You are on page 1of 31

DOTec Corp.

Customized Engineering Solutions

STRUCTURAL CALCULATIONS
PROJECT NO.: #2311155
CLIENT: Fluid Solutions
PROJECT INFORMATION
SCOPE OF WORK: Foundation design

BILLING ADDRESS:
ADDRESS:
CITY:
STATE:
ZIP:
COUNTRY:

CLINT CONTACT INFO


CONTACT:
TEL:
FAX:
MOBILE:
E-MAIL:

SITE ADDRESS:
SEAL:
ADDRESS: 5098 Highway 411

CITY: Kingston

STATE: Georgia

ZIP: 30145

CONFIRM ZIP: 30145

COUNTRY: USA

REVISION HISTORY
# DATE DESCRIPTION PREPARED BY CHECKED BY
01 12/12/2023 First Submital MH AG
02
03
REFERENCES: IBC 2018 amended, ASCE 7-16, ACI 318, ACI 360
Acceptance and use of this report by any party constitute a contractual agreement that the Engineers total liability arising out of or in any way related to this analysis and report
shall not exceed the total sum paid to the Engineer for the services provided. Liability does not exist beyond the analysis contained in this report.
S001V002
Copyright. Dotec Engineering
424 Jeffereson St., St. Charles, MO 63301. Phone: (636) 724-9872

1
CONTENTS

CONTENTS 2

LOADS 3

DESIGN 6

2
DOTec Corp.

Loads

D1 ≔ 72 ft

P1 ≔ π ⋅ D1 = 226.195 ft

π ⋅ D1 2
A1 ≔ ――― = ⎛⎝4.072 ⋅ 10 3 ⎞⎠ ft 2
4

D2 ≔ 75 ft

P2 ≔ π ⋅ D2 = 235.619 ft

π ⋅ D2 2
A2 ≔ ――― = ⎛⎝4.418 ⋅ 10 3 ⎞⎠ ft 2
4

3
DOTec Corp.

Dead Loads

DL1 ≔ 814 plf Shell load

DL2 ≔ 10.2 psf Base load

DL3 ≔ “Base Self Wt.” Base load

DL4 ≔ 25.1 kip Central column load

Snow Loads

Snow ≔ 0

Roof live Loads

RLL1 ≔ 252 plf Shell load

RLL2 ≔ 20.36 kip Central column load

Fluid Loads

FL_loads ≔ 3309 psf Base load

Wind Loads

V ≔ 215.2 plf Horizontal Shell load

3 ⋅ π ⋅ D1 2 Shell modulus
Sshell ≔ ―――― = ⎛⎝3.054 ⋅ 10 3 ⎞⎠ ft 2
16

877.152 kip ⋅ ft ⋅ 1.6


Nmax ≔ ――――――― = 459.599 plf Max. Vertical shell load
Sshell

4
DOTec Corp.

EQ Loads

V ≔ 4325 plf Horizontal Shell load

17421 kip ⋅ ft ⎛
Nmax ≔ ――――― = ⎝5.705 ⋅ 10 3 ⎞⎠ plf Max. Vertical shell load
Sshell

π ⋅ D1 3
Sbase.inner ≔ ――― = ⎛⎝3.664 ⋅ 10 4 ⎞⎠ ft 3
32

26591.4 kip ⋅ ft
Pmax ≔ ―――――= 725.678 psf Max. Vertical Area load
Sbase.inner

Sds ≔ 0.3058

Sd1 ≔ 0.1705

Importance category = II

Seismic design category = C

5
DOTec Corp.

Design of 18" Pile

1) Check piles for Ultimate Axial loads only based on Concrete capacity

ϕ ≔ 0.55 fc ≔ 4 ksi fy ≔ 60 ksi

D ≔ 18 in Lp ≔ 42 ft

As ≔ 10 ⋅ 0.44 in 2 = 4.4 in 2 (10) #6 longitudinal rebars


6 π ⋅ D2
db ≔ ―in Ag ≔ ――― = 254.469 in 2
8 4

6
DOTec Corp.

Ac ≔ Ag - As = 250.069 in 2

Po ≔ 0.8 ⋅ ⎛⎝0.85 ⋅ fc ⋅ Ag + fy ⋅ As⎞⎠ = 903.356 kip ϕPc ≔ ϕ ⋅ 0.8 ⋅ ⎛⎝0.85 ⋅ fc ⋅ Ag⎞⎠ = 380.686 kip

