Leverless Limit Switches
www.goswitch.com www.topworx.com
TopWorx, GO Switch, Leverless Limit Switches, Stroke-to-GO and VIP are all trademarks of TopWorx, Inc.
All other marks used in this catalog are the property of their respective owners.
L-L098 5
C ourtesy ofSteven Engineering, Inc. y 230 R yan W ay,South San Francisco,C A 94080-6370 y M ain O ffice:(650)588-9200 y O utside LocalArea:(800)258-9200 y w w w .stevenengineering.com
C ourtesy ofSteven Engineering, Inc. y 230 R yan W ay,South San Francisco,C A 94080-6370 y M ain O ffice:(650)588-9200 y O utside LocalArea:(800)258-9200 y w w w .stevenengineering.com
Table of Contents
6 GO Switch Product Overview
8 GO Switch Quick Selection Guide
11 Fast Track Delivery List
12 Position Sensors 101
14 GO Switch Leverless Limit Switches
17 Square Leverless Limit Switches
20 10 Series
3300 Fern Valley Road 20 20 Series
Louisville, KY 40213 USA 26 30 Series
502.969.8000 32 80 Series
502.969.5911 fax
37 Round Leverless Limit Switches
www.topworx.com
40 70 Series SPDT
48 70 Series DPDT
59 Cylinder Position Sensors
64 Stroke to GO Switches
71 Specialty Solutions
72 High Temperature Leverless Limit Switches
84 Underwater Leverless Limit Switches
90 Defender Turbine Valve Monitor
93 Accessories
94 Connectors & Cordsets
98 Target Magnets
102 Mounting Kits
105 Switch Installation Principles
117 Applications
127 Reference Material
www.goswitch.com
C ourtesy ofSteven Engineering, Inc. y 230 R yan W ay,South San Francisco,C A 94080-6370 y M ain O ffice:(650)588-9200 y O utside LocalArea:(800)258-9200 y w w w .stevenengineering.com
experience
our experience
Automotive
+ expertise
In the most demanding conditions of processing and
Biotech
manufacturing plants, customers require solutions that are Cement
Chemical
4 5
C ourtesy ofSteven Engineering, Inc. y 230 R yan W ay,South San Francisco,C A 94080-6370 y M ain O ffice:(650)588-9200 y O utside LocalArea:(800)258-9200 y w w w .stevenengineering.com
GO Switch Product Overview
6"
5"
4"
3"
2"
square round
1"
0"
Series or Model 10 Series 20 Series 31, 32, 33, 35 80 Series 71, 72 73, 74, 75, 76 77 7G, 7H, 7I 7L 7C-7E
Sensing Area Side Side End End 3/8" or M12x1 5/8" or M18x1.5 3/4" 5/8" 5/8" or M18x1.5
Maximum Sensing Range 9/16" (14mm) 3/8" (104mm) 1/4" (6mm) 1/4" (6mm) .040" (1mm) .100" (2.5mm) .100" (2.5mm) .090" (2mm) .100" (2.5mm) .090" (2mm)
Maximum Sensing Range 3 3/4" (95mm) 3 3/8" (86mm) 2 5/8" (66mm) 3 7/8" (98mm) .15" (4mm) .35" (9mm) .35" (9mm) .20" (5mm) .35" (9mm) N/A
with Target Magnet
Contact Forms Available SPDT / DMDB SPDT / DMDB SPDT SPDT SPDT SPDT SPDT DPDT / SPDT SPDT SPST N/O & N/C
Latching Latching DPDT SPDT
Enclosures Available Brass Brass Copper (35 only) Brass Stainless Steel Stainless Steel Stainless Steel Stainless Steel Stainless Steel Stainless Steel
Stainless Steel Stainless Steel Stainless Steel (31, 32, 33) Stainless Steel
Approvals Available
Electrical Ratings
30 Series SPDT with LEDs
AC DC AC DC AC DC AC DC AC DC AC DC AC DC AC DC AC DC
Volts Amps Volts Amps Volts Amps Volts Amps Volts Amps Volts Amps Volts Amps Volts Amps Volts Amps Volts Amps Volts Amps Volts Amps Volts Amps Volts Amps Volts Amps Volts Amps .25A@120VAC Volts Amps Volts Amps
120 10 24 3 120 10 24 3 120 6 24 2 120 10 24 3 120 4 24 3 120 4 24 3 120 4 24 3 120 4 24 3 .25A@24VDC 120 0.5 24 0.5
240 5 48 1 240 5 48 1 240 3 48 - 240 5 48 1 240 2 48 - 240 2 48 - 240 2 48 - 240 2 48 - 240 0.5 48 0.5
480 2.5 125 0.5 480 2.5 125 0.5 480 - 480 2.5 125 0.5 125 0.5 125 0.5 125 0.5 125 0.5 125 0.5
250 0.5 - 250 0.5 250 0.5 250 0.5 250 0.5 250 0.5 250 0.5
Page 20 Page 20 Page 26, 28 Page 32 Page 40 Page 42, 44 Page 44 Page 48 Page 52 Page 64
6 7
Note: Please consult factory for application specific ratings.
Courtesy of Steven Engineering, Inc. ! 230 Ryan Way, South San Francisco, CA 94080-6370 ! Main Office: (650) 588-9200 ! Outside Local Area: (800) 258-9200 ! www.stevenengineering.com
GO Switch Quick Selection Guide
Model 11 Model 31 Model 81 Model 72 Model 73 Model 75 Model 77 Model 7C-7F Model 7L & LPS
Long Range End Sensing DPDT 3/8" diameter 5/8" diameter Long Threads Long Body Cylinder Position Sensor BriteLite LEDs
see page 20 see page 26 see page 32 see page 40 see page 42 see page 44 see page 44 see page 64 see page 52, 54
Industrial Environment
General Purpose
Underwater
High Temperature
Read a full description of the A complete list of our most Explosion Proof - Class I, Division 1 Explosion Proof - Class I, Division 1
product and any special fea- popular Fast Track Delivery
21-11524-A2 SPDT, 3/8", Stainless, 73-13523-A2 SPDT, 0.100", Stainless, Leads
tures it may include. models.
Bottom Leads 73-13524-A2 SPDT, 0.100", Stainless, Leads
81-20524-A2 DPDT, 1/4", Stainless, Bottom Leads 7G-23523-A2 DPDT, 0.090", Stainless, Leads
Limit Switches Reed Switches Inductive Proximity Sensors Leverless Limit Switches
Limit switches are electro-mechanical devices Reed Switches are electro-mechanical devices that detect the Inductive proximity sensors are solid-state electronic devices that Leverless limit switches use a unique, hybrid technology to detect
that detect the position of a target by making position of a magnetic target by the attraction of the targets detect the position of metal targets via the disturbance of their the position of a ferrous target via an electro-magnetic field.
direct physical contact with the target. magnetic field. energy field.
ADVANTAGES
ADVANTAGES ADVANTAGES ADVANTAGES The advantages of leverless limit switches:
The advantages of mechanical limit switches: The advantages of reed switches: The advantages of inductive proximity sensors: - No physical contact is required
- Do not require power - No physical contact - No physical contact is required - Do not require power
- Can handle high current loads is required - No moving parts to jam, wear, or break results - Only one moving part, with no metal-to-metal contact making
- Wide operating temperature range - Do not require power in less maintenance it move with nothing to jam, bend, break or wear out
- Immune to electrical noise - Immune to electrical noise - Large selection of shapes and sizes for - Can handle high current loads
- Immune to radio frequency interference - Immune to radio frequency a variety of applications - By far the widest operating temperature range
- No leakage current interference - Not affected by dust or dirt - Immune to electrical noise
- No voltage drops - No leakage current - Immune to radio frequency interference
- Simple Normally Open or Normally Closed - No voltage drops DISADVANTAGES - No leakage current
- Not polarity or voltage sensitive - Simple Normally Open or Normally Closed The disadvantages of inductive proximity sensors: - No voltage drops
- Require external power to operate - Simple Normally Open
DISADVANTAGES DISADVANTAGES - Cannot handle high current loads or Normally Closed
The disadvantages of mechanical limit switches: The disadvantages of reed switches: - Limited operating temperature range cannot be used - Not polarity or voltage sensitive
- Multiple moving parts to maintain - Require a magnetic target to operate in extreme heat or cold - Can be wired in series
(lever arm, push button, body, base, head, contacts, terminals) - Reed element is fragile and can break with physical contact - Affected by temperature fluctuations or parallel
- Moving parts eventually wear and fail - High vibration can cause contact chatter and false signals - Affected by electrical noise - Inherently intrinsically safe
- Physical contact encourages premature failure via damage - Bending metal reeds causes fatigue and premature failures - Affected by radio frequency interference - Large selection of shapes and
- Lever arm connection to internal contacts invites moisture - Contacts can be teased causing uncertainty of target position - Suffer from leakage current and voltage drops sizes for a variety of applications
and dust into contact chamber, causing failure or - Limited selection of shapes, sizes, and capabilities - Only special models are intrinsically safe - Not affected by dust and dirt
maintenance issues - Only rare, expensive models are explosion proof - Not affected by moisture
- Poor repeatability due to wear and tear of moving parts - Polarity sensitive typically must stock both npn and - Not affected by physical contact
- Physical contact causes damage to the target pnp models - Not affected by most caustics
- Poor defense against moisture, dust, and corrosion - Voltage sensitive typically must stock both AC and DC models or chemicals
- Extra cost for sealed contacts and hazardous area approvals - Contact sensitive typically must stock both - Many explosion-proof options
Normally Open and Normally Closed models - Water-proof and sub sea options
- Susceptible to moisture ingression - Extended sensing ranges up to 4"
BETTER
12 GOOD
Mechanical Switches
Reed Switches Inductive Proximity Sensors 13
Courtesy of Steven Engineering, Inc. ! 230 Ryan Way, South San Francisco, CA 94080-6370 ! Main Office: (650) 588-9200 ! Outside Local Area: (800) 258-9200 ! www.stevenengineering.com
GO Switch Leverless Limit Switches Abusive Applications
Because GO Switches have only one
moving part and no metal-to-metal
Unique Design Combines Three Technologies to Surpass Them All
contact making it move, there is
virtually nothing to wear out! They
The design behind GO Switch combines the best of all worlds, bringing are built to last for high cycle, dirty,
together the advantages of mechanical limit switches, reed switches, and and physically abusive applications.
inductive proximity sensors to create a unique, hybrid technology that
reaches new heights of performance.
By combining the best of three technologies, GO Switch enjoys
a significant advantage, surpassing the capabilities that any of the
three could achieve by itself. Explosive Environments
Because GO Switches
As a result, the unique leverless limit switch design enables use dry contacts, they are
GO Switches to operate effectively under conditions that are simple devices suitable
for use in Intrinsically Safe
too extreme for other technologies. applications. And many
models are available for
So if your plant processes include conditions that are extremely Zone 1 Class I, Div 1
hot, cold, wet, dirty, corrosive, abusive, or explosive, be sure to hazardous areas.
Corrosive Conditions
demand technology with an advantage. Specify GO Switch Because most GO Switches have
leverless limit switches. stainless steel housings, they are the
logical choice for applications around
salt water, bleaches, or other caustic
chemicals.
14 15
Courtesy of Steven Engineering, Inc. ! 230 Ryan Way, South San Francisco, CA 94080-6370 ! Main Office: (650) 588-9200 ! Outside Local Area: (800) 258-9200 ! www.stevenengineering.com
GO Switch Leverless Limit Switches Abusive Applications
Because GO Switches have only one
moving part and no metal-to-metal
Unique Design Combines Three Technologies to Surpass Them All
contact making it move, there is
virtually nothing to wear out! They
The design behind GO Switch combines the best of all worlds, bringing are built to last for high cycle, dirty,
together the advantages of mechanical limit switches, reed switches, and and physically abusive applications.
inductive proximity sensors to create a unique, hybrid technology that
reaches new heights of performance.
