Catalogue

2004

Merlin Gerin
Miniature circuit-breakers and
earth leakage circuit-breakers
(MCBs/ELCBs)

contents

page
Miniature circuit-breakers

RCCB / ELCB

Technical information

Mini pragma din kit

Merlin Gerin

C60a

C60N

C60H

C60N UL489 - DC circuit breaker

DC circuit breaker - application guide

C120N

C120H

13

NC100L

17

NC100LH

19

electrical auxiliaries C60, C120

21

electrical auxiliaries NC100

22

instantaneous RCCB/ELCB, selective RCCB/ELCB

24

electrical auxiliaries RCCB/ELCB

26

discrimination

28

cascading

30

dimensions

31

semi-equipped consumer unit

32

circuit protection

C60a Miniature circuit-breakers


B and C tripping curves
IEC 898: 4500 , IEC 947-2: 5kA
type
1P

width in mod.
of 9 mm
2

B and C curves

rat
(A)
6
10
16
20
25
32
40

Cat No.
B curve
23555
23556
23557
23559
23560
23561
23562

C curve
23849
23850
23851
23852
23853
23854
23855

Application
control and protection of circuits against
overloads and short-circuits.
c in domestic installation;
c in commercial and industrial electrical
distribution systems.

6
10
16
20
25
32
40

23571
23572
23573
23574
23575
23577
23578

23863
23864
23865
23866
23867
23868
23869

rat.
type
(A)
to IEC 898
6 to 40 1P
2, 3P

1 protected pole
23849
2P

1 3

2 4

Technical data
c current rating: 6 to 40A;
c voltage rating: 230-400 V AC;
c breaking capacity:
v Icn ultimate breaking capacity (O-CO cycle):

23863
3P

1 3 5

6
10
16
20
25
32
40

23586
23587
23589
23590
23591
23592
23593

2 4 6

3 protected poles

23877

23877
23878
23880
23881
23882
23885
23886

breaking
capacity (A)

230-240
400-415

4500
4500

v Icn = Icn = 4.5 kA,


v Icn ultimate breaking capacity (O-CO cycle):
rat.
type
(A)
to IEC 947-2
6 to 40 1P

2 protected poles

voltage
(V)

2, 3P

voltage
(V)

breaking
capacity (A)

130
230-240
400-415
230-240
400-415
440

10000
5000
3000
10000
5000
3000

c fast closing contacts;


c number of operating cycles (O-C); 20000;
c tripping characteristics:
v B curve: the magnetic releases operate
between 3 and 5 In;
v C curve: the magnetic releases operate
between 5 and 10 In;
c impulse withstand voltage (U imp.): 6 kV;
c tropicalization: treatment 2 (relative
humidity 95 % at 55 C);
c weight (g):
type

1P
110

2P
220

3P
340

c connections: tunnel terminals for rigid


cables up to:
v 25 mm2 for rating < 25A,
v 35 mm2 for rating 32 to 40 A;
c installation: in all enclosures designed for
Multi 9 equipment.

additional information

electrical auxiliaries: page 21


dimensions: page 31

Merlin Gerin

circuit protection

C60N Miniature circuit-breakers


B, C and D tripping curves
IEC 898: 6000 , IEC 947-2: 10kA

24395

24331

24344

24357

additional information

Merlin Gerin

width in mod. rat Cat No.


of 9 mm
(A) B curve
1P
2
1 24045
2 24046
1
3 24047
4 24048
6 24049
10 24050
16 24051
2
20 24052
25 24053
1 protected pole
32 24054
40 24055
50 24056
63 24057
2P
4
1 24071
2 24072
1 3
3 24073
4 24074
6 24075
10 24076
16 24077
20 24078
2 4
25 24079
2 protected poles
32 24080
40 24081
50 24082
63 24083
3P
6
1 24084
2 24085
1 3 5
3 24086
4 24087
6 24088
10 24089
16 24090
2 4 6
20 24091
25 24092
3 protected poles
32 24093
40 24094
50 24095
63 24096
4P
8
1 24097
2 24098
1 3 5 7
3 24099
4 24100
6 24101
10 24102
16 24103
20 24104
2 4 6 8
25 24105
3 protected poles
32 24106
40 24107
50 24108
63 24109

B, C and D curves

type

C curve
24395
24396
24397
24398
24399
24401
24403
24404
24405
24406
24407
24408
24409
24331
24332
24333
24334
24335
24336
24337
24338
24339
24340
24341
24342
24343
24344
24345
24346
24347
24348
24349
24350
24351
24352
24353
24354
24355
24356
24357
24358
24359
24360
24361
24362
24363
24364
24365
24366
24367
24368
24369

D curve
24625
24626
24627
24628
24629
24630
24632
24633
24634
24635
24636
24637
24638
24653
24654
24655
24656
24657
24658
24660
24661
24662
24663
24664
24665
24666
24667
24668
24669
24670
24671
24672
24674
24675
24676
24677
24678
24679
24680
24681
24682
24683
24684
24685
24686
24688
24689
24690
24691
24692
24693
24694

Application
control and protection of circuits against
overloads and short-circuits.
c in domestic installation;
c in commercial and industrial electrical
distribution systems;
c D curve: more particularly adapted for
installations with high transient currents (LV/
LV transformers, motors,...).
Technical data
c current rating: 1 to 63 A;
c voltage rating: 230-400 V AC;
c breaking capacity:
v Icn ultimate breaking capacity (O-CO cycle):
rat.
type
(A)
to IEC 898
1 to 63 1P
2, 3, 4P

voltage
(V)

breaking
capacity (A)

230-240
400-415

6000
6000

v Ics = Icn = 6 kA,


v Icn ultimate breaking capacity (O-CO cycle):
rat.
type
(A)
to IEC 947-2
1 to 63 1P

2, 3, 4P

voltage
(V)

breaking
capacity (A)

130
230-240
400-415
230-240
400-415
440

20000
10000
3000
20000
10000
6000

c fast closing contacts;


c number of operating cycles (O-C); 20000;
c tripping characteristics:
v B curve: the magnetic releases operate
between 3 and 5 In;
v C curve: the magnetic releases operate
between 5 and 10 In;
v D curve: the magnetic releases operate
between 10 and 14 In;
c impulse withstand voltage (U imp.): 6 kV;
c tropicalization: treatment 2 (relative
humidity 95% at 55C);
c weight (g):
type

1P
110

2P
220

3P
340

4P
450

c connections: tunnel terminals for rigid


cables up to:
v 25 mm2 for rating < 25 A,
v 35 mm2 for rating 32 to 63 A;
c approvals: Marine, (consult us)
c installation: in all enclosures designed for
Multi 9 equipment.

electrical auxiliaries: page 21


dimensions: page 31

circuit protection

C60H Miniature circuit-breakers


B, C and D tripping curves
IEC 898: 10000 , IEC 947-2: 15kA

24900

24902

24906

24908

additional information

width in mod. rat Cat No.


