You are on page 1of 2

0197

FO R ADV ANCE D TRE ATME NT

DIA-BURS

8-3 KIYOHARA INDUSTRIAL PARK, UTSUNOMIYA, TOCHIGI, 321-3231 JAPAN


Phone 81-28-667-8592 Facsimile 81-28-667-8596
E-mail dental.exp@ms.mani.co.jp URL http://www.mani.co.jp
R

DIA-BURS
Designed with micro processing technology FOR F.G.

I S I S I S I S I S I S I S I S I S I S I S I S I S I S I S I S I S I S I S I S I S I S I S I S
/ / / / / / / / / / / / / / / / / / / / / / / /

TF11 TF12 TF13 TF14 TF20 TF21 TF22 TF23 TF31 TF41 TF42 TF43 FO54C SF12C BR31C SI47C WR13C TF12F TF21F TR11F TR13F TR21F TR25F TR26F

TF Series F Series

I S I S I S I S I S I S I S I S I S I S I S I S I S I S I S I S I S I S I S I S I S I S I S I S
/ / / / / / / / / / / / / / / / / / / / / / / /

TR11 TR12 TR13 TR14 TR15 TR19 TR20 TR21 TR24 TR25 TR26 TC11 TC11F TC21F FO21F FO22F EX18F EX21F BR48F WR31F WRS31F TF12EF TF21EF TR11EF

TR Series TC Series EF Series

I S I S I S I S I S I S I S I S I S I S I S I S I S I S I S I S I S I S I S I S I S I S I S I S
/ / / / / / / / / / 1/ / / / / / / / / / / / / /

TC21 TC26 FO11 FO21 FO22 FO25 FO27 FO32 SF11 SF12 SF13 SF21 TR13EF TR21EF TR25EF TR26EF TC11EF TC21EF FO21EF FO22EF EX21EF CR11F CR11EF CR12F

FO Series SF Series CR Inlay Preparation Series

I S I S I S I S I S I S I S I S I S I S I S I S I S I S I S I S I S I S I S I S I S I S I S
/ / / / / / / / / / / / / / / / / / / / / / /

SF31 SF41 SO20 SO21 SR11 SR12 SR13 RS11 RS21 RS31 EX11 CR12EF CR21F CR22F FO30F FO20EF FO40EF FO41EF FO42EF BR40EF CD50F CD51F CD52F

SO Series SR Series RS Series EX Series CR Polishing Series CD Series


How to see this chart
Max. allowable r.p.m.
I S I S I S I S I S I S I S I S I S I S I S I S I S I S I S I S I S I S I S
/ / / / / / / / / / / / / / / / / / / 450,000r.p.m. 300,000r.p.m. 160,000r.p.m.
Color coding
EX12 EX20 EX21 EX24 EX26 EX31 EX41 BR31 BR40 BR41 BR45 BR46 CD53F CD54F CD55F CD56F CD57F CD58F CD59F
Coarse/125-150m Standard/106-125m
I S
BR Series / F i n e / 5 3 - 6 3m Extra Fine/20-30m

TF11 ISO No.


Color Coding
Order No.
Color code indication is provided at the end of working part ( ), according to the size of TF Series
I S I S I S I S I S I S I S I S I S I S I S I S diamond grit conforming to the specification. Shape
/ / / / / / / / / / / /

Classification
BR49 BC31 BC42 BC43 DI41 DI42 SI46 SI47 SI48 WR13 TFS20 TFS21 MANI coding system reflects shapes of burs. The contour and sizes could be imagined by MANI nomenclature since ISO numbers are also indicated.
TF/Taper Flat EndTR/Taper Round EndTC/Taper Conical EndFO/Flame Ogival EndSF/Straight Flat EndSO/Straight Ogival End
BC Series DI Series SI Series WR Series S Series SR/Straight Round EndRS/Rounded ShoulderEX/Special (Extra) ShapeBR/Ball Round TypeBC/Ball Collar TypeDI/Double Inverted Cone
SI/Single Inverted ConeWR/Wheel Round EdgeCR/CR Inlay Preparation Dia-BursCD/Children's Dentistry Dia-Burs
S/Short ShankSS/Super Short ShankC/CoarseF/FineEF/Extra Fine

I S I S I S I S I S I S I S I S I S I S I S I S High Quality Control


/ / / / / / / / / / / / Laser measurement cutting test and strength test for each lot are performed. All products comply with our own standards which are far more strict than ISO standards.

TFS22 TFS23 TFS31 TFS41 TRS13 TRS21 TCS21 FOS21 SOS20 BRS45 BRS46 BCS42 Before using MANI DIA-BURS, please see the instruction as indicated below.
For dental use only. Non-sterile. Insert the shank into the handpiece according to the instruction of the handpiece manufacturer.Insertion should be the full length. Before
use, run the instruments to make sure there is no descentering. If the instruments become bent, be sure to remove them from any further use. Please always use spray. A
Plentiful water supply is necessary to maintain long-lived performance and also to prevent loading and pulpitis. Handle with care not to put excessive load. Pressure should be
20 to 50p for all instruments with diameter up to 023. Use below max. allowable r.p.m. of each instrument, see chart above, to avoid a possibility of being injured due to
I S I S I S I S I S I S I S I S I S I S I S I S breakage.Avoid levering, tilting, twisting and jamming motion. Do not work with a pulling motion. Wear a safety glasses and/or facemask to protect from being injured.
/ / / / / / / / / / / / Practicable for using auto-clave. Do not use high pressure steam sterilizer which heats more than 200 including drying process. After using, follow appropriate treatment as the
medical waste.
BCS43 DIS41 SIS46 SIS48 TFSS31 TRSS21 DISS41 TF13C TR13C TR62C TC11C FO32C

SS Series C Series All rights reserved. The instruments are subject to change.We reserve the right to modify our range of instruments and their design as well as to deviate from the illustrations and data shown.D 01620