You are on page 1of 2

MicroPower Direct

Go Direct - MicroPower Direct - For Product, Performance and Price

200W AC-DC ACTIVE PFC SWITCHING POWER SUPPLY


PRL9802 SERIES
FEATURES:
w Protections: Short Circuit/ Over Load/ Over Voltage/ Over Temp
w Providing Peak Power 600W within 500uS duty duration
w Power Factor Corrected to EN61000-3-2 class D
w Compact Size: 6.8W X 3.8L X 1.5H inches
w Approved to UL CUL TUV CE and CB
w Optional Top Cover & Fan Drive
w Universal AC input

CB

PRODUCT SPECIFICATIONS:
Input Voltage: 47~63Hz, 90 - 264Vac full range
Input Current: 4A at 100VAC
Inrush Current: 70A peak maximum (Measuring at 230VAC and
full load cold start.);35A peak maximum (Measuring at 110VAC
and full load cold start.)
Harmonic PFC: Power Factor Correction pass EN61000-3-2
class D
Fan Drive: 12VDC/400mA is available to drive an external fan
Transient Response: Output voltage return to within 1% in less
than 500us for a 50% dynamic load peak does not excess 5%
Overshoot: Turn-on and turn-off overshoot should not exceed 5%
over nominal voltage
Efficiency: Minimum 80% on 12-48V models, 70% on 3.3 and 5V
models at 230Vac full load
Turn On Delay: 1 second maximum at 120 VDC
Hold Up Time: 20 Msec minimum at 120 VAC and 80% of rated
maximum load
Adjustability: Output user adjustable +/-5% minimum
Input Circuit Protection: A protected 250V/5A fuse inserted. The
fuse shall be blown only by an internal fault of the power supply,
but no create a fire or shock hazard
Over Current Protection: Current limits at 110-135% of the rated
output current and recovers automatically
Short Circuit Protection: Short circuit can be continuous without
damage and recovers automatically
Over Voltage Protection: Output is protected against over
voltage. Unit latching down will occur when output exceed 130%,
and recycle AC input to reset
Over-Temperature Protection: Power supply protected in the
event of excessive operating ambient 85 degree, and automatic
recovery
Operating Temperature: 0 to 50 degrees C
Storage Temperature: -20 to 85 degrees C
Operating Humidity: 5% to 90% RH, Non-condensing
Storage Humidity: 5% to 95% RH, Non-condensing

Vibration: Frequency 5 to 50 Hz, acceleration +/-7.35 M/(SxS) on


X,Y and Z Axis
Remote On-Off: Designated as REMO on the CN3. Requires a
low signal to inhibit output. Supply will hiccough when remote onoff fall to low level
Power Good: Designated as PG on the CN3. This signal will go
high 100-500 Msec after the output reaches the regulation limit. It
goes low at least 1 Msec before loss of regulation
Remote Sense: Designated as RS+ and RS- on the CN3. Total
voltage compensation for cable losses respect to the main output.
Power Supply On: Green LED designated as LED 1 on the PCB.
EMC Compliance: EN55022-EMI compliance to EN55022 class
B and meet FCC Part 15 Subject J class B Disturbances
compliance to EN61000-3-2/-3; EN55024-Compliance to
IEC61000-4-2/-3/-4/-5/-6//-11
Safety Regulation: Approved to UL60950, CSA22.2 No. 60950,
EN60950 CE Mark, CB
Leakage Current: The AC leakage current shall not exceed
3.5mA when the power supply is connected to a supply voltage
equal to the upper limit of the rated voltage range
HI-POT Test: The power supply shall withstand for 3 Sec without
breakdown the application of a 1500 VAC supply voltage applied
between both input line and chassis (10mA DC cut off current).
Isolating transformers shall withstand 3000VAC applied between
primary and secondary windings and primary to core 1500VAC.
Grounding Test: Apply 25 A current from the ground pin of the
three prong plug to the far most earthed connection point. The
maximum allowable resistance measured is 0.1ohm
Warranty: 2 years
MTBF: 100000 Hrs (according to MIL-HBK-217F) at 30 degree C
Cooling: 17 CFM requires achieving full ratings
Burn in: Applying 230VAC for input voltage. Applying full load for
this product in 45 +/- 5 degree C burn-in room for 1 hour.
Enclosure: 6.8W X 3.8L X 1.5H inches U-case
Weight: Maximum weight is 650g

MicroPower Direct
www.micropowerdirect.com
232 Tosca Drive Stoughton, MA 02072

TEL: (781) 344-8226

FAX: (781) 344-8481

E-Mail: sales@micropowerdirect.com

MicroPower Direct
Go Direct - MicroPower Direct - For Product, Performance and Price

OUTPUT VOLTAGE / CURRENT RATING CHART: Measured at output power connector.


