You are on page 1of 1

NOTES:

1. All dimensions are in millimeters


2. Use class class 25 for bases &beams ,
class 25 for columns and 20 for the slab
3.Read this drawing in conjunction
with relevant Architectural drawings.
4. Minimum cover for concrete is:
a. Foundation = 50mm
b. Columns = 25mm
c. Beams = 25mm
d. Slabs = 25mm
5. All reinforcement to be twisted bars
B.S 4449.
6. All steel reinforcement must be
approved by the Structural Engineer

3500

02

500

LEVEL 3

02

3500

SECTION X04-X04

50 x Bar Dia.

500

LEVEL 2

3500

02

SECTION X03-X03

T8-02

250
SECTION X03-X03
4T16-04+2T12-05
50 x Bar Dia.

6T16-06

LEVEL 1

T8-02

4T16-06+2T12-07

T8-03

250

50 x Bar Dia.

LEVEL 1

50 x Bar Dia.

500
03

500

SECTION X03-X03

500

500
3500
50 x Bar Dia.

LEVEL 2

6T16-06
50 x Bar Dia.

4T16-04+2T12-05

SECTION X04-X04

03

03

250

6T12-08

250

4T16-07+2T12-08

T8-03

3500

3500

SECTION X03-X03

3500

LEVEL 2

T8-02

250
02

SECTION X04-X04

SECTION X05-X05

T8-03

250

4T16-07+2T12-08

500

500

LEVEL 2

LEVEL 3

T8-02

250

6T12-09

50 x Bar Dia.

03

3500

SECTION X04-X04

T8-03

SECTION X05-X05

T8-03

250

50 x Bar Dia.

02

03

T8-02

4T16-06+2T12-07

50 x Bar Dia.

LEVEL 3

500

500

LEVEL 3

ROOF LVL

250

6T12-09

50 x Bar Dia.

02
50 x Bar Dia.

3500

SECTION X05-X05

6T12-08

250

3500

250

3500

3500

SECTION X05-X05

T8-03

03

T8-02

250

50 x Bar Dia.

ROOF LVL

500

ROOF LVL

500

ROOF LVL

LEVEL 1

LEVEL 1

REVISION

REV

SIGN DATE APPROVED

C4

T8-03

500

T8-02

500

500

500

C3

T8-03

C2
T8-02

C1
02

4000

250
C0
CLIENT

4T20-04+2T16-05

GF LVL

SECTION X02-X02
6T16-03

50 x Bar Dia.

GF LVL

SECTION X02-X02

50 x Bar Dia.

4T20-04+2T16-05
50 x Bar Dia.

50 x Bar Dia.

6T16-03

SECTION X02-X02

03

03

SECTION X02-X02

250

4000

250

4000

02

4000

250

GF LVL

GF LVL

500

500

SECTION X01-X01

CONSULTING CIVIL STRUCTURAL ENGINEER

6T16-01

BELHMANN CONSULTANTS
P.O BOX 36014-00200,
NAIROBI, KENYA
TEL:254717865382/704845027

500

75

250
02

Depth to be
Det. on site

03

SECTION X01-X01
4T20-01+2T16-02

PROPOSED HOTEL
IN
MOGADISHU

T8-02

T8-02

250

500

75

75

500

SECTION X01-X01
4T20-01+2T16-02

500

SECTION X01-X01
6T16-01

T8-03

T8-03

250
03

Depth to be
Det. on site

T8-03

250
02

Depth to be
Det. on site

T8-03
Depth to be
Det. on site

T8-02

T8-02

75

500

500

PROJECT

belhmannconsultants@gmail.com
ARCHITECT

COLUMN C01
TYPE 1

COLUMN C02
TYPE 2

COLUMN C03
TYPE 3

COLUMN C04
TYPE 4

DRAWING TITLE

COLUMN DETAILS

Designed by
Checked by

Drawn by

D.O.O
N.B

Scale

Approved by
Date

AS INDICATED ON THE DRAWING

Job No.
Status

01-MOG

March 2016

ACAD File:

Drawing No.01/2016/MOG-11

B.O.O
D.O.O

STR01-MOG
CO REV

You might also like