Professional Documents
Culture Documents
Flexi Bsc调试集成总结 修订版
Flexi Bsc调试集成总结 修订版
* site documents
<1>, Terminal
( terminal )
()
(,)
<2>, ESB ,,
SW256B ,SBMUX-A,ETS2HWAT
<2> check list flash EPROM ,
.
<3>,,
<4>(),
<5> CP816
BSC
* ,.
*
PC
* TANG , TANG
COM
BSC plugin
NED
1
2 PSFP ,
53V
3 PSFP , BCSU ()
4 PSFP ,,
5 , PSFP
6 , PSFP
7
8 ,, PSFP
9 plug-in ,,
OMU AS7 OMU
10 PC USB OMU J7 service terminal
11 PSFP , OMU,MCMU,BCSU
12 OMU , service terminal (TE WO)
13 :SYSTEM,SYSTEM ST, ZLP:1,VIM1C:1 MML
14 ZUSI:COMP;
15 , ST SP MCMU J7, MCMU
16 ST BCSU, BCSU
17 ST OMU J7 ZUSC:MCMU,X:WO; MCMU
18 MCMU , ST SP MCMU
19 ST BCSU, BCSU
20 , OMU,MCMU,BCSU
21 , PC LPT , OMU,MCMU,BCSU ,
22 ,(),
1. ZWQB:
2.ZWKS:MODE=FULL,NAME=FBXXXXXX,DIRE=ASB_2_18_0:;
3.ZWKI:
4.ZWQO:CR:;
(//ZWQD:)
( //ZWSD:)
3
(//ZWSC:)
BSC ZEWL
BCF ZEWO
ZEWA
ZEWV
FLEXI BSC U
ZIWY:S:SYSTEM=,UNIT=OMU,PATH=/FBXXXXXX,DRIVE=WDU-S,:;
ZIWY:D:SYSTEM=,UNIT=,PATH=/FBXXXXXX,DRIVE=UMS-N0,:;
ZIBC:,,,,,,,,,DIR:::;
23
ZDCE:PLUS:08-00;
ZDCS:2010-02-03,11-23-00:ST=OFF:; ()
ZUSS::C=DSK:STMU;
>ZQRA:OMU::EL0:1500:UP:; EL0
>ZQRN:OMU::EL0:192.168.0.10,P,:::; BSC IP
192.168.0.10
profile FTT
ZIAA:PROFILE1:ALL=250:PARAPW=,VTIME=FOREVER,ACCESS=LIM,U
NIQUE=NO,:TLIMIT=15:FTP=W:; ZIAA:PROFILE::::FTP=W:;
FTT_IE5.EXE
NOKIA BSC BSC
Setup->FTP Setup
Destination OMU-CPU IP Name Username
Password BSC SAVE
DX file->unit IP OPEN FTP
BSC COPY
COPY
(I/O)
1
2
3
4
5
ZISC::WDU,1:BL-US
ZISI::WDU;
ZISC::WDU,1:TE-ID;
ZISI::WDU;
ZUDD:OMU:WDU,1;
ZUDH;OMU:WDU,1;
ZISC::WDU,1:WO-ID
ZISI::WDU;
ZISC::WDU,1:WO-BU;
ZISI::WDU;
6 : ZDUR;
BSC
WDU/OMU
6
1 PC LPT LPT
2 PC MML ZUSI
3 SP MCMU MML ZAHO 2757
4 MCMU ZUSC WO
5 MCMU SP MCMU
6 LPT MML 2757
7 MCMU
8 BCSU LPT MML ZAHO
9 PDFU() LPT 2758
10 MCMU PDFU
12 2759 FTRB0 3GSWB0
1
CLOC0 1ET4C0 1
13 ZUSI
14 PDFU
15 LPT
16 ZUSI
1 25 ALARM EXT IN
2
1211109876543210
2322212019181716151413 0
9
3 :
Output the alarms
ZWAE:1A;
ZWAA:4000:EX:"TEST";