ϕPn ≔ ϕ ⋅ Po = 496.846 kip


2 ksf
Pu ≔ 455 kip Pu - 1.4 ⋅ ――⋅ π ⋅ D ⋅ 12 ft = 375.832 kip
2
As.min ≔ 0.0025 ⋅ Ag = 0.636 in 2 Minimum longitudinal rebars ACI318 Table 18.13.5.7.1

if ⎛⎝As > As.min , “Safe” , “UNSAFE”⎞⎠ = “Safe”

if ⎛⎝Pu ≤ ϕPn , “Safe” , “UNSAFE”⎞⎠ = “Safe”

2) Check piles for Tension

There is no tension

7
DOTec Corp.

3) Check piles for unfactored Axial loads based on Soil capacity in service

Pw ≔ 326 kip

Pall ≔ 334 kip

if ⎛⎝Pw ≤ Pall , “Safe” , “UNSAFE”⎞⎠ = “Safe”

8
DOTec Corp.

4) Check piles for Horizontal Loads

cu ≔ 2000 psf Ph.n ≔ 9 ⋅ cu ⋅ D = 27 klf R ≔ 0.65

ε50 ≔ 0.007 Ph.n ⋅ 1 ft = 27 kip

y50 ≔ 1.5 ⋅ ε50 ⋅ D = 0.016 ft

P50 ≔ 0.5 ⋅ Ph.n = 13.5 klf


P50
Slope ≔ ―― ⋅ 0.65 = 557.143 ksf
y50
kip
Slope ⋅ 1 ft = 46.429 ――
in
Ph ≔ 13.6 kip

9
DOTec Corp.

Ph.n ⋅ 1 ft
Clearly from seeing the reactions and comparing them to ―――― = 13.5 kip The soil is
2
very safe from failure by lateral loads on pile

10
DOTec Corp.

Δ ≔ 0.141 in

Δall ≔ 0.5 in

if ⎛⎝Δ ≤ Δall , “Safe” , “UNSAFE”⎞⎠ = “Safe”

11
DOTec Corp.

Mu ≔ 66.1 kip ⋅ ft

The pile will be checked for axial and bending using a Section design program
π ⋅ D3
S ≔ ――― = 572.555 in 3
32

‾‾‾‾
fc
Mcr ≔ S ⋅ 7.5 ⋅ ―― ⋅ psi = 22.632 kip ⋅ ft
psi

0.4 ⋅ Mcr = 9.053 kip ⋅ ft

Lflex ≔ 11.1 ft

ψt ≔ 1 ψe ≔ 1 ψg ≔ 1

12
DOTec Corp.

fy ⋅ ψt ⋅ ψe ⋅ ψg
ld ≔ ―――――⋅ db = 28.46 in
25 ⋅ ‾‾fc ⋅ ‾‾‾ psi

⎛ 1 ⎞
Lreinf ≔ max ⎜Lflex + ld , 10 ft , ―⋅ Lp , 3 ⋅ D⎟ = 14 ft Reinforced length ACI318 Table 18.13.5.7.1
⎝ 3 ⎠

5) Check piles for shear strength

Vu ≔ 19.5 kip

be ≔ D ⋅ 0.88 = 15.84 in
3 3
d ≔ be - 3 in - ―in - ―in - 2 in = 10.09 in Approximately
8 8
Vc ≔ be ⋅ d ⋅ 2 ⋅ ‾‾
fc ⋅ ‾‾‾
psi = 20.217 kip

ϕVc ≔ 0.75 ⋅ Vc = 15.162 kip

Try #3 @10"

