EXAMPLE 7

(Insulating and Electrical Wire and Critical Radius)


Given; EXAMPLE 7 - SOLUTION
D1 = 1.5 mm
Plastic insulation thickness = 2.5 mm
To = 300 K
ho = 20 W/m2. K
k = 0.4 W/m. K (for the insulation)
T2 = surface wire temp = 400 K
Solution;
.
For part (a), using Equation; = = = . =

For part (b), = . , = . = . , = .


Subtituting into the following equation;
q= = . = .

For part (c), with insulation, , = . = . , =


.
.+
= . . Substituting into the following equation;

(.)()
= . / .
= .

+
.
Hence, adding insulation greatly increases the heat loss.