ZWAI:HWAT:OMU:0,4000,"TEST 0":; 0
25 0 ZAHO 4000
00000000
** ALARM ........
HWALCO
25 1 ZAHO 4000
7
00000001
** ALARM ........
HWALCO
4 2 9 4000
ZWAI:HWAT:OMU:2,4000,"TEST 2":;
ZWAI:HWAT:OMU:3,4000,"TEST 3":;
ZWAI:HWAT:OMU:4,4000,"TEST 4":;
ZWAI:HWAT:OMU:5,4000,"TEST 5":;
ZWAI:HWAT:OMU:6,4000,"TEST 6":;
ZWAI:HWAT:OMU:7,4000,"TEST 7":;
ZWAI:HWAT:OMU:8,4000,"TEST 8":;
ZWAI:HWAT:OMU:9,4000,"TEST 9":;
ZAHO 0-9 10
5
ZWAX:HWAT:OMU:0:POL=0,; 0
ZAHO 4000 0
ZWAX:HWAT:OMU:1:POL=0,; 1
ZAHO 4000 1
ZWAX:HWAT:OMU:2:POL=0,;
ZAHO 4000 2
ZWAX:HWAT:OMU:3:POL=0,;
ZAHO 4000 3
ZWAX:HWAT:OMU:4:POL=0,;
ZAHO 4000 4
ZWAX:HWAT:OMU:5:POL=0,;
ZAHO 4000 5
ZWAX:HWAT:OMU:6:POL=0,;
ZAHO 4000 6
ZWAX:HWAT:OMU:7:POL=0,;
ZAHO 4000 7
ZWAX:HWAT:OMU:8:POL=0,;
ZAHO 4000 8
ZWAX:HWAT:OMU:9:POL=0,;
ZAHO 4000
6
ZWAD:HWAT:OMU:0:;
ZWAD:HWAT:OMU:1:;
ZWAD:HWAT:OMU:2:;
ZWAD:HWAT:OMU:3:;
ZWAD:HWAT:OMU:4:;
ZWAD:HWAT:OMU:5:;
ZWAD:HWAT:OMU:6:;
8
ZWAD:HWAT:OMU:7:;
ZWAD:HWAT:OMU:8:;
ZWAD:HWAT:OMU:9:;
7
ZWAR:4000;
8
ZWAT;
1 BSC
2 BSC 25 ALARM OUT
3 0 5
4
ZALU:UPD
5 0 0
ZALS:0:ON
6 0 0
ZALS:0:OFF
7 1 5 ,X :
ZALS:X:ON
ZALS:X:OFF
MGW
1 CL3TG cartrige
2 ZUSICLS CLS ACTIVE
3 SP CLS FCTRL CLS ZUSICLS
CLS FCTRL
4 ZAHO EMB EMB
PLESIOCHRONOUSTPTR510
ZDRS::TP=1,TR=1,:; TP TR 1
11 ET ZDRS::U=2M1 2M1
ZDRI
< ZDRS::U=2M1;
LOADING PROGRAM VERSION 2.8-0
EXECUTION STARTED
BSC3i
INPUT
DZHOUBSC08
STATE
2006-08-11 11:41:35
2M1
2M2 FAULTY
2M3 FAULTY
2M4 FAULTY
FS1 FAULTY
FS2 FAULTY
FLEXI BSC
ZWTI:J;
10
ZWTI:C;
ZWTI:U;
ZWTI:P;
TCSM TCSM
ET
1 ET ET CARTRIGE
2 A GB
3 ET-PLAN
7 ET-PLAN ET A ABIS GB
ET A DBLFABIS
ET CRC4 ET-PLAN
E:\DX200-BSC\
FLEXIBSC A_INF ET_PLAN-.xls
: BCSU ET BCSU
BCSU SE-NH WO
ZWUC:ET,(ET ): :ETS2,0:IF=A:BCSU,0;
ZWUC:ET,(ET ):ETS2,0:IF=ABIS:BCSU,0;
ZWUC:ET,(ET ):ET16,0:IF=GB:BCSU,0; IP
ET ABIS
ZWTI:U:ET; ZWTI:P:ET; ZUSI:ET; ZWUP:(PCM ); ET
.
