You are on page 1of 1

GENERAL NOTES

26

25

23

24

22

21

20

19

18

17 16

15

13

14

12 11 10

ALL DIMENSIONS ARE IN mm.

HOIST NO.3 STARTS FROM LEVEL 05.

A40-02

13386

8355

6695

3125

4675

2375

5575

7650

5400

3909

3809

4568

6157

750

7475
325

1359

4844

2988

2493

5479

3778

4750

ALL DATES ARE ACCORDING TO APPROVED SPLL PLANNING


FORCAST (R2).

5200

756

3400

56

B
2550

58
50

ELEVATOR ITEMS (roofed structure)


(20m x 6m)

5750

55

B.1

PROJECT

1500

11

80

B.9

6000

WALK

MULTI-PURPOSE ROOM

D.5

F1/SK-/C1

CLIENT
INDOCEAN DEVELOPERS (PVT) LIMITED

DESIGN ARCHITECT
SAFDIE ARCHITECTS, LLC.
100 PROPERZIE WAY
SOMERVILLE, MA 02143-3740 USA
T 617.629.2100 F 617.629.2406

shaft B

WH
WM
DB

59
00

shaft A
shaft C

DB

51

WET RISERS

4000

DW

WET RISERS

SAFE

WALK

ELEV A1
UP

PRES

DOOR

1675

DOOR

UP

WASTE
CHUTE

ELEV B1

PRES

PB2

EL. 16.800 m

WAY

2750

PB1

ELEV B3 ELEV B2
EL. 17.900 m

1784

2900

DOOR

ELEV A2 ELEV A3 ELEV A4

DOOR

00
59

EL. 16.800 m

2600

EL. 17.900 m

ELEV B4 ELEV B5 ELEV B6 ELEV B7

E
F

1675

A40-02

SAFE

52

59
00

DIAGRID STORE
(SEPT'15 - AUG'16)

COLOMBO RESIDENTIAL TOWER


COLOMBO, SRI LANKA

WAY

59
00

53

A2

shaft B
CABINET

3350

54

A3

ASSOCIATE ARCHITECT
DESIGN TEAM 3
SINGAPORE
T 658.499.7168
STRUCTURAL ENGINEER
MR. PREDRAG EROR
P.O. BOX 102803, DUBAI, UAE
T 9714.3629234 F 9174.3629234
MECH, ELECT, PLUMBING ENGINEER
CKR CONSULTING ENGINEERS PVT. LTD.
BUILDING NO - 4
GROUND FLOOR
MANJOLAI STREET, 1ST MAIN ROAD
EKKATTUTHANGAL, CHENNAI - 600 032
T. 91 (44) 435.11690

LPG

KED
300x450

DW

DW

WM
WH

WH
WM

WASTE
CHUTE
NT

REFERENCE NO

10000

PR

13

03

A2

L
2866

L.5

1514

3804

DIAGRID STORE
(SEPT'15 - AUG'16)

2252

DESCRIPTION

00
R1
R2
R3

DATE
11.08.14
30.09.14
25.11.14
01.08.15

ARRANGEMENT REVISED
ARRANGEMENT REVISED
ARRANGEMENT REVISED

M.5
KEY PLAN

3028

A1
DIAGRID STORE
( SEPT'15 - OCT'16)

N
5280

5650
5650

48

5650

47

5650

46
45

5650

44

5650

43

5650

42

5202

5650

A40-01

39
38

5650

37

MAIN ISOLATOR
(MCCB)

5650

36
DRY
POWDER

LEGEND
CO2

MCB FOR LIGHTING


& SOCKETS

35

LEVEL 05

34

DISTRIBUTION BOARD

5650

30

- DRINKING WATER

TIME PERIOD

- FIRE WATER

A1

STRUCTURAL STEEL - DIAGRIDS

(SEP'15 - OCT'16)

- CURING WATER

A2

STRUCTURAL STEEL - DIAGRIDS

(SEPT'15 - AUG'16)

- ELECTRICITY

A3

STRUCTURAL STEEL - DIAGRIDS

( JUL'15 - OCT'16)

20m x 6m

(JULY'15 - JUN'16)

- CONCRETE PIPE LINE


B

ELEVATOR ITEMS

L5 - PROPOSED LOGISTIC PLAN


Drawn
SS

31
SIZE

DRAWING TITLE

5650

32

STORE (L5)

ARCHITECTURAL

X3

5650

33

- FIRE EXTINGUISHER

- SEWER & WASTE LINE

(FLOOR MOUNTED)

DISCIPLINE

X4

5650

- DISTRIBUTION BOARD

FIRE EXTINGUISHERS

5650

- EXIT ROUTE

EXTERNAL SOCKETS
(INDUSTRIAL TYPE)

Sub Contractor

5650

PHASE INDICATORS

X2

5657

X1

5550

40

9754

3681

41

TRIP SWITCH(RCD)

Main Contractor

5280

5650

2850

49

ISSUE
NO.

Checked

Date
11.08.14

Date

Approved

Scale

Date

1:200
1:400

Drawing Number
ATR-SPLL-GN-DWG-0011

For Information Only

Status

SHOP DRAWING

Size
A1
A3
Rev.
03

You might also like