of 9 mm
(A) B curve
1P
2
0.5
0.75
1
1
2
3
4
6 24643
2
10 24644
16 24646
1 protected pole
20 24647
25 24648
32 24649
40 24650
50 24651
63 24652
2P
4
0.5
0.75
1 3
1
2
3
4
6 24725
10 24726
2 4
16 24727
2 protected poles
20 24728
25 24729
32 24730
40 24731
50 24732
63 24733
3P
6
0.5
0.75
1 3 5
1
2
3
4
6 24738
2 4 6
10 24739
16 24740
3 protected poles
20 24741
25 24742
32 24743
40 24744
50 24745
63 24746
4P
8
0.5
0.75
1 3 5 7
1
2
3
4
6 24751
10 24752
2 4 6 8
16 24753
4 protected poles
20 24754
25 24755
32 24756
40 24757
50 24758
63 24759

B, C and D curves

type

C curve
24900
24901
24968
24969
24970
24971
24972
24973
24974
24975
24976
24977
24978
24979
24980
24902
24903
24981
24982
24983
24984
24985
24986
24987
24988
24989
24990
24991
24992
24993
24906
24907
24994
24995
24996
24997
24998
24999
25000
25001
25002
25003
25004
25005
25006
24908
24909
25007
25008
25009
25010
25011
25012
25013
25014
25015
25016
25017
25018
25019

D curve
25171
25152
25155
25157
25158
25159
25160
25161
25164
25165
25166
25167
25168
25169
25172
25183
25184
25185
25186
25187
25188
25189
25190
25191
25192
25193
25194
25195
25173
25196
25197
25198
25199
25200
25201
25202
25203
25205
25207
25208
25209
25210
25174
25211
25212
25213
25214
25215
25216
25217
25218
25219
25220
25221
25222
25223

Application
control and protection of circuits against
overloads and short-circuits.
c in domestic installation;
c in commercial and industrial electrical
distribution systems;
c D curve: more particularly adapted for
installations with high transient currents (LV/
LV transformers, motors,...).
Technical data
c current rating: 0.5 to 63 A;
c voltage rating: 230-400 V AC;
c breaking capacity:
v Icn ultimate breaking capacity (O-CO cycle):
rat.
type
(A)
to IEC 898
1 to 63 1P
2, 3, 4P

voltage
(V)

breaking
capacity (A)

230-240
400-415

1000
1000

v Ics = 75% of Icn,


v Icu ultimate breaking capacity (O-CO cycle):
rat.
type
(A)
to IEC 947-2
1 to 63 1P

2, 3, 4P

voltage
(V)

breaking
capacity (A)

130
240
415
240
415
440

30000
15000
4000
30000
15000
10000

c positive contact indication;


c fast closing contacts;
c number of operating cycles (O-C); 20000;
c tripping characteristics:
v B curve: the magnetic releases operate
between 3 and 5 In;
v C curve: the magnetic releases operate
between 5 and 10 In;
v D curve: the magnetic releases operate
between 10 and 14 In;
c impulse withstand voltage (U imp.): 6 kV;
c tropicalization: treatment 2 (relative
humidity 95% at 55C);
c weight (g):
type

1P
110

2P
220

3P
340

4P
450

c connections: tunnel terminals for rigid


cables up to:
v 25 mm2 for rating < 25 A,
v 35 mm2 for rating 32 to 63 A;
c approvals: Marine, (consult us)
c installation: in all enclosures designed for
Multi 9 equipment.

electrical auxiliaries: page 21


dimensions: page 31

Merlin Gerin

circuit breakers

C60 N UL 489
CSA 22.2 No 5.1
UL Listed
for branch circuit protection
DC
Main functions of C60N UL 489
circuit breaker:
- protection of circuits against:
- short circuit currents
- overload currents
- control
- isolation
Various applications:
- semi-conductors
- electronic machinery
- control panel
- metal working
- telecommunication
- food, beverage
- packaging
- crane
- conveyors
- pumps and compressors
- HACR (Heating, Air
conditioning, Refrigeration)
- engine generators

Compliance with standards


c UL 489 circuit breakers File #E215117
c CSA C22.2 No. 5.1 circuit breakers File #179014
c IEC 60947-2, VDE 0660
c CE Marked
Standard features
c Power circuit:
v voltage rating: 120 up to 240 Vac (delta)
v ampere interrupting ratings:
rating (A) number of voltage
77F/25C poles 0.71 in.
(18 mm)
0.5-35
1P
2P/3P

1P
2P

interrupting rating
(kA rms)
120 Vac
240 Vac
240 Vac
415 Vac
440 Vac
65 Vdc
125 Vdc

UL 489 / CSA
10
5
10
-

IEC 60947.2
10
20
10
6
10
10

v fast closing: allows increased withstand of the high inrush currents of some loads
v current limiting
v trip-free mechanism: contacts cannot be held in the ON position when the circuit breaker is
tripped automatically
v isolation with position break indication - Green strip on the circuit breaker operating handle
indicates that all poles open
v number of operating cycles (0-C):
- electrical: 10,000
- mechanical: 20,000
c Environment:
v tropicalization: treatment 2 (relative humidity: 95% at 131F/55C)
v degree of protection:
- case: IP40 as per IEC 60529
- terminals: IP20
v temperature:
-operation: -22 to 158F (-30 to 70C)
- storage: -40 to 176F (-40 to 80C)
c Weight (oz./g):
type
C60N

1P
3.88/110

2P
7.75/220

3P
11.64/330

058976N

Connection
The C60N UL 489 is available in box lug/box lug connection

box lug/box lug

Merlin Gerin

circuit breakers

C60 N UL 489
CSA 22.2 No 5.1
UL Listed
for branch circuit protection
DC

058979N

Connection caracteristics
c Box lug UL 486A File #216919:
v 0.5-25 A: (#18-#4 AWG) 1-25mm2 cables, torque 22 Ib.in
v 30-35 A: (#18-#2 AWG) 1-35mm2 cables, torque 31 Ib.in

box lug

Adaptable electrical auxiliaries


c Remote tripping:
v shunt trip (MX + OF)
v undervoltage release (MN)
c Remote indication:
v auxiliary switch (OF)
v alarm switch (SD)
Time-current curves
C curve - Overcurrent protection for all application types:
c Ratings: 0.5-35 A set at 77F (25C)
c Tripping curve: The magnetic releases operates between 7 and 10 times ampere rating
D curve - Overcurrent protection for loads with high inrush currents
(motors, transformers etc.):
c Ratings: 0.5-35 A set at 77F (25C)
c Tripping curve: The magnetic releases operates between 10 and 14 times ampere rating

Merlin Gerin

circuit breakers

C60 N UL 489
CSA 22.2 No 5.1
UL Listed
for branch circuit protection
DC
Box lug / box lug connection (upstream / downstream)
type

width in
modules
0.354 in.
(9 mm)
2

E27969

058976N

1P

E27970

058977N

2P

1 3

2 4

E27971

058978N

3P

1 3 5

2 4 6

additional information

Merlin Gerin

rating
(A)

reference
C curve

D curve

0.5
1
1.5
2
3
4
5
6
7
8
10
13
15
20
25
30
35
0.5
1
1.5
2
3
4
5
6
7
8
10
13
15
20
25
30
35
1
1.5
2
3
4
5
6
7
8
10
13
15
20
25
30
35

60100
60101
60102
60103
60104
60105
60106
60107
60108
60109
60110
60111
60112
60113
60114
60115
60116
60134
60135
60136
60137
60138
60139
60140
60141
60142
60143
60144
60145
60146
60147
60148
60149
60150
60168
60169
60170
60171
60172
60173
60174
60175
60176
60177
60178
60179
60180
60181
60182
60183