8 :
ZYEI:ET,(ET );
ZYEC;ET,(ET ):NORM,DBLF; ZYEC;ET,(ET ):NORM,CRC4;
9 ET TE :
ZUSC:ET,(ET ):SE ZUSC:ET,(ET ):TE
OMU/MCMU/BCSU
1 ZUSI:COMP
11
2 ET MCMU0MB0CLS0
WO
3 ZUSC:MCMU,1:TEZUDU:MCMU,1; MCMU1
4 ZUSC:EMB,1:TEZUDU:EMB,1; EMB1
5 ZUSC:CLS,1:TEZUDU:CLS,1; CLS1
6 SP BCSU TE ZUSC:BCSU,6:TE; ZUDU:BCSU,6;
7 ZUDH 3999
8 BCSU SP BCSU SPTE,
ZUSC:BCSU,6:SP; ZUSC:BCSU,5:SP; ZUSC:BCSU,5:TE; ZUDU:BCSU,5;
9 BCSU5 BCSU
10 STMU TE, ZUDU:STMU,32; STMU
11 SWU TE, ZUDU:SWU,32; SWU
12 EMB1 SP WO EMB0 TE
ZUSC:EMB,1:SP; ZUSC:EMB,1:WO; ZUSC:EMB,0:TE; ZUDU:EMB,0;
ZUDH:EMB;
13 CLS1 SP WO CLS1 TE
ZUSC:CLS,1:SP; ZUSC:CLS,1:WO; ZUSC:CLS,0:TE; ZUDU:CLS,0; ZUDH:CLS;
14 EMB1 WO ZUDU BCSU
15 ZUDU:ET,XXX ET ZUDH
16 MCMU1 TE SP WO MCMU0 SP TE
17 MCMU1 WO EMB WO
BCSU
18 MCMU1 WO ET
19 PC OMU J7 , OMU
OMU TE(ZUSC:OMU:TE;)ZUDU:OMU;ZUSC:OMU:WO;ZUDH:OMU;
ACTIVE MCMU, OMU
20I/O(U)UMS-0
ZISC::UMS,0:WO-ID;
ZISC::UMS,0:TE-ID;ZUDQ;
ZUDD:OMU:UMS,0;
ZUDH:UMS,0;
ZISC::UMS,0:WO-ID;
ZISC::UMS,0:WO-BU;
WDU,0/1
ESB24-D
ESB ESB CE
PC
12
1ESB
22RESET2ESB20
3ESB
4ESB
5ESB
USB ESB24-D SER1 ESB24D nsnswitch
nsn-switch
SWU-0>enable
SWU-0#self-test
SWU-0#reload
SWU2,4,1,3,5
OMU J7 PC IPSYSTEM
ZWQO;
ZWQO:CR;
ZWQB:STAT=<running_packet_status>;
ZWKI:;
13
ZQWO:CR; FB
TC commissioning
1 TC
2 site documents,PCST
3 site documents TC
4
5 site documents TR3E/TETS2SBMUX-A
EPROM
6 -41V -57V,-54v
7 ETS2TR3E/TSBMUX-A
8 TC
9 TR3E/T
22 TCSM TC Commission
CD4.1 CD4.2
1 BSC CD ZWQO:CR FM BSC CD
2 CD CD
14
fifilegx.IMG
CIDEXFSS.txt
prfilegx.IMG
FIFCNVGX.IMG
PRFCNVGX.IMG
E:\DX200-BSC\
FLEIXBSC-\BSCFEAHIT.tel
LICENSEZW7L::ON;
LICENSEZW7I:FEA,FULL:FSTATE=ON;
6. FEATUREZUSU:OMU:C=DSK,;
ZUSS::C=DSK,:STMU,,:;
TC ZWGC POOL
FEATURE
15
ET-PLAN TC
1 MSC ET-PLAN TCSM ET
2 BSC
3 TC :
INT MARCO.TXT
4 TCSM ET TE TCSM
5 MCMU TCSM
6 TCSM ET WO
ET-PLAN CCS77
1 2ME:\DX200-BSC\WLMQ
ZRCI:SEA=3:CGR=1:PRINT=5:; A
1 BSC
2 PC BSC
3 FTT BSC BCF_PACK
4 PC FTT BCF_PACK
BCF_PACK
6 BCF
7 BTSPLUS FLEXI BTS
16
8 INITIAL
< ZEWL;
ZEWA BCF
ZEWV
BCF L OMUSIG WO
BSC-BTS BSC
ZEWH BU
ZEWH:21:ST1=BU,ST2=FB;
ZEWE NW
GPRS GB
1 IP GB
E:\DX200-BSC\
FlexiBSC GBoIP .rar
2 Creat_Test_BTS
NSVC WO-EX
LAC SGSN GPRS
3 SERVICE TERMINAL
NSEI
E:\DX200-BSC\GB
TEST.TXT
IP
1 ZQRI OMU IP NSN
BSC OMU IP
2 ZQRL NSN
BSC
3 OMU IP ZQRN:OMU::EL0:10.238.58.162,P,:27:UP:;
27 NSN IP 255.255.255.224
