You are on page 1of 2

RELIABLE AIR CONDITIONING SYSTEMS FOR THE GLOBAL ROLLING STOCK MARKET

SALOON AIR CONDITIONING FOR METRO APPLICATIONS


Passenger safety and comfort is of paramount importance on high capacity metro networks
around the world. Sigma Coachairs metro saloon air conditioning systems have been
designed to operate in some of the most demanding high temperature and high humidity
environments such as Mass Transit Railway Corporation in Hong Kong, Delhi Metro Railway
Corporation in India and Taipei Metro in Taiwan.
These high capacity air conditioning systems come fully equipped with emergency
ventilation micro-processor control, high ambient unloading and integration with the train
management system.

RXR1003/4. Issue 2

AIR CONDITIONER
MODEL: RPR44MX1
Saloon Unit

SPECIFICATION DATA
Brief Description:
Key Dimensions:
Cooling Capacity:
Air Volume flow rates:
Power Consumption:
Temperature Information:

Emergency Ventilation:
Power Supply:
Number of compressors:
Mass:
Materials of manufacture:
Shock and vibration testing details:
Refrigerant:
EMC/EMI:

Roof mounted air conditioning unit.


Nominal (mm) 2310W x 3300L x 430H.
42kW.
2075 l/s.
21kW.
o
Open track: Ambient 32 C 75% RH
o
Tunnel: Ambient 35 C, 65% RH
Saloon: 25oC, 65% RH.
980 l/s.
3 phase / 400V AC / 50 Hz Control 110VDC.
One (1).
1005 kg.
Stainless steel construction.
RIA20:1995.
R134a.
ENV 50121-3-2.

For more information on the Sigma Coachair range of Air Conditioners, please contact our Head Office listed below.
In the interests of product improvement, Sigma Coachair, reserves the right to alter specifications without notice.

SIGMA COACHAIR GROUP


A LLOYDS QUALITY ACCREDITED COMPANY
HEAD OFFICE:
Web:
Email:
Phone:
Fax:

3 Distillers Place, Huntingwood NSW 2148 Australia


www.sigmacoachair.com
scg@sigmacoachair.com
+ 61 2 9830 7100
+ 61 2 9672 1018

RXR1003/4. Issue 2