By combining the best of three technologies, GO Switch enjoys
a significant advantage, surpassing the capabilities that any of the
three could achieve by itself. Explosive Environments
Because GO Switches
As a result, the unique leverless limit switch design enables use dry contacts, they are
GO Switches to operate effectively under conditions that are simple devices suitable
for use in Intrinsically Safe
too extreme for other technologies. applications. And many
models are available for
So if your plant processes include conditions that are extremely Zone 1 Class I, Div 1
hot, cold, wet, dirty, corrosive, abusive, or explosive, be sure to hazardous areas.
Corrosive Conditions
demand technology with an advantage. Specify GO Switch Because most GO Switches have
leverless limit switches. stainless steel housings, they are the
logical choice for applications around
salt water, bleaches, or other caustic
chemicals.
14 15
Courtesy of Steven Engineering, Inc. ! 230 Ryan Way, South San Francisco, CA 94080-6370 ! Main Office: (650) 588-9200 ! Outside Local Area: (800) 258-9200 ! www.stevenengineering.com
Square Sensors
C ourtesy ofSteven Engineering, Inc. y 230 R yan W ay,South San Francisco,C A 94080-6370 y M ain O ffice:(650)588-9200 y O utside LocalArea:(800)258-9200 y w w w .stevenengineering.com
A LOOK INSIDE - MODEL 11
TECHNOLOGY IN ACTION GO Switch 10 and 20 Series side
sensing switches use two permanent
10 - 20 Series
LEVERLESS LIMIT SWITCH
magnets and a ferrous armature to
control a set of dry contacts.
Seesaw armature provides snap action
and solid contact pressure, eliminating
contact teasing and contact chatter
in high vibration applications.
Versatile gold flashed contacts are suitable
for high and low electrical loads, and can
be wired AC or DC, N/O or N/C.
Permanent magnets
never lose their
strength, even
when mounted on
ferrous metal.
Rugged brass or
stainless steel housing
withstands physical
abuse, moisture,
and corrosives.
Conduit hub can be
located in any of 5 positions
for versatile installation.
18 19
C ourtesy ofSteven Engineering, Inc. y 230 R yan W ay,South San Francisco,C A 94080-6370 y M ain O ffice:(650)588-9200 y O utside LocalArea:(800)258-9200 y w w w .stevenengineering.com
10 and 20 Series 502.969.8000 Leverless Limit Switches
Square Switches
Dimensions
Models 11 and 21
1.50" 1.50"
GO Switch Models 11 and 21 are the world's original 11-11110-00 21-11110-00 38 mm 38 mm
CSA Class I Div 2
leverless limit switches. Sensing 1.50" 1.50"
Side Terminal Block 38 38 mm
Area
Their simple design, rugged enclosures, long sensing Sensing mm
11-12110-00 Area
ranges, and global approvals make these switches the CSA Class I Div 2
ideal choice wherever reliable position sensing is Extended Sensing 1.19"
30 mm
needed. 1.06"
11-12510-00 21-11510-00 3.65" 27 mm
CSA Class I Div 2 2.91"
93 mm
Bottom Terminal Block 4.56" 74mm
Features: 116 mm
1.25" 3.81"
32 mm 97 mm .81"
SPDT 10A contacts 21 mm
11-12518-A2 21-11516-A2
Side Sensing UL/CSA General Purpose
-400 to 2210F operating temperature 3 ft. leads
1" (25 mm)
1" 25 mm
Options: .206 dia. sq. nut .206 dia.
sq. nut
21-11524-A2 5 mm mtg. holes 5 mm mtg. holes
Suitable for Zone 0, 1, or 2 explosion proof 1/2-14 NPT 1/2-14 NPT
CSA Class I Div 1; 3 ft. leads conduit outlet
-400 to 3500F high temperature .45"
conduit outlet
.45"
Quick disconnect connector Model 11 11 mm Model 21 11 mm
Underwater capabilities
Model Contact Form Sensing Range Outlet Position Enclosure Material Approvals Wiring Options
Repeatability: .002" (.05 mm) Contact Material: Silver cadmium Target Material: Ferrous steel Conduit Outlet: 1/2" NPT Material: Brass or Stainless Steel Terminal Block
oxide, gold flashed 00 Terminal block only (not recommended for underwater use) (Approval must be 0, 7 or 8)
Response Time: 8 milliseconds Sensing Range: Approx. 3/8" (10mm) 0 CSA / FM certified Cl I, Div 2, Grps
Forms: SPDT, DMDB standard; 9/16" (14mm) extended 1 Brass - coated with flat A,B,C,D; Cl II, Div 2, Grps F & G; Cl III Lead Wires 18 Gauge (.110" dia.) potted-in PVC insulated AWM / TEW stranded lead wires rated at
black lacquer Terminal block. (Contact form must be 1 or 3) 221OF (105OC) 600V UL / CSA listed
Differential: Approx. 5/16" (8 mm) sensing (Model 11)
(Wiring must be 00) A2 36" (914 mm)
Ratings: Resistive A3 72" (1829 mm)
2 High temperature to 350OF (176OC) with
Operating Temperature: -40O AC DC Sensing Range with Target Magnet: 2 Stainless steel** A4 144" (3658 mm)
TeflonTM insulated leads (Model 11) (Contact form
to 221OF (-40O to 105OC). HiTempTM option Volts Amps Volts Amps up to 3 3/4" (95 mm) (max) A_ _ _ Lengths greater than 144" (Specify length in 5' increments (e.g. A150 = 150 ft. of leads))
must be 1 or 3) (Sensing must be 1) (Enclosure must
to 350OF) (1760C) 120 10 24 3 3 Brass - corrosion be 2) (Wiring must be F)
240 5 48 1 1 Standard sensing - approx. 3/8" 1 Behind 2 Left of resistant coating 3 UL listed explosion proof for Cl I, Div 1 & 2; Cable 18 Gauge (.450" dia.) potted-in SO rubber covered cable rated at 194OF (90OC) 600V UL / CSA
11 1 2
Size: 1 / " (38 mm) square x 480 2.5 125 0.5 (10 mm) side sensing Grps A,B,C,D; Cl II, Div 1 & 2, Grps E-G; Cl III listed
sensing sensing (polyurethane)
4 9/16 " (116 mm) overall. Add 1/2" 250 0.5
area area (Enclosure must be 2 or 4) (Wiring must be A, B, or F) B2 36" (914 mm)
B3 72" (1829 mm)
(13 mm) for bottom conduit outlet 2 Extended sensing - approx. 9/16" (Lead seal req'd within 18")
4 Stainless steel - 4 CSA / FM certified explosion proof for Cl I, B4 144" (3658 mm)
1 Single Pole Double Throw (Form C) (14 mm) side sensing (Contact
corrosion resistant Div 1; Grps A,B,C,D; Cl II, Div 1, Grps E-G; B_ _ _ Lengths greater than 144" (Specify length in 5' increments (e.g. B150 = 150 ft. of cable))
21 Size: 11/2" (38 mm) square x 3 Single Pole Double Throw (Form C) Form must be 1 or 3) (Model 11)
coating (polyurethane)** Cl III. (Enclosure must be 2 or 4) (Wiring must be A,
3 13/16" (97 mm) overall. Add 1/2" Latching (maintained contact) Quick Disconnect Male Quick Disconnect only, potted-in connector. (CSA requires a case ground) (Approval
B, or F) (Lead seal req'd within 18")
(13 mm) for bottom conduit outlet (Outlet position must be 2, 4 or 5) 7 Precision sensing - approx. 1/4" must be 7 or 8)
5 Mine Safety Health Administration (MSHA)
5 Double Make Double Break, two- (6 mm) side sensing (minimal **All-welded stainless steel Mini-change Micro-change
approved Explosion Proof, File #X / P-
circuit, Form Z* differential) switches are recommended for 1504-1, X / P-1504-2; 6 ft. (1.829m) DCA 3 - pin Mini-change type DBA 3 - pin Micro-change type
6 Double Make Double Break, two wet or harsh environments. potted-in SO cable only (Enclosure must DCD 4 - pin Mini-change type DBD 4 - pin Micro-change type
circuit, Form Z Latching* 3 Right of 4 Same side as be 2) (Wiring must be B3) DCG 5 - pin Mini-change type DBG 5 - pin Micro-change type
(maintained contact) (Outlet position sensing sensing area 6 CSA / FM certified explosion proof for Cl I,
Need Accessories? area Div 2; Grps A,B,C,D; Cl II, Div 2, Grps E-G; SubSeaTM Underwater Connector (Enclosure must be 2 or 4) (Approval 7 or 8)
must be 2, 4 or 5)
Cl III (Wiring must be A, B, or F) (Lead seal req'd 3DD 3 pin, certified not to leak underwater (includes male/female DelrinTM lock sleeves)
See pp. 92-103 for: within 18") 4DD 4 pin, certified not to leak underwater (includes male/female DelrinTM lock sleeves)
*CSA certification for DMDB require potted-in 3DE 3 pin right-angle, certified not to leak underwater
7 CSA certified General Purpose
Range Extending leads or cable. 4DE 4 pin right-angle, certified not to leak underwater
8 UL listed General Purpose
Target Magnets
Mounting Brackets HiTemp Wire 18 gauge (.070") dia. potted-in TeflonTM insulated leads rated at 482oF (250oC) 600V UL /
Connectors and more! CSA listed
F2 36" (914 mm)
5 Bottom of enclosure
F3 72" (1829 mm)
Form C - SPDT Form Z - SPDT-DB F4 144" (3658 mm)
F_ _ _ Lengths greater than 144" (Specify length in 5' increments (e.g. F150 = 150 ft. of leads))
Ordering Guide
Fill in the boxes to create your
ordering number.