60117
60118
60119
60120
60121
60122
60123
60124
60125
60126
60127
60128
60129
60130
60131
60132
60133
60151
60152
60153
60154
60155
60156
60157
60158
60159
60160
60161
60162
60163
60164
60165
60166
60167
60184
60185
60186
60187
60188
60189
60190
60191
60192
60193
60194
60195
60196
60197
60198
60199

electrical auxiliaries: page 21


dimensions: page 31

application guide

DC circuit-breakers

selecting
the circuit breaker

The selection of type of circuit breaker most


suitable for protection of a DC installation
depends mainly of the following criteria:
c the rated current, which determines the
rating of the equipment
c the type of system (1,2 or 3) (see below)

c the rated voltage, which determines the


number of poles to be involved in breaking
c the maximum short-circuit current at the
point of installation. which determines the
breaking capacity

calculation of the
short-circuit current (ISC)
at the terminals of a battery

When a short-circuit occurs at its terminals, a


battery discharges a current given by ohms law:

c internal resistance: 0.5 m per cell

IC = Vb
Ri
ISC

where Vb = the maximum discharge voltage


(battery 100% charged)
and Ri = the internal resistance equivalent to
the sum of the cell resistances (figure
generally given by the manufacturer in terms
of Ampere-hour capacity of the battery).

Ri = 110 x 0.5 x 10-3


ISC =

example
What is the short-circuit current at the
terminals of standing battery with the
following characteristics:
c capacity: 500 Ah
c maximum discharge voltage:
240V (110 cells of 2.2 V)
c discharge current: 300 A
c autonomy: 30 mm

240
= 4.4kA
66 x 10-3

As the above calculation shows, the shortcircuit current relatively weak.


Note: If the internal resistance is not known,
the following aproximate formula can be used:
ISC = kC, where C is capacity of the battery
expressed in Ampere-hours, and k is a
coefficient close to 10 but in any case
always lower than 20.

arrangement of breaking poles according to the type of system


system 1
the source has one
polarity earthed
i

circuit diagrams
and differrent
kinds of fault

+
U

fault A

system 3
the source is
isolated from earth
i

+
B

analysis
of each
fault

system 2
the source has a middle
point earthed

+
U/2
+
U/2

R
B
b

maximum ISC:
only the positive polarity
is involved
maximum ISC:
both polarities involved
no consequences

ISC close to max. ISC:


only the positive polarity
is involved, at half voltage U/2
maximum ISC:
both polarities involved
as per fault A, but the
polarity is involved

no consequences

the worst case

fault A

fault A and C

fault B

arrangement
of breaking
poles

all poles needed for breaking


are placed in series on the
positive polarity (1), (2)

number of poles necessary


to break max. ISC at voltage U/2
should be placed on each polarity

number of poles necessary


for breaking should be split
between the two polarities

example: U = 250 V,
current I = 47 A.
If a NC100LS is used,
one pole is enough
to break 250 V
A single pole unit is therefore
needed

example: U = 250 V,
current I = 100 A,
ISC = 15 kA.
Each pole will be subjected
to a max. voltage U/2 = 125 V.
With a NC100
(breaking cap. = 20 kA),
2 poles are involved in
breaking a voltage of 125 V.
A four pole NC100 is needed,
with 2 poles in series
in each polarity

example: U = 125 V,
current I = 80 A.
If a NC100 is used
(breaking cap. = 20 kA)
2 poles are involved
to break U = 125 V
A two pole unit is needed,
with one pole on each polarity

fault B
fault C

+
(1) or negative if the positive polarity
earthed.
(2) an extra pole will be needed
on the earthed polarity
to provide isolation

to load

to load

maximum ISC:
both polarities involved
no consequences

to load

Merlin Gerin

circuit protection

C120N Miniature circuit-breakers


B, C and D curves
IEC 898: 10000 - IEC 947-2: 10 kA
function

c protection of cables against overloads and


short-circuits in final distribution
c manual control and isolation

c earth leakage protection when combined


with a Vigi C120 module without
temperature derating
c remote tripping, indication, by adding
auxiliaries common to the entire C60/C120
range

description

Technical data
c current rating: 63 to 125 A
c voltage rating Ue max.: 440 V AC
c insulation voltage Ui: 500 V
c impulse withstand voltage Uimp: 6 kV
c compliance with standard IEC 898:
devices accessible by inexperienced
persons
c breaking capacity:
v as in IEC 898

c approval: IMQ
c connection:
v flexible cables: 1.5 to 35 mm2
v rigid cables: 1 to 50 mm2
v terminals ensure:
-degree of protection IP2
-tightening of wide cross-section cables
-pull-out withstand of cables
-automatic guiding of cable into the correct
position
c markers:
v 4 marker clips next to the upstream
terminal
v label holder on handle (2P, 3P, 4P)
c degree of pollution: 3 (for use in an
industrial environment)
c degree of protection:
v open or surface mounted device: IP2
v in a Pragma or Prisma enclosure: IP4
(IPxxD)

type

voltage
(V)
230...400

1, 2, 3, 4P

breaking cap.
Icn (A)
10000

v as in IEC 947-2 (Icu)


type

voltage
breaking cap.
(V)
Icu (kA)
1P
130
20
230...240
10
400...415
3 (1)
2, 3, 4P
230...240
20
400...415
10
440
6
(1) breaking capacity under 1 pole with IT isolated
neutral system (case of double fault)

c service breaking capacity


Ics =75 % Icu
c positive break indication
c fast closing ensures simultaneous closing
of poles
c electrical durability:
v 63 A: 10000 cycles (O-C)
v 80...125 A: 5000 cycles (O-C)
c limitation class: 3
c mechanical durability:
20000 cycles (O-C)
c bistable fixing pawl: simplifies disassembly
c weight (g):
1P
205

Merlin Gerin

2P
410

3P
615

4P
820

B curve
c magnetic trip units operate between
3 and 5 In
c protection of very long cables
c protection of networks supplied by
generators

C curve
c magnetic trip units operate between
5 and 10 In
c protection of standard networks

D curve
c magnetic trip units operate between
10 and 14 In
c protection of circuits that supply high
inrush current loads: transformers, motors,
etc.

