE wireless ability or network dont
2
2.5
2.6
Handover to UTRAN
LTE is all IP system, and all services are based on IP bearer. When UE handovers to
UTRAN PS domain, the handover is called PS handover to UTRAN. And if UE
handovers to UTRAN CS domain, for example, LTE VoIP is handover to UTRAN CS,
this handover is called SRVCC handover to UTRAN. PS HO needs target UTRAN cell
support and OMC configuration field byUTRANNBRcellPSHOFlg. SRVCC handover,
depends on whether the UE supports the voice service and whether the target cell
supports VoIP, and whether UE and MME support SRVCC. For more details, please
refer to Section 3.5.2.
2.7
Handover to GERAN
GERAN is different from UTRAN. Its special attribute DTM (Dual Transfer Mode)
indicates whether GERAN supports PS and CS simultaneously. Because some GERAN
supports CS only (OMC field byDtmsupport can configure the DTM capability of target
GERAN neighboring cell), the LTE handover to GERAN can be DTM HO ( PS and CS
handover at the same time) or CS HO only.
LTE voice handover to GERAN PS domain is PS HO and the prerequisite is the GERAN
cell supports VoIP ( OMC field ucGERANNBRcellVoIPFlg is configured). The data PS
service, PS HO is performed to GERAN (OMC field byDtmsupport indirectly reflects the
PS HO capability of target GERAN); LTE voice service can be handover to GERAN CS
domain, that is, SRVCC handover to GERAN. When the UE with voice and data
services is handover to GERAN, the data service is handover to PS domain and the
voice service is switched by SRVCC, that is, DTM HO. Handover to GERAN has another
CCO process. During CCO process, the air interface command can carry the SIB
information of the target cell to reduce the access latency. Currently, SRVCC is not
supported. For more details, please refer to Section 3.5.1.
2.8
CS Fallback to GERAN/UTRAN
At the initial stage of LTE network deployment, if the operator has not IMS for its core
network, LTE system can not provide voice service. The voice service can be supported
by CS Fallback to the same coverage cells or overlapped inter-RAT neighboring cells.
That is, when initiating a voice service, the service is handover to the target
GERAN/UTRAN cell and the voice service is provided by the CS domain resources of
GERAN/UTRAN. More specifically, if eNodeB receives INITIAL CONTEXT SETUP
REQUEST or UE CONTEXT MODIFICATION REQUEST with CS Fallback Indicator
from MME at S1 interface, UE shall be triggered to switch to GERAN/UTRAN cell to
perform voice service by means of PS HO, CCO or redirection. Before the handover, the
target cell is selected based on measurement or blind measurement. The present
version supports CS Fallback based on blind measurement, so the target cell can only
be the same coverage cells or the overlapped GERAN/UTRAN cells.
Technical Description
3.1
Measurement in RRC_Connected
When UE is in RRC_connected state, the measurement reporting criterion, on which the
UE bases to send a measurement report, consists of periodical reporting and single
event triggered. Periodical reporting means that the UE regularly reports the measured
quality of DL cell reference signals to eNodeB. Eventtriggered reporting means that the
UE shall judge whether the measured quality of DL cell reference signal meets the
reporting criterion. If yes, the UE shall report the event (including the information such as
Event ID, target cell and so on).
3.1.1
3.1.1.1
Event A1
Event A1 means serving cell quality becomes better than threshold. When receiving
Event A1, eNB shall stop the Inter-Freq measurement the UE is conducting. If the
measurement gap is activated, the measurement gap should be deactivated.
The UE shall:
Apply inequality A1-1, as the entering condition for this event
Apply inequality A1-2, as the leaving condition for this event
Inequality A1-1 (Entering condition)
3.1.1.2
Event A2
Event A2 means the signal quality of the serving cell becomes worse than a predefined
threshold. When receiving Event A2, eNB shall start UE Inter-Freq measurement or start
UE inter-Rat measurement. If the measurement gap needs to be activated, eNB
activates the measurement gap.
The UE shall:
Apply inequality A2-1, as the entering condition for this event
Apply inequality A2-2, as the leaving condition for this event
3.1.1.3
Event A3
Event A3 means neighboring cell quality becomes a predefined offset better than
serving cell. When receiving Event A3, eNB shall start the coverage-based Intra-Freq or
Inter-Freq handover decision.
