You are on page 1of 2

EP 2-3K

EP 1K

HIGH PERFORMANCE TRUE DOUBLE CONVERSION ONLINE UPS


DSP Control

Auto Self-Testing System

0.8 Output Power Factor

Extendable Run Time

Wide Input Range

Fan Speed Control

High efficiency mode(ECO)

Power Management Software

Frequency Converter Mode

Multiple Communication Ports

Input THDi<5%

Optional SNMP & Relay Cards

Output Voltage Regulation <2%

Temperature Compensation

Output THDv<3%

Compact Design

2. EPO

3. Cooling Fan
4. Input Breaker

1-3K

1. USB Port

5. Input Socket *

6. Output Socket
7. Intelligent Slot

8. Battery Connector
(Option)

9. Output Terminal

EP 1K

EP 2K / EP 3K

*: EP 1K / EP 1KS / EP 2K:10A socket;

MODEL
CAPACITY

EP 2KS / EP 3K:16A socket; EP 3KS:Terminal Block


EP 1K

VA/W

EP 1KS

EP 2K

1000VA/800W

2000VA/1600W

Frequency Range

Single Phase with Ground

THDI

< 5% with Full Load


200/208220/230/240VAC

Voltage Regulation

2%

Frequency
(Synchronized Range)

45-55Hz/54-66Hz

Frequency (BAT Mode)

50/60Hz0.2Hz

Current Crest Ratio

3:1
<3% @ Linear Load

Harmonic Distortion

<5% @ Non-Linear Load

Output Waveform

Pure Sine Wave


1min @105%-110% load
30s @110%-120% load
10s@125%-150%
1s@>150%load

Line Mode
BAT Mode

Line Mode

EFFICIENCY

>88%

BAT Mode

>85%

ECO Mode
Number of Batteries
Battery Type

BATTERY

Backup Time
Recharge Time
Charging Current

TRANSFER
TIME
INDICATOR

>93%
3
12V/7Ah
>5 Minutes
5 Hours to 90%

>94%

Depending on
The Capacity
of External
Batteries

1A

8A

8A
12A (Optional)
<4ms

INV-->ECO

<4ms

ECO--> INV

<10ms

LCD

Sounding Every Second


Continuously Sounding

Relative Humidity

USB
External Slot
EPO

>5 Minutes
5 Hours to 90%

Depending on
the Capacity
of External
Batteries
8A
12A (Optional)

1A

Sounding Every 4 Seconds

Fault
Tower Case (WxHxD)mm

8
12V/7Ah

Load/Battery/Input/Output/Operating Mode Information

Battery Low

Noise Level

INTERFACE

1A

INV <--> BYPASS

Operation Environment

ENVIRONMENT

>9 Minutes
5 hours to 90%

Depending on
The Capacity
of External
Batteries

0ms

Overload Capacity

DIMENSION

8
12V/7Ah

BAT <--> LINE

BAT Mode

AUDIBLE
ALARM

3000VA/2400W

0.99

Voltage

Overload
Capacity

EP 3KS

45-55Hz / 54-66Hz

Phase
Power Factor

OUTPUT

EP 3K

110~300VAC Depends on Load Level

Voltage Range

INPUT

EP 2KS

Sounding Twice Every Second


145220400

192347460

192347460

0-45
20-90% (Non-Condensing)
<50dB @ Front 1 Meter
Software Supports Windows Family, Linux, Sun Solaris,
IBM Aix, Compaq True64, SGIIRIX, FreeBSD, HP-UX, MAC
SNMP/AS400/Relay Card
Emergency Power Off