circuit protection

C120N Miniature circuit-breakers


B curve
IEC 898 : 10000 - IEC 947-2: 10 kA
catalogue numbers

type

rating
(A)

catalogue
number

width
in mod.
of 9 mm

63
80
100
125

18340
18341
18342
18343

3
3
3
3

63
80
100
125

18344
18345
18346
18347

6
6
6
6

63
80
100
125

18348
18349
18350
18351

9
9
9
9

63
80
100
125

18352
18353
18354
18355

12
12
12
12

B curve C120N
1P
1

2
18340

2P
1 3

2 4
18344

3P
1 3 5

2 4 6
18349

4P
1 3 5 7

2 4 6 8
18355

additional
information
10

electrical auxiliaries: page 21


dimensions: page 31

Merlin Gerin

circuit protection

C120N Miniature circuit-breakers


C curve
IEC 898 : 10000 - IEC 947-2: 10 kA
catalogue numbers

type

rating
(A)

catalogue
number

width
in mod.
of 9 mm

63
80
100
125

18356
18357
18358
18359

3
3
3
3

63
80
100
125

18360
18361
18362
18363

6
6
6
6

63
80
100
125

18364
18365
18367
18369

9
9
9
9

63
80
100
125

18371
18372
18374
18377

12
12
12
12

C curve C120N
1P
1

2
18356

2P
1 3

2 4
18360

3P
1 3 5

2 4 6
18365

4P
1 3 5 7

2 4 6 8
18377

additional
information
Merlin Gerin

electrical auxiliaries: page 21


dimensions: page 31

11

circuit protection

C120N Miniature circuit-breakers


D curve
IEC 898 : 10000 - IEC 947-2: 10 kA
catalogue numbers

type

rating
(A)

catalogue
number

width
in mod.
of 9 mm

63
80
100
125

18378
18379
18380
18381

3
3
3
3

63
80
100
125

18382
18383
18384
18385

6
6
6
6

63
80
100
125

18386
18387
18388
18389

9
9
9
9

63
80
100
125

18390
18391
18392
18393

12
12
12
12

D curve C120N
1P
1

2
18378

2P
1 3

2 4
18385

3P
1 3 5

2 4 6
18389

4P
1 3 5 7

2 4 6 8

18393

additional
information
12

electrical auxiliaries: page 21


dimensions: page 31

Merlin Gerin

circuit protection

C120H Miniature circuit-breakers


B, C and D curves
IEC 898 : 15000 - IEC 947-2: 15 kA
function

c protection of cables against overloads and


short-circuits in final distribution
c manual control and isolation

c earth leakage protection when combined


with a Vigi C120 module without
temperature derating
c remote tripping, indication, by adding
auxiliaries common to the entire C60/C120
range

description

Technical data
c current rating: 10 to 125 A
c max. voltage rating Ue: 440 V AC
c insulation voltage Ui: 500 V
c impulse withstand voltage Uimp: 6 kV
c complies with standard IEC 898: devices
accessible by unexperienced persons
c breaking capacity:
v as in IEC 898

c approval: IMQ
c connection:
v flexible cables: 1.5 to 35 mm2
v rigid cables: 1 to 50 mm2
v terminals ensure:
-degree of protection IP2
-tightening of wide cross-section cables
-pull-out withstand of cables
-automatic guiding of cable into the correct
position
c markers:
v 4 marker clips next to the upstream
terminal
v label holder on handle (2P, 3P, 4P)
c degree of pollution: 3 (for use in an
industrial environment)
c degree of protection:
v open or surface mounted device: IP2
v in a Pragma or Prisma enclosure: IP4
(IPxxD)

type

voltage
(V)
230...400

1, 2, 3, 4P

breaking cap.
Icn (A)
15000

v as in IEC 947-2 (Icu)


type

voltage
breaking cap.
(V)
Icu (kA)
1P
130
30
230...240
15
400...415
4.5 (1)
2, 3, 4P
230...240
30
400...415
15
440
10
(1) breaking capacity under 1 pole with IT isolated
neutral system (case of double fault)

c service breaking capacity


Ics =50 % Icu
c positive break indication
c fast closing ensures simultaneous closing
of poles
c electrical durability:
v 63 A: 10000 cycles (O-C)
v 80...125 A : 5000 cycles (O-C)
c limitation class: 3
c mechanical durability:
20000 cycles (O-C)
c bistable fixing pawl: simplifies disassembly
c weight (g):
1P
205

Merlin Gerin

2P
410

3P
615

4P
820

B curve
c magnetic trip units operate between
3 and 5 In
c protection of very long cables
c protection of networks supplied by
generators

C curve
c magnetic trip units operate between
5 and 10 In
c protection of standard networks

D curve
c magnetic trip units operate between
10 and 14 In
c protection of circuits that supply high
inrush current loads: transformers, motors,
etc.

13

circuit protection

C120H Miniature circuit-breakers


B curve
IEC 898 : 15000 - IEC 947-2: 15 kA
catalogue numbers

type

rating
(A)

catalogue
number

width
in mod.
of 9 mm

10
16
20
25
32
40
50
63
80
100
125

18394
18395
18396
18397
18398
18399
18400
18401
18402
18403
18404

3
3
3
3
3
3
3
3
3
3
3

10
16
20
25
32
40
50
63
80
100
125

18405
18406
18407
18408
18409
18410
18411
18412
18413
18414
18415

6
6
6
6
6
6
6
6
6
6
6

10
16
20
25
32
40
50
63
80
100
125

18416
18417
18418
18419
18420
18421
18422
18423
18424
18425
18426

9
9
9
9
9
9
9
9
9
9
9

10
16
20
25
32
40
50
63
80
100
125

18427
18428
18429
18430
18431
18432
18433
18434
18435
18436
18437

12
12
12
12
12
12
12
12
12
12
12

B curve C120H
1P
1

2
18394

2P
1 3

2 4
18412

3P
1 3 5

2 4 6
18424

4P
1 3 5 7

2 4 6 8
18437

additional
information
14

electrical auxiliaries: page 21


dimensions: page 31

Merlin Gerin

circuit protection

C120H Miniature circuit-breakers


C curve
IEC 898 : 15000 - IEC 947-2: 15 kA
catalogue numbers

type

rating
(A)

catalogue
number

width
in mod.
of 9 mm

10
16
20
25
32
40
50
63
80
100
125

18438
18439
18440
18441
18442
18443
18444
18445
18446
18447
18448

3
3
3
3
3
3
3
3
3
3
3

10
16
20
25
32
40
50
63
80
100
125

18449
18450
18451
18452
18453
18454
18455
18456
18457
18458
18459

6
6
6
6
6
6
6
6
6
6
6

10
16
20
25
32
40
50
63
80
100
125

18460
18461
18462
18463
18464
18465
18466
18467
18468
18469
18470

9
9
9
9
9
9
9
9
9
9
9

10
16
20
25
32
40
50
63
80
100
125

18471
18472
18473
18474
18475
18476
18477
18478
18479
18480
18481

12
12
12
12
12
12
12
12
12
12
12

C curve C120H
1P
1

2
18445

2P
1 3

2 4
18456

3P
1 3 5

2 4 6
18468

4P
1 3 5 7

2 4 6 8
18481

additional
information
Merlin Gerin

electrical auxiliaries: page 21


dimensions: page 31

15

circuit protection

C120H Miniature circuit-breakers


D curve
IEC 898 : 15000 - IEC 947-2: 15 kA
catalogue numbers

type

rating
(A)

catalogue
number

width
in mod.
of 9 mm

10
16
20
25
32
40
50
63
80
100
125

18482
18483
18484
18485
18486
18487
18488
18489
18490
18491
18492

3
3
3
3
3
3
3
3
3
3
3

10
16
20
25
32
40
50
63
80
100
125

18493
18494
18495
18496
18497
18498
18499
18500
18501
18502
18503

6
6
6
6
6
6
6
6
6
6
6

10
16
20
25
32
40
50
63
80
100
125

18504
18505
18506
18507
18508
18509
18510
18511
18512
18513
18514

9
9
9
9
9
9
9
9
9
9
9

10
16
20
25
32
40
50
63
80
100
125

18515
18516
18517
18518
18519
18520
18521
18522
18523
18524
18525

12
12
12
12
12
12
12
12
12
12
12

D curve C120H
1P
1

2
18482

2P
1 3

2 4
18500

3P
1 3 5

2 4 6
18514

4P
1 3 5 7

2 4 6 8
18525

additional
information
16

electrical auxiliaries: page 21


dimensions: page 31

Merlin Gerin

circuit protection

NC100L Miniature circuit-breakers


C curve
IEC 947-2: 25 kA
functions

The circuit-breakers combine the following


functions:
- protecting circuits against short-circuit
currents,
- protecting circuits against overload
currents,
- control,