The UE shall:
Apply inequality A3-1, as the entering condition for this event
Apply inequality A3-2, as the leaving condition for this event
3.1.1.4
Event A4
Event A4 means neighboring becomes better than a predefined threshold. When
receiving Event A4, eNB may trigger handover driven by load balancing.
The UE shall:
Apply inequality A4-1, as the entering condition for this event
Apply inequality A4-2, as the leaving condition for this event
Inequality A4-1 (Entering condition)
3.1.1.5
Event A5
Event A5 means serving cell becomes worse than threshold 1 and neighboring cell
becomes better than threshold 2. When receiving Event A5, eNB may trigger coverage
based Intra-Freq or Inter-Freq handover.
The UE shall:
Apply inequality A5-1 and equation A5-2, both have to be fulfilled, as the entering
condition for this event
Apply inequality A5-3 and equation A5-4, at least one of the two has to be fulfilled, as
the leaving condition for this event
Inequality A5-1 (Entering condition 1)
The configuration of Hys is similar to Hys in Event A1 and Event A2 in terms of its
influence on Event triggering. If Thresh1is set too high and Thresh2 is set too low, the
probability of Event A5 reporting will be increased. Otherwise, if Thresh1 is set too low
and Thresh2 is set too high, the probability of Event A5 reporting will be decreased.
Event A5 supports event-triggered periodical reporting. That is, when UE detects that
the signal quality falls in the reporting range of Event A5, the UE shall begin to report
Event A5 periodically (Its corresponding OMC parameter is byRptIntvl) until the reporting
criteria is not fulfilled any longer or the allowed maximal number of reporting times has
been reached (Its corresponding OMC parameter is byRptAmt).
3.1.1.6
Time-To-Trigger Mechanism
To avoid the event misreport due to the radio quality fluctuation, the event shall be
reported only when the signal quality of the cell to be evaluated meets the report range
or threshold and the reporting condition must be met for a certain time period. The timeto-trigger mechanism is applied to intra- and Inter-Freq measurement (Its corresponding
OMC parameter is byTrigTime). Take Event A1 as an example, UE can only report
Event A1 when serving cell meets the reporting condition and the cell quality meets the
reporting condition for the time period byTrigTime.
3.1.2
3.1.2.1
Event B1
Event B1 means inter RAT neighbor becomes better than threshold. When receiving
Event B1, eNB may trigger coverage based inter RAT handover.
The UE shall:
Apply inequality B1-1, as the entering condition for this event
Apply inequality B1-2, as the leaving condition for this event
Inequality B1-1 (Entering condition)
Mn + Ofn Hys > Thresh
10
Hys is the hysteresis parameter for this event (i.e. hysteresis as defined within
reportConfigInterRAT for this event).
Thresh is the threshold parameter for this event (i.e. b1-Threshold as defined within
reportConfigInterRAT for this event). For CDMA2000, b1-Threshold is divided by -2. Its
corresponding OMC parameter is byRscpSysNbrTrd or byEcNoSysNbrTrd for UTRAN,
byRatSysNbrTrd for GERAN
Mn is expressed in dBm or in dB, depending on the measurement quantity of the interRAT neighbour cell.
Ofn, Hys are expressed in dB.
Thresh is expressed in the same unit as Mn.
3.1.2.2
Event B2
Event B2 means serving becomes worse than threshold1 and inter RAT neighbor
becomes better than threshold2. When receiving Event B2, eNB may trigger coverage
based inter RAT handover.
The UE shall:
Apply inequality B2-1 and equation B2-2, both have to be fulfilled, as the entering
condition for this event
Apply inequality B2-3 and equation B2-4, at least one of the two has to be fulfilled, as
the leaving condition for this event
Inequality B2-1 (Entering condition 1)
Ms + Hys < Thresh1
11
Ofn is the frequency specific offset of the frequency of the inter-RAT neighbor cell (i.e.
offsetFreq as defined within the measObject corresponding to the frequency of the interRAT neighbor cell).
Hys is the hysteresis parameter for this event (i.e. hysteresis as defined within
reportConfigInterRAT for this event).
Thresh1 is the threshold parameter for this event (i.e. b2-Threshold1 as defined within
reportConfigInterRAT for this event).
Thresh2 is the threshold parameter for this event (i.e. b2-Threshold2 as defined within
reportConfigInterRAT for this event). For CDMA2000, b2-Threshold2 is divided by -2.