Av ≔ 0.11 in 2 ⋅ 2 = 0.22 in 2

s ≔ 10 in

A v ⋅ fy ⋅ d
Vs ≔ ―――= 13.319 kip
s
Vn ≔ Vc + Vs = 33.535 kip

ϕVn ≔ 0.75 ⋅ Vn = 25.151 kip

if ⎛⎝Vu ≤ ϕVn , “Safe” , “UNSAFE”⎞⎠ = “Safe”

min ⎛⎝8 ⋅ db , 6 in , s⎞⎠ = 6 in min ⎛⎝s , 16 ⋅ db⎞⎠ = 10 in

Use minimum ties #3 @6" in confinement zone 3 ⋅ D = 4.5 ft

Use minimum ties #3 @10" in Remainder of Reinforced length Lreinf - 3 ⋅ D = 9.5 ft

13
DOTec Corp.

6) Check piles for slenderness

Lp
―= 28
D

⎛ Lp ⎞
if ⎜― ≤ 30 , “Safe” , “UNSAFE”⎟ = “Safe”
⎝D ⎠

7) Development length in Raft

Standard hooks

fc
ψe ≔ 1 ψo ≔ 1 ψr ≔ 1.6 ψc ≔ ―――― + 0.6 = 0.863
105 MPa

fy ⋅ ψe ⋅ ψo ⋅ ψr ⋅ ψc db 1.5
Ldh ⎛⎝db⎞⎠ ≔ ―――――― ⋅ ―――
23 ⋅ ‾‾‾‾‾‾‾
fc ⋅ MPa mm 0.5

⎛6 ⎞
Ldh ⎜―in ⎟ = 15.475 in
⎝8 ⎠

14
P (kip)
1200

y
x

(Pmax)

18 in diam.

Code: ACI 318-14

Units: English

Run axis: Biaxial

Run option: Investigation

Slenderness: Not considered 1


0 180
Column type: Structural M (0°) (k-ft)
Bars: ASTM A615

Date: 12/18/23 (Pmin)


Time: 21:27:05

-400

STRUCTUREPOINT - spColumn v6.00 (TM). Licensed to: Moaaz, Moaaz. License ID: -208B1

File: C:\Users\Moaaz\Desktop\Dotec\#2311155 - Fluid Solutions\Pile 18.col


Project:
Column: Engineer:
f'c = 4 ksi fy = 60 ksi Ag = 254.469 in^2 10 #6 bars
Ec = 3605 ksi Es = 29000 ksi As = 4.40 in^2 rho = 1.73%
fc = 3.4 ksi e_yt = 0.00206897 in/in Xo = 0.00 in Ix = 5153 in^4
e_u = 0.003 in/in Yo = 0.00 in Iy = 5153 in^4
Beta1 = 0.85 Min clear spacing = 2.49 in Clear cover = 3.38 in
Confinement: Tied
phi(a) = 0.8, phi(b) = 0.9, phi(c) = 0.65

15
spColumn v6.00
Computer program for the Strength Design of Reinforced Concrete Sections
Copyright - 1988-2023, STRUCTUREPOINT, LLC.
All rights reserved

y
x

Licensee stated below acknowledges that STRUCTUREPOINT (SP) is not and cannot be responsible for either the accuracy or adequacy of the material
supplied as input for processing by the spColumn computer program. Furthermore, STRUCTUREPOINT neither makes any warranty expressed nor implied
with respect to the correctness of the output prepared by the spColumn program. Although STRUCTUREPOINT has endeavored to produce spColumn error
free the program is not and cannot be certified infallible. The final and only responsibility for analysis, design and engineering documents is the licensee's.
Accordingly, STRUCTUREPOINT disclaims all responsibility in contract, negligence or other tort for any analysis, design or engineering documents prepared
in connection with the use of the spColumn program. Licensed to: Moaaz, Moaaz. License ID: -208B1

16
STRUCTUREPOINT - spColumn v6.00 Page | 2
Licensed to: Moaaz, Moaaz. License ID: -208B1 12/18/2023
C:\Users\Moaaz\Desktop\Dotec\#2311155 - Fluid Solutions\Pile 18.col 9:28 PM