Model Contact Form Sensing Range Outlet Position Enclosure Material Approvals Wiring Options
20 - - 21
10 and 20 Series Approvals & Wiring 502.969.8000 Leverless Limit Switches
Square Switches
Extended Sensing with External Target Magnets Wiring Diagrams (male view)
AMP3 Target Magnet AMS4 Target Magnet 4 Wire PVC & HiTemp Leads Mini-Change QDC - 5 Pin - SPDT
COM N/C
10 Series 20 Series 10 Series 20 Series N/C Red Pin 1 N/O
Contact 1 2 7 1 7 Contact 1 2 7 1 7 N/O Ground or
N/O Blue Pin 2 N/C
Form Standard Extended Precision Standard Precision Form Standard Extended Precision Standard Precision Earth
SPDT
Sensing 1" (25mm) 1-1/4" (32mm) 11/16" (17mm) 1" (25 mm) 3/4" (19 mm)
SPDT
Sensing 1-1/4" (32mm) 1-9/16" (40mm) 7/8" (22mm) 1-3/8" (35 mm) 1" (25 mm) COM Black Terminal Pin 3 GND
Differential 1/2" (13mm) 5/8" (16mm) 7/16" (11 mm) 3/4" (19 mm) 7/16" (11 mm) Differential 11-16" (17mm) 11/16" (17mm) 1/2" (13 mm) 7/8" (22 mm) 7/16" (11 mm)
GND Green SPDT (Terminal Block) Pin 4 Inactive
SPDT Sensing 15/16" (24mm) 1-1/4" (32mm) 3/4" (19mm) 1" (25 mm) 13/16" (21 mm) SPDT Sensing 1-3/16" (30mm) 1-5/8" (40mm) 1" (25 mm) 1-7/16" (37mm) 1" (25 mm)
Latching Differential N/A N/A N/A N/A N/A Latching Differential N/A N/A N/A N/A N/A
Terminations A & F Pin 5 COM
Sensing 1" (25mm) 9/16" (14mm) 1" (25 mm) 3/4" (19 mm) Sensing 1-1/4" (32 mm) 13/16" (21mm) 1-15/16" (37mm) 1" (25 mm)
DMDB N/A DMDB N/A
Differential 11/16" (17mm) 7/16" (11mm) 1" (25 mm) 11/16" (17 mm) Differential 7/8" (22 mm) 1/2" (13mm) 9/16" (14 mm) 3/4" (19 mm) Termination DCG
N
Sensing 1" (25mm) 1-1/4" (32 mm) Sensing 1-11-32" (34 mm) 1-9/16" (40mm) C
DMDB Latching N/A N/A N/A DMDB Latching N/A N/A N/A
Differential N/A N/A Differential N/A N/A
N
SO Cable O Mini-Change QDC - 5 Pin - DMDB
AMC5 Target Magnet AMF6 Target Magnet N/C Red Pin 1 N/C 2
10 Series 20 Series 10 Series 20 Series N/O White DMDB (Two Circuit) Pin 2 N/C 1
Contact 1 2 7 1 7
Same polarity only
Contact 1 2 7 1 7 COM Black Pin 3 GND
Form Standard Extended Precision Standard Precision Form Standard Extended Precision Standard Precision
Sensing 3-3/8" (86mm) 3-3/4" (95mm) 2-3/8" (60mm) 3-3/8" (86mm) 2-5/8" (86mm) Sensing 2-7/16" (62mm) 3" (76mm) 1-15/16" (33mm) 2-7/16"(62mm) 1-9/16" (40mm) GND Green Pin 4 N/O 1
SPDT SPDT 1-1/2" (38mm) 1-11/16"(38mm) 1-3-32" (28mm) 1-15/16"(49mm)
Differential 1-1/2" (38mm) 1-1/2" (38mm) 1" (25mm) 1-3/4" (44mm) 1" (25mm) Differential 7/8" (22mm)
Termination B Pin 5 N/O 2
SPDT Sensing 3-3/32" (79mm) 3-7/8" (98mm) 2-11/16" (68mm) 3-7/16" (87mm) 2-13/16" (71mm) SPDT Sensing 2-5/32" (55mm) 3-3/16"(81 mm) 1-9/16" (40mm) 2-1/2" (64mm) 1-13/16"(46mm)
Latching Differential N/A N/A N/A N/A N/A Latching Differential N/A N/A N/A N/A N/A Termination DCG
Sensing 3-7/16" (87mm) 2-7/32" (56mm) 3-3/8" (86mm) 2-5/8" (67mm) Sensing 2-1/4" (57mm) 1-1/8" (29mm) 2-3/8" (60mm) 1-1/2" (38mm)
DMDB N/A DMDB N/A
Differential 1-13/16"(46mm) 1" (25mm) 2" (51mm) 1-3/8" (35mm) Differential 1-13/16" (46mm) 1-3/32" (28mm) 2-13/16"(71mm) 1-1/2" (38mm) 2
DMDB Latching
Sensing 3-3/8" (86mm)
N/A N/A
3-7/8" (98mm)
N/A DMDB Latching
Sensing 2-7/16" (62mm)
N/A N/A
3" (76mm)
N/A
DMDB Form Z PVC Leads DMDB 5 Conductor SO Cable Micro-Change QDC - 4 Pin
Differential N/A N/A Differential N/A N/A
Red & Red/White N/C 2 White Pin 1 COM
N/C 1 & 2
Stripe 1
Agency Approvals N/C 1 Red Pin 2 N/O
3
Blue & Blue/White
N/O 1 & 2 GND Green Pin 3 N/C
Approvals (3) (4) (5) (6) (7) (8) (0) Stripe
UL CSA/FM MSHA CSA/FM CSA UL CSA/FM Termination A N/O 1 Orange Pin 4 GND 4
Class 1 Class 1 Class 1 General General Class 1
N/O 2 Black Termination DBD
Div 1 Div 1 Div 2 Purpose Purpose Div 2
Termination Options DMDB 4 Conductor SO Cable Termination B
F - Potted HiTempTM Leads X SS X SS SS SS Mini-Change QDC - 4 Pin SubSea - 4 Pin - Lock Sleeve
Sealed contact
chamber prevents
moisture or dust
from reaching the
contacts.
Conduit outlet on
bottom of housing for
versatile installation. Versatile gold
flashed contacts
are suitable for
Multiple wiring options:
high and low
- Terminal Block
electrical loads,
- Lead Wires
and can be
- Cable
Operated wired AC or DC,
Unoperated - Quick Disconnects
N/O or N/C.
The armature is positioned off-center When a ferrous target enters the
of the magnet, creating a dominant sensing area of the switch, it diverts Consumes no power to operate and
magnetic flux field on the sensing end flux lines from the armature to create has no current leakage or voltage drop.
of the switch which draws the arma- a magnetic dominance on the oppo-
ture down to its unoperated position, site side. As a result, the armature
closing a contact circuit. snaps to its operated position, closing Options Available Key Benefits
the other contact circuit.
- Explosion Proof GO Switches are simple and built to last.
Shown: Model 81 - SPDT or DPDT
When the target is removed the
armature snaps back to its original, - HiTemp to 350 With only one moving part and no
unoperated position. - SubSea Submersible metal-to-metal contact forcing it to
- Hermetically Sealed move, there is nothing to wear out!
24 25
C ourtesy ofSteven Engineering, Inc. y 230 R yan W ay,South San Francisco,C A 94080-6370 y M ain O ffice:(650)588-9200 y O utside LocalArea:(800)258-9200 y w w w .stevenengineering.com
Models 31, 32 & 33 502.969.8000 Leverless Limit Switches
Square Switches
Dimensions
1.00" 1.00" 1.00"
Models 31, 32, and 33 1.00"
25 mm 1.00" 1.00" 25 mm 25 mm
25 mm
25 mm 25 mm
Sensing Sensing
GO Switch Models 31, 32, and 33 offer end sensing in Area Area
compact stainless steel enclosures. Sensing
Area
Features:
SPDT 6A contacts 2.44" (4) Mtg. Holes 3.43"
62 mm .203" (5.15mm) .56"
End Sensing .56" .56" dia. through
87 mm .56"
14 mm 14 mm 14 mm
-400 to 2210F operating temperature 3.25"
14 mm case
Options: 82 mm 2.25" 4.25" (4) Mtg. Holes .203"
57 mm 108 mm (5.15 mm) dia.
Suitable for Zone 0, 1, or 2 explosion proof through case
Quick disconnect connector
1
1
/2"-14 NPT
/2"-14 NPT
Conduit Outlet
Conduit Outlet
Model 31 Model 32 Model 33
Model Contact Form Sensing Range Outlet Position Enclosure Material Approvals Wiring Options
Repeatability: .002" (.05 mm) Contact Material: Silver cadmium Target Material: Ferrous steel Conduit Outlet: 1/2 NPT, 2 Stainless steel SAA Lead Wires 18 Gauge (.110" dia.) potted-in PVC insulated AWM / TEW stranded lead wires
oxide, gold flashed bottom. (Model 31 and 33) rated at 221OF (105OC) 600V UL / CSA listed
Response Time: 8 milliseconds Sensing Range: Approx. 1/4" (6 mm) 4 Stainless steel - 4 CSA / FM certified explosion proof
Form: SPDT, Form C 3 No conduit hub corrosion resistant for Cl I, Div 1 & 2; Grps A,B,C,D; Cl A2 36" (914 mm)
Differential: Approx. 1/4" (6 mm) Sensing Range with Target Magnet: (Model 32) (includes coating (polyurethane) II, Div 1 & 2, Grps E-G; Cl III. A3 72" (1829 mm)
Ratings: Resistive up to 2 5/8" (66 mm) (max) mounting bracket) (Model 31) A4 144" (3658 mm)
Operating Temperature: -40O A_ _ _ Lengths greater than 144" (Specify length in feet (e.g. A150 = 150 ft. of leads))
to 221OF (-40O to 105OC) AC DC
7 Precision sensing - approx. 1/4" 6 CSA / FM certified explosion proof
Volts Amps Volts Amps 5 Conduit hub on bottom
(6 mm) side sensing (minimal for Cl I, Div 1 & 2; Grps A,B,C,D; Cl Cable 18 Gauge (.250" dia.) potted-in PVC rubber covered cable rated at 194OF (90OC) 600V
120 6 24 2 of enclosure with
240 3 48 * differential) II, Div 1 & 2, Grps E-G; Cl III. (Model UL / CSA listed
31 Size: 1" (25 mm) square x mounting holes
480 * 125 * 31) (Wiring must be F)
3 1/4" (81 mm) overall (Model 31 and 33)
250 0.25 B2 36" (914 mm)
7 CSA certified General Purpose B3 72" (1829 mm)
32 Size: 1" (25 mm) square x
(Wiring must be A, B, or D) B4 144" (3658 mm)
2 1/4" (57 mm) overall 1 Single Pole Double Throw (Form C)
(includes mounting bracket)
B_ _ _ Lengths greater than 144" (Specify length in feet (e.g. B150 = 150 ft. of cable))
8 UL listed General Purpose
33 Size: 1" (25 mm) square x Quick Disconnect Male Quick Disconnect only, potted-in connector. (CSA requires a case
4 1/4" (108 mm) overall A SAA: Ex s IIC T6 IP65; Cl I Zone 1 ground) (Approval must be 7 or 8) (Model 31 only and 33) Refer to pp. 92-103 for mating cable
& 2; EX S IIC T6 IP65; Cl I Zone 0; assemblies and Aura Light Adapters.
DIP Cl II (Intrinsically safe with entity
approved barrier. Install per NEC Article Mini-change Micro-change
501.) (Model 31 and 33) (Wiring must DCA 3 - pin Mini-change type DBA 3 - pin Micro-change type
Need Accessories? be A) DCD 4 - pin Mini-change type DBD 4 - pin Micro-change type
Extended Sensing Range with DCG 5 - pin Mini-change type DBG 5 - pin Micro-change type
See pp. 92-103 for:
External Target Magnets
Range Extending (See Accessories for External Target Magnets)
Target Magnets HiTemp Wire18 gauge (.070") dia. potted-in TeflonTM insulated leads rated at 482oF (250oC)
Mounting Brackets Models 31 and 32 600V UL / CSA listed
Connectors and more! Magnet Sensing Differential
AMP3 3 /4 " 1-1/4" F2 36" (914 mm)
AMS4 1" 1-1/2" F3 72" (1829 mm)
AMC5 2-5/8" 3-1/2" F4 144" (3658 mm)
Form C - SPDT
AMF6 1-5/8" 4-1/4" F_ _ _ Lengths greater than 144" (Specify length in feet (e.g. F150 = 150 ft. of leads))
Ordering Guide
Fill in the boxes to create your
ordering number.
Model Contact Form Sensing Range Outlet Position Enclosure Material Approvals Wiring Options
- -
26 1 7 27
C ourtesy ofSteven Engineering, Inc. y 230 R yan W ay,South San Francisco,C A 94080-6370 y M ain O ffice:(650)588-9200 y O utside LocalArea:(800)258-9200 y w w w .stevenengineering.com
Model 35 502.969.8000 Leverless Limit Switches
Square Switches
Dimensions .75" .75"
Model 35 19 mm 19 mm
Sensing
Area
The GO Switch Model 35 leverless limit switch has set 35-13319-A2
the standard for reliable performance in valve position Hermetic Seal
monitors.