Ms is expressed in dBm in case of RSRP, or in dB in case of RSRQ.
Mn is expressed in dBm or dB, depending on the measurement quantity of the inter-RAT
neighbor cell.
Ofn, Hys are expressed in dB.
Thresh1 is expressed in the same unit as Ms.
Thresh2 is expressed in the same unit as Mn.
3.1.3
Intra-Freq Measurement
Intra-Freq measurement aims at Intra-Freq cells measurement (including serving cell),
and the measurement report can be periodical report or event-triggered report. The
measurement quantity can be RSRP or RSRQ.
3.1.3.1
Measurement Filtering
To avoid measurement fluctuation while performing Intra-Freq measurement, the UE
can perform Layer 3 filtering used for all events evaluation and related reporting of that
measurement type. The filtering formula is shown below:
Fn = (1 a ) Fn 1 + a M n
Where:
Fn-1
Fn
is the updated filter measurement result, that is used for evaluation of reporting
criteria or for measurement reporting
Mn
a = 1/2(k/4)
is the factor calculated according to filter coefficient KFilter Coefficient
for RSRP or Filter Coefficient for RSRQ
12
3.1.3.2
Measurement Establishment
When RRC connection has been established, the information of Intra-Freq
measurement will be sent to UE in the first RRCConnectionReconfiguration message
containing information for UE context setup. When UE handovers from the other RAT to
LTE, the information of Intra-Freq measurement will be sent in the
RRCConnectionReconfiguration message.
When
RRC
connection
has
been
established
and
the
first
RRCConnectionRecongfiguration has been send, Event A2 for redirection judgement
should be sent if these conditions below can be satisfied:
3.1.3.3
But UE radio capability or network does not support handover to the neighbouring
cell;
Measurement Modification
In the condition that Intra-Freq measurement has been activated, the Intra-Freq
measurement may be modified on the following occasions:
1
If Event A2 measurement has not been activated and there are Inter-Freq
neighboring cells, Event A2 measurement configuration can be sent to the UE;
If Event A2 for redirection has been sent and eNB modifies Event A2 threshold
into Event A2 threshold for starting Inter-Freq/ Inter-RAT measurement;
13
3.1.3.4
Measurement Release
When the UE moves to RRC_IDLE state, the UE shall release all the Intra-Freq
measurements automatically without any message notification.
3.1.4
Inter-Freq Measurement
Inter-Freq measurement means that UE performs measurement on neighboring cells of
non-serving frequency carrier. The measurement report can be periodical or eventtriggered. Among all of the events, Event A1 and A2 are measurements on serving
frequency carrier. Therefore, measurement gap is not needed and will not introduce
extra overhead to UE and the network. Event A1 and A2 can serve to activate and
deactivate the measurement gap. Accordingly, when the service is established, if the
serving cell has Inter-Freq neighboring cells, the eNodeB may send Event A1/A2 in
addition to Intra-Freq measurement to the UE. The following measurement
establishment, modification, release are all targeted at Inter-Freq measurement other
than Event A1/A2.
3.1.4.1
Measurement Filtering
To avoid measurement fluctuation while performing Inter-Freq measurement, the UE
shall perform Layer 3 filtering used for all event evaluation and related reporting of that
measurement type. The Layer 3 filtering related factor is Filter Coefficient for RSRP or
Filter Coefficient for RSRQ. The application principle is similar to the formula used for
Intra-Freq measurement filtering.
3.1.4.2
Measurement Establishment
Inter-Freq measurement is only established after Event A2 reporting.
3.1.4.3
Measurement Modification
Inter-Freq measurement is modified after intra-or Inter-Freq handover.
3.1.4.4
Measurement Release
The eNB shall deactivate the Inter-Freq measurement after Event A1 reporting or when
UE moves to RRC_IDLE state. For the latter case, the Inter-Freq measurement can be
released automatically without any notification to the UE.
