Professional Documents
Culture Documents
01-04-06 -
Jim Clark
ABB Inc.
Demystifying Metric:
NEMA vs. IEC
Motors
$%%
General Overview
Company name - 2
$%%
Merging of Standards
IEC enclosure and ventilation codes (IC) are now in the NEMA MG
standards
Efficiency calculations
IEC assumes a fixed value for stray losses, NEMA measures them
Company name - 3
$%%
Company name - 4
Insulation classes
Output characteristics
Ambient
Duty cycles
Altitude
Dimensional nomenclature
Efficiency classes
Mounting positions
Service factor
Cooling codes
$%%
Power Ratings
HP x 0.746 = kW or kW/0.746 = HP
Company name - 5
There are some exceptions, and in these cases there can be frame
size differences to be taken into consideration
$%%
220
240
380*
400*
415
500
660
690*
60 HZ
230
---
440
460
480
575
---
---
Company name - 6
10
12
RPM 60 HZ
3600
1800
1200
900
720
600
RPM 50 HZ
3000
1500
1000
750
600
500
$%%
Service Factor
Company name - 7
Primary uses
$%%
Company name - 8
Insulation Classes
$%%
Efficiency Classes
Efficiency definitions
Company name - 9
EPAct 1 to 200 hp
1.1 to 90 kW
EPAct in US
$%%
Altitude
Altitude ft
Company name - 10
Derate Factor
100
96
92
88
84
3500
80
4000
76
$%%
Ambient
Company name - 11
Ambient C
40
45
50
55
60
65
70
80
Ambient F
104
113
122
131
140
149
158
176
Derate Factor
100
96.5
93
90
86.5
83
79
70
$%%
Company name - 12
IEC specifies detail using letter & number codes for definition
IC 411 TEFC
IC 416 TEBC
IC 01 ODP
$%%
Example
Company name - 13
The means for automatic draining may be a check valve or a tapped hole at the
lowest part of the frame which will serve for application of a drain pipe.
$%%
Company name - 14
Second Number
No protection
No protection
Objects > 50 mm
Objects > 12 mm
Sprayed water
Objects > 1 mm
Splashed water
Dust protected
Water jets
Dust-tight
Heavy seas
Effects of immersion
Indefinite immersion
$%%
Mounting Positions
Every combination of
orientation, feet and/or
flanges has a specific
designation
Short form
Company name - 15
IM x yy z => IM 1001
x = construction type
yy = mounting
arrangement
z = # of shaft
extensions
$%%
Terminal Boxes
Company name - 16
$%%
Company name - 17
$%%
Company name - 18
IEC
56
63
71
80
90
100
112
132
160
180
200
NEMA
---
42
48
56
140
---
180
210
250
280
320
IEC
315
355
400
450
500
560
630
710
NEMA
500
580
680
700
800
---
---
---
$%%
Starting torque Ts
Company name - 19
IEC designations
Nominal torque TN
$%%
A
D
B
250
% Rated Torque
C
200
150
100
Company name - 20
50
0
0
10
20
30
40
50
60
% Synchronous Speed
70
80
90
100
$%%
Output Characteristics
Company name - 21
$%%
Dimensional Designations
Company name - 22
Length:
NEMA = C, IEC = L
Shaft height:
NEMA = D, IEC = H
Shaft diameter:
NEMA = U, IEC = D
$%%
ATEX Directive
Product Directive 94/9/EC (ATEX 100a*/ ATEX 95**)
Company name - 23
$%%
Company name - 24
$%%
Company name - 25
CLASS I
Group A: Acetylene
CLASS II
CLASS III
Easily ignitable fibers, such as rayon, cotton, sisal, hemp, cocoa fiber,
oakum, excelsior and other materials of similar nature
$%%
Company name - 26
NEC 500
Classification
Division 1
Zone 1/21 & 22 C
Division 2
Zone 2/22 NC
Acetylene
Class I, Group A
Flameproof
Ex d IIC T4
Non-Sparking
Ex nA II T3
Hydrogen
Class I, Group B
Flameproof
Ex d IIC T4
Non-Sparking
Ex nA II T3
Ethylene
Class I, Group C
Flameproof
Ex d IIB T4
Non-Sparking
Ex nA II T3
Propane
Class I, Group D
Flameproof
Ex d IIA T4
Non-Sparking
Ex nA II T3
Methane
Mining*
Group I*
---
Metal dust
DIP
IP 65 Ex tD A21
DIP
IP 55 Ex tD A22
Coal dust
DIP
IP 65 Ex tD A21
DIP
IP 55 Ex tD A22
Grain dust
DIP
IP 65 Ex tD A21
DIP
IP 55 Ex tD A22
Fibers
Class III
---
---
* Not within the scope of NEC, falls under the jurisdiction of MHSA
$%%
Company name - 27
Zone 1 / 21
Zone 2 / 22
In abnormal conditions
(Less than 10 hours per year)
Zone 0 / 20
Zone 2 / 22
Present in abnormal
conditions, typically less than
10 hours per year
Zone 1 / 21
Occasionally
(10 to 1000 hours per year)
Zone 0 / 20
Continuously
(> 1000 hours per year)
$%%
Company name - 28
Flameproof (Ex d)
The shape, length and gap of part assembly joints, at shaft opening,
cable entries, etc., shall be designed to allow for throttling and
cooling of hot gases escaping outside
Ex de variant
$%%
Company name - 29
$%%
Company name - 30
$%%
Company name - 31
$%%
Summary
Company name - 32
$%%