Model 35
Model Contact Form Sensing Range Outlet Position Enclosure Material Approvals Wiring Options
Repeatability: .002" (.05 mm) Contact Material: Silver cadmium Target Material: Ferrous steel 3 No conduit hub 1 Copper - coated with Lead Wires 18 Gauge (.110" dia.) potted-in PVC insulated AWM / TEW stranded lead
oxide, gold flashed flat black lacquer wires rated at 221OF (105OC) 600V UL / CSA listed
Response Time: 8 milliseconds Sensing Range: Approx. 1/10" (2.5 mm)
Forms: SPDT, Form C 7 CSA certified General Purpose A2 36" (914 mm)
Differential: Approx. 5/32" (4 mm) Sensing Range with Target Magnet: (Wiring must be A or B) A3 72" (1829 mm)
Ratings: Resistive up to 3 5/8" (92mm) (max) A4 144" (3658 mm)
Operating Temperature: -40O to 221OF 8 UL listed General Purpose A_ _ _ Lengths greater than 144" (Specify length in feet (e.g. A150 = 150 ft. of leads))
(-40O to 105OC) AC DC
1 10
Volts Amps Volts Amps
3 Approx. / " (2.5 mm) end
9 Hermetic seal; UL listed General Cable 18 Gauge (.250" dia.) potted-in PVC rubber covered cable rated at 194OF (90OC)
120 4 24 3 sensing
Purpose 600V UL / CSA listed
3 4 240 2 48 1
35 Size: / " (19 mm) square x
480 * 125 0.5
2 1/2" (64 mm) overall
250 * B2 36" (914 mm)
B3 72" (1829 mm)
Model 35
B4 144" (3658 mm)
B_ _ _ Lengths greater than 144" (Specify length in feet (e.g. B150 = 150 ft. of cable))
1 Single Pole Double Throw (Form C)
Agency Approvals
Square Switches
Wiring Diagrams (male view)
PVC & Teflon Leads - UL Mini-Change QDC - 3 Pin
Approvals (4) (6) (7) (8) (9) (A)
CSA/FM CSA/FM CSA UL Hermetic SAA N/C Red Pin 1 COM
Class 1 Class 1 General General Seal Exs IIc N/O Blue Pin 2 N/C
Div 1 Div 2 Purpose Purpose Model 35 T6 IP65 COM Black Pin 3 N/O
Termination Options
Termination A & F Termination DCA
NEMA Ratings
PVC Cable - UL Micro-Change QDC - 4 Pin
2
Non-Hazardous Hazardous N/C Red Pin 1 COM 3
N/O White Pin 2 N/O
NEMA CLASSES 4 4X 6 6P 7 9 1
COM Black Pin 3 N/C
D - Quick Disconnect X X X X 2
PVC Cable - CSA Micro-Change QDC - 3 Pin 3
F - Potted HiTemp Leads
TM
X X X X X X N/C Red Pin 1 COM
N/O White Pin 2 N/C
35 Series Hermetic seal X X X X
w/ potting COM Black Pin 3 N/O 1
Termination DBA
GND Green
X = Designed to meet respective NEMA specifications
Termination B
30 31
C ourtesy ofSteven Engineering, Inc. y 230 R yan W ay,South San Francisco,C A 94080-6370 y M ain O ffice:(650)588-9200 y O utside LocalArea:(800)258-9200 y w w w .stevenengineering.com
80 Series 502.969.8000 Leverless Limit Switches
Square Switches
Dimensions
1.50" 1.50" 1.50" 1.50"
Model 81 38 mm 38 mm 38 mm 38 mm
Sensing Sensing
Area Area
The GO Switch Model 81 offers end sensing and an
81-20516-A2
optional Double Pole Double Throw contact arrange- CSA Class I Div 2
ment. With its brass or stainless steel housings and DPDT Brass, 3 ft. leads 3.12" 4.38" 3.12"
79 mm 111 mm 79 mm
global certifications, it is a popular choice around the
world. 81-20518-A2
UL General Purpose 3.66"
4.88"
DPDT Brass, 3 ft. leads 124 mm 93 mm
Features:
SPDT or DPDT 10A contacts 81-20524-A2
Mtg. Holes
End Sensing CSA Class I Div 1 Mtg. Holes (2) (2) .206" Dia.
DPDT Stainless, 3 ft. leads .206" Dia. 5 mm
-400 to 2210F operating temperature 5 mm
Options:
1/2"14NPT
Suitable for Zone 0, 1, or 2 explosion proof .31" Conduit Outlet
.31"
-400 to 3500F high temperature 8 mm 8 mm .45" 1" sq. hub
Quick disconnect connector 1/2"14NPT 12 mm
.875" .875"
22 mm Conduit Outlet 22 mm
Underwater capabilities
Model 81
Model Contact Form Sensing Range Outlet Position Enclosure Material Approvals Wiring Options
Repeatability: .002" (.05 mm) Contact Material: Silver cadmium Target Material: Ferrous steel Conduit Outlet: 1/2 NPT Material: Brass or Stainless Steel SAA Terminal Block
oxide, gold flashed Two locations 00 Terminal block only (SPDT only, Approvals must be 1)
Response Time: 8 milliseconds Sensing Range: Approx. 1/4" (6 mm) 1 No Approvals (Wiring must be 00)
Forms: DPDT, Form CC; SPDT, Form C 1 Side outlet 1 Brass - coated with flat Lead Wires 18 Gauge (.110" dia.) potted-in PVC insulated AWM / TEW stranded lead wires rated at
black lacquer 2 High temperature to 350OF (176OC) with 221OF (105OC) 600V UL / CSA listed
Differential: Approx. 1/4" (6 mm) Electrically isolated Sensing Range with Target Magnet:
TeflonTM insulated leads A2 36" (914 mm)
up to 3 7/8" (98 mm) (max) 5 Bottom of enclosure A3 72" (1829 mm)
Operating Temperature: -40O to 221OF Ratings: Resistive 2 Stainless steel A4 144" (3658 mm)
3 UL listed explosion proof for Cl I, Div 1 & 2;
(-40OC to 105OC). HiTempTM option to 0 Approx. 1/4" (6 mm) end sensing A_ _ _ Lengths greater than 144" (Specify length in feet (e.g. A150 = 150 ft. of leads))
AC DC Grps A,B,C,D; Cl II, Div 1 & 2, Grps E-G; Cl
350OF) (1760C) 3 Brass - corrosion III (Enclosure must be 2 or 4) (Lead seal req'd
Volts Amps Volts Amps
resistant coating within 18") (DPDT, leads only) Cable 18 Gauge (.450" dia.) potted-in SO rubber covered cable rated at 194OF (90OC) 600V UL / CSA listed
120 10 24 3
81 Size: 11/2" (38 mm) square x (Contact Form must be 1)
240 5 48 1 (polyurethane)
4 3/8" (111 mm) overall. Subtract 4 CSA / FM certified explosion proof for Cl I, B2 36" (914 mm)
480 2.5 120 0.5
1 Div 1 & 2; Grps A,B,C,D; Cl II, Div 1 & 2, B3 72" (1829 mm)
/2" (13 mm) from length for side 250 0.5
4 Stainless steel - Grps E-G; Cl III. (Enclosure must be 2 or 4) B4 144" (3658 mm)
conduit
corrosion resistant B_ _ _ Lengths greater than 144" (Specify length in feet (e.g. B150 = 150 ft. of cable))
coating (polyurethane) 6 CSA / FM certified explosion proof for Cl I,
1 Single Pole Double Throw (Form C) Quick Disconnect Male Quick Disconnect only, potted-in connector. (CSA requires a case ground) (Approval
Div 1 & 2; Grps A,B,C,D; Cl II, Div 1 & 2,
Grps E-G; Cl III must be 7 or 8) Refer to pp. 92-103 for mating cable assemblies and Aura Light Adapters.
2 Double Pole Double Throw
(Form CC) 7 CSA certified General Purpose Mini-change
DCA 3 - pin Mini-change type
8 UL listed General Purpose DCD 4 - pin Mini-change type
DCG 5 - pin Mini-change type
Need Accessories? A SAA: Ex s IIC T6 IP65; Cl I Zone 1 & 2; EX
S IIC T6 IP65; Cl I Zone 0; DIP Cl II SubSeaTM Underwater Connector (Enclosure must be 2 or 4)
See pp. 92-103 for: Extended Sensing with (Intrinsically safe with entity approved barrier. 3DD 3 pin, certified not to leak underwater (includes male/female DelrinTM lock sleeves)
External Target Magnets Install per NEC Article 501.) (Wiring must be A 4DD 4 pin, certified not to leak underwater (includes male/female DelrinTM lock sleeves)
Range Extending (See Accessories for External Target Magnets) or 00) 8DD 8 pin, certified not to leak underwater (includes male/female DelrinTM lock sleeves)
Target Magnets 3DE 3 pin right-angle, certified not to leak underwater (Enclosure must be 2 or 4)
Mounting Brackets B SAA: High Temp EX S IIC T6 IP65; Cl I 4DE 4 pin right-angle, certified not to leak underwater (Enclosure must be 2 or 4)
Connectors and more! Magnet Sensing Differential
Zone 1 & 2; EX S IIC T6 IP65; Cl I Zone 0;
AMP3 15/16" 3/4" DIP Cl II (Intrinsically safe with entity approved HiTemp Wire 18 gauge (.070") dia. potted-in TeflonTM insulated leads rated at 482oF (250oC) 600V UL /
AMS4 1-3/8" 1-1/8" barrier. Install per NEC Article 501.) (Wiring must CSA listed
AMC5 3-7/8" 2-1/8" be F) F2 36" (914 mm)
Form C - SPDT Form CC - DPDT AMF6 2-3/4" 1-5/8" F3 72" (1829 mm)
F4 144" (3658 mm)
Ordering Guide F_ _ _ Lengths greater than 144" (Specify length in feet (e.g. F150 = 150 ft. of leads))
Fill in the boxes to create your
ordering number.