3.1.5
Inter-RAT Measurement
Inter-RAT measurement refers to that UE performs measurement on the adjacent cell of
non serving system. For all the measurement events, Event A1 and Event A2 are for
serving carrier frequency measurements, and during the measurement it is not
necessary to activate measurement gap and it shall not bring additional overhead to the
UE and the system. According to Event A1 and Event A2 definitions, Inter-RAT
measurement can be used to activate and deactivate the measurement gap. Therefore,
14
at service establishment, if there exist inter-RAT adjacent cells, eNodeB shall send
Event A1/A2 to the UE. The later measurement establishment, modification and release
all aim at Inter-RAT measurement Events except Event A1/A2. Inter-RAT measurement
report events are mainly Event B1 and Event B2. For detailed description, please see
the relevant Section 3.1.2.2.
3.1.5.1
Measurement Filtering
To avoid measurement fluctuation while performing inter-RAT measurement, the UE can
perform Layer 3 filtering on measurement result, and then perform event judgment and
report according to the filtered value. GERAN Layer 3 filter factor is byFilterCoeffGera,
and UTRAN Layer 3 factor is byFilterCoeffUtra . For the principle, please refer to
Intra-Freq measurement Filter Formula.
3.1.5.2
Measurement Establishment
Inter-RAT measurement is only established after Event A2 reporting.
3.1.5.3
Measurement Modification
Inter-RAT measurement is modified after Inter-RAT handover.
3.1.5.4
Measurement Release
The eNB shall deactivate the Inter-RAT measurement after Event A1 reporting or when
UE moves to RRC_IDLE state. For the latter case, the Inter-RAT measurement can be
released automatically without any notification to the UE.
3.1.6
3.1.6.1
15
3.1.6.2
Figure 1
Transmission
at eNB
DL #1
DL #0
DL #0
DL #9
DL #8
DL #7
DL #6
DL #5
DL #4
DL #3
DL #2
DL measurement gap
Propagation delay
Reception
at UE
DL #0
DL #1 DL #2
DL #3
DL #4
DL #6
DL #5
DL #7
DL #8
DL #9
DL #0
DL measurement gap
DL/UL offset by TA
Transmission
at UE
UL #0
UL #1
UL #2
UL #3
UL #4
UL #5
UL #6
UL #7
UL #8
UL #9
UL #0
UL #1
UL measurement gap
Propagation delay
Reception
at eNB
UL #0
UL #1
UL #2
UL #3
UL #4
UL #5
UL #6
UL #7
UL #8
UL #9
UL #0
UL #1
UL measurement gap
16
Figure 2
subframe
Transmission
at eNB
DL #0
DL #1
DL #2
DL #3
DL #4
DL #5
DL #6
DL #7
DL #8
DL #9
DL #0
DL #6
DL #7
DL #8
DL #9
DL #0
UL #6
UL #7
UL #8
UL #9
UL #0
UL #1
UL #9
UL #0
UL #1
DL measurement gap
Reception
at UE
DL #0
DL #1 DL #2
DL #3
DL #4
DL #5
DL measurement gap
Transmission
at UE
UL #0
UL #1
UL #2
UL #3
UL #4
UL #5
UL measurement gap
Reception
at eNB
UL #0
UL #1
UL #2
UL #3
UL #4
UL #5
UL #6
UL #7
UL #8
UL measurement gap
3.1.6.3
3.1.6.4
3.1.6.5
UE radio capability information indicates that the Inter-Freq measurement or interRAT measurement needs measurement gap;
Intra-Freq measurement and inter-RAT measurement are both turned off (Event A1
triggering or measurement gap activation conditions are not fulfilled any longer)
17
3.1.6.6
3.2
3.2.1
Judge the first cell in the measurement report cell list is the intra-eNodeB cell or
Inter-eNodeB cell.
1. If the first cell in the measurement report cell list is the intra-eNodeB cell, the
procedure is as follows: Initiate handover request and attemp to access. If all the
services of the UE are accepted, move the Step 2. Otherwise, jump to Step 3.
2. Execute Intra-RAT handover. Handover to the target cell of successful access. Jump
to Step 5 after the handover complete.
3. If some intra-eNodeB byHoPartCacSwicth for access handover are switched on, judge
whether the UE services are accessed successfully or not. If one service is
accepted, jump to Step 4. Otherwise, delete the cell of best quality in the target cell
list and move the next step (some byHoPartCacSwicth are switched off or all
services access failure).
4. Judge Whether there is a cell secondary to the best cell in the target handover cell list.
If Yes, jump to the step that judges the cell is intra-eNodeB cell or Inter-eNodeB cell.
If No, move the next step.
