This document concerns the serial connection ("F" interface) to hiT 7070 and 7050 releases
1.02
1.1
2.0
NOTE: Release 1.0 of hiT 7050 does not provide "F" interface support.

Symptoms
In some cases it is not possible to connect from TNMS-CT 2.0 or higher to Surpass hiT
7070/7050 using the serial line.

Problem Description

Surpass 7050 serial cable


The serial cable used to connect to Surpass hiT 7050 must have a particular pin assignment.
Some commercially available "null-modem" cables will work and others will not work, depending
on the pin connection of the cable.

Workaround
Use a serial "null-modem" cable that has only pins 2 and 3 (RX and TX) connected (cross), and
pin 5 for ground.
All other pins are not connected, as shown in the diagram below:

1 2 3 4 5 9 8 7 6

6 7 8 9 5 4 3 2 1

DB-9 female DB-9 female


view of the soldering side view of the soldering side

Ordering number for Siemens cable


There is a Siemens code for the "official" cable for hiT 7050.
V42256-R703-A18-1 TPY R0
This cable has the following connections:

Pin Pin
1 ------------ 1
2 ------------ 3
3 ------------ 2
4 ------------ 4
5 ------------ 5
6 ------------ 6
7 ------------ 7
8 ------------ 8

Authorized
02 13.04.04 Conti/Brunner Name: Mr. Gerhards Serial Connection
01 17.12.03 A.Conti ICN CP STS NP J HiT 7050
Issue Modif. Date Name Page
Note
SIEMENS AG TNMS-CT 2.0 2/14
Information and Communication Networks
Document: 201862007.doc All rights reserved
SIEMENS
This means, pins 2 and 3 are connected crossed, other pins are connected straight. Pin 9 is not
used.
The connections are shown in the diagram below.

1 2 3 4 5 9 8 7 6

6 7 8 9 5 3
4 2 1

view of the soldering side view of the soldering side

hiT 7070/ 7050


Ordering number for Lindy cable

There have also been successful tests for serial connection to hiT using a commercial "Lindy"
brand cable.
The ordering number from Lindy for this cable is 31578.

Pin Pin
1/6/8 ------------ 7
2 ------------ 3
3 ------------ 2
5 ------------ 5
7 ------------ 1/6/8
Pins 4 and 9 are not connected. The connections are shown in the diagram below:

1 2 3 4 5 9 8 6
7
6 7 8 9 5 4 3 2 1

DB-9 female DB-9 female


view of the soldering side view of the soldering side

More information available under http://www.lindy.com.


Using this cable we have successfully tested the "F" interface connection to hiT 7070 as well as
7050.

Authorized
02 13.04.04 Conti/Brunner Name: Mr. Gerhards Serial Connection
01 17.12.03 A.Conti ICN CP STS NP J HiT 7050
Issue Modif. Date Name Page
Note
SIEMENS AG TNMS-CT 2.0 3/14
Information and Communication Networks
Document: 201862007.doc All rights reserved
SIEMENS

Appendix: Setting up the serial connection.

Procedure from User Manual

Attached the procedure extracted from the TNMS-CT V1.0 User Manual (UMN) Chapter 3.6.1.

chapter361.doc

If the serial connection in TNMS-CT is already set, check that it is properly configured by
comparing the settings shown in the user manual in point 7 of chapter 3.6.1 (see the
screenshots in the document attached above).

If the serial connection does not work (fails when trying to connect), it is also recommendable to
check the following:

1. MPU-F properties:

Register General

Authorized
02 13.04.04 Conti/Brunner Name: Mr. Gerhards Serial Connection
01 17.12.03 A.Conti ICN CP STS NP J HiT 7050
Issue Modif. Date Name Page
Note
SIEMENS AG TNMS-CT 2.0 4/14
Information and Communication Networks
SIEMENS

Register "Options"

Authorized
02 13.04.04 Conti/Brunner Name: Mr. Gerhards Serial Connection
01 17.12.03 A.Conti ICN CP STS NP J HiT 7050
Issue Modif. Date Name Page
Note
SIEMENS AG TNMS-CT 2.0 5/14
Information and Communication Networks
SIEMENS

Register "Security"

