You are on page 1of 1

1.

Torsion stable base support with integrated discharge silencer acc. to pressure
device guideline PED 2014/68/EU, free of absorptions material, with installations
free from wear, hinged motor mounting plate as tensioning device for belt drive,
support spring construction not necessary set of vibration isolating mounts for solidborne sound isolating installation, connection housing with removable non-return
flap, maintenance without disassembly of the housing

2. Safety pressure relief valve setting point: 650 mbar ( As per blower set point)

3. Intake filter silencer, absorption material in direction of flow arranged upstream


of filter element
4. Flexible connection (ISO) with hose clamps at discharge side
5.
6.
7.
8.

Narrow V-belt drive


Start up relief device
Motor mounting
Acoustic hood made of galvanized steel plate with oil drip pan. Segmental design with
internal lining and forced ventilation, fan wheel driven by blower shaft, not any additional
aux. drive necessary. Acoustic hood is appropriate for the installation of several units side
by side. Transport possible by fork lift truck. Acoustic hood for indoor installation
9. Pressure gauge 63 mm with connection pieces
10. Service indicator for filter control
11. First Oil filling