5. The procedure ends.
18
If the first cell in the measurement report cell list is the inter-eNodeB cell, the
procedure is as follows:
1. Initiate handover preparation to the eNodeB, and move to the next step if handover
preparation is success. Jump to Step 3 if receiving HANDOVER PREPARATION
FAILURE.
2. Execute Intra-RAT handover. Handover to the target cell and move to the next step
after the handover complete.
3. The procedure ends.
3.3
3.3.1
3.3.2
19
3.4
3.4.1
3.4.2
Handover Handling
Load balancing result indicates the UEs to be handovered and target handover cell list.
By the OMC field ucLBMaxHOCell, the maximum cell number which UE attempts to
access can be configured. eNodeB judges whether the cell list number is larger than the
ucLBMaxHOCell. If yes, the first ucLBMaxHOCell cells are regarded as the target cells.
Otherwise, the target handover cell list remains unchanged. The UE attempts to
handover to all the cells in the cell list until the handover is successful and UE receives
Handover Command. If all the attempts fail, the load balancing is regarded as failure and
wait for the next load balancing.
3.5
3.5.1
Handover to GERAN
The handover from LTE to GERAN can be divided into PS HO, SRVCC, and CCO.
When adopting CCO procedure, eNB needs to configure OMC parameter bySwitchNacc
indicating whether the target GERAN cell supports NACC or not. If the target GERAN
cell supports NACC, the eNB can obtain the system information of the target GERAN
cell via RIM procedure, shortening delay from CCO to target GERAN cell.
20
3.5.1.1
3.5.1.2
3.5.2
Handover to UTRAN
LTE handover to UTRAN consists of PS HO or SRVCC. SRVCC is triggered when UE
has voice service of QCI=1 and the Utran cell does not support VoIP.
3.5.2.1
21
3.5.2.2
Whether UE has services of QCI=1; Whether target UTRAN cell supports VoIP
( configured by OMC field ucUTRANNBRcellVoIPFlg); whether target UTRAN cell
supports PS HO (configured by OMC field ucUTRANNBRcellPSHOFlg).
eNodeB initiates PS HO when:
1.
UE has no services of QCI=1 and the target UTRAN cell supports PS HO;
2.
UE has services of QCI=1 and the target UTRAN cell supports VoIP.
3.6
Redirection
For mobility management application scenarios which are based on coverage, PS HO or
CCO is preferred if supported by UE and network because PH HO and CCO have better
performance in time delay than redirection. If PS HO and CCO are not supported by UE
radio capacity or the network, redirection is considered (configured by OMC parameter
byRd4Coverage).
The scenarios for this feature:
22
UE radio capacity doesnt support handover (and CCO) to Inter-Freq or(and) interRAT neighboring cell, or
Network side (including RAN or /and Core Network) temporarily cant support InterFreq or (and) inter-RAT handover (and CCO).
3.6.1
At any moment, eNB only configures one version of Event A2 for UE to perform intraFreq measurement. When UE radio capacity, network capacity, neighboring cell
configuration only satisfy one of the two Event A2 versions, eNB configures UE for the
corresponding Event A2 measurement. Event A2 report of UE shall trigger eNB to
proceed with relevant actions.
When UE radio capacity, network capacity, neighbor cell configuration can satisfy both
two versions of Event A2, Event A2 Inter-Freq/Inter-RAT measurement will be first
configured and issued. When eNB receives Event A2 reported by UE, measurement
event for Inter-Freq/Inter-RAT handover judgment will be activated. Meantime, Event A2
threshold will be modified to the Event A2 threshold for redirection judgment and Event
A1 will be issued to terminate Inter-Freq/Inter-RAT measurement. After these, if UE
reports measurement events for Inter-Freq/Inter-RAT handover judgment, eNB shall be
triggered to perform, handover judgment; if UE reports measurement event Event A2
for redirection judgment, eNB shall be triggered to perform redirection judgment; if UE
reports Event A1 for terminating Inter-Freq/Inter-RAT measurement, eNB shall be
triggered to terminate the Inter-Freq/Inter-RAT measurement of UE and adjusts Event
A2 threshold to the Event A2 threshold for starting Inter-Freq/Inter-RAT measurement.
The Event A2 threshold for redirection judgment can be based on the redirection
activating parameter which is preset in the OMC database. The activating threshold can
be based on RSRP, RSRQ of serving cell or on both at the same time. Specific choice is
differentiated through the selecting of different redirection measurement configuration.
