Leg en d & N otes:

WALLSTATION LINK AND PANEL


LINK USE GRX-CBL-346S-500
OR REQUIRES 2 #12 AWG
2
(2.5MM ) CLASS II WIRES PLUS
ONE BELDEN #9461 (TWO CORE,
2
1MM , SHIELDED, TWISTED PAIR).

Typical Equipment Layout


TU240-9DC-3-BL
external power supply

W ire le s s d im m e r
6 4 p e r w ire le s s lin k

Grafik Eye and WPM units


(maximum 8 per link)

T a b le T o p K e yp a d
3 2 p e r s ys te m

S ig n a l R e p e a te r
5 p e r w ire le s s lin k

Keypads Link

HWI-WPM-6D-230CE
Wallbox Power Module
Address: AX
Location:X

HWI-WPM-6D-230CE
Wallbox Power Module
Address: AX
Location:X

HWI-WPM-6D-230CE
Wallbox Power Module
Address: AX
Location:X

HWI-WPM-6D-230CE
Wallbox Power Module
Address: AX
Location:X

Maximum 32 keypads per link


Maximum 10 keypads
per home run.
Maximum 305m (1000 feet)
per home run.
Maximum 1220m (4000 feet)
total wire lenght.

GRX-3X04-T-WH
Address AX
Zones: AX-1 thru AX-4
Function: Scenes 1-4 and Off

GRX / WPM Link

HWI-LV24-CE

Keypads and Contact Closures,


CCI & CCO
(maximum 32 per link)

HWI-WCI

Maximum 8 Units per link


Maximum 610m (2000 feet)
total daisy-chain

L o c a tio n : X

LINK 8

H W IS - 5 B R L - F - B N
A d d re s s : X
5 B u tto n K e y p a d
w ith R a is e / L o w e r
L o c a tio n : X
1

H4P5-H48-HRL-CE
H4P5-HRL-CE

LINK 6

LINK 5

LINK 4

CCO

LINK 8 only available for models H4P5-H48-HRL-CE and H4P5-HRL-CE

U p to te n k e yp a d s p e r h o m e ru n

Interprocessor Link
H W IS - 5 B R L - F - B N
A d d re s s : X
5 B u tto n K e y p a d
w ith R a is e / L o w e r
L o c a tio n : X
10

Maximum 305m (1000 feet)


total daisy-chain

LINK 3

RS232 Link

LINK 2

H W IS - 5 B R L - F - B N
A d d re s s : X
5 B u tto n K e y p a d
w ith R a is e / L o w e r
L o c a tio n : X

H W IS - 5 B R L - F - B N
A d d re s s : X
5 B u tto n K e y p a d
w ith R a is e / L o w e r
L o c a tio n : X

CCI

H W IS - 5 B R L - F - B N
A d d re s s : X
5 B u tto n K e y p a d
w ith R a is e / L o w e r
L o c a tio n : X

CCI

CCO

Maximum 15m (50 feet)


total point-to-point

Rev:

Reason For Revision

Date

P roject N a m e:

H o m e W o rk s P a n e l
H W I- C C O
A d d re ss : X
M o u n te d in H W I- L V 2 4
C o n ta c t C lo s u re In te rfa c e
O u tp u t C o n ta c t C lo s u re s
to o th e r's e q u ip .

H W I- C C O
A d d re ss : X
M o u n te d in H W I- L V 2 4
C o n ta c t C lo s u re In te rfa c e
O u tp u t C o n ta c t C lo s u re s
to o th e r's e q u ip .

H O M EW O RK S
4 Series Exam p le

Concept Only Schematic.

LUTRON
C o n n e c t to a u d io , h o m e
a u to m a tio n , a n d o th e r
d e vic e s c o n tro lle d u sin g
RS- 232

U P TO 96
SVQ- EDU

Lu tron EA Ltd.
Lu tron H ou se
6 S overeign C lose
Lo nd on , U K
E1 W 3 JF
Tel + 44 (0 )20 - 7 70 2 - 06 5 7
Fax + 44 (0 )2 0 - 7 48 0 - 68 9 9

S V Q - ED U

POWER SUPPLY
24VAC

H W I- Q 9 6
In te rfa c e H W I- S ivo ia Q E D
S yste m
A d d re s s: 1
Z o n e s: X z X th ru X z X
Lo c a tio n : X

IN FO RM ATIO N O N LY
13- 01- 2011

Rev:A