Professional Documents
Culture Documents
Hydro-Flo Technologies, Inc
Hydro-Flo Technologies, Inc
Available
DAF Model #'s
Company
Location
This spreadsheet will calculate a DAF unit based on ppm of TSS &
FOG combined, Flow rate and acceptable A/S ratio:
Input
3000
250
1.5
80
80%
60
263
lb/gal of TSS =
Solids Loading ratio of TSS per min (lb);
Solids Loading ratio of TSS per hour (lb):
Solids Loading ratio of TSS per day (24 hr period):
Saturation Concentration (lb air/gal H2O) at atmospheric pressure
Theoretical Air Release (lb air/gal H2O)
Minimum required Sq. Ft. in DAF Unit (Separation Chamber):
gpm/sq.ft. hydraulic loading rate for Selected DAF Alone
Recirculation (RAD) Flow Rate Range
Theoretical Low End Recycle (RAD) Flow Rate (gpm):
Low end gpm/sq.ft. hydraulic loading rate for selected DAFand
theoretical RAD combined (gpm/sq.ft.):
Theoretical High End Recycle (RAD) Flow Rate (gpm):
High end gpm/sq.ft. hydraulic loading rate for the selected DAFand
theoretical RAD combined (gpm/sq.ft.):
Output
0.03
6.26
375.50
9012.10
0.0002190
0.0009098
250.34
0.95
125.00
1.4259
275.17
1.9968
5
8
11
15
20
25
31
38
45
53
61
70
80
90
101
113
125
138
151
165
180
195
211
228
245
263
281
300
320
340
361
383
405
428
451
475
500
527
592
661
735
815
900
1,088
1,191
1,301
1,416
1,539
1,668
1,805
1,945
2,150
Company
Location
This spreadsheet will calculate a DAF unit based on ppm of TSS & FOG combined, Flow rate and acceptable A/S ratio:
Input
2000.000
30.000
1.500
40.000
0.800
40.000
25.000
Output
lb/gal of TSS =
0.02
Solids Loading ratio of TSS per min (lb);
0.5007
Solids Loading ratio of TSS per hour (lb):
30.0403
Solids Loading ratio of TSS per day (24 hr period): 720.9682753
Saturation Concentration (lb sat. N2/gal H2O)
0.00
Theoretical Air Release (lb sat. N2/gal H2O)
0.00
Minimum required Sq. Ft. in DAF Unit (Separation Chamber):
20.0269
gpm/sq.ft. hydraulic loading rate for Selected DAF Alone
1.2000
Recirculation (RAD) Flow Rate Range
Theoretical Low End Recycle (RAD) Flow Rate (gpm):
Low end gpm/sq.ft. hydraulic loading rate for selected DAFand theoretical RAD combined (gpm/sq.ft.):
17.23
1.8893
45.95
3.0381
DAF Model #
5
8
11
15
25
34
45
59
74
92
113
136
163
192
226
263
303
348
397
468
527
592
661
735
815
900
1088
1191
1301
1416
1539
1668
1805
1945
2150
f(x) = 0.0000000000003890387392404780x^4
- 0.0000000002489519246667380000x^3 + 0.0000000625810829994362000000x^2 - 0.0000075210690787114000000000x + 0.0004937240162171870000000000
0.0003
R = 0.9998543788469010000000000000
SaturationConcentration(inlbair/gal H2O)
0.00025
0.0002
0.00015
0.0001
0
50
100
Temperature (in F)
150
200
250
f(x) =0.00024
0.0000000000002814456857799140x^4 - 0.0000000001821817044179250000x^3 + 0.0000000465407983743935000000x^2 - 0.0000056836326763317900000000x + 0.0003842774490242240000000000
R = 0.9996384943616440000000000000
0.00022
0.0002
0.00018
0.00016
0.00014
0.00012
0.0001
0
50
100
Temperature (in F)
150
200
250
deg C
0
5
10
15
20
25
30
35
40
45
50
60
70
80
90
100
deg F
32
41
50
59
68
77
86
95
104
113
122
140
158
176
194
212
H (Henry's Law
Constant for air)
4.32
4.88
5.49
6.07
6.64
7.2
7.71
8.23
8.7
9.11
9.46
10.1
10.5
10.7
10.8
10.7
H (Henry's Law
Constant for
atmos. Nitrogen)
5.29
5.97
6.68
7.38
8.04
8.65
9.24
9.85
10.4
10.9
11.3
12
12.5
12.6
12.6
12.6
ologies, Inc.
water Treatment