Professional Documents
Culture Documents
http://excelcalculations.blogspot.com
Parameters
Feed Flowrate
Feed Frac Light Component
Top Prod Frac Light Component
Bottom Prod Frac Light Component
Reflux Ratio
Relative Volatility
q-line
F
xF
xD
xW
R
Calculations
Top Product Flowrate
D
Bottom Product Flowrate
W
Liquid Flow at Top of Column
L
Vapour Flow in Top of Column
V
Liquid Flow in Bottom of Column
L'
Vapour Flow in Bottom of Column
V'
X Coords of Op Line Intersection
qx
Number of Plates (plus Reboiler)
Feed Plate (From Top of Column)
Minimum Reflux Ratio (Underwood)
Minimum Num Theoretical Places (Fenske)
Assumptions:
Equilibrium Reboiler
Total Condensor
Constant Relative Volatility
75 kmol h-1
0.4 mol frac
0.99 mol frac
0.1 mol frac
3
4
0.75
1.0
0.0
0.0
e-Thiele Method
t in Liquid Phase