(1 27 )
5 BSC IP
BSC
TN BSC
BS_CV_MAX=9
ZEGP:14:9:;
3 ZWOIS14 BSC
4 ZWOSS14 BSC
5 BSC UNLOCK
18
BSC ,:
ZIFO:OMU:MEASUR:1&&20;
BSC3i
DZHOUBSC07
FILE
2006-09-06
13:46:02
ORIGINAL/
NUMBER STATUS
COMPRESSED
FILLING TIME
TRANSFER TIME
TRANSFERRED
OK/--
- - -
2006-09-06 11:01:34
2006-09-06 13:26:23
TRANSFERRED
OK/--
- - -
2006-09-06 12:01:34
2006-09-06 12:01:38
TRANSFERRED
OK/--
- - -
2006-09-06 13:01:34
2006-09-06 13:01:38
TRANSFERRED
--/--
- - -
0000-00-00 00:00:00
2006-06-22 09:25:59
TRANSFERRED
--/--
- - -
0000-00-00 00:00:00
2006-06-22 09:25:59
TRANSFERRED
--/--
- - -
0000-00-00 00:00:00
2006-06-22 09:25:59
TRANSFERRED
--/--
- - -
0000-00-00 00:00:00
2006-06-22 09:25:59
TRANSFERRED
--/--
- - -
0000-00-00 00:00:00
2006-06-22 09:25:59
TRANSFERRED
--/--
- - -
0000-00-00 00:00:00
2006-06-22 09:25:59
10
TRANSFERRED
--/--
- - -
0000-00-00 00:00:00
2006-06-22 09:25:59
11
TRANSFERRED
--/--
- - -
0000-00-00 00:00:00
2006-06-22 09:25:59
12
TRANSFERRED
--/--
- - -
0000-00-00 00:00:00
2006-06-22 09:25:59
13
TRANSFERRED
--/--
- - -
0000-00-00 00:00:00
2006-06-22 09:25:59
14
TRANSFERRED
--/--
- - -
0000-00-00 00:00:00
2006-06-22 09:25:59
15
TRANSFERRED
--/--
- - -
0000-00-00 00:00:00
2006-06-22 09:25:59
16
TRANSFERRED
--/--
- - -
0000-00-00 00:00:00
2006-06-22 09:25:59
17
TRANSFERRED
--/--
- - -
0000-00-00 00:00:00
2006-06-22 09:25:59
18
TRANSFERRED
--/--
- - -
0000-00-00 00:00:00
2006-06-22 09:25:59
19
TRANSFERRED
--/--
- - -
0000-00-00 00:00:00
2006-06-22 09:25:59
20
TRANSFERRED
--/--
- - -
0000-00-00 00:00:00
2006-06-22 09:25:59
7
BSC
ZEFP;
TEXT-ID
/////Add TEXT-ID if required in the new BSC//////////////////////////////
ZEFE:TID=1:TEXT="DISCONNECT OF SMOKE SENSOR";
ZEFE:TID=2:TEXT="SMOKE ALARM";
19
ZEFE:TID=3:TEXT="WATER ALARM";
ZEFE:TID=4:TEXT="TEMPERATURE ALARM";
ZEFE:TID=5:TEXT="AIR-CONDITION STOLEN ALARM";
ZEFE:TID=6:TEXT="INTRUSION ALARM";
ZEFE:TID=7:TEXT="AIR-CONDITION FAILURE";
ZEFE:TID=8:TEXT="BATTERY HIGH/LOW ALARM";
ZEFE:TID=9:TEXT="RECTIFIER FAILURE";
ZEFE:TID=10:TEXT="AC DOWN";
ZEFE:TID=11:TEXT="AC PHASE LACK";
ZEFE:TID=12:TEXT="AC HIGH/LOW ALARM";
BSC
ZEFP;
8 BSC BSC
BSC ZABO;
BSC BSC
ZABB:690:;
ZABB:2842;
ZABB:2518;
ZABB:1254;
ZABB:1103;
ZABB:1569;
ZABB:430;
ZABB:27;
ZABB:1570;
ZABO;
8 BSC BSC
BSC ZEOE:;
BSC
ZEOB:7615;
ZEOB:7890;
ZEOB:7990;
ZEOB:7991;
ZEOE;
20