Model Contact Form Sensing Range Outlet Position Enclosure Material Approvals Wiring Options
- 0 - -
32 81 33
C ourtesy ofSteven Engineering, Inc. y 230 R yan W ay,South San Francisco,C A 94080-6370 y M ain O ffice:(650)588-9200 y O utside LocalArea:(800)258-9200 y w w w .stevenengineering.com
80 Series Approvals & Wiring 502.969.8000 Leverless Limit Switches
Square Switches
Agency Approvals Wiring Diagrams (male view)
4 Wire PVC & HiTemp Leads SubSea - 3 Pin - Lock Sleeve
Approvals (1) (3) (4) (6) (7) (8) (A)
N/C Red Pin 1 N/C
No UL CSA/FM CSA/FM CSA UL SAA
N/O Blue Pin 2 COM
Approvals Class 1 Class 1 Class 1 General General Exs IIc
Div 1 Div 1 Div 2 Purpose Purpose T6 IP65 COM Black Pin 3 N/O
Termination Options GND Green Termination 3DD
Terminations A & F
00 - Terminal Block X
X = Approvals Available
PVC Leads, Cable & SubSea - 4 Pin - Lock Sleeve
Teflon Leads
Pin 1 COM
N/C1 - Red N/C2 - Red/White Stripe
Pin 2 N/O
N/O1 - Blue N/O2 - Blue/White Stripe
Pin 3 N/C
COM1 - Black COM2 - Black/White Stripe
Pin 4 GND
NEMA Ratings GND - Green
Termination 4DD
Termination A & F
Non-Hazardous Hazardous
Pin 1 N/O2
Mini-Change QDC - 5 Pin Pin 2 COM1
Pin 1 N/O Pin 3 N/C2
Pin 2 N/C Pin 4 N/C1
Pin 3 GND Pin 5 COM2
Pin 4 Inactive Pin 6 N/O1
Pin 5 COM Pin 7 GND
Termination DCG Termination DCH
34 35
C ourtesy ofSteven Engineering, Inc. y 230 R yan W ay,South San Francisco,C A 94080-6370 y M ain O ffice:(650)588-9200 y O utside LocalArea:(800)258-9200 y w w w .stevenengineering.com
Models 71 and 72 502.969.8000 Leverless Limit Switches
Round Switches
Models 71 and 72
Features: 1.15
SPDT 4A contacts (29mm)
Intrinsically Safe
1.55" .625"
-400 to 2210F operating temperature .625" (39mm) (16mm)
(16mm)
Options: 3.38"
Suitable for Zone 0, 1, or 2 explosion proof 1.55" 1.25 1/2"-14 NPT
CONDUIT OUTLET
(86mm)
(39mm) (32mm)
-400 to 4000F high temperature
Quick disconnect connector 3.93"
(100mm)
English or Metric threads
Model 71 Model 72
Model Contact Form Sensing Range Outlet Position Enclosure Material Approvals Wiring Options
Repeatability: .002" (.05 mm) typical Contact Material: Palladium silver with Target Material: Ferrous steel Conduit Outlet: 1/2" NPT SAA Lead Wires 18 Gauge (.110" dia) potted-in PVC insulated AWM / TEW stranded lead wires,
2 303 stainless steel
sawtooth surface configuration rated at 221OF (105OC) 600V UL / CSA listed
(rated 2,000 PSI) 2 High temperature to 400OF (204OC)
Response Time: 8 milliseconds Sensing Range: Approx. .040" (1 mm) 2 Side entry (Model 72) A2 36" (914 mm)
Form: SPDT, Form C end sensing (Approval must be 8)
with TeflonTM insulated leads
A3 72" (1829 mm)
Differential: Approx. .020" (.51 mm) 6 316 stainless steel (Wiring must be F)
(Wiring must be F) A4 144" (3658 mm)
Ratings: Resistive Sensing Range with Target Magnet: (rated 2,000 PSI)
3 UL listed explosion proof for Cl I, Div A_ _ _ Lengths greater than 144" (Specify length in feet (e.g. A150 = 150 ft. of leads))
Operating Temperature: -40O to 221OF up to .15 (4 mm)
AC DC
5 Bottom of enclosure 1 & 2; Grps A,B,C,D; Cl II, Div 1 & 2,
(-40O to 105OC). HiTemp option to 400OF Volts Amps Volts Amps
(204OC)
Grps E-G; Cl III (Model 71) (Wiring must Cable 18 Gauge (.250" dia.) potted-in PVC cable, rated at 176OF (80OC) 300V, UL / CSA listed
120 4 24 3 6 Standard sensing - approx. .040"
240 2 48 1.25
be A, B, or F) (Lead seal req'd within 18") B2 36" (914 mm)
(1 mm) end sensing
71 Model 71 480 * 125 0.5 4 CSA certified explosion proof B3 72" (1829 mm)
3/8" (10 mm) dia. x 3 15/16" (100 mm) 250 0.5 for Cl I, Div 1; Grps A,B,C,D; Cl II, B4 144" (3658 mm)
long, with 3/8"-24 UNF x 11/2" Div 1; Grps E-G; Cl III (Model 71) (Lead B_ _ _ Lengths greater than 144" (Specify length in feet (e.g. B150 = 150 ft. of cable))
(38 mm) threads and 1/2" NPT seal req'd within 18")
conduit hub 1 Single Pole Double Throw Water Resistant 18 Gauge (.250" dia) PVC cable rated at 176OF (80OC) 300V with water-
6 CSA certified Cl I, Div 2; Grps
(Form C) resistant squeeze connector. (Model 72) UL/CSA listed
71M Model 71 A,B,C,D; Cl II, Div 2; Grps E-G; Cl III
C2 36" (914 mm)
M12 x 1 external metric thread (Model 71) (Wiring must be A, B, or F)
C3 72" (1829 mm)
(Lead seal req'd within 18")
C4 144" (3658 mm)
72 Model 72
3/8" (10 mm) dia. x 3 3/8" (86 mm) 7 CSA certified General Purpose C_ _ _ Lengths greater than 144" (Specify length in feet (e.g. C150 = 150 ft. of cable))
long, with 3/8"-24 UNF x 11/2" 8 UL listed General Purpose
(38 mm) threads. No conduit hub Quick Disconnect Male Quick Disconnect only, potted-in connector. (CSA requires a case
A SAA: Ex s IIC T6 IP65; Cl I Zone 1 & ground) (Approval must be 7 or 8) Refer to pp. 93-104 for mating cable assemblies and
72M Model 72 2; EX S IIC T6 IP65; Cl I Zone 0; DIP Aura Light Adapters.
M12 x 1 external metric thread Cl II (Intrinsically safe with entity approved Mini-change Micro-change
Extended Sensing Range with barrier. Install per NEC Article 501.) (Wiring DCA 3 pin Mini-change type DBA 3 pin Micro-change type
Need Accessories?
External Target Magnets must be A) (Model 71) DCD 4 pin Mini-change type DBD 4 pin Micro-change type
(See Accessories for External Target Magnets) See pp. 93-104 for: DCG 5 pin Mini-change type DBG 5 pin Micro-change type
B SAA: High Temp EX S IIC T6 IP65;
Form C - SPDT Range Extending Cl I Zone 1 & 2; EX S IIC T6 IP65;
Magnet Sensing Differential Target Magnets HiTemp Leads 18 gauge (.070" dia. potted-in TeflonTM insulated leads rated at 482oF (250oC))
Cl I Zone 0; DIP Cl II (Intrinsically safe
AMP3 .12" .07" Mounting Brackets with entity approved barrier. Install per NEC 600V UL / CSA listed (Approval must be 2, 3, 4, 6, 7, 8, or B)
AMS4 .15" .10" Connectors and more! F2 36" (914 mm)
Article 501.) (Wiring must be F) (Model 71)
AMS7 .13" .045" F3 72" (1829 mm)
Ordering Guide F4 144" (3658 mm)
Fill in the boxes to create your F_ _ _ Lengths greater than 144" (Specify length in feet (e.g. F150 = 150 ft. of leads))
ordering number.
Model Contact Form Sensing Range Outlet Position Enclosure Material Approvals Wiring Options
- -
40 71 1 6 41
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Models 73 and 74 502.969.8000 Leverless Limit Switches
Round Switches
Dimensions
Models 73 and 74
conduit hub.
73-13526-A2 1.15"
Class I Div 2, 3 ft. leads (29mm)
Features: 73-13528-A2
SPDT 4A contacts General Purpose 3 ft. leads 1.88"
(48mm) 1.88"
Intrinsically Safe 73-13528-DCA 1/2"-14 NPT
(48mm)
CONDUIT OUTLET
-400 to 2210F operating temperature General Purpose, Mini Connector 2.50"
(64mm)
2.77"
Options: 74-13528-B2 3.62" (70mm)
Suitable for Zone 0, 1, or 2 explosion proof General Purpose, 3 ft. cable (92mm)
Model Contact Form Sensing Range Outlet Position Enclosure Material Approvals Wiring Options
Repeatability: .002" (.05mm) typical Contact Material: Palladium silver with Target Material: Ferrous steel Conduit Outlet: 1/2" NPT SAA Lead Wires 18 Gauge (.110" dia) potted-in PVC insulated AWM / TEW stranded lead wires, rated at
2 303 stainless steel
sawtooth surface configuration O O
221OF (105OC) 600V UL / CSA listed
(rated 2,000 PSI) (Sensing 2 High temperature to 400 F (204 C) with
Response Time: 8 milliseconds Sensing Range: Approx. 2 Side entry with Teflon A2 36" (914 mm)
must be 3) TeflonTM insulated leads (Wiring must be A3 72" (1829 mm)
Form: SPDT, Form C .100 (2.5 mm) end sensing (2,000 PSI) insulated leads (Model 74)
.
Differential: Approx. 020" (.51 mm) F) A4 144" (3658 mm)
.072 (1.8 mm) end sensing (5,000 PSI) (Approval must be 2 or 8)
Ratings: Resistive 3 HiPressure - 303 stainless A_ _ _ Lengths greater than 144" (Specify length in feet (e.g. A150 = 150 ft. of leads))
.060 (1.5 mm) end sensing (10,000 PSI) (Wiring must be F) 3 UL listed explosion proof for Cl I, Div 1 & 2;
Operating Temperature: -40O to 221OF AC DC steel (rated 5,000 PSI) Grps A,B,C,D; Cl II, Div 1 & 2, Grps E-G;
5 Bottom of enclosure Cable 18 Gauge ( .250" dia.) potted-in PVC cable, rated at 176OF (80OC) 300V, UL / CSA listed
(-40O to 105OC). HiTemp to 400OF (204OC) Volts Amps Volts Amps
Sensing Range with Target Magnet: (Sensing must be 4) (Approval Cl III (Model 73 ) (Wiring must be A, B, or F) B2 36" (914 mm)
120 4 24 3
up to .35 (9 mm) must be 2, 7, 8, or 9) (Lead seal req'd within 18") B3 72" (1829 mm)
240 2 48 1.25
B4 144" (3658 mm)
73 Model 73 480 * 125 0.5 4 CSA certified explosion proof for Cl I Div 1
3 Standard sensing - approx. .100" B_ _ _ Lengths greater than 144" (Specify length in feet (e.g. B150 = 150 ft. of cable))
5
/8" (16 mm) dia. x 35/8" (92 mm) 250 0.5 4 HiPressure - 303 stainless & 2; Grps A,B,C,D; Cl II, Div 1; Grps E-G; Cl
(3 mm) end sensing (Enclosure steel (rated 10,000 PSI)
long with 5/8"-18 UNF x 17/8" III (Model 73) (Lead seal req'd within 18") Water Resistant 18 Gauge (3 cond .250" dia; 4 cond .450" dia) PVC cable rated at 176OF (80OC) 300V
(48 mm) threads and 1/2" NPT must be 2 or 6) (Sensing must be 5) (Approval with water-resistant squeeze connector. (Model 74)
4 HiPressure sensing - approx. 6 CSA certified Cl I, Div 2; Grps A,B,C,D;
conduit hub 1 Single Pole Double Throw (Form C) must be 2, 7, 8, or 9) C2 36" (914 mm)
Cl II, Div 2; Grps E-G; Cl III (Model 73)
.072" (2 mm) end sensing C3 72" (1829 mm)
(Wiring must be A, B, or F) (Lead seal C4 144" (3658 mm)
73M Model 73 (Enclosure must be 3 and Approvals 6 316 stainless steel req'd within 18") C_ _ _ Lengths greater than 144" (Specify length in feet (e.g. C150 = 150 ft. of cable))
M18 x 1 external metric thread must be 2, 7, 8, or 9) (rated 2,000 PSI)
5 HiPressure sensing - approx. 7 CSA certified General Purpose
Quick Disconnect Male Quick Disconnect only, potted-in connector. (CSA requires a case ground)
74 Model 74 .060" (1.5 mm) end sensing 8 UL listed General Purpose (Approvals must be 7 or 8) Refer to pp. 93-104 for mating cable assemblies and Aura Light Adapters.
