SUBMITTAL TRANSMITTAL
TO: City of Oakland Date: October 26, 2015
250 Frank H Ogawa Plaza, Ste 4314
Oakland, CA 94612 Job No.: OAK05 Submittal #: 13.0

Attn: Wezlon Miles


Tel: (510) 238-5238 Project: SS Rehab of 17th, 21st, 27th St, Inyo St, & 25th Ave
Fax: (510) 238-6633 Subject: Concrete- Curb, Gutter, Sidewalk

Gentlemen,

We are enclosing the following submittal information for review and approval in accordance with the contract
documents. Please return two (2) approved/marked sets for our records.

No. Copies Ref Spec/Dwg Description Source


1 1 303-5 Concrete- Curb, Gutter, Sidewalk RightAway

Notes: Review Action (check one):


[ ] 1 -No Exceptions Noted
[ ] 2 -Make Corections Noted
[ ] 3 -Revise & Resubmit
[ ] 4 -Not Acceptable -Resubmit

PLEASE DIRECT ANY QUESTIONS REGARDING THIS SUBMITTAL TO:


Ron H. Zelaya, P.E.
Phone (510) 303-9591
ronzelaya@sbcglobal.net

Cc: J. HOWARD ENGINEERING

By: R. Zelaya
RIGHT AWAY REDY MIX, INC.
RIGHT AWAY CONCRETE PUMPING, INC.
Q 401 Kennedy Street Oakland. CA 94606 (BOO) 696-0515 (510) 536-1900 FAX (510) 261
Q 30100 Union City Blvd Union City. CA 94587 (510) 489-0515 FAX (510) 489-1401
d 5501 Imhoff Drive Martinez. CA 94553 (925) 882-1700 FAX (925) 682-1903
Q 501B El Charro Road Pleasanton. CA 94588 (025) 443-2300 FAX (925) 443-2355

MIX DESIGN NUMBER 133 DATE


MIX DESCRIPTION 5SK3/4(1700#2800PSI)

CONTRACTOR JOB NAME:


J. HOWARD ENGINEERING VARIOUS SITES
ATTN: RON ZELAYA
MATERIAL ABS VOL SSD WEIGHTS
28 DAY STRENGTH 2800 PSI
3/4" X #4 10.13 1700
W/C RATIO 0.649 REG TOP SAND 6.43 1071
SR BLEND SAND 2.75 446
CEMENT : ASTM C-150 TYPE II
CEMENT SACKS 5.00 CEMENT 2.39 470

SLUMP 4" WATER: 37 GALS 4.89 305


WRDA : ASTM C-494 TYPE A ADMIX : 3.0 oz/cwt 0.41 14.1 fl. oz.
LAMPBLACK: If needed ADMIX :16.0 oz/yd 1 Ib

MAX. SIZE AGGREGATE 3/4" TOTALS 27.00 3992

TYPICAL ANALYSIS % PASSING U.S. STD. SIEVES AS AVERAGE GRADING BY SUPPLIER

SIEVE SP. GR. COMMENTS: This mix is designed for manual or


boom placement. The Type A water reducer is
3/4" X #4 2.69 WRDA 64, by W.R. Grace. This is the Oakland
REG TOP SAND 2.67 sidewalk concrete mix and lampblack must be
SR BLEND SAND 2.60 ordered each time as it is not integral to this mix.

NOTE: THE ABOVE MIX IS BASED ON THE CONSIDERATION THAT THE COMPRESSiVE
STRENGTH RESULTS WILL EQUAL OR EXCEED THE STRENGTH SHOWN ABOVE WHEN
CYLINDERS ARE CURED IN ACCORDANCE WITH ASTM C-31. IF SPECIMENS ARE NOT
SAMPLED, MADE, HANDLED. CURED. TESTED IN ACCORDANCE WITH APPLICABLE
ASTM STANDARD PROCEDURES, OR IF THE SLUMP OR W/C RATIO ARE EXCEEDED,
THIS MIX AS SHOWN ABOVE CANNOT BE EXPECTED TO PRODUCE THE DESIRED
PROPERTIES.
RIGHT AWAY REDY MIX INC.