You are on page 1of 1

GATRO POWER ( TURBINE SECTION )

BOILER ( HRSG )
STEAM GENERATION PLANT PACKAGE OF ( PRE-HEATER + ECONOMIZER + BOILER + SUPER-HEATER )
DESIGNED BY GRESHAM'S INT. PAKISTAN
BOILER MANUFACTURER
JOHNSTON HEAT RECOVERY USA
TYPE
WATER TUBE PACKAGE HRSG
MODEL #
REVOLUTION CDV 32 3014
BOILER #
B.N 289
CAPACITY @ 10BAR SATURATED
7569 KG/HR (By Heat recovery) , KG/HR (By Burner fire)
CAPACITY @ 42BAR SATURATED
11337 KG/HR (By Heat recovery) , 16002 KG/HR (By Burner fire)
BOILER HEATING SURFACE ( WITH FINS )
19232 SQFT.
ECONOMIZER HEATING SURFACE ( WITH FINS )
12758 SQFT.
PRE HEATER HEATING SURFACE ( WITH FINS )
N/A
SUPER HEATER HEATING SURFACE ( WITH FINS ) 1100 SQFT.

BURNER DETAIL
BURNER MAKE
BURNER INPUT FUEL
LHV
GAS (NG) CONSUMPTION
DENSITY
TEMPERATURE
PRESSURE AT VALVE TRAIN INLET
BURNER OPERATING CONDITIONS
EXHAUST GAS FLOW
OXYGEN CONTENT ( WET )
INLET TEMPERATURE
BURNER DUTY
PRESSURE AT BURNER (ESTIMATED)
MAX. FLAME LENGTH
Prepared by : MEHBOOB AHMED (SDM)

ECLIPSE BV , NETHERLANDS
NATURAL GAS (NG)
30400 KJ/Nm
809.18 BTU/Scf
28576 BTU/m
860 m/h (MAX ON 80% BOILER EFFICIENCY)
0.81 Kg/Nm
15 C
210 ~ 560 m bar
ON G.T 100%
ON G.T 90%
FRESH AIR MODE
20.13 Kg/s
20.13 Kg/s
8.33 Kg/s
14.50%
14.50%
20.70%
510 C
491 C
15 C
4800 KW
5600 KW
6000 KW
70 m bar
95 m bar
110 m bar
1.6 m
19 m
3.2 m