5
/8" (16 mm) dia. x 23/4" (70 mm)
(Enclosure must be 4 and Approvals
long with 5/8"-18 UNF x 17/8" 9 CENELEC: EExdIIC T6 Zone 1. Mini-change Micro-change
must be 2, 7, or 8)
(48 mm) threads. No conduit hub (EN 50 014 & EN 50 018, BASEEFA DCA 3 - pin Mini-change type DBA 3 - pin Micro-change type
Certificate Ex89C1233X) (Model 73) DCD 4 - pin Mini-change type DBD 4 - pin Micro-change type
74M Model 74 (Wiring must be A or B) DCG 5 - pin Mini-change type DBG 5 - pin Micro-change type
M18 x 1 external metric thread A SAA: Ex s IIC T6 IP65; Cl I Zone 1 & 2; EX
Extended Sensing Range with Need Accessories? SubSea Underwater Connector (Model 73)
External Target Magnets S IIC T6 IP65; Cl I Zone 0; DIP Cl II (Intrin- 3DD 3 pin, certified not to leak underwater
(See Accessories for External Target Magnets) See pp. 93-104 for: sically safe with entity approved barrier. 4DD 4 pin, certified not to leak underwater
Install per NEC Article 501.) (Wiring must be 3DE 3 pin right-angle, certified not to leak underwater
Form C - SPDT Range Extending 4DE 4 pin right-angle, certified not to leak underwater
A)
Magnet Sensing Differential Target Magnets
AMP3 .20" .25" Mounting Brackets B SAA: High Temp 350OF (176OC): EX S IIC
HiTemp Leads 18 gauge (.070" dia. potted-in TeflonTM insulated leads rated at 482oF (250oC) 600V
AMS4 .35" .15" Connectors and more! T6 IP65; Cl I Zone 1 & 2; EX S IIC T6 IP65; UL / CSA listed (Approval must be 2, 3, 4, 6, 7, 8 or B)
AMS7 .20" .05" Cl I Zone 0; DIP Cl II (Intrinsically safe with F2 36" (914 mm)
Ordering Guide entity approved barrier. Install per NEC F3 72" (1829 mm)
Fill in the boxes to create your Article 501.) (Wiring must be F) F4 144" (3658 mm)
ordering number. F_ _ _ Lengths greater than 144" (Specify length in feet (e.g. F150 = 150 ft. of leads))
Model Contact Form Sensing Range Outlet Position Enclosure Material Approvals Wiring Options
42 - - 43
1
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Models 75, 76 & 77 502.969.8000 Leverless Limit Switches
Round Switches
1.00" (25mm)
Models 75, 76 & 77 5/8"-18 UNF-2A
A.F. ON HEX 5/8"-18 UNF-2A
THREADS
THREADS
Features: 4.31"
Model 76
Model 75 (110mm)
SPDT 4A contacts 1.00" (25mm)
A.F. ON HEX
Intrinsically Safe 3/4"-16 UNF-2A
THREADS
-400 to 2210F operating temperature .625"
(16mm)
Options:
Suitable for Zone 0, 1, or 2 explosion proof 1.15"
(29mm)
Model Contact Form Sensing Range Outlet Position Enclosure Material Approvals Wiring Options
Lead Wires 18 Gauge (.110" dia) potted-in PVC insulated AWM / TEW stranded lead wires, rated at 221OF (105OC)
Repeatability: .002" (.05mm) typical Contact Material: Palladium silver with Target Material: Ferrous steel Conduit Outlet: 1/2" NPT 600V UL / CSA listed
2 303 stainless steel A2 36" (914 mm)
sawtooth surface configuration
(rated 2,000 PSI) (Sensing A3 72" (1829 mm)
Response Time: 8 milliseconds Sensing Range: 2 Side entry with Teflon 2 High temperature to 400OF (204OC)
must be 3) A4 144" (3658 mm)
Form: SPDT, Form C .100 (3 mm) end sensing (2,000 PSI) insulated leads (Model 76) with TeflonTM insulated leads (Wiring A_ _ _ Lengths greater than 144" (Specify length in 5' increments (e.g. A150 = 150 ft. of leads))
Differential: Approx. .020" (.51 mm) .072 (2 mm) end sensing (5,000 PSI) (Approval must be 2 or 8) must be F)
Ratings: Resistive .060 (1.5 mm) end sensing (10,000 PSI) 3 HiPressure - 303 stainless 3 UL listed explosion proof for Cl I, Div Cable 18 Gauge (.250" dia.) potted-in PVC cable, rated at 176OF (80OC) 300V, UL / CSA listed
(Wiring must be F)
Operating Temperature: -40O to 221OF steel (rated 5,000 PSI) 1 & 2; Grps A,B,C,D; Cl II, Div 1 & 2, B2 36" (914 mm)
(-40O to 105OC). HiTemp to 400OF (204OC) AC DC
(Sensing must be 4) (Approval
B3 72" (1829 mm)
Sensing Range with Target Magnet: Grps E-G; Cl III (Model 75 & 77) (Wiring
Volts Amps Volts Amps 5 Bottom of enclosure B4 144" (3658 mm)
120 4 24 3 up to .35 (9 mm) must be 2, 7, 8, or 9) must be A, B, or F) (Lead seal req'd within 18") B_ _ _ Lengths greater than 144" (Specify length in 5' increments (e.g. B150 = 150 ft. of cable))
75 Model 75
5
/8" (16 mm) dia. x 45/16" (110 mm)
240 2 48 1.25 4 CSA certified explosion proof
125 0.5 3 Standard sensing - approx. .100" 4 HiPressure - 303 stainless for Cl I, Div 1; Grps A,B,C,D; Cl II, Water Resistant 18 Gauge ( .250" dia.) PVC cable rated at 176OF (80OC) 300V with water-resistant squeeze
long with 5/8"-18 UNF x 213/16" 250 0.5 connector. (Model 76) UL / CSA listed
(3 mm) end sensing (must be 2 or 6) steel (rated 10,000 PSI) Div 1; Grps E-G; Cl III (Model 75) (Wiring
(71 mm) threads and 1/2" NPT C2 36" (914 mm)
(Sensing must be 5) (Approval must be A, B, or F)(Lead seal req'd within 18")
conduit hub C3 72" (1829 mm)
1 Single Pole Double Throw (Form C) 4 HiPressure sensing - approx. must be 2, 7, 8, or 9) 6 CSA certified Cl I, Div 2; Grps C4 144" (3658 mm)
75M Model 75 .072" (2 mm) end sensing A,B,C,D; Cl II, Div 2; Grps E-G; Cl III C_ _ _ Lengths greater than 144" (Specify length in 5' increments (e.g. C150 = 150 ft. of cable))
(Model 75 & 77) (Wiring must be A, B, or F)
M18 x 1 external metric thread (Enclosure must be 3 or 7 and 6 316 stainless steel Quick Disconnect Male Quick Disconnect only, potted-in connector. (CSA requires a case ground) (Approvals must
(Lead seal req'd within 18")
Approvals must be 2, 3, 7, or 8) (rated 2,000 PSI) be 7 or 8)
76 Model 76 7 CSA certified General Purpose Mini-change Micro-change
5/8" (16 mm) dia. x 3 3/16" (81 mm)
8 UL listed General Purpose DCA 3 - pin Mini-change type DBA 3 - pin Micro-change type
5 HiPressure sensing - approx. 7 303 stainless steel
long with 5/8"-18 UNF x 213/16" DCD 4 - pin Mini-change type DBD 4 - pin Micro-change type
.060" (1.5 mm) end sensing (rated 3,500 PSI) (Approval 9 CENELEC: EExdIIC T6 Zone 1. DCG 5 - pin Mini-change type DBG 5 - pin Micro-change type
(71 mm) threads. No conduit hub (Model 75 & 77) (Wiring must be A or B)
(Enclosure must be 4 and Approvals must be 3)
must be 2, 7, or 8) SubSea Underwater Connector (Models 75 & 77) (Certified not to leak underwater)
76M Model 76 T ATEX Zone 1 EEx d IIC T6
3DD 3 pin 4DD 4 pin
(-20 to +50C), II 2G (Model 75 only)
M18 x 1 external metric thread 3DE 3 pin right-angle 4DE 4 pin right-angle
(For Hi Temp to +150 use Wiring H)
Extended Sensing Range with HiTemp Leads 18 gauge (.070" dia. potted-in TeflonTM insulated leads rated at 482oF (250oC) 600V UL / CSA
77 Model 77
listed
3/4" (19 mm) dia. x 5 13/16" (148 mm) External Target Magnets
F2 36" (914 mm)
long with 3/4"-16 UNF x 213/16" (See Accessories for External Target Magnets)
F3 72" (1829 mm)
(71mm) threads. Form C - SPDT F4 144" (3658 mm)
Magnet Sensing Differential F_ _ _ Lengths greater than 144" (Specify length in 5' increments feet (e.g. F150 = 150 ft. of leads))
AMP3 .20" .25"
HiTemp Leads 18 gauge (.070" dia. potted-in PeekTM insulated leads rated at 400oF (200oC) 600V UL / CSA listed
AMS4 .35" .15" (Approval must be T)
AMS7 .20" .05"
Ordering Guide H2 36" (914 mm)
H3 72" (1829 mm)
Fill in the boxes to create your H4 144" (3658 mm)
ordering number. H_ _ _ Lengths greater than 144" (Specify length in 5' increments (e.g. H150 = 150 ft. of leads))
Model Contact Form Sensing Range Outlet Position Enclosure Material Approvals Wiring Options
44 - 1 - 45
70 Series Approvals & Wiring 502.969.8000 Leverless Limit Switches
Agency Approvals Wiring Diagrams (male view)
Round Switches
3 Wire PVC & HiTemp Leads Mini-Change QDC - 5 Pin - SPDT
(2) (3) (4) (6) (7) (8) (9)
N/C Red Pin 1 N/O
Hi-Temp UL Cl. 1, CSA CSA CSA UL Cenelec
Div. 1 Cl. 1, Div. 1 Cl. 1, Div. 2 General General EExdIIC N/O Blue Pin 2 N/C
Termination Options
Purpose Purpose T6 Zone 1 COM Black Pin 3 GND
Terminations A & F Pin 4 Inactive
A - Potted PVC Leads X X X X X X
Pin 5 COM
B - Potted PVC Cable X X X X X X Termination DCG
Termination B
D - SubSeaTM Connector X X X X
SubSea - 3 Pin - Right Angle
F - HITempTM Leads X X X X X X
Pin 1 COM
X = Approvals Available Mini-Change QDC - 3 Pin Pin 2 N/O
Pin 3 N/O
Models 72, 74, 76 Non-Hazardous Hazardous
Termination DCA
SubSea - 4 Pin - Lock Sleeve
NEMA CLASSES 4 4X 6 6P 7 9
Pin 1 COM
A - Potted PVC leads X X Pin 2 N/O
Round Switches
Dimensions
5/8"-18 UNF-2A 1.00" (25mm)
Models 7G, 7H & 7I THREADS A.F. ON HEX
1"-14 UNF-2A
1.00" (25mm)
A.F. ON HEX
.820" THREADS
(21mm)
3.25"
(83mm)
Model Contact Form Sensing Range Outlet Position Enclosure Material Approvals Wiring Options
Repeatability: .002" (.05 mm) typical Contact Material: Palladium silver with Target Material: Ferrous steel Conduit Outlet: 1/2" NPT Stainless Steel type 303 SAA Lead Wires 20 Gauge (.100" dia) potted-in PVC insulated AWM / TEW stranded lead
sawtooth surface configuration wires, rated at 221OF (105OC) 300V UL / CSA listed
Response Time: 8 milliseconds Sensing Range: 5 Bottom of enclosure 2 303 stainless steel A2 36" (914 mm)
Form: SPDT Form C; DPDT Form CC .090 (2.3 mm) end sensing (2,000 PSI) 2 High temperature to 400OF (204OC) A3 72" (1829 mm)
. (rated 2,000 PSI)
Differential: Approx. 020" (.51 mm) with TeflonTM insulated leads (Wiring A4 144" (3658 mm)
Ratings: Resistive Sensing Range with Target Magnet: A_ _ _ Lengths greater than 144" (Specify length in feet (e.g. A150 = 150 ft. of leads))
must be F)
Operating Temperature: -40O to up to .20 (5 mm) 6 316 stainless steel
221OF (-40O to 105OC) (Option to 400OF) AC DC AC DC (rated 2,000 PSI) 3 UL listed explosion proof for Cl I, Div Cable 20 Gauge ( .215" dia) potted-in PVC cable, rated at 176OF (80OC) 300V, UL / CSA
Volts Amps Volts Amps Volts Amps Volts Amps 3 Standard sensing - approx. .090" 1 & 2; Grps A,B,C,D; Cl II, Div 1 & 2, listed
7G Model 7G 120 4 24 3 120 3 24 1
(2.3 mm) end sensing Grps E-G; Cl III (Model 7G & 7I only)
5
B2 36" (914 mm)
/8" (16 mm) dia. x 4" (101 mm) 240 2 48 * 240 1.5 48 *
(Lead seal req'd within 18") B3 72" (1829 mm)
long with 5/8"-18 UNF x 13/4" 480 * 120 0.5 480 * 120 0.5
(44 mm) threads and 1/2" NPT 250 0.5 250 0.1 4 CSA certified explosion proof B4 144" (3658 mm)
conduit hub SPDT DPDT for Cl I, Div 1; Grps A,B,C,D; Cl II, B_ _ _ Lengths greater than 144" (Specify length in feet (e.g. B150 = 150 ft. of cable))
Div 1; Grps E-G; Cl III (Model 7G & 7I)
7GM Model 7G Quick Disconnect Male Quick Disconnect only, potted-in connector. (CSA requires a case
1 Single Pole Double Throw (Form C) (Lead seal req'd within 18")
M18 x 1 external metric ground) (Approvals must be 7 or 8) (Model 7G and 7I) Refer to pp. 93-104 for mating cable
Hermetically Sealed (Model 7G)
thread 6 CSA certified Cl I, Div 2; Grps assemblies and Aura Light Adapters.
