You are on page 1of 2

Hydrogen plant capacity

Energy in the natural gas to hydrogen plant


LHV of Methane
Methane requirement
Total steam requirement for 135000 kg/day of H2 plant
Amount of steam required/kg of H2
Total electricity requirement for 135000 kg/day of H2 plant
Electricity required/kg of H2
Raw material inputs for production of 1 kg of H2
Coal, hard (in ground)
Crude oil (in ground)
Iron ore (in ground)
Limestone (in ground)
Water unspecified natural origin
Water consumed in reforming and shift reactions
Water consumed in steam production
Natural gas, at production
Electricity, production mix
Steam

kg/day
MJ / kg of H2
Mj/kg
kg/kg of H2
T/Day
kg/kg of H2
MJ/day
MJ/kg of H2

g
g
g
g
m3
m3
m3
m3
kWh
Kg

135000
159.6
47.13
3.39
1290
9.6
153000
1.13

159.2
16.4
10.3
16
0.0198
0.0048
0.0141
5
0.314
8

You might also like