Professional Documents
Culture Documents
Counter Flow
V h
(cm/min)
1,000
2,000
3,000
4,000
h ,
T
(C)
61
60
60
59
T h, mid
T h, out
(C)
(C)
52
54
54
55
44
48
49
49
c ,
T
(C)
25
26
26
26
T c, mid
T c, out
(C)
(C)
29
32
33
34
32
35
36
37
V h
(cm/min)
Power
Power
Power
Efficienc
Emitted
(W)
Absorbe
Lost (W)
y( )
d (W)
T1
T2
Tm
U
W/(m. C)
(C)
(C)
(C)
29
25
19
22
23.65
23.47
306.55
793.24
1,000
2,000
1169.60
1649.0
485.72
1247.26
683.88
401.82
(%)
41.53
75.63
3,000
8
2467.7
2078.14
189.58
91.64
24
23
23.50
1320.07
4,000
2
2747.5
2774.33
-26.8
100.97
22
23
22.50
1822.74
Parallel Flow
V h
h ,
T
(cm/min)
(C)
59
60
61
59
1,000
2,000
3,000
4,000
T h, mid
T h, out
(C)
(C)
49
52
55
53
44
47
50
49
c ,
T
(C)
26
26
25
25
T c, mid
T c, out
(C)
(C)
31
32
33
33
31
33
35
34
V h
Power
Power
Power
Efficienc
Emitted
(W)
Absorbe
Lost (W)
y( )
1,000
1033.1
346.70
686.48
(%)
33.56
2,000
8
1788.2
970.09
818.18
3,000
7
2266.6
2078.13
4,000
0
2750.2
2493.89
(cm/min)
T1
T2
Tm
U
W/(m. C)
(C)
(C)
(C)
28
18
22.63
228.66
54.25
27
26
26.49
546.44
188.14
91.68
26
25
25.49
1216.50
256.35
90.68
25
24
24.50
1521.31
d (W)
SAMPLE CALCULATION
Note:
This sample calculation of parallel flow and counter flow is based on the data
taken at 1000 cm/min cold water and 1000 cm/min hot water volume flow
rate.
Parallel Flow
By referring to the table of saturated water properties (Table A-9):
At
T h, mid = 49
By doing interpolation:
At T= 50
At T= 45
h = 988.5 kg/m
Cph = 4.1808 kJ/kg.K
At
T c, mid
= 31
By doing interpolation:
At
At
c
(35 31) / (35 30) = (994 -
) / (994 996)
= 995.6 kg/m
c
= 995.6 kg/m
Cpc = 4.1780 kJ/kg.K
V h
Power Emitted =
C ph
h ,
T
= (1000 x 1/60 x 1/ 10
T h, out )
= 1033.18 W
Power Absorbed =
V c
C pc ( T c, out
6
= (1000 x 1/60 x 1/ 10
c ,
T )
= 346.48 W
Power lost = Power Emitted - Power Absorbed
= 1033.18 346.48
= 686.48 W
The overall efficiency () is:
= (Power Absorbed/Power Emitted) x 100
= (346.70 / 1033.18) x 100
= 33.56 %
T1 = (
T m ) is:
T1
T m = ( T 1 - T 2 ) / ln(
)
T2
h ,
T c, out )
T
= (59 - 31)
= 28 C
T2
=(
T h, out -
c ,
T )
= (44 26)
= 18 C
T1
T
T
T
ln(
)
m
1
2
= (
-
)/
T2
= (28 18) / ln (28/18)
= 22.63 C
U = Power Absorbed /
As T m
U = 346.70 / (0.067/22.63)
= 228.66 W/m. C
Counter Flow
By referring to the table of saturated water properties (Table A-9):
At
T h, mid = 52
h = 986.94 kg/m
Cph = 4.1818 kJ/kg.K
At
T c, mid = 29
By doing interpolation:
c
= 996.2 kg/m
Cpc = 4.1784 kJ/kg.K
Power Emitted =
V h
C ph
h ,
T
T h, out )
= (1000 x 1/60 x 1/ 10
= 1169.60 W
Power Absorbed =
V c
C pc ( T c, out
6
= (1000 x 1/60 x 1/ 10
c ,
T )
= 485.72 W
Power lost = Power Emitted -Power Absorbed
= 1169.60 - 485.72
= 683.88 W
T m ) is:
T1
T
T
T
ln(
)
m
1
2
= (
-
)/
T2
T1 = (
h ,
T c, out )
T
= (61 32)
= 29 C
T2
=(
T h, out -
= (44 - 25)
= 19 C
c ,
T )
T1
T
T
T
ln(
)
m
1
2
= (
-
)/
T2
= (29 - 19) / ln (29/19)
= 23.65 C
U = Power Absorbed /
U = 485.72 / (0.067/23.65)
= 306.55 W/m. C
As T m