LED Display Installation Instruction Manual (s08-018) PDF
LED Display Installation Instruction Manual (s08-018) PDF
DMX Technologies
www.dmxtec.com
Table of Contents
Preface
1. Safety precaution
2. Installation screen
2.1 LED Module dimension
2.2 Cabinet structure
2.3 Data cabling diagram
2.4 Power cabling diagram
2.5 Installations selection
2.6 Installing cabinets to frame work
3. Hardware/software installation and setup
3.1 Graphic Card and Data Sending Card Installation
3.2 Hardware Connection
3.3 Computer configuration
3.4 Software setup
3.5 Calibration
3.6 Software Instruction Manual
4. Spare Parts replacing and maintenance
4.1Spare Parts replacing
4.1.1 LED module replacing
4.1.2 Drive board replacing
4.1.3 Switching power supply replacing
4.2 Attention and maintenance
4.3 FAQ
5. Problem shooting
Preface
Thank you for purchasing LED display from DMXTEC. We are submitting the instructions in
order to help you to make it easy when installing or use.
Please read this manual in detailed and carefully before installation.
This document is subject to changes without notice and all right reserved.
1. Safety precaution
2. Installation Screen
2.1 LED module dimension
51
41
31
21Rec
11
1
52
42
32
22
12
2
53
43
33
23
13
3
54
44
34
24
14
4
55
45
35
25
15
5
56
46
36
26
16
6
Back view
57
47
37
27
17
7
58
48
38
28
18
8
59
49
39
29
19
9
60
50
40
30
20
10
Select property, appearing Figure 3-2, then select option and then advance,
appearing Figure 3-3. Then click on display, appearing Figure 3-4. Click the red switch
in it on FPD item, the switch will turn green, then press ok.
Figure 3-3
Figure 3-4
mouse)Then select Install LED Studio to start the Installation Guide, as Shown in Figure
3-5. After that, simply follow the instruction on the screen. Note: This software is
protected by a serial number. Please enter the correct serial number in order to process
the installation. Please ask the products provider for the correct serial number.
After LED Studio software has been successfully installed, there will be a LED
Software program group in the Start/Program,then move to the LED Software
under this program group, click to start. Also, there will be a LED Studio short-cup on
your desktop. Also, you can start the program by double click on the icon.
Figure 3-5
3.4.2 Uninstall
LED Studio software provide an auto-uninstall function, for your convenience to delete
all LED Studio files, program groups and short-cuts, users can either select Delete LED
Studio under the LED Software group, or go to the control panel, select add/delete
program to undergo quick uninstall. (Uninstall window as shown in Figure 3-6, now
select Automatic can delete all files, program groups and short-cuts.
Figure 3-6
Figure 3-8
Figure 3-7
And then input linsn the 5 small letters.(computer screen shows nothing when inputting linsn by
keypad.), appear a dialog box, as shown Figure 3-9 to prompt you to input the password 168, then
enter setup dialog box. as shown 3-11
Figure 3-9
Figure 3-10
Figure 3-11
Figure 3-12
4.3 FAQ
1. The signal demo appears on screen occasionally
Probably caused by
1Connection failure between PC Serial COM port(RS232) and data collecting card.
2COM port is damaged
3Cable which connected with RS232 is damaged
4Incorrect configuration in hardware port of sender card
Solutions:
1Reconnect cable with PC COM(RS232)
2Change computer or repair the PC COM port
3Use new cable
4Modify the hardware port (open led studio-option-software setup-sender) to Auto or
com1
2. Dialog box with control system not found is appeared when run LED Studio
Probably caused by
1Connection failure between PC COM(RS232) and data collecting card
2PC COM is damaged
3Cable which connected with RS232 cable is damaged
4Incorrect configuration in hardware port of sender card
Solutions:
1Reconnect cable with PC COM(RS232)
2Change computer or repair the PC COM
3Use new cable.
4Modify the hardware port (open led studio-option-software setup-sender) to Auto or
com1
3. One row on a module or a cabinet doesnt work or works abnormally
Probably caused by
1Connection failure between driver and module.
2The relevant cable is damaged
Solutions:
1Reconnect the driver with module
2Use new cable
5. Trouble shooting
5.1 Control system
5.1.1 The whole screen doesnt work or works abnormally
Probably caused by
1Computer is power off.
2Connection failure between the data collecting card and the receiving card.
3Installation failure of data collecting card
4Connection failure of the cables between visual card and data collecting card or
receiving card
5Inaccurate hardware setup in the LED video software
Solutions:
1Turn on the computer
2Reconnect cables
3Reinsert data collecting card
4Reconnect the cables among the visual card , data collecting card and receiving
card.
5Correct parameters in hardware setup
Probably caused by
1No connection of the fifth OE signal in IC 138 chip.
2Connection failure of SCLK and RCK signals between Pins and IC 245
(open circuit or short circuit)
3Connection failure between OE signals. (open circuit or short circuit)
4Connection failure of SCLK and RCK signals between Pins and IC 245
(open circuit or short circuit)
Solutions:
1Connect the OE signal
2Reconnect the SCLK and RCK signals
3Reconnect the open circuit or cut off the short circuit
4Reconnect the open circuit or cut off the short circuit
5.2.4 Two rows in a cabinet work coinstantaneous (one row works well and
the other keeps bright without change when display letters)
Probably caused by :
1The relevant signals are short circuit.
2The output of IC138, resistancemodule pins and the output of IC4953 are short
circuit.
Solutions:
Cut off the short circuit
5.2.5 Half of a cabinet displays in red, green or blue or just two colors only,
or works abnormally.
Probably caused by :
1Failure of input pins or short circuit of GND, +5V.
2Connection failure between IC245 and input pins.short circuit or open circuit
3IC245 is damaged.
Solutions:
1Reconnect the open circuit or cut off the short circuit
2Reconnect the open circuit or cut off the short circuit
3Use new IC
5.3.2 The rest columns of one row in the display work abnormally from NO.
n column.
Probably caused by :
1Failure of the flat cable between the two data collecting cards which control No. n-1
and n columns separately.
2The relevant sockets in the data collecting card are damaged
Solutions:
1Use new cable
2Replace or fix the sockets.
5.3.5 Data collecting and receiving card data indicated lamps doesnt flash
Solutions:
1Check the network cable
2Check the network cable is international standard or not? (The right is 568B 1:White
orange 2: Orange 3:White green 4:Blue 5:White blue 6: Green 7:White brown
8:Brown)
3Right click on the space of your desktop- Select property- select option -then
advance -click on display -Click the red switch in FPD item, the switch will turn
green-press ok-restart your computer . Now it works
DMX Technologies
www.dmxtec.com