(Lead seal not required for hazardous
A,B,C,D; Cl II, Div 2; Grps E-G; Cl III
locations) Mini-change
7H Model 7H (Model 7G & 7I) (Lead seal req'd within
5/ 8" (16 mm) dia. x 31/4" (83 mm)
18") DCH 7-pin mini-change type
long with 5/8" - 18 UNF x 13/4" 2 Double Pole Double Throw
threads. No conduit outlet. (Form CC) 7 CSA certified General Purpose HiTemp Leads 20 gauge (19 strands at .08") potted-in TeflonTM insulated leads rated at
8 UL listed General Purpose 482oF (250oC) 600V UL / CSA listed (Approval must be 2, 3, 4, 6, 7, or 8)
7HM Model 7H F2 36" (914 mm)
M18 x 1 external metric 9 CENELEC: EExdIIC T6 Zone 1. F3 72" (1829 mm)
thread (EN 50 014 & EN 50 018, BASEEFA F4 144" (3658 mm)
Extended Sensing Range with Need Accessories? Certificate Ex89C1233X) (Model 7G & F_ _ _ Lengths greater than 144" (Specify length in feet (e.g. F150 = 150 ft. of leads))
7I Model 7I External Target Magnets 7I) (Wiring must be A or B)
See pp. 93-104 for:
1" (25 mm) dia. x 55/8" (148 mm) (See Accessories for External Target Magnets)
long with 1" - 14 UNF x 3" Range Extending A SAA: Ex s IIC T6 IP65; Cl I Zone 1 &
Form C - SPDT Form CC - DPDT
(76 mm) threads 1/2" NPT Magnet Sensing Differential Target Magnets 2; EX S IIC T6 IP65; Cl I Zone 0; DIP
conduit outlet Mounting Brackets Cl II (Intrinsically safe with entity
AMP3 .15" .30"
Connectors and more!
AMS4 .20" .30" approved barrier. Install per NEC Article
Ordering Guide 501.) (Model 7G & 7I) (Wiring must be A)
Fill in the boxes to create your
ordering number.
Model Contact Form Sensing Range Outlet Position Enclosure Material Approvals Wiring Options
48 - 3 5 - 49
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Model 7L 502.969.8000 Leverless Limit Switches
Round Switches
Dimensions
Model 7L GO Switch with LEDs
Model Contact Form Sensing Range Outlet Position Enclosure Material Approvals Wiring Options
Repeatability: .002" (.05 mm) typical Contact Material: Palladium silver with Target Material: Ferrous Conduit Outlet: 1/2" NPT Stainless Steel type 316 Lead Wires 18 Gauge (.110" dia) potted-in PVC insulated AWM / TEW stranded lead wires,
sawtooth surface configuration rated at 221OF (105OC) 600V UL / CSA listed
Response Time: 8 milliseconds Sensing Range: 0.100" nominal 5 Bottom of enclosure 6 316 stainless steel 8 C-UL listed General Purpose A2 36" (914 mm)
Form: SPDT, Form C (rated 2,000 PSI) A3 72" (1829 mm)
Differential: Approx. .020" (.51 mm)
E C-UL listed A4 144" (3658 mm)
Ratings: .25A @ 24VDC/120VAC 6 Standard sensing - approx. 0.100"
Class I, Div 2, All groups A_ _ _ Lengths greater than 144" (Specify length in feet (e.g. A150 = 150 ft. of leads))
Operating Temperature: -40O to 160OF Resistive (2.5 mm) end sensing
(-40OC to 71OC). Class II, Div 1 & 2, All groups
Class III Cable 18 Gauge (3 cond .250" dia; 4 cond .250" dia.) potted-in PVC cable, rated at 176OF
7LG Model 7LG (80OC) 300V, UL / CSA listed
5/8" (16 mm) dia. x 4 3/4" (121 mm) B2 36" (914 mm)
long, with 5/8"-18 UNF x 2.13" 1 Single Pole Double Throw (Form C) B3 72" (1829 mm)
(54 mm) threads and 1/2" NPT B4 144" (3658 mm)
conduit hub B_ _ _ Lengths greater than 144" (Specify length in feet (e.g. B150 = 150 ft. of cable))
7LR Model 7LR Quick Disconnect Male Quick Disconnect only, potted-in connector. (Approval must be 8)
5/8" (16 mm) dia. x 4 3/4" (121 mm)
Refer to pp. 93-104 for mating cable assemblies and Aura Light Adapters.
long, with 5/8"-18 UNF x 2.13"
(54 mm) threads and 1/2" NPT
Mini-change Micro-change
conduit hub
DCA 3 - pin Mini-change type DBA 3 - pin Micro-change type
DCD 4 - pin Mini-change type DBD 4 - pin Micro-change type
DCG 5 - pin Mini-change type DBG 5 - pin Micro-change type
Need Accessories?
Range Extending
Target Magnets
Mounting Brackets
Connectors and more!
Ordering Guide
Fill in the boxes to create your
ordering number.
Model Contact Form Sensing Range Outlet Position Enclosure Material Approvals Wiring Options
52 - - 53
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Model LPS 502.969.8000 Leverless Limit Switches
Dimensions
LPS: Linear Position Sensor
0.200 NOMINAL
1/2 NPT
CONDUIT JAM NUT
The Luminator LPS is specifically designed to OUTLET 2.21 1.75 1.18
provide position feedback on linear control LPS-DZ2RA2 .75
1.5 MIN
STROKE DISTANCE
MOUNTING FOR
STROKES GREATER
THAN 1-1/2
Enclosure: 3.96" x 1", 316 series stainless steel D (1) Hermetically sealed SPDT; Form C BriteLite: Triaxial LEDs A2 3 ft. 18 gauge potted-in lead wires
Magnetic Target: 1.05" x 0.65", 316 series stainless BriteLite Colors: Green or Red A3 6 ft. gauge potted-in lead wires
Without BriteLite: 1A/120VAC; 0.5A/24VDC
steel
With BriteLite: 0.25A/120VAC; 0.25A/24VDC Z1 Explosion Proof A4 12 ft. 18 gauge potted-in lead wires
Conduit Outlet: 1/2" NPT Zone 1 G Green BriteLite 360 triaxial LED visual position indicator (Z0 & Z2 only)
W (1) Hermetically sealed SPST; Form A Class I, Div 1 & 2, Groups A,B,C,D DCA 3-pin mini change quick disconnect
Operating Temperature: -40 to 160F (-40to 71C) Class II, Div 1 & 2, Groups E,F,G R Red BriteLite 360 triaxial LED visual position indicator (Z0 & Z2 only) (Z2 only unless installed I.S. per NEC Article 504)
Without BriteLite: 3A/120VAC; 2A/24VDC Class III
Environment (Visual Display option must be N) N No visual indication DCD 4-pin mini change quick disconnect
With BriteLite: 0.25A/120VAC; 0.25/24VDC
(Z2 only unless installed I.S. per NEC Article 504)
Zone 1 (Class I, Div 1): NEMA Type 4, 4X, 7 and 9
Zone 2 (Class I, Div 2): NEMA Type 4, 4X Z2 Non-Incendive
Zone 2
Class I, Div 2, Groups A,B,C,D
Class II, Div 1 & 2, Groups E,F,G
Class III
LPS Luminator Linear Position Sensor
Need Accessories?
See pp. 93-104 for:
Range Extending
Target Magnets
Mounting Brackets
Connectors and more!
Ordering Guide
Fill in the boxes to create your
ordering number.
Model Sensor Area Classification Visual Display Wiring
54 - 55
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Round Switches
Dimensions
Model 7A Pneumatic Proximity Switch
Features:
Pneumatic proximity switch 1.88" 1.12"
3 way air valve (48mm) (28mm)
THREE PUSH IN FITTINGS
1.5 SCFM nominal flow rate
2.50"
Up to 100 PSI operation (64mm)
Model Port Arrangement Sensing Range Port Position Enclosure Material Approvals Wiring Options
Repeatability: .002" (.05 mm) typical Ports: Three (pneumatic) Target Material: Ferrous steel 3 Three "push to release" fittings 2 303 stainless steel 1 Always a "1" 00 Straight "push to release" fittings
(For 5/32" O.D. tubing) (rated 2,000 PSI)
Operating Temperature: 0O to 350OF 7 Supply, Cylinder, and Exhaust Sensing Range: 90 Right-angle "push to release" fittings
(-20 to 180OC) .062 (1.6 mm) end sensing (2,000 PSI)
6 Brass base, stainless
Operating Pressure: 60-100 PSI steel body
(rated 2,000 PSI)
3 Standard sensing - approx. .062"
7A Model 7A
5/8" (16 mm) dia. x 3.25" (82 mm) (1.6mm) end sensing
long with 5/8"-18 UNF threads
Ordering Guide
Fill in the boxes to create your
ordering number.
Model Port Arrangement Sensing Range Port Position Enclosure Material Approvals Wiring Options
56 7A - 7 3 3 1 - 57
Cylinder Position Sensors
C ourtesy ofSteven Engineering, Inc. y 230 R yan W ay,South San Francisco,C A 94080-6370 y M ain O ffice:(650)588-9200 y O utside LocalArea:(800)258-9200 y w w w .stevenengineering.com
A LOOK INSIDE - MODEL 7C
TECHNOLOGY IN ACTION GO Switch Stroke-to-GO
Unoperated Operated
The center magnet simultaneously When the ferrous cushion of a cylinder
attracts the primary magnet and enters the sensing area of the switch,
repels the bias magnet, pushing the it attracts the primary magnet, which
connecting rod backward. As a pulls the connecting rod forward. As a Options Available Key Benefits
result, the common contact rests in result, the common contact snaps to
its unoperated position, closing a its operated position, closing the other - SPST or SPDT Stroke-to-GO cylinder position sensors
contact circuit. contact circuit. - HiTemp to 400F are simple and built to last.
- SubSea Submersible
When the target is removed the com- With only one moving part and no
mon contact automatically returns to
its original unoperated position.
metal-to-metal contact forcing it to
move, there is nothing to wear out!
60 61
C ourtesy ofSteven Engineering, Inc. y 230 R yan W ay,South San Francisco,C A 94080-6370 y M ain O ffice:(650)588-9200 y O utside LocalArea:(800)258-9200 y w w w .stevenengineering.com
Models 7C, 7D, 7E & 7F 502.969.8000 Leverless Limit Switches
Underwater capabilities
.525" (13mm)
Model Contact Form Sensing Range Outlet Position Enclosure Material Approvals Wiring Options
Repeatability: .002" (.05 mm) typical Contact Material: Palladium silver with Target Material: Ferrous steel 2 Side entry 360O adjustable Stainless Steel type 303 Lead Wires 18 Gauge (.110" dia) potted-in PVC insulated AWM / TEW stranded lead wires, rated at
sawtooth surface configuration (Wiring must be A, B, C, or F) 221OF (105OC) 600V UL / CSA listed
Response Time: 8 milliseconds Sensing Range: .090 (2.3 mm) 5 Stainless steel (rated 3,000 A2 36" (914 mm)
No conduit hub A3 72" (1829 mm)
Form: SPDT, Form C (with or without LED end sensing (3,000 PSI) (Recommended air PSI operating) (3 to 1 safety 2 High temperature to 400OF (204OC)
.
