SIEMENS
Releases
This document concerns the serial connection ("F" interface) to hiT 7070 and 7050 releases
1.02
1.1
2.0
NOTE: Release 1.0 of hiT 7050 does not provide "F" interface support.
Symptoms
In some cases it is not possible to connect from TNMS-CT 2.0 or higher to Surpass hiT
7070/7050 using the serial line.
Problem Description
Workaround
Use a serial "null-modem" cable that has only pins 2 and 3 (RX and TX) connected (cross), and
pin 5 for ground.
All other pins are not connected, as shown in the diagram below:
1 2 3 4 5 9 8 7 6
6 7 8 9 5 4 3 2 1
Pin Pin
1 ------------ 1
2 ------------ 3
3 ------------ 2
4 ------------ 4
5 ------------ 5
6 ------------ 6
7 ------------ 7
8 ------------ 8
Authorized
02 13.04.04 Conti/Brunner Name: Mr. Gerhards Serial Connection
01 17.12.03 A.Conti ICN CP STS NP J HiT 7050
Issue Modif. Date Name Page
Note
SIEMENS AG TNMS-CT 2.0 2/14
Information and Communication Networks
Document: 201862007.doc All rights reserved
SIEMENS
This means, pins 2 and 3 are connected crossed, other pins are connected straight. Pin 9 is not
used.
The connections are shown in the diagram below.
1 2 3 4 5 9 8 7 6
6 7 8 9 5 3
4 2 1
There have also been successful tests for serial connection to hiT using a commercial "Lindy"
brand cable.
The ordering number from Lindy for this cable is 31578.
Pin Pin
1/6/8 ------------ 7
2 ------------ 3
3 ------------ 2
5 ------------ 5
7 ------------ 1/6/8
Pins 4 and 9 are not connected. The connections are shown in the diagram below:
1 2 3 4 5 9 8 6
7
6 7 8 9 5 4 3 2 1
Authorized
02 13.04.04 Conti/Brunner Name: Mr. Gerhards Serial Connection
01 17.12.03 A.Conti ICN CP STS NP J HiT 7050
Issue Modif. Date Name Page
Note
SIEMENS AG TNMS-CT 2.0 3/14
Information and Communication Networks
Document: 201862007.doc All rights reserved
SIEMENS
Attached the procedure extracted from the TNMS-CT V1.0 User Manual (UMN) Chapter 3.6.1.
chapter361.doc
If the serial connection in TNMS-CT is already set, check that it is properly configured by
comparing the settings shown in the user manual in point 7 of chapter 3.6.1 (see the
screenshots in the document attached above).
If the serial connection does not work (fails when trying to connect), it is also recommendable to
check the following:
1. MPU-F properties:
Register General
Authorized
02 13.04.04 Conti/Brunner Name: Mr. Gerhards Serial Connection
01 17.12.03 A.Conti ICN CP STS NP J HiT 7050
Issue Modif. Date Name Page
Note
SIEMENS AG TNMS-CT 2.0 4/14
Information and Communication Networks
SIEMENS
Register "Options"
Authorized
02 13.04.04 Conti/Brunner Name: Mr. Gerhards Serial Connection
01 17.12.03 A.Conti ICN CP STS NP J HiT 7050
Issue Modif. Date Name Page
Note
SIEMENS AG TNMS-CT 2.0 5/14
Information and Communication Networks
SIEMENS
Register "Security"
Authorized
02 13.04.04 Conti/Brunner Name: Mr. Gerhards Serial Connection
01 17.12.03 A.Conti ICN CP STS NP J HiT 7050
Issue Modif. Date Name Page
Note
SIEMENS AG TNMS-CT 2.0 6/14
Information and Communication Networks
SIEMENS
Register: Networking
PPP-Settings:
Authorized
02 13.04.04 Conti/Brunner Name: Mr. Gerhards Serial Connection
01 17.12.03 A.Conti ICN CP STS NP J HiT 7050
Issue Modif. Date Name Page
Note
SIEMENS AG TNMS-CT 2.0 7/14
Information and Communication Networks
SIEMENS
TCP/IP-properties:
Authorized
02 13.04.04 Conti/Brunner Name: Mr. Gerhards Serial Connection
01 17.12.03 A.Conti ICN CP STS NP J HiT 7050
Issue Modif. Date Name Page
Note
SIEMENS AG TNMS-CT 2.0 8/14
Information and Communication Networks
SIEMENS
notice the "Local IP Address" must be 127.0.0.1 for the serial connection to work.
Authorized
02 13.04.04 Conti/Brunner Name: Mr. Gerhards Serial Connection
01 17.12.03 A.Conti ICN CP STS NP J HiT 7050
Issue Modif. Date Name Page
Note
SIEMENS AG TNMS-CT 2.0 9/14
Information and Communication Networks
SIEMENS
In this window the first item is the Serial Line Server. Clicking on the server icon displays the
four Serial Line Server Channels that are available in TNMS-CT.
hiT 7070 and 7050 are QST V2 Network Elements.
Here the NE ("QST V2 Serial Line NE") must exist under the QST V2 Serial Line Channel, as
shown in the figure above.
Authorized
02 13.04.04 Conti/Brunner Name: Mr. Gerhards Serial Connection
01 17.12.03 A.Conti ICN CP STS NP J HiT 7050
Issue Modif. Date Name Page
Note
SIEMENS AG TNMS-CT 2.0 10/14
Information and Communication Networks
SIEMENS
Settings QST V2 Serial Channel:
Authorized
02 13.04.04 Conti/Brunner Name: Mr. Gerhards Serial Connection
01 17.12.03 A.Conti ICN CP STS NP J HiT 7050
Issue Modif. Date Name Page
Note
SIEMENS AG TNMS-CT 2.0 11/14
Information and Communication Networks
SIEMENS
The NE must have the following properties (click on the item "QST V2 Serial Line NE" with the
right-hand mouse button and select the item "Properties")
Authorized
02 13.04.04 Conti/Brunner Name: Mr. Gerhards Serial Connection
01 17.12.03 A.Conti ICN CP STS NP J HiT 7050
Issue Modif. Date Name Page
Note
SIEMENS AG TNMS-CT 2.0 12/14
Information and Communication Networks
SIEMENS
Register: General
The ID Name need not be changed. It is not mandatory to add any data in this window.
Register: Security
For serial connection with TNMS-CT the following data must be entered
User: LCT
Password : "NEPASSWORD" (all capital letters)
Authorized
02 13.04.04 Conti/Brunner Name: Mr. Gerhards Serial Connection
01 17.12.03 A.Conti ICN CP STS NP J HiT 7050
Issue Modif. Date Name Page
Note
SIEMENS AG TNMS-CT 2.0 13/14
Information and Communication Networks
SIEMENS
Register: QST
Successful connection
After a successful connection the DCN management must show the NE under the " QST V2
Serial Line Channel" in status "running" (see DCN Management window above). In the Network
View the NE must also be shown with a green icon, as shown in the figure below:
Clicking on the icon with the right-hand mouse button open the Element Manager for operation.
Authorized
02 13.04.04 Conti/Brunner Name: Mr. Gerhards Serial Connection
01 17.12.03 A.Conti ICN CP STS NP J HiT 7050
Issue Modif. Date Name Page
Note
SIEMENS AG TNMS-CT 2.0 14/14
Information and Communication Networks