Contents
1. General Information ......................................................................................................................................... 3
2. Material Properties........................................................................................................................................... 3
2.1. Concrete ................................................................................................................................................... 3
2.2. Steel ......................................................................................................................................................... 3
3. Section............................................................................................................................................................. 3
3.1. Shape and Properties............................................................................................................................... 3
3.2. Section Figure .......................................................................................................................................... 4
4. Reinforcement ................................................................................................................................................. 4
4.1. Bar Set: ASTM A615 ................................................................................................................................ 4
4.2. Confinement and Factors ......................................................................................................................... 4
4.3. Arrangement............................................................................................................................................. 4
5. Factored Loads and Moments with Corresponding Capacities ....................................................................... 5

List of Figures
Figure 1: Column section..................................................................................................................................... 4

17
STRUCTUREPOINT - spColumn v6.00 Page | 3
Licensed to: Moaaz, Moaaz. License ID: -208B1 12/18/2023
C:\Users\Moaaz\Desktop\Dotec\#2311155 - Fluid Solutions\Pile 18.col 9:28 PM

1. General Information
File Name C:\Users\Moaaz\Desktop\Dotec\
#2311...\Pile 18.col
Project ---
Column ---
Engineer ---
Code ACI 318-14
Bar Set ASTM A615
Units English
Run Option Investigation
Run Axis Biaxial
Slenderness Not Considered
Column Type Structural

2. Material Properties
2.1. Concrete
Type Standard
f'c 4 ksi
Ec 3605 ksi
fc 3.4 ksi
εu 0.003 in/in
β1 0.85

2.2. Steel
Type Standard
fy 60 ksi
Es 29000 ksi
εyt 0.00206897 in/in

3. Section
3.1. Shape and Properties
Type Circular
Diameter 18 in
Ag 254.469 in2
Ix 5153 in4
Iy 5153 in4
rx 4.5 in
ry 4.5 in
Xo 0 in
Yo 0 in

18
STRUCTUREPOINT - spColumn v6.00 Page | 4
Licensed to: Moaaz, Moaaz. License ID: -208B1 12/18/2023
C:\Users\Moaaz\Desktop\Dotec\#2311155 - Fluid Solutions\Pile 18.col 9:28 PM

3.2. Section Figure

y
x

Circular 18 x 18 in 1.73% reinf.

Figure 1: Column section

4. Reinforcement
4.1. Bar Set: ASTM A615
Bar Diameter Area Bar Diameter Area Bar Diameter Area
in in2 in in2 in in2
#3 0.38 0.11 #4 0.50 0.20 #5 0.63 0.31
#6 0.75 0.44 #7 0.88 0.60 #8 1.00 0.79
#9 1.13 1.00 #10 1.27 1.27 #11 1.41 1.56
#14 1.69 2.25 #18 2.26 4.00

4.2. Confinement and Factors


Confinement type Tied
For #10 bars or less #3 ties
For larger bars #4 ties

Capacity Reduction Factors


Axial compression, (a) 0.8
Tension controlled ɸ, (b) 0.9
Compression controlled ɸ, (c) 0.65

4.3. Arrangement
Pattern All sides equal
Bar layout Circular
Cover to Transverse bars
Clear cover 3 in
Bars 10 #6

Total steel area, As 4.40 in2


Rho 1.73 %
Minimum clear spacing 2.49 in

19
STRUCTUREPOINT - spColumn v6.00 Page | 5
Licensed to: Moaaz, Moaaz. License ID: -208B1 12/18/2023
C:\Users\Moaaz\Desktop\Dotec\#2311155 - Fluid Solutions\Pile 18.col 9:28 PM

5. Factored Loads and Moments with Corresponding Capacities


No Pu Mux Muy ɸMnx ɸMny ɸMn/Mu NA dt Depth εt ɸ
Depth
kip k-ft k-ft k-ft k-ft in in
1 0.00 66.50 0.00 109.69 0.00 1.649 5.01 14.25 0.00554 0.900
2 455.00 66.50 0.00 98.99 0.00 1.489 13.53 14.25 0.00016 0.650

20
DOTec Corp.

Design of Pile Cap Raft (ACI 350-06)