23
3.6.2
3.7
CS Fallback to GERAN/UTRAN
By CS Fallback technology, UE can initiate CS service (calling) when UE accesses or in
camped in LTE network, and UE can receive CS service (called), and this technology
can unable UE to handle PS service properly when UE accesses to LTE network.
CS Fallback to GSM cells can be performed by PS HO, CCO or redirection method; CS
Fallback to UTRAN cells can be performed by PS HO or redirection method.
3.7.1
24
4.1
Related Parameters
4.1.1
Parameter List
Abbreviated name
Parameter name
byTrigQuan
Trigger Quantity
byReportQuan
byRptCriteria
Report Criteria
byEvtId
Event Identity
byRsrpThreshold
byRsrqThreshold
byA3offset
A3 Offset
byA5Thrd2Rsrp
byA5Thrd2Rsrq
byHysterisis
Hysteresis
byTrigTime
Time to Trigger
byRptIntvl
byRptAmt
byPrdRptInterval
byPrdRptAmount
byMaxRptCellNum
byReportOnLeave
byFilterCoeffRsrp
byFilterCoeffRsrq
byHOCandCelNum
byHoPartCacSwicth
ucLBMaxHOCell
byFilterCoeffGera
byFilterCoeffUtra
byUtranMeasQuan
byRscpSysNbrTrd
byEcNoSysNbrTrd
byRatSysNbrTrd
25
Abbreviated name
Parameter name
bySwitchNacc
byRd4Coverage
wOpenRedMeasCfg
Redirection Measurement
Configuration Index
abyRdRATPriority[6]
byDtmsupport
ucGERANNBRcellVoIPFlg
ucUTRANNBRcellVoIPFlg
ucUTRANNBRcellPSHOFlg
4.1.2
Parameter Configuration
4.1.2.1
Trigger Quantity
4.1.2.2
Parameter name
Trigger Quantity
Abbreviated name
byTrigQuan
Description
enum(rsrp, rsrq)
Unit
N/A
Default Value
rsrp
4.1.2.3
Parameter name
Abbreviated name
byReportQuan
Description
Unit
N/A
Default Value
Both
Report Criteria
Parameter name
26
Report Criteria
4.1.2.4
4.1.2.5
Abbreviated name
byRptCriteria
Description
Unit
N/A
Default Value
Event Identity
Parameter name
Event Identity
Abbreviated name
byEvtId
Description
This parameter indicates the event triggered by the InterFreq measurement, which is related to the measurement
quantity.
A1,A2,A3, A4, A5
Unit
N/A
Default Value
A1
Abbreviated name
byRsrpThreshold
Description
Unit
dBm
Default Value
4.1.2.6
-75
Abbreviated name
byRsrqThreshold
Description
27
4.1.2.7
Unit
dB
Default Value
-8
A3 Offset
4.1.2.8
Parameter name
A3 Offset
Abbreviated name
byA3offset
Description
Unit
dB
Default Value
4.1.2.9
Parameter name
Abbreviated name
byA5Thrd2Rsrp
Description
Unit
dBm
Default Value
-90
28
Parameter name
Abbreviated name
byA5Thrd2Rsrq
Description
4.1.2.10
4.1.2.11
4.1.2.12
Unit
dB
Default Value
-11
Hysteresis
Parameter name
Hysteresis
Abbreviated name
byHysterisis
Description
Unit
dB
Default Value
Time to Trigger
Parameter name
Time to Trigger
Abbreviated name
byTrigTime
Description
enum (0, 40, 64, 80, 100, 128, 160, 256, 320, 480, 512, 640,
1024, 1280, 2560, 5120)
Unit
ms
Default Value
256
Abbreviated name
byRptIntvl
Description
enum (120, 240, 480, 640, 1024, 2048, 5120, 10240, 60000,
360000, 720000, 1800000, 3600000)
Unit
Ms
29
Default Value
4.1.2.13
4.1.2.14
4.1.2.15
4.1.2.16
30
1024
Abbreviated name
byRptAmt
Description
