MODEL Siemens SOMATOM Definition

CONFIGURATION OPTIONS
Number of slices 64 slice
CT scanner mode (CONFIGURATION
Cardiac
OPTIONS)
CT angiography package
Included standard
(CONFIGURATION OPTIONS)
3D Image processing and display package
Included standard
(CONFIGURATION OPTIONS)
Volume CT, Dynamics CT, VRT, InSpace 4D, LungCare & NEV, Colon &
Additional clinical applications PEV, Dental CT, Calcium Scor., Fly Through, Osteo CT, Pulmo CT, Neuro
(CONFIGURATION OPTIONS) Perf., Body Perf., Fusion, Neuro DSA, Circulation, InSpace Advanced Vessel
Analysis, Dual Energy, Dual Power scanning
CT simulation package
Optional
(CONFIGURATION OPTIONS)
UPS Provided (CONFIGURATION
Yes, standard
OPTIONS)
TECHNICAL SPECIFICATIONS
Image reconstruction time - 2D [Seconds]
Up to 40 slices/second seconds seconds
(TECHNICAL SPECIFICATIONS)
FOV (Min, Max) (TECHNICAL
78 cm
SPECIFICATIONS)
Automated dosage control (TECHNICAL
Yes
SPECIFICATIONS)
High contrast spatial resolution at 0% MTF
30 lp/cm
(TECHNICAL SPECIFICATIONS)
High contrast spatial resolution at 50%
15 lp/cm
MTF (TECHNICAL SPECIFICATIONS)
Rotation Speed Range (TECHNICAL
0.33 Min sec. - Max sec. per rotation, increments
SPECIFICATIONS)
X-Ray generator kVp range 80, 100, 120, 140
Gantry diameter (TECHNICAL
78 cm
SPECIFICATIONS)
On-line image storage capacity
260000 Images
(TECHNICAL SPECIFICATIONS)
Table movement range cm, vertically /
longitudinally (TECHNICAL 48-92 cm / 200 cm
SPECIFICATIONS)
Table scanning range (TECHNICAL
200 cm
SPECIFICATIONS)
Table weight limit [lbs] (TECHNICAL
485
SPECIFICATIONS)
Minimum room size requirements (Length x
Width x Height) (TECHNICAL 30 square meter
SPECIFICATIONS)
Power requirements (VAC, Amps) 250 kVA
INTERFACE CAPABILITY AND
SPECIFICATION
DICOM query/retrieve class user/provider
(INTERFACE CAPABILITY AND Yes
SPECIFICATION)
DICOM storage class user/provider Yes
DICOM storage commit compliant
(INTERFACE CAPABILITY AND Yes
SPECIFICATION)
DICOM print class user/provider
(INTERFACE CAPABILITY AND Yes
SPECIFICATION)
MODEL Siemens SOMATOM Definition
PERFORMANCE
0% mtf, lp/cm (High-contrast spatial
30
resolution)
50% mtf, lp/cm (PERFORMANCE) 15
Slice sensitivity profile
Low-contrast resolution, mm at % at
20 mGy (2 rads) (Slice sensitivity 5 mm at 3 HU
profile)
Noise, % at 25 mGy (2.5 rads)
2.1 HU
(Slice sensitivity profile)
Type (CONFIGURATION) Multislice
# of slices (X-ray tube anode) Dual source technology
GENERATOR
kW output (GENERATOR) 2 x 80
Kvp range (GENERATOR) 80, 100, 120, 140
Ma range (IMAGING SYSTEM) 28(single source); 28-1,330 (dual source)
CLINICAL APPLICATIONS AND
FUNCTIONALITY
Coronary artery calcification scoring
(CLINICAL APPLICATIONS AND Yes
FUNCTIONALITY)
Quantification (CLINICAL
APPLICATIONS AND Optional
FUNCTIONALITY)
Lung nodule assisted reading (Myocardial
Optional
evaluation)
Respiratory gating (DISPLAY) Optional
Virtual colonoscopy assisted reading
Optional
(Myocardial evaluation)
Other (ROTORS) Optional all cardiac, pulmonary, vasculature
X-RAY TUBE
Heat storage, MHU (X-RAY TUBE) 0.6 MHU with 5 MHU/min heat dissipation
Heat dissipation rate, kHU/min (X-RAY
5000
TUBE)
Tube cooling (X-ray tube anode) Chilled water
Tube focal spots, mm (X-RAY TUBE) 0.6 x 0.6, 0.8 x 0.9
Maximum ma (X-ray tube anode) 28-665 (single source); 28-1,330 (dual source)
TABLE FEATURES
Range of movement
Vertical, cm (Range of movement) 48-92
Longitudinal, cm (Range of movement) 200
Scanning range,cm (Range of movement) 200
Max load capacity (accuracy, mm), without
220 (not specified)
restrictions, kg (Range of movement)
POWER NEEDED 380-480 VAC, 3-phase
GANTRY
Gantry angle deg (GANTRY) 30
Gantry size, hxwxd,cm (GANTRY) 198 x 117 x 231.4
Gantry weight, kg (GANTRY) 2700
Gantry opening, cm (GANTRY) 70
Scan localizer (GANTRY) Laser
DICOM (GANTRY) Yes
IMAGE RECONSTRUCTION
Cpu (NETWORK/DATABASE) 2 x Xeon 3.6 GHz processor
Scan fovs, cm (IMAGE PROCESSING) 50; optional 70, 78
Reconstruction matrices (IMAGE
512 x 512
RECONSTRUCTION)
Per slice, sec (Reconstruction time) Up to 25 images/sec
No. of online images (IMAGE STORAGE) 260,000 (512 x 512)
Archive (IMAGE STORAGE) CD-R, optional MOD
IMAGE PROCESSING (MAXIMUM
DISPLAY)
Standard or optional (IMAGE
Standard
PROCESSING)
Dicom 3-d image export (IMAGE
Yes
PROCESSING)
DETECTOR (SCATTERED LIGHT)
Total detector width, z-axis, mm
28.8
(DETECTOR)
Reconstructed slice width options, mm
0.6, 0.75, 1, 1.5, 2, 3, 4, 5, 6, 9, 10
(GANTRY)
Standard Rotation times, sec, 360
0.33, 0.37, 0.42, 0.5, 0.75, 1, 1.5
(DETECTOR)
SureView; CARE Dose 4-D; CARE Vision; CARE Bolus; syngo InSpace4-D;
OTHER ATTRIBUTES (Interference syngo Fly Through; syngo Dental; syngo Osteo; syngo Pulmo; HeartView;
compensation) syngo Circulation; syngo InSpace4-D Advanced Vessel Analysis; syngo
Calcium Scoring; syngo Neuro Perfusion; syngo Bod
FDA CLEARANCE (Interference
Yes
compensation)
CE MARK (MDD) (Interference
Yes
compensation)
MARKETING REGION (Interference
World
compensation)