- disconnection,
- protecting persons against indirect contact
in the TN and IT earthing systems
The NC100L circuit-breakers are used in the
tertiary sector and industry.

description

common technical data


c power circuit:
v voltage rating: 415 V AC
v ratings: 10 to 63 A set at 40 C
v breaking capacity:
- as in BS 3871 Pt1:

c environment:
v tropicalisation: treatment 2 (relative
humidity 95 % at 55 C)
v weight (g):

rating
(A)

v connection: tunnel terminals for 25 mm2


flexible cables or 35 mm2 rigid cables
v identification: each device comes with a
label holder on the toggle
v installation: in Multi 9 or Prisma enclosures

type

voltage
(V)

type

break. cap.
(kA)

1040 1P
2P, 3P, 4P

240
415

16
16

5063 1P
2P, 3P, 4P

240
415

10
10

- as in IEC 947-2, Icu ultimate breaking


capacity and BS 4752 ( O-CO cycle):
rating
(A)

type

1063 1P

2P, 3P, 4P

voltage
(V)

break. cap.
Icu (kA)

130
220240
400415
220240
380415

50
25
6
50
25

1P
180

2P
360

3P
540

4P
720

C curve
use
cables supplying standard loads
technical data
c power circuit:
v tripping curve:
the magnetic releases operate between 7
and 10 In.

v fast closing: allows increased withstand of


the high inrush currents of some loads
v disconnection with positive contact
indication: pole opening is indicated by the
mechanical indicator (green) on the front
face of the device. This indicator shows that
all the poles are open.
v number of operating cycles (O-C): 20 000

catalogue numbers

type

rating
(A)

catalogue
number

width
in mod.
of 9 mm

10
16
20
25
32
40
50
63

27621
27622
27623
27624
27625
27626
27627
27628

3
3
3
3
3
3
3
3

10
16
20
25
32
40
50
63

27632
27633
27634
27635
27636
27637
27638
27639

6
6
6
6
6
6
6
6

NC100L C curve
1P

27628

2P

1 3

2 4

27639

Merlin Gerin

17

circuit protection

NC100L Miniature circuit-breakers


C curve
IEC 947-2: 25 kA
catalogue numbers

type

rating
(A)

catalogue.
number

width
in mod.
of 9 mm

10
16
20
25
32
40
50
63

27643
27644
27645
27646
27647
27648
27649
27650

9
9
9
9
9
9
9
9

10
16
20
25
32
40
50
63

27654
27655
27656
27657
27658
27659
27660
27661

12
12
12
12
12
12
12
12

NC100L C curve (continued)


3P

1 3 5

2 4 6

27650
4P

1 3 5 7

2 4 6 8

27661

additional information

18

electrical auxiliaries: page 22


dimensions: page 31

Merlin Gerin

circuit protection

NC100LH Miniature circuit-breakers


C curve
IEC 947-2: 50 kA
functions

The circuit-breakers combine the following


functions:
- protecting circuits against short-circuit
currents,
- protecting circuits against overload
currents,
- control,

- disconnection,
- protecting persons against indirect contact
in the TN and IT earthing systems.
The NC100LH circuit-breakers are used in
the tertiary sector and industry.

description

common technical data


c power circuit:
v voltage rating: 415 V AC
v ratings: 10 to 63 A set at 40 C
v breaking capacity as in IEC 947-2, Icu
ultimate breaking capacity and BS 4752 (OCO cycle):

c environment:
v tropicalisation: treatment 2 (relative
humidity 95 % at 55 C)
v weight (g):

rating
(A)

type

1063 1P

voltage
(V)

break. cap.
Icu (kA)

220230
240
400
415

50
40
12,5
10 (1)

2P, 3P, 4P

220230 100
400
50
415
40
440
30
(1) 1 pole breaking capacity in the IT unearthed
neutral system (double fault)

type

1P
180

2P
360

3P
540

4P
720

v connection: tunnel terminals for 25 mm2


flexible cables or 35 mm2 rigid cables
v identification: each device comes with a
label holder on the toggle
v installation: in Multi 9 or Prisma enclosures

C curve
use
cables supplying standard loads
technical data
c power circuit:
v tripping curve:
the magnetic releases operate between 7
and 10 In.

v fast closing: allows increased withstand of


the high inrush currents of some loads
v disconnection with positive contact
indication: pole opening is indicated by the
mechanical indicator (green) on the front
face of the device. This indicator shows that
all the poles are open.
v number of operating cycles (O-C): 20 000

catalogue numbers

type

rating
(A)

cat. no.

width
in mod.
of 9 mm

10
16
20
25
32
40
50
63

27509
27510
27511
27512
27513
27514
27515
27516

3
3
3
3
3
3
3
3

10
16
20
25
32
40
50
63

27520
27521
27522
27523
27524
27525
27526
27527

6
6
6
6
6
6
6
6

NC100LH C curve
1P
1

27516
2P

1 3

2 4

27527

Merlin Gerin

19

circuit protection

NC100LH Miniature circuit-breakers


C curve
IEC 947-2: 50 kA
catalogue numbers

type

rating
(A)

catalogue
number

width
in mod.
of 9 mm

10
16
20
25
32
40
50
63

27531
27532
27533
27534
27535
27536
27537
27538

9
9
9
9
9
9
9
9

10
16
20
25
32
40
50
63

27542
27543
27544
27545
27546
27547
27548
27549

12
12
12
12
12
12
12
12

NC100LH C curve (continued)


3P
1 3 5

2 4 6

27538
4P
1 3 5 7

2 4 6 8

27549

additional information

20

electrical auxiliaries: page 22


dimensions: page 31

Merlin Gerin

circuit protection

electrical auxiliaries
for C60, C120
Applications

C60 auxiliaries enable remote tripping or


remote indication of the ON/OFF positions of
an mcb.
They are mounted by clipping on the left
hand side of the mcb/rcd.
In addition to the above Vigi module can
always be assembled on the right hand side
of an mcb.

Remote Tripping
OF
auxiliary
contact

SD alarm
switch

<

MX + OF
shunt trip

MN
undervoltage
release

max. 54 mm

mcb

>

MX + OF shunt trip release


type

width in
mod.
of 9 mm

voltage

cat. No.

c MX + OF shunt trip release:


v enables the mcb to be tripped from a
remote location,
v allows remote indication of the OFF or
ON position of the mcb by using the same
voltage as the one feeding the shunt rip
(terminals 12 and 14),
v is equipped with a cut-off switch in series
with the coil,
v all shunt trip release devices are equipped
with a red flag trip indicator;

MX + OF 2
220-415 V AC
110-130 V DC
48-130 V DC
48V AC
24 V AC and V DC
26946

MX + OF shunt trip release

26946
26947
26948

MX + OF
type

width in
mod.
of 9 mm

instantaneous
MN
2
time delayed 0.5 s
MN
4

voltage

cat. No.

24 V AC and V DC
48 V AC
48 V DC

26948
26961
26962

220-240 V AC

26963

c MN undervoltage release
v enables miniature circuit breakers to be
tripped either when the voltage drops or by
operation of the OFF push button of a
remote device tripping between 70 and
35% Un, closing 85% Un,
v prevents the mcb from being switched
ON again if the undervoltage release
supply is not present,
c MN s undervoltage release, time
delayed:
v allows micro breaks 200 ms without
effects,
v all under voltage release are equipped
with a red flag indicator.

Comsumption of releases
type
MX

26946

MN
SD alarm switch

MN

type

width in
mod.
of 9 mm

cat. No.

SD

26927

width in
mod.
of 9 mm

cat. No.

26924

26927

SD
OF auxiliary switch

type

OF

MN s

voltage
(V AC or V DC)
415V AC
200-240 V AC
110-130 V AC
110-130 V DC
48 V AC or V DC
24 V AC or V DC
220-240 V AC
48 V AC
48 V DC
220-240 V AC

pickup
pickup
pickup
pickup
pickup
pickup
hold
hold
hold
hold

(W or VA)
120
50
200
10
22
120
4.1
4.3
2.0
4.1

Remote indication
c SD alarm switch
An indicating device which monitors the
tripping of an mcb.
This device offers the following:
v a red flag trip indicator,
v ability to reset without closing the mcb,
v test function;
c OF auxiliary switch
v a changeover switch which acts as an
indicating or control device to monitor the
ON or OFF positions of an mcb;
v ability to reset without closing the mcb,
c breaking capacity of auxiliary contacts.
voltage
(V AC or V DC)
415 V AC
240 V AC
130 V DC
48 V DC
24 V DC

breaking capacity
(A)
3
6
1
2
6

c connection: screw clamp terminal for 1


cable 2.5mm2 (or 2 x 1.5mm2)
14 12 11

26924

Merlin Gerin

OF

21

circuit protection

electrical auxiliaries
for NC100
functions

Remote tripping and indication


of NC100 circuit-breakers.

description

auxiliary combinations

+
SD fault
indicating
switch

- Mounted to the left of the circuit-breaker


(SD and OF).
- Mounted to the right of the circuit-breaker
(MX + OF and MN).

+
Circuit-breaker

OF
auxiliary
contact

or
MX + OF
shunt trip
release

MN
undervoltage
release

remote tripping

remote indication

By means of an MX shunt trip or MN


undervoltage release.

OF contact
c this auxiliary contact installed to the left of
the circuit-breaker indicates the open or
closed position of the circuit-breaker.
SD fault indicating switch
c this auxiliary switch installed to the left of
the circuit-breaker indicates the tripped on
fault position of the circuit-breaker.
c visualisation of the fault on the front panel
by mechanical indicator lamp.

MX + OF shunt trip release


When energised, trips and opens the circuitbreaker with which it is associated:
c fitted with a cut-off contact
c fitted with an O + F contact that indicates
the open or closed position of the
circuit-breaker.
MN undervoltage release
When its supply voltage drops (between 70
and 35%) it trips and opens the circuitbreaker with which it is associated, and
prevents reclosing of this circuit-breaker until
its supply voltage is restored:
c complies with IEC 947-2 and IEC 157-1
standards
c use:
v emergency stop via push button
v safety feature on circuit supplying several
machines preventing uncontrolled
restarting of the motors.

technical data
c breaking capacity of the auxiliary switches
voltage
(V AC or DC)

breaking capacity
(A)

415 V
240 V
130 V
48 V
24 V

AC
AC
DC
DC
DC

3
6
1
2
6

technical data common to the auxiliaries


c connection: terminal pads for two 1.5 mm2
cables or one 2.5 mm2 cable.

MN s time-delayed undervoltage release


Undervoltage release controlling opening of
the circuit-breaker with which it is
associated. Allows a 0.5 second time delay
on a short supply interruption or voltage
drop.
technical data
c consumption of releases
type

22

voltage
(V CA or V CC)

(W or VA)

MX

AC
DC

pick-up 240
pick-up 200

MN

AC
DC

holding 4,1
holding 4,1

MN s

AC
DC

holding 4,1
holding 4,1

Merlin Gerin

circuit protection

electrical auxiliaries
for NC100
catalogue numbers

type

control voltage
(V AC)
(V DC)

catalogue
number

width
in mod.
of 9 mm

MX + OF shunt trip release

C2 C1

12

27136

220415
110220
2448

110125
2448

27136
27137
27138

2
2
2

220240

220240

27140

220240

220240

27143

27132

27135

14

MN undervoltage release
instantaneous
D1 D2
u<

time-delayed s
27140

D1 D2
u<

OF auxiliary contact

11

12

27132

14

SD fault indicating switch

91

92

94

27135

additional information

Merlin Gerin

dimensions: page 31

23

residual current protection

instantaneous RCCB/ELCB, selective RCCB/ELCB


30 mA to 300 mA instantaneous
300 mA s selective

protected against nuisance tripping

functions

The residual current circuit breakers


combine the following functions:
- control
- automatic breaking of a circuit if an
insulation fault occurs between the phase

and earth that is greater than or equal to


10,30,300 mA.
The residual current circuit breakers are
used in the residential, tertiary and industrial
sectors.

description

The residual current release is an


electromechanical device operating without
any auxiliary source of supply.

c environment:
v tropicalisation: treatment 2 (relative
humidity 95% at 55 C)
v weight (g)

common technical data


c in the presence of devices containing
rectifying units (diodes, thyristors, triacs),
use an A class instantaneous residual
current circuit breaker guaranteeing tripping
in the presence of a dc component .
c provides protection against nuisance
tripping due to transient overvoltages
(lightning, switchgear switching on the
network, etc.).
Level of immunity: 250A peak as in 8/20 ms
periodical wave
c power circuit:
v operational voltage:
- 240 415 V AC, +10, -20 %, 50 Hz
v operational current: up to 100 A
v disconnection with positive contact
indication
v increased short-circuit current withstand
v number of operating cycles (O-C): 20 000
c release:
v instantaneous or selective release: fixed
sensitivities for all ratings
c manual operating mechanism: handle
c indication:
v mechanical: the residual current fault is
shown on the front face by a mechanical
indicator
v electrical: by the SD indication auxiliary

catalogue numbers

type

voltage
(V AC)

rating
(A)

sensitivity
(mA)

type

2P
230

4P
450

v connection
- tunnel terminals for 35 mm2 flexible cables
or 50 mm2 for rigid cables
c complies with the standards: IEC 1008
and EN 61-008. Rccb 2P 4080 A and 4 P
4063 A are approved by SIRIM.

instantaneous RCCB/ELCB
technical data
c instantaneous release

selective RCCB/ELCB s

technical data
v selective release allowing total vertical
discrimination where the 30 mA residual
current devices are placed downstream.

catalogue
number

width
in mod.
of 9 mm

16204
16205
16206
16208
16209
16210
16246
16212
16213
16214
16216
16217
16218
16248

4
4
4
4
4
4
4
4
4
4
4
4
4
4

ID residual current switches AC class


2P

240

40

63

T
R

80
N

100
16206

24

30
100
300
30
100
300
300s
30
100
300
30
100
300
300s

Merlin Gerin

residual current protection

instantaneous RCCB/ELCB, selective RCCB/ELCB


30 mA to 300 mA instantaneous
300 mA s selective
catalogue numbers

type

voltage
(V AC)

rating
(A)

sensitivity
(mA)

catalogue
number

width
in mod.
of 9 mm

RCCB/ELCB residual current circuit breakers AC class (continued)


4P

415

40

63

T
R

80

30
100
300
30
100
300
300s
30
300
300s

16254
16255
16256
16258
16259
16260
16265
16261
16263
16266

8
8
8
8
8
8
8
8
8
8

16260

additional information

Merlin Gerin

electrical auxiliaries: page 26


dimensions: page 31

25

residual current protection

electrical auxiliaries
for RCCB/ELCB
functions

These electrical auxiliaries are used for


remote indication or tripping of the residual
current circuit breakers.

description

auxiliary combinations

They are mounted on the lefthand side of


the residual current circuit breaker within a
54 mm width.

+
max. 54 mm

<

OF auxiliary switch
SD fault indicating
switch

MX shunt trip release


MN undervoltage release

>

OFS
auxiliary
switch

residual current
circuit breaker

remote tripping

remote indication

A MX or MN release can be used for this


purpose.
Tripping is shown by a red indicator on the
front face.

OFS switch
c use of the OFS switch is compulsory for
adding the MN, MX, SD and OF functions.
c fixed on the lefthand side of the residual
current switch, it indicates whether the
switch is open or closed.
OF switch
c fixed on the lefthand side of the residual
current switch, it indicates whether the
switch is open or closed.
SD fault indicating switch
c this auxiliary switch installed to the left of
the circuit-breaker indicates the tripped on
fault position of the circuit-breaker.
c visualisation of the fault on the front panel
by mechanical indicator lamp.

MX + OF shunt trip release


trips and opens its associated circuit-breaker
when energised:
c equipped with a self-breaking switch
c equipped with a switch (terminals 12 and
14) to indicate whether the circuit-breaker is
opened or closed when the coil is
energised.
MN undervoltage release
trips and opens its associated circuit-breaker
when the supply voltage drops (between 70
and 35%) and prevents reclosing until the
supply voltage is restored:
c complies with standards IEC 947-2
c use:
v push button emergency stop
v safety on the supply circuits of several
machines by disabling uncontrolled restart
of all motors.
MN time delayed undervoltage release s
This undervoltage release controls the
opening of its associated residual current
switch. It allows a 0.5 second time delay on
short supply interruptions or voltage drops

type

MX

MN

MNs

voltage
(V AC or DC)

(W or VA)

415 V
AC
220...240 V AC
110...130 V AC
DC
48 V
AC
DC
24 V
AC
DC
220...240 V AC
48 V
AC
DC
220...240 V AC

inrush
inrush
inrush
inrush
inrush
inrush
inrush
inrush
hold
hold
hold
hold

characteristics
c breaking capacity of the auxiliary switches
voltage
(V AC or DC)

breaking capacity
(A)

415 V
240 V
130 V
48 V
24 V

AC
AC
DC
DC
DC

3
6
1
2
6

common auxiliary characteristics


c connection by pad terminals for 2 cables
1.5 mm2 or 1 cable 2.5 mm2.
operation simulation
A test button on the front face of the OF
switches is used to simulate the OF
functions without using the residual current
circuit breaker.

characteristics
c consumption of releases

26

120
50
200
10
22
22
120
120
4.1
4.3
2,0
4.1

Merlin Gerin

residual current protection

electrical auxiliaries
for RCCB/ELCB
catalogue numbers

type

control voltage
(V AC)
(V DC)

catalogue
number

width
in mod.
of 9 mm

110...130
48
24

26946
26947
26948

2
2
2

48

26960
26961
26962

2
2
2

26963

26923

26927

26924

MX + OF shunt trip release


220...415
48...130
24

MN undervoltage release
26946

instantaneous

time delayed s

26960

220...240
48

220...240

OFS auxiliary switch

14 12 11

26923

SD fault indicating switch

92 94 91

26927

OF auxiliary switch

14 12 11

26924

additional information

Merlin Gerin

dimensions: page 31

27

additional information

discrimination

upstream: C60a, N, H, L, C Curve


downstream: C60a, N, H, L
upstream
downstream
C60a, N, H, L
C curve

28

In (A)
discrimination
limit rating Ir (A)

(A)
1
2
3
4
6
10
16
20
25
32

C60a, N, H, L
C curve
2
3
15
23

4
30

6
45

10
75

16
120

20
150

25
188

32
240

40
300

50
375

63
473

Merlin Gerin

additional information

discrimination

upstream: Merlin Gerin multi 9


downstream: Merlin Gerin multi 9
upstream
downstream
In (A)
rating Ir
C60a
curve C

C60N
curve C

C120N/H
curve C
NC100L

NC100LH
curve C

10
16
20
25
32
40
10
16
20
25
32
40
50
63
63
80
100
16
20
25
32
40
50
63
16
20
25
32
40
50
63

NS100N/H/L
Trip unit TM-D
16
25

NS160N/H/L
trip unit TM-D
80
100

32

40

50

63

80

100

0.5
0.5
0.5
0.5
0.5
0.5
0.5
0.5
0.5
0.5
0.5
0.5

0.63
0.63
0.63
0.63
0.63
0.63
0.63
0.63
0.63
0.63
0.63
0.63
0.63

0.8
0.8
0.8
0.8
0.8
0.8
0.8
0.8
0.8
0.8
0.8
0.8
0.8
0.8

T
T
T
T
T
T
T
T
T
T
T
T
T

0.8
0.8
0.8
0.8
0.8
0.8
0.8
0.8
0.8
0.8
0.8
0.8
0.8
0.8

T
T
T
T
T
T

0.19

0.3
0.3

0.4
0.4
0.4

0.5
0.5
0.5
0.5

0.5
0.5
0.5
0.5

0.19

0.3
0.3

0.4
0.4
0.4

0.5
0.5
0.5
0.5

0.5
0.5
0.5
0.5

0.4
0.4

0.5
0.5

0.5
0.5
0.5

0.5
0.5
0.5
0.5
0.5

0.63
0.63
0.63
0.63
0.63
0.63

0.4
0.4

0.5
0.5

0.5
0.5
0.5

0.5
0.5
0.5
0.5

0.63
0.63
0.63
0.63
0.63
0.63

T
T
T
T
T
T

125

160

T
T
T
T
T
T
T
T
T
T
T
T
T
T
2.5

T
T
T
T
T
T
T
T
T
T
T
T
T
T
2.5

T
T
T
T
T
T
T
T
T
T
T
T
T
T

T
T
T
T
T
T
T
T
T
T
T
T
T
T

T
T
T
T
T
T
T
T
T
T
T
T
T
T
2.5
2.5
2.5
T
T
T
T
T
T
T
T
T
T
T
T
T
T

Using the tables


Two circuit breakers offer total discrimination when the corresponding box in the discrimination table is
shaded or contains the letter T.
When discrimination is partial for the combination, the corresponding box indicates the maximum value of
the fault current for which discrimination is provided. For fault currents above this value, the two circuit
breakers trip simultaneously.

Merlin Gerin

29

additional information

cascading
230/240 V network
upstream: Merlin Gerin multi 9
downstream: Merlin Gerin multi 9
upstream cb
rated breaking capacity kA rms

C60a
10

C60N
20

downstream cb
C60a
C60N

rated breaking capacity


20

C60H
30

C60H
20

C120N
30

NC100L
50

NC100LH
100

30
30

20

30
30

50
50

100
100

upstream: Merlin Gerin Compact


downstream: Merlin Gerin multi 9
upstream cb
rated breaking capacity kA rms

NS100N
85

NS100H
100

NS100L
150

downstream cb
C60a
C60N
C120N
C120H

rated breaking capacity


30
80
80
40
100
100
40
50
70
40
50
70

NS160N
85

NS160H
100

NS160L
150

NS250N
85

NS250H
100

NS250L
100

30
40
40
40

40
60
50
50

40
60
70
70

30
40
40
40

40
60
50
50

40
60
70
70

cascading
400/415 V network
upstream: Merlin Gerin multi 9
downstream: Merlin Gerin multi 9
upstream cb
rated breaking capacity kA rms

C60N
10

C60H
15

downstream cb
C60a
C60N

rated breaking capacity


10
15
15

C60H
10

C120N
15

NC100L
25

NC100LH
50

10

15
15

25
25

50
50

upstream: Merlin Gerin Compact


downstream: Merlin Gerin multi 9
upstream cb
rated breaking capacity kA rms

NS100N
36

downstream cb
C60a
C60N
C120N
C120H

rated breaking capacity


15
20
20
25
30
30
25
25
25
25
25
25

30

NS100H
70

NS100L
150

NS160N
36

NS160H
70

NS160L
150

NS250N
36

NS250H
70

NS250L
150

15
25
25
25

20
30
25
25

20
30
25
25

15
25
25
25

20
30
25
25

20
30
25
25

Merlin Gerin

dimensions
multi 9
C60

C120

circuit breakers

circuit breakers
4P
3P+N

4P
3P+N
3P

3P

2P
1P+N

2P
1P

1P

Auxiliaries for C60, C120, ID/RCCB

OF, SD, OF+SD/OF

OF, SD, OF+SD/OF

MX, MN, MN S , MSU

MX+OF, MNx

MX, MN, MN S , MSU,


MX+OF, MNx

NC100
circuit breakers

Auxiliaries

4P
3P
2P
1P

RCCB

Merlin Gerin

Auxiliaries

31

MULTI 9 Consumer Unit


Mini Pragma Din-Kit Semi-equipped Consumer Unit
Mini Pragma Din-Kit Semi-equipped Consumer Unit comprising :- one enclosure
- one incoming fuse-switch / circuit breaker / isolator
- one earth leakage circuit breaker
ONE complete consumer unit = ONE Mini Pragma Din-Kit plus
Outgoing Domae MCBs
Ease of selection
Robust design for all building requirements
Resistant to impacts, scratches, humidity as it is made of insulating,
self-extinguishing material
(compliant to IEC 529 : IP40 and IEC 695-2-1 casing : 650C / 30s)

Available Ways for


Outgoing Domae 1P MCBs

Number of Ways
(Enclosure)

Din-Kit
Reference

Incoming
Rating

12

DK12FS33E410

32

12-way Mini Pragma Enclosure X1


SFT 32A 1P+N Fuse Switch
X1
Domae ELCB 40A 2P 100mA X1

12

DK12MA42E410

40

12-way Mini Pragma Enclosure X1


Domae 1P+N 40A MCB 4.5kA X1
Domae ELCB 40A 2P 100mA X1

12

DK12IS62E410

40

12-way Mini Pragma Enclosure X1


Isolator 2P 63A
X1
Domae ELCB 40A 2P 100mA X1

12

DK12MA62E610

63

12-way Mini Pragma Enclosure X1


Domae 1P+N 63A MCB 4.5kA X1
Domae ELCB 63A 2P 100mA X1

12

DK12IS62E610

63

12-way Mini Pragma Enclosure X1


Isolator 2P 63A
X1
Domae ELCB 63A 2P 100mA X1

18

DK18FS33E410

32

18-way Mini Pragma Enclosure X1


SFT 32A 1P+N Fuse Switch
X1
Domae ELCB 40A 2P 100mA X1

15

18

DK18MA42E410

40

18-way Mini Pragma Enclosure X1


2P 40A MCB 4.5kA
X1
Domae ELCB 40A 2P 100mA X1

14

18

DK18IS62E410

40

18-way Mini Pragma Enclosure X1


Isolator 2P 63A
X1
Domae ELCB 40A 2P 100mA X1

14

18

DK18MA62E610

63

18-way Mini Pragma Enclosure X1


Domae 1P+N 63A MCB 4.5kA X1
Domae ELCB 63A 2P 100mA X1

14

18

DK18IS62E610

63

18-way Mini Pragma Enclosure X1


Isolator 2P 63A
X1
Domae ELCB 63A 2P 100mA X1

14

24

DK24MA62E610

63

24-way Mini Pragma Enclosure X1


Domae 1P+N 63A MCB 4.5kA X1
Domae ELCB 63A 2P 100mA X1

20

24

DK24IS62E610

63

24-way Mini Pragma Enclosure X1


Isolator 2P 63A
X1
Domae ELCB 63A 2P 100mA X1

20

Contents

Note : For other combination, please consult us.


32

Merlin Gerin

Merlin Gerin

Mini

Pragma
Din Kit

Semi equipped
consumer unit

Take full advantage of Merlin Gerin's experience


and know-how.
Discover Mini Pragma Din Kit a new range
of semi equipped consumer units comprising, in
a single catalogue number, of:
one enclosure (12 / 18 / 24 / 36-way)
one incoming circuit-breaker or isolator
one earth leakage circuit breaker
You can expect:

ease of selection

a robust design for all building requirements

resistant to impacts, scratches, humidity
as it is made of insulating, self-extinguishing
material (compliant to IEC 529:IP40 and IEC
695-2-1 casing: 650C / 30s)

surface mounted with a sealable front face
Merlin Gerin Mini Pragma Din Kit, an offer for
everyday comfort!

Schneider Electric Industries (M) Sdn Bhd (378576-M)


Shah Alam (HQ)
No. 11, Jalan U1/19, Seksyen U1,
Hicom-Glenmarie Industrial Park,
Shah Alam 40150, Selangor,
Malaysia
Tel
: (603) 7883 6333
Fax
: (603) 7883 6188
Customer Care: 1-800-880-877
Email : care@my.schneider-electric.com
Website : www.schneider-electric.com.my

SEIMC60C04

Johor Bahru Branch


Tel : (607) 351 3801
Fax : (607) 351 4113

Kota Kinabalu Branch


Tel : (6088) 237 012
Fax : (6088) 216 900

Ipoh Branch
Tel : (605) 527 1375
Fax : (605) 527 1375

Kuching Branch
Tel : (6082) 368 428
Fax : (6082) 361 855

Prai Branch
Tel : (604) 398 3981 / 2
Fax : (604) 398 3984

Services Hotline
Tel : (603) 7883 6238 (24 Hrs)

As standards, specifications and designs change from time to time, please


ask for confirmation of the information given in this publication.

Design, production, illustrations: Schneider Electric Industries (M) Sdn Bhd


Printed in Malaysia