10.6.4.1 — In normal environmental exposure areas

β ≔ 1.2 γ ≔ 1.4 fy ≔ 60 ksi


⎛ 320 ⋅ ksi ⎞
fs.max ((s)) ≔ max ⎜24 ksi , ―――――― ⎟
⎜ ‾‾‾‾‾‾‾‾‾‾
⎛ s ⎞2 ⎟
⎜⎝ β ⋅ ⎜―― ⎟ + 25 ⎟
⎝ 1 in ⎠ ⎠

fs.max ((8 in )) = 28.267 ksi

fs.max ((9 in )) = 25.901 ksi

fs.max ((10 in )) = 24 ksi

ϕ ≔ 0.9

ϕ ⋅ fy
Sd ((s)) ≔ ――――
γ ⋅ fs.max ((s))

Sd ((8 in )) = 1.365 environmental durability factor

Sd ((9 in )) = 1.489 environmental durability factor

Sd ((10 in )) = 1.607 environmental durability factor

fc ≔ 4 ksi fy ≔ 60 ksi h ≔ 24 in

db ≔ h - 3 in - 1 in = 20 in

dt ≔ h - 2 in - 1 in = 21 in

21
DOTec Corp.

1) Design for one way shear

22
DOTec Corp.

b ≔ 30 ft 30ft design strips will be used for one way shear

Vu ≔ 585 kip

ϕVc ≔ 0.75 ⋅ 2 ‾‾‾‾‾


fc ⋅ psi ⋅ b ⋅ db = 683.052 kip

if ⎛⎝Vu ≤ ϕVc , “Safe” , “UNSAFE”⎞⎠ = “Safe”

23
2) Design for Punching
DOTec Corp.

2) Design for Punching

Punching shear will be checked using the Structural analysis program

24
DOTec Corp.

3) Design for Radial Flexure

25
DOTec Corp.

MuTop ≔ 282 kip ⋅ ft Negative moment at r =0

b ≔ 5 ft

Sd ((10 in )) ⋅ MuTop
Ku ≔ ―――――― = 205.539 psi
b ⋅ dt 2

0.85 ⋅ fc ⎛ ‾‾‾‾‾‾‾‾‾‾
Ku ⎞
ρ ≔ ――― ⋅ ⎜1 - 1 - ―――⎟ = 0.00394 As ≔ b ⋅ dt ⋅ ρ = 4.962 in 2
fy ⎜⎝ 0.383 ⋅ fc ⎟⎠

⎛ As ⎞ b
n ≔ max ⎜――― 2
⎟ = 6.281 S ≔ ―= 9.552 in
⎝ 0.79 in ⎠ n

Use #8 @9" Top rebars at r = 0'

MuTop ≔ 240 kip ⋅ ft Negative moment at r =34'

Sd ((12 in )) ⋅ MuTop
Ku ≔ ―――――― = 174.927 psi
b ⋅ dt 2

0.85 ⋅ fc ⎛ ‾‾‾‾‾‾‾‾‾‾
Ku ⎞
ρ ≔ ――― ⋅ ⎜1 - 1 - ―――⎟ = 0.00333 As ≔ b ⋅ dt ⋅ ρ = 4.2 in 2
fy ⎜⎝ 0.383 ⋅ fc ⎟⎠

⎛ As ⎞ b
n ≔ max ⎜――― 2
⎟ = 5.316 S ≔ ―= 11.286 in
⎝ 0.79 in ⎠ n

Use #8 @11" Top rebars at r = 34'

MuTop ≔ 211 kip ⋅ ft Negative moment at r =8.5', 17', 25.5

Sd ((12 in )) ⋅ MuTop
Ku ≔ ―――――― = 153.79 psi
b ⋅ dt 2

0.85 ⋅ fc ⎛ ‾‾‾‾‾‾‾‾‾‾
Ku ⎞
ρ ≔ ――― ⋅ ⎜1 - 1 - ―――⎟ = 0.00292 As ≔ b ⋅ dt ⋅ ρ = 3.679 in 2
fy ⎜⎝ 0.383 ⋅ fc ⎟⎠