Differential: Approx. 020" (.51 mm) indication) Single Pole, Single Throw factor applies to standard with TeflonTM insulated leads A4 144" (3658 mm)
gap .015 - .040) 6 Side outlet 360O adjustable probe lengths) A_ _ _ Lengths greater than 144" (Specify length in feet (e.g. A150 = 150 ft. of leads))
(with or without LED indication) Form A or (Wiring must be F) (Contact form must
Operating Temperature: -40O to 160OF Form B with Quick Disconnect (Wiring
be 4, 7, or 8) Cable 18 Gauge (.250" dia.) potted-in PVC cable, rated at 176OF (80OC) 300V, UL / CSA listed
(-40O to 71OC) with LEDs -40O to 221OF must be D) (Approval must be 7)
O O TM
(-40 to105 C) without LEDs; HiTemp option 3 Standard sensing - approx. .090" B2 36" (914 mm)
Ratings: Resistive
(2.3 mm) end sensing 7 CSA certified General Purpose B3 72" (1829 mm)
to 400OF) (204OC) AC DC AC DC
7 Side outlet 360O adjustable
Volts Amps Volts Amps Volts Amps Volts Amps
B4 144" (3658 mm)
120 4 24 3 120 0.5 24 0.5 with 1/2" NPT conduit hub B_ _ _ Lengths greater than 144" (Specify length in feet (e.g. B150 = 150 ft. of cable))
7C Model 7C 240 2 48 * 240 0.5 48 0.5
8 UL listed General Purpose
(Wiring must be A, B, or F )
1.025 (26 mm) probe length 480 * 125 0.5 480 * 125 0.5 Water Resistant 18 Gauge (.250" dia.) PVC cable rated at 176OF (80OC) 300V with water-resistant
250 0.5 250 0.5 squeeze connector.
7D Model 7D Without LED's With LED's 8 Top outlet (Wiring must be C2 36" (914 mm)
1.250(32 mm) probe length 1 Single Pole Double Throw (Form C) SubSea) C3 72" (1829 mm)
2 Single Pole Single Throw (Form A) C4 144" (3658 mm)
(N/O output with bi-color LED indication) C_ _ _ Lengths greater than 144" (Specify length in feet (e.g. C150 = 150 ft. of cable))
7E Model 7E
2.062 (52 mm) probe length (Operating voltage: 24 - 120V AC/DC)
Quick Disconnect Male Quick Disconnect only, potted-in connector. (CSA requires a case ground)
(Optional voltage: 48 - 240V AC/DC)
(Approvals must be 7 or 8) Refer to pp. 93-104 for mating cable assemblies and Aura Light Adapters.
7F Custom probe lengths (Leakage current is 1.0mA)
1.000 (26 mm) - 5.000 3 Single Pole Single Throw (Form B) Mini-change Micro-change
(127 mm)* (N/C output with bi-color LED indication) DCA 3 - pin Mini-change type DBA 3 - pin Micro-change type
(Operating voltage: 24 - 120V AC/DC) DCD 4 - pin Mini-change type DBD 4 - pin Micro-change type
(Optional voltage: 48 - 240V AC/DC) DCG 5 - pin Mini-change type
*Probe lengths shorter than 1.000 (Leakage current is 1.0 mA)
4 Single Pole Double Throw (Form C) SubSea Underwater Connector (Outlet position must be 8)
require a taller upper switch housing Need Accessories?
(without LED) (No leakage) 3DD 3 pin, certified not to leak underwater
See pp. 93-104 for: 4DD 4 pin, certified not to leak underwater
5 Single Pole Double Throw (Form C)
3DE 3 pin right-angle, certified not to leak underwater
(with dual LEDs) (Operating voltage: 24
Range Extending 4DE 4 pin right-angle, certified not to leak underwater
- 240V AC/DC) (No leakage current) Target Magnets
7 Single Pole Single Throw (Form A) Mounting Brackets HiTemp Leads 18 gauge (.070" dia. potted-in TeflonTM insulated leads rated at 482oF (250oC) 600V UL /
N/O output w/o LED indication; No Connectors and more! CSA listed (Approval must be 2, 7, or 8)
leakage F2 36" (914 mm)
Ordering Guide 8 Single Pole Single Throw (Form B) F3 72" (1829 mm)
Fill in the boxes to create your N/C output w/o LED indication; No leakage F4 144" (3658 mm)
ordering number. F_ _ _ Lengths greater than 144" (Specify length in feet (e.g. F150 = 150 ft. of leads))
Model Contact Form Sensing Range Outlet Position Enclosure Material Approvals Wiring Options
62 - 3 5 - 63
C ourtesy ofSteven Engineering, Inc. y 230 R yan W ay,South San Francisco,C A 94080-6370 y M ain O ffice:(650)588-9200 y O utside LocalArea:(800)258-9200 y w w w .stevenengineering.com
Models 7C, 7D, 7E & 7F 502.969.8000 Leverless Limit Switches
S
troke-To-GO Switches provide precise end-of-stroke position indication on consult factory. Please follow these steps: MIN
1.015
MAX
1.040
LENGTH CODE
1.000 A1
MIN
2.365
MAX
2.390
LENGTH CODE
2.350 G1
MIN
3.715
MAX
3.740
LENGTH CODE
3.700 N1
pneumatic and hydraulic cylinders. Designed to exceed automotive industry 1. Measure dimension A from both ends of
1.040
1.065
1.065
1.090
1.025
1.050
*
A3
2.390
2.415
2.415
2.440
2.375
2.400
G2
G3
3.740
3.765
3.765
3.790
3.725
3.750
N2
N3
standards, the housing is machined from stainless steel bar stock to handle your cylinder or retrieve from specification 1.090
1.115
1.115
1.140
1.075
1.100
A4
A5
2.440
2.465
2.465
2.490
2.425
2.450
G4
G5
3.790
3.815
3.815
3.840
3.775
3.800
N4
N5
drawings.
pressures to 3,000 PSI operating (tested to UL's 3X burst requirement) while with- 1.140
1.165
1.165
1.190
1.125
1.150
A6
A7
2.490
2.515
2.515
2.540
2.475
2.500
G6
G7
3.840
3.865
3.865
3.890
3.825
3.850
N6
N7
standing the extreme external conditions such as weld slag, coolants, cutting fluids, 2. Locate the Min/Max range that dimension 1.190 1.215 1.175 A8 2.540 2.565 2.525 G8 3.890 3.915 3.875 N8
A falls within on the Custom Probe Length 1.215 1.240 1.200 A9 2.565 2.590 2.550 G9 3.915 3.940 3.900 N9
physical abuse and even high temperatures. Stroke-to-GO Switches incorporate the Chart. 1.240
1.265
1.265
1.290
1.225
1.250
B1
**
2.590
2.615
2.615
2.640
2.575
2.600
H1
H2
3.940
3.965
3.965
3.990
3.925
3.950
P1
P2
same 70 Series GO Switch mechanism that has been tested to over 200 million 3. Locate probe length requirement and Probe
1.290
1.315
1.315
1.340
1.275
1.300
B3
B4
2.640
2.665
2.665
2.690
2.625
2.650
H3
H4
3.990
4.015
4.015
4.040
3.975
4.000
P3
P4
mechanical cycles and field proven in the most rigorous applications. This unique Code in the next two Columns to the right. 1.340
1.365
1.365
1.390
1.325
1.350
B5
B6
2.690
2.715
2.715
2.740
2.675
2.700
H5
H6
4.040
4.065
4.065
4.090
4.025
4.050
P5
P6
design offers the greatest benefits in cylinder indication. 4. Enter the probe code into the corresponding
1.390
1.415
1.415
1.440
1.375
1.400
B7
B8
2.740
2.765
2.765
2.790
2.725
2.750
H7
H8
4.090
4.115
4.115
4.140
4.075
4.100
P7
P8
spaces of the Stroke-To-GO Part Number. 1.440 1.465 1.425 B9 2.790 2.815 2.775 H9 4.140 4.165 4.125 P9
1.465 1.490 1.450 C1 2.815 2.840 2.800 J1 4.165 4.190 4.150 R1
1.490 1.515 1.475 C2 2.840 2.865 2.825 J2 4.190 4.215 4.175 R2
Application Considerations 1.515 1.540 1.500 C3 2.865 2.890 2.850 J3 4.215 4.240 4.200 R3
Cylinder cushion must be ferrous. 1.540 1.565 1.525 C4 2.890 2.915 2.875 J4 4.240 4.265 4.225 R4
1.565 1.590 1.550 C5 2.915 2.940 2.900 J5 4.265 4.290 4.250 R5
1.590 1.615 1.575 C6 2.940 2.965 2.925 J6 4.290 4.315 4.275 R6
Air gap between switch sensing 1.615 1.640 1.600 C7 2.965 2.990 2.950 J7 4.315 4.340 4.300 R7
face and cushion should be .015" to .040 1.640 1.665 1.625 C8 2.990 3.015 2.975 J8 4.340 4.365 4.325 R8
(outside this range please consult factory). 1.665 1.690 1.650 C9 3.015 3.040 3.000 J9 4.365 4.390 4.350 R9
1.690 1.715 1.675 D1 3.040 3.065 3.025 K1 4.390 4.415 4.375 S1
1.715 1.740 1.700 D2 3.065 3.090 3.050 K2 4.415 4.440 4.400 S2
Largest diameter of target (cushion) should 1.740 1.765 1.725 D3 3.090 3.115 3.075 K3 4.440 4.465 4.425 S3
cover at least 75% of probe sensing face. 1.765 1.790 1.750 D4 3.115 3.140 3.100 K4 4.465 4.490 4.450 S4
1.790 1.815 1.775 D5 3.140 3.165 3.125 K5 4.490 4.515 4.475 S5
1.815 1.840 1.800 D6 3.165 3.190 3.150 K6 4.515 4.540 4.500 S6
Sensing face of Stroke-To-GO Switch 1.840 1.865 1.825 D7 3.190 3.215 3.175 K7 4.540 4.565 4.525 S7
must be at least .125" from piston rod for 1.865 1.890 1.850 D8 3.215 3.240 3.200 K8 4.565 4.590 4.550 S8
Unique Features 1.890 1.915 1.875 D9 3.240 3.265 3.225 K9 4.590 4.615 4.575 S9
proper switch reset. This may at times
1.915 1.940 1.900 E1 3.265 3.290 3.250 L1 4.615 4.640 4.600 T1
Application Considerations require an air gap distance greater than 1.940 1.965 1.925 E2 3.290 3.315 3.275 L2 4.640 4.665 4.625 T2
.040". 1.965 1.990 1.950 E3 3.315 3.340 3.300 L3 4.665 4.690 4.650 T3
Mechanical life: 1.990 2.015 1.975 E4 3.340 3.365 3.325 L4 4.690 4.715 4.675 T4
Cylinder cushion must be ferrous.
2.015 2.040 2.000 E5 3.365 3.390 3.350 L5 4.715 4.740 4.700 T5
>200,000,000 cycles Air gap between switch sensing For cushion diameters less than .50", air 2.040 2.065 2.025 E6 3.390 3.415 3.375 L6 4.740 4.765 4.725 T6
face and cushion should be .015" to .040" gap should be .015" to .025". 2.065 2.090 2.050 E7 3.415 3.440 3.400 L7 4.765 4.790 4.750 T7
Leakage current: 2.090 2.115 2.075 E8 3.440 3.465 3.425 L8 4.790 4.815 4.775 T8
(outside this range please consult factory).
Without LEDs - none Mounting hardware is 1/4"-20 grade 2.115 2.140 2.100 E9 3.465 3.490 3.450 L9 4.815 4.840 4.800 T9
Largest diameter of target (cushion) should 2.140 2.165 2.125 F1 3.490 3.515 3.475 M1 4.840 4.865 4.825 V1
cover at least 75% of probe sensing face. 8 socket head cap screw (included).
With LEDs - <1mA (SPST) 2.165 2.190 2.150 F2 3.515 3.540 3.500 M2 4.865 4.890 4.850 V2
Sensing face of Stroke-To-GO Switch must 2.190 2.215 2.175 F3 3.540 3.565 3.525 M3 4.890 4.915 4.875 V3
Voltage Drop: be at least .125" from piston rod for proper 2.215 2.240 2.200 F4 3.565 3.590 3.550 M4 4.915 4.940 4.900 V4
2.240 2.265 2.225 F5 3.590 3.615 3.575 M5 4.940 4.965 4.925 V5
Without LEDs - none switch reset. This may at times require an air 7F- _ _ 23658-DCA 2.265 2.290 2.250 F6 3.615 3.640 3.600 M6 4.965 4.990 4.950 V6
gap distance greater than .040". Custom Probe Standard Catalog
2.290 2.315 2.275 F7 3.640 3.665 3.625 M7 4.990 5.015 4.975 V7
SPDT w/ LEDs - l.0 volt For cushion diameