Content: For CS domain services, when Ec/No is used as the measurement quantity for inter-RAT measurement, the
RNC sends the signaling to deactivate compressed mode and stop inter-RAT measurement, if the UE reports the
event 2F when the measured value is larger than the value of this parameter.
Recommended value (default value): -12
- INTERRATCSTHD2DRSCP
Threshold to trigger inter-RAT measurement with measurement quantity of RSCP for CS domain services
Value range: -115~-25
Physical unit: dBm
Content: For CS domain services, when RSCP is used as the measurement quantity for inter-RAT measurement, the
RNC sends the signaling to activate compressed mode and start inter-RAT measurement, if the UE reports the event
2D when the measured value is smaller than the value of this parameter.
Recommended value (default value): -100
- INTERRATCSTHD2FRSCP
Threshold to stop inter-RAT measurement with measurement quantity of RSCP for CS domain services
Value range: -115~-25
Physical unit: dBm
Content: For CS domain services, when RSCP is used as the measurement quantity for inter-RAT measurement, the
RNC sends the signaling to deactivate compressed mode and stop inter-RAT measurement, if the UE reports the
event 2F when the measured value is larger than the value of this parameter.
Recommended value (default value): -97
- INTERRATHTHD2DECN0
Threshold to trigger inter-RAT measurement with measurement quantity of Ec/No for PS domain HSPA services
Value range: -24~0
Physical unit: dB
Content: For PS domain HSPA services, when Ec/No is used as the measurement quantity for inter-RAT
measurement, the RNC sends the signaling to activate compressed mode and start inter-RAT measurement, if the
UE reports the event 2D when the measured value is smaller than the value of this parameter.
Recommended value (default value): -15
- INTERRATR99PSTHD2DECN0
Threshold to trigger inter-RAT measurement with measurement quantity of Ec/No for PS domain R99 services
Value range: -24~0
Physical unit: dB
Content: For PS domain R99 services, when Ec/No is used as the measurement quantity for inter-RAT
measurement, the RNC sends the signaling to activate compressed mode and start inter-RAT measurement, if the
UE reports the event 2D when the measured value is smaller than the value of this parameter.
Recommended value (default value): -15
- INTERRATHTHD2FECN0
Threshold to stop inter-RAT measurement with measurement quantity of Ec/No for PS domain HSPA services
Value range: -24~0
Physical unit: dB
Content: For PS domain HSPA services, when Ec/No is used as the measurement quantity for inter-RAT
measurement, the RNC sends the signaling to deactivate compressed mode and stop inter-RAT measurement, if the
UE reports the event 2F when the measured value is larger than the value of this parameter.
Recommended value (default value): -13
- INTERRATR99PSTHD2FECN0
Threshold to stop inter-RAT measurement with measurement quantity of Ec/No for PS domain R99 services
Value range: -24~0
Physical unit: dB
Content: For PS domain R99 services, when Ec/No is used as the measurement quantity for inter-RAT
measurement, the RNC sends the signaling to deactivate compressed mode and stop inter-RAT measurement, if the
UE reports the event 2F when the measured value is larger than the value of this parameter.
Recommended value (default value): -13
- INTERRATHTHD2DRSCP
Threshold to trigger inter-RAT measurement with measurement quantity of RSCP for PS domain HSPA services
Value range: -115~-25
Physical unit: dBm
Content: For PS domain HSPA services, when RSCP is used as the measurement quantity for inter-RAT
measurement, the RNC sends the signaling to activate compressed mode and start inter-RAT measurement, if the
UE reports the event 2D when the measured value is smaller than the value of this parameter.
Recommended value (default value): -110
- INTERRATR99PSTHD2DRSCP
Threshold to trigger inter-RAT measurement with measurement quantity of RSCP for PS domain R99 services
Value range: -115~-25
Physical unit: dBm
Content: For PS domain R99 services, when RSCP is used as the measurement quantity for inter-RAT measurement,
the RNC sends the signaling to activate compressed mode and start inter-RAT measurement, if the UE reports the
event 2D when the measured value is smaller than the value of this parameter.
Recommended value (default value): -110
- INTERRATHTHD2FRSCP
Threshold to stop inter-RAT measurement with measurement quantity of RSCP for PS domain HSPA services
Value range: -115~-25
Physical unit: dBm
Content: For PS domain HSPA services, when RSCP is used as the measurement quantity for inter-RAT
measurement, the RNC sends the signaling to deactivate compressed mode and stop inter-RAT measurement, if the
UE reports the event 2F when the measured value is larger than the value of this parameter.
Recommended value (default value): -107
- INTERRATR99PSTHD2FRSCP
Threshold to stop inter-RAT measurement with measurement quantity of RSCP for PS domain R99 services
Value range: -115~-25
Physical unit: dBm
Content: For PS domain R99 services, when RSCP is used as the measurement quantity for inter-RAT measurement,
the RNC sends the signaling to deactivate compressed mode and stop inter-RAT measurement, if the UE reports the
event 2F when the measured value is larger than the value of this parameter.
Recommended value (default value): -107