Authorized
02 13.04.04 Conti/Brunner Name: Mr. Gerhards Serial Connection
01 17.12.03 A.Conti ICN CP STS NP J HiT 7050
Issue Modif. Date Name Page
Note
SIEMENS AG TNMS-CT 2.0 6/14
Information and Communication Networks
SIEMENS

Register: Networking

PPP-Settings:

Authorized
02 13.04.04 Conti/Brunner Name: Mr. Gerhards Serial Connection
01 17.12.03 A.Conti ICN CP STS NP J HiT 7050
Issue Modif. Date Name Page
Note
SIEMENS AG TNMS-CT 2.0 7/14
Information and Communication Networks
SIEMENS

TCP/IP-properties:

Authorized
02 13.04.04 Conti/Brunner Name: Mr. Gerhards Serial Connection
01 17.12.03 A.Conti ICN CP STS NP J HiT 7050
Issue Modif. Date Name Page
Note
SIEMENS AG TNMS-CT 2.0 8/14
Information and Communication Networks
SIEMENS

2. OSI Protocol settings in TNMS-CT

notice the "Local IP Address" must be 127.0.0.1 for the serial connection to work.

Authorized
02 13.04.04 Conti/Brunner Name: Mr. Gerhards Serial Connection
01 17.12.03 A.Conti ICN CP STS NP J HiT 7050
Issue Modif. Date Name Page
Note
SIEMENS AG TNMS-CT 2.0 9/14
Information and Communication Networks
SIEMENS

3. DCN Management in TNMS-CT

From the main TNMS-CT menu choose

Configuration -> DCN management

In this window the first item is the Serial Line Server. Clicking on the server icon displays the
four Serial Line Server Channels that are available in TNMS-CT.
hiT 7070 and 7050 are QST V2 Network Elements.

Here the NE ("QST V2 Serial Line NE") must exist under the QST V2 Serial Line Channel, as
shown in the figure above.

Authorized
02 13.04.04 Conti/Brunner Name: Mr. Gerhards Serial Connection
01 17.12.03 A.Conti ICN CP STS NP J HiT 7050
Issue Modif. Date Name Page
Note
SIEMENS AG TNMS-CT 2.0 10/14
Information and Communication Networks
SIEMENS
Settings QST V2 Serial Channel:

Authorized
02 13.04.04 Conti/Brunner Name: Mr. Gerhards Serial Connection
01 17.12.03 A.Conti ICN CP STS NP J HiT 7050
Issue Modif. Date Name Page
Note
SIEMENS AG TNMS-CT 2.0 11/14
Information and Communication Networks
SIEMENS

The NE must have the following properties (click on the item "QST V2 Serial Line NE" with the
right-hand mouse button and select the item "Properties")

Authorized
02 13.04.04 Conti/Brunner Name: Mr. Gerhards Serial Connection
01 17.12.03 A.Conti ICN CP STS NP J HiT 7050
Issue Modif. Date Name Page
Note
SIEMENS AG TNMS-CT 2.0 12/14
Information and Communication Networks
SIEMENS

Register: General

The ID Name need not be changed. It is not mandatory to add any data in this window.

Register: Security

For serial connection with TNMS-CT the following data must be entered

User: LCT
Password : "NEPASSWORD" (all capital letters)

Authorized
02 13.04.04 Conti/Brunner Name: Mr. Gerhards Serial Connection
01 17.12.03 A.Conti ICN CP STS NP J HiT 7050
Issue Modif. Date Name Page
Note
SIEMENS AG TNMS-CT 2.0 13/14
Information and Communication Networks
SIEMENS

Register: QST

IP Address must be 195.0.0.1


T-Selector must be QST

After this press "Apply" to make the changes permanent.

Successful connection

After a successful connection the DCN management must show the NE under the " QST V2
Serial Line Channel" in status "running" (see DCN Management window above). In the Network
View the NE must also be shown with a green icon, as shown in the figure below:

Clicking on the icon with the right-hand mouse button open the Element Manager for operation.

Authorized
02 13.04.04 Conti/Brunner Name: Mr. Gerhards Serial Connection
01 17.12.03 A.Conti ICN CP STS NP J HiT 7050
Issue Modif. Date Name Page
Note
SIEMENS AG TNMS-CT 2.0 14/14