⎛ As ⎞ b
n ≔ max ⎜――― 2
⎟ = 4.656 S ≔ ―= 12.886 in
⎝ 0.79 in ⎠ n

Use #8 @12" Top rebars at r =8.5', 17', 25.5'

26
DOTec Corp.

27
DOTec Corp.

MuBot ≔ 270 kip ⋅ ft Positive moment

b ≔ 5 ft

Sd ((10 in )) ⋅ MuBot
Ku ≔ ―――――― = 216.964 psi
b ⋅ db 2

0.85 ⋅ fc ⎛ ‾‾‾‾‾‾‾‾‾‾
Ku ⎞
ρ ≔ ――― ⋅ ⎜1 - 1 - ―――⎟ = 0.00417
fy ⎜⎝ 0.383 ⋅ fc ⎟⎠

As ≔ b ⋅ db ⋅ ρ = 4.999 in 2

⎛ As ⎞
n ≔ max ⎜――― 2
⎟ = 6.328
⎝ 0.79 in ⎠

b
S ≔ ―= 9.482 in
n

Use #8 @9" Bottom rebars

28
5) Design for Circumferential Flexure
DOTec Corp.

5) Design for Circumferential Flexure

MuTop ≔ 266.7 kip ⋅ ft Negative moment

Sd ((11 in )) ⋅ MuTop
Ku ≔ ―――――― = 194.388 psi
b ⋅ dt 2

0.85 ⋅ fc ⎛ ‾‾‾‾‾‾‾‾‾‾
Ku ⎞
ρ ≔ ――― ⋅ ⎜1 - 1 - ―――⎟ = 0.00372 As ≔ b ⋅ dt ⋅ ρ = 4.683 in 2
fy ⎜⎝ 0.383 ⋅ fc ⎟⎠

⎛ As ⎞ b
n ≔ max ⎜――― 2
⎟ = 5.928 S ≔ ―= 10.121 in
⎝ 0.79 in ⎠ n

Use #8 @10" Top rebars

29
DOTec Corp.

MuTop ≔ 240 kip ⋅ ft Positive moment

Sd ((11 in )) ⋅ MuTop
Ku ≔ ―――――― = 174.927 psi
b ⋅ dt 2

0.85 ⋅ fc ⎛ ‾‾‾‾‾‾‾‾‾‾
Ku ⎞
ρ ≔ ――― ⋅ 1 - 1 - ―――⎟ = 0.00333
⎜ As ≔ b ⋅ dt ⋅ ρ = 4.2 in 2
fy ⎜⎝ 0.383 ⋅ fc ⎟⎠

⎛ As ⎞ b
n ≔ max ⎜――― 2
⎟ = 5.316 S ≔ ―= 11.286 in
⎝ 0.79 in ⎠ n

Use #8 @11" Bottom rebars

30
Base 51 piles.fdb SAFE 2016 v16.0.0 - License #*1YELVAVPTZPDRQD
18 November 2016

ACI 318-14 Punching Shear Check & Design

Geometric Properties

Combination = ULT 2
Point Label = 9
Column Shape = Rectangular
Column Location = Interior
Global X-Coordinate = 0 ft
Global Y-Coordinate = 0 ft

Load Punching Check

Avg. Eff. Slab Thickness = 21.75 in


Eff. Punching Perimeter = 136 in
Cover = 2.25 in
Conc. Comp. Strength = 4 kip/in2
Reinforcement Ratio = 0.0000
Section Inertia I22 = 628212.95 in4
Section Inertia I33 = 628212.95 in4
Section Inertia I23 = 0 in4 Column Punching Perimeter
Gamma_v2 = 0.4
Gamma_v3 = 0.4
Moment Mu2 = -5.482E-013 kip-ft
Moment Mu3= -0.2897 kip-ft
Shear Force = 388.055 kip
Unbalanced Moment Mu2 = -2.193E-013 kip-ft
Unbalanced Moment Mu3= -0.1159 kip-ft
Max Design Shear Stress = 0.1312 kip/in2
Conc. Shear Stress Capacity = 0.1897 kip/in2
Punching Shear Ratio = 0.69

31 Page 1