Model

Output Range

Max. Output current

Regulation

Ripple & Noise

PRL9802SA

3-4V

30A

+/- 1%

50mV

PRL9802SB

5-6V

40A

+/- 1%

50mV

PRL9802SC

12-18V

16.7A

+/- 1%

+/- 1%

PRL9802SD

24-30V

8.34A

+/- 1%

+/- 1%

PRL9802SE

36-56V

5.55A

+/- 1%

+/- 1%

* Providing peak power to 600W within 500uS for all models, longer duty duration need contact manufacture.
* All output range are covered in agencies certification and the preset voltage will be set as standard models if any request is
not standard output then should contact us in advance.
* Maximum 200W continuous output, with minimum 17 cfm forced ventilation.
* Maximum 150W continuous output with air convection, except PRL9802SA and PRL9802SB which power is limited to 22A
* Output is fully isolated.
* Ripple and noise measured from 10KHZ to 20MHz at output terminals with parallel 0.1F ceramic and 22F electrolytic capacitors.

OUTLINE DRAWING: Overall Size: 6.8(L) x 3.8(W) x 1.5(H)inches; Weight: Maximum weight is 650g

H O U S I N G P I T C H 2 .5 m m
( J S - 2 0 0 1 - 0 6 O R E Q U .)

INPUT

Line
Neutral
GND

VO-

VO-

VO+

VO+

OUTPUT

F A N H O U S IN G
P I T C H 2 .5 m m
( J S - 2 0 0 1 - 0 2 O R E Q U .)

A : M O U N T IN G H O L E
S C A L E 4 :1 ( 8 X ) B R E S S

T E R M IN A L B L O C K
( P a r t N o . H D - 3 0 1 -4 P )
M 4 S C R E W 4 P IN S , 1 1 m m C E N T E R

T E R M IN A L B L O C K
M 3 S C R E W 3 P IN S
7 .6 2 m m C E N T E R
( P a rt N o . F T B -7 0 2 - 3 P )

M O L E X P A R T N O . 0 9 - 9 1 - 1 2 0 0 (1 2 P IN S )

M O L E X P A R T N O . 0 9 - 9 1 - 0 5 0 0 (5 P IN S )
P I N N O .2 ,4 N C

Notes:
AC Input Connector: Mating Molex Part No. 09-91-0500 or equivalent (5 pin,3 used) PCB is Labeled: L = Line; N = Neutral; G =
Chassis Ground Mating Pins; Molex Engineering Series 2478, 2578, 8818 or Howder Terminal block Part No. FTB-702-3P (3 pin)
Output Connector: Mating Molex Part No. 09-91-1200 (12 pin)
Howder
Molex
or Howder Terminal block Part No. HD-301-4P (4 pin)
Output Pin Assignment: (See table in right)
VO+ : Pins 1-2
VO+ : Pins 1-6
Logic signal connectors (CN3):
Mating JST XHP-6 or equivalent (CHYAO SHIUNN JS-2001-06)
VO- : Pins 3-4
VO- : Pins 7-12
Mating Pins: JST SXH-002T-P0.6 FOR AWG 30 TO 26
Fan Drive: Mating JST Part No. XHP-2 or equivalent (CHYAO SHIUNN JS-2001-02)
Mounting Inserts: 8 Places M4. Maximum Penetration 4mm see outline drawing for location.

MicroPower Direct
www.micropowerdirect.com
232 Tosca Drive Stoughton, MA 02072

TEL: (781) 344-8226

FAX: (781) 344-8481

E-Mail: sales@micropowerdirect.com