You are on page 1of 7

Data Sheet

WPS-01
Weatherproof Call Station, 1 Toggle

At a Glance:

The call station WPS-01 with four-wire technology is designed for use in harsh
environments. The housing is weatherproof and is suitable for a temperature range of
-30 C to +70 C.
It is used primarily as either level crossing intercom or gate intercom.

Level crossing intercom function

Gate intercom function (optional)

1 toggle (1 way) with LED

Comes standard with built-in 25 Watt booster amplifier

Weatherproof design (protection rating IP65)

Large temperature range (-30 C to +70 C)

Resistant to many chemicals

Flame resistant

Easy installation

Fig. WPS-01 (level crossing call station, L- No. 1.301)

Date: 16.03.2009 Page: 1/7 Author: HS Document no.: DB_WPS-01_1301_01


2008 ProCom, All rights and technical changes reserved
Data Sheet
WPS-01
Weatherproof Call Station, 1 Toggle

General Data WPS-01:

The WPS-01 consists of:

The mechanical components:

- Two-part housing made of glass fibre reinforced polyester in yellow


(RAL 1004)

- Toggle made of glass fibre reinforced grey polyamide

- Microphone box made of grey PVC for the dynamic sound capsule
(mounted in the cover)

- Cable connections made of grey polyamide

- Plastic plate in white with black writing

The electrical components:

- Dynamic sound converter (mounted in microphone box)

- 4 W/6 W loudspeaker (mounted in the cover)

- Motherboard with 4 W call station amplifier including 25 W booster


amplifier (mounted in housing base)

- Keypad circuit board (mounted in the cover)

Cover and housing base are connected electrically through a plug-in ribbon cable.

The WPS-01 is connected to the DVS-21 through the analogue LF interface


module 4NSA.

Voice transmission between the call station and the DVS-21 is analogue. Control
and data transmission is handled by a microcontroller. Transmission is carried out
with a modem connection.

Additionally, external 100 V loudspeakers (optional also 50 V or 70 V) up to a max.


of 25 Watt can be connected.

Date: 16.03.2009 Page: 2/7 Author: HS Document no.: DB_WPS-01_1301_01


2008 ProCom, All rights and technical changes reserved
Data Sheet
WPS-01
Weatherproof Call Station, 1 Toggle

Description Level Crossing Intercom:

Because of varying distances between the individual components, and the


technical requirements resulting from this, the level crossing intercom is made in
two variations:

Variation 1: Operation on non-isolated lines


The call stations at level crossings are supplied centrally from the
DVS-21.

Variation 2: Operation on isolated lines


The call stations at level crossings are supplied locally with 48 V.

Schematic illustration of a level crossing intercom

The above illustration shows the configuration of an level crossing intercom with
two central exchanges connected through an E1 interface.
When only one DVS-21 is used then the 4FTR (with E1 attachment) is
unnecessary.
The distances possible between the individual components vary depending on the
sections:

Section 1: Distance between the DVS-21 systems.


With suitable 2 Mbit/s transmission technology any distances
are possible.

Section 2: Distance between control call station and the DVS-21 system.
Typical range <500 m

Section 3: Distance between the level crossing (level crossing call


stations) and the DVS-21 system.

The distances achievable in section 3 depend on the kind of supply and the cable
diameter used.

Date: 16.03.2009 Page: 3/7 Author: HS Document no.: DB_WPS-01_1301_01


2008 ProCom, All rights and technical changes reserved
Data Sheet
WPS-01
Weatherproof Call Station, 1 Toggle

Variation 1 (central supply):

For a sound pressure of 90 dB(A) with a 1 m interval for the level crossing call
station and a supply voltage of the central exchange of 48 V the following
distances between the level crossing call station and the central exchange are
possible:

(Phantom
Cable Power
Diameter Supply)
[mm] 3 TW [km]
2 TW [km]
0.6 1.2 1.9
0.8 2.2 3.3
1.2 4.9 7.4

Variation 2 (local supply):

A maximum line attenuation (LF) of 10 dB results in:

Cable Typical LF
Diameter Range
[mm] [km]
0,6 6,5
0,8 8,5
1,2 14

Description Gate Intercom:

The WPS-01 can optionally also be used as gate call station. The standard colour
is RAL 2004 (orange) and the text is customer-specific.
The same parameters apply for this as with the intercom cabinets.

This function can be realized with every other ProCom call station; optionally also
with door call stations from third-party suppliers.

Date: 16.03.2009 Page: 4/7 Author: HS Document no.: DB_WPS-01_1301_01


2008 ProCom, All rights and technical changes reserved
Data Sheet
WPS-01
Weatherproof Call Station, 1 Toggle

Mechanical Data:

Height x Width x Depth: 400 mm x 100 mm x 128 mm

Cable Screws: 1 x M25, 2 x M20

Weight: Approx. 4 kg

Date: 16.03.2009 Page: 5/7 Author: HS Document no.: DB_WPS-01_1301_01


2008 ProCom, All rights and technical changes reserved
Data Sheet
WPS-01
Weatherproof Call Station, 1 Toggle

Technical Data:

Operating Voltage: 48 V DC

Power, Intercom Amplifier: 4W

Power, Booster Amplifier: 25 W

Idle Current: 25 mA

Current Consumption (Sending): 35 mA

Current Consumption (Receiving)


Without Booster Amplifier: Max. 200 mA

Current Consumption (Receiving)


With Booster Amplifier: Max. 1200 mA

Nominal Impedance: 600

Frequency Range: 300 - 8000 Hz

Microphone: Dynamic, directional

Control Range
Volume Compressor: 20 dB (speaking distance1030 cm)

Sound Pressure Level: >94 dB (distance 1 m)

Protection rating: IP65

Expandable: Up to 3 additional keypads AWC-06

Date: 16.03.2009 Page: 6/7 Author: HS Document no.: DB_WPS-01_1301_01


2008 ProCom, All rights and technical changes reserved
Data Sheet
WPS-01
Weatherproof Call Station, 1 Toggle

Accessories:

- Sound insulation hood: L-No. 1.340 from V2A,


H x W x D = 1000 x 600 x
500 mm
Weight: approx. 27 kg
Optional: with pole
bracket

Legend:

Control call station DTA-xxx


Level crossing call station Level crossing call station
Operator Traffic supervisor, barrier attendant, porter,
User Passer-by
Variation 1 Operation on non-isolated lines:
Operating voltage of 48 V must be supplied
locally.
Variation 2 Operation on isolated lines:
Remote supply of the 48 V over DVS-21 possible.

Date: 16.03.2009 Page: 7/7 Author: HS Document no.: DB_WPS-01_1301_01


2008 ProCom, All rights and technical changes reserved