Unit
N/A
Default Value
Abbreviated name
byPrdRptInterval
Description
enum (120, 240, 480, 640, 1024, 2048, 5120, 10240, 60000,
360000, 720000, 1800000, 3600000)
Unit
ms
Default Value
1024
Abbreviated name
byPrdRptAmount
Description
Unit
N/A
Default Value
Infinity
Abbreviated name
byMaxRptCellNum
Description
int (1, 2, , 8)
4.1.2.17
4.1.2.18
4.1.2.19
4.1.2.20
Unit
N/A
Default Value
Abbreviated name
byReportOnLeave
Description
Unit
N/A
Default Value
false
Abbreviated name
byFilterCoeffRsrp
Description
enum (0,1,2,3,4,5,6,7,8,9,11,13,15,17,19)
Unit
N/A
Default Value
Abbreviated name
byFilterCoeffRsrq
Description
enum (0,1,2,3,4,5,6,7,8,9,11,13,15,17,19)
Unit
N/A
Default Value
Abbreviated name
byHOCandCelNum
Description
enum (0,1,2,3,4,5,6,7,8)
31
4.1.2.21
4.1.2.22
4.1.2.23
4.1.2.24
32
Unit
N/A
Default Value
Abbreviated
name
byHoPartCacSwicth
Description
enum (0 , 1)
0:close;
1:open
Unit
N/A
Default Value
close
Abbreviated
name
ucLBMaxHOCell
Description
int (1, 2, , 6)
Unit
N/A
Default Value
Abbreviated name
byFilterCoeffGera
Description
enum (0,1,2,3,4,5,6,7,8,9,11,13,15,17,19)
Unit
N/A
Default Value
Abbreviated name
byFilterCoeffUtra
Description
4.1.2.25
4.1.2.26
4.1.2.27
4.1.2.28
enum (0,1,2,3,4,5,6,7,8,9,11,13,15,17,19)
Unit
N/A
Default Value
Abbreviated name
byUtranMeasQuan
Description
enum (0, 1)
0: Cpich Ec/No;
1: Cpich RSCP
Unit
N/A
Default Value
Cpich RSCP
Abbreviated name
byRscpSysNbrTrd
Description
Unit
dBm
Default Value
-95
Abbreviated name
byEcNoSysNbrTrd
Description
Unit
dB
Default Value
-24
Abbreviated name
byRatSysNbrTrd
Description
33
4.1.2.29
4.1.2.30
4.1.2.31
4.1.2.32
34
Unit
N/A
Default Value
-90
Abbreviated name
bySwitchNacc
Description
enum(close,open)
Unit
N/A
Default Value
close
Abbreviated name
byRd4Coverage
Description
enum(false,true)
Unit
N/A
Default Value
false
Abbreviated name
wOpenRedMeasCfg
Description
0~2047
Unit
N/A
Default Value
1400
Abbreviated name
abyRdRATPriority
Description
4.1.2.33
int(0,,255) step1
Unit
N/A
Default Value
[100, 0, 0, 0, 0, 0]
Abbreviated
name
byDtmsupport
Description
enum (0,1,2)
0 Supports DTM and DTM HO
1 Supports DTM , Not Support DTM HO
2 Not Support DTM
4.1.2.34
4.1.2.35
Unit
N/A
Default Value
Abbreviated
name
ucGERANNBRcellVoIPFlg
Description
Unit
N/A
Default Value
Abbreviated
name
ucUTRANNBRcellVoIPFlg
Description
Unit
N/A
Default Value
35
4.1.2.36
Abbreviated
name
ucUTRANNBRcellPSHOFlg
Description
Unit
N/A
Default Value
Supports PS HO
Glossary
1xRRT
3GPP
B
BCCH
C
CCO
CDMA2000
CIO
CS
Circuit-Switched
CSG
D
DL
Downlink
DRX
Discontinuous Reception
36
eNB
EPLMN
E-UTRAN NodeB
Equivalent PLMN
E-UTRAN
F
FDD
G
GERAN
GSM
H
HRPD
HPLMN
Home PLMN
I
ID
Identity
IMSI
L
LTE
Long-Term Evolution
M
MIB
MME
N
NAS
37
P
PS HO
Packet-switched handover
PLMN
R
RAT
RSRP
RSRQ
S
SGW
Serving GateWay
SIB
SIM
SRVCC
T
TA
Timing Advance
TA
Tracking Area
U
USIM
UE
User Equipment
UTRAN
UL
Uplink
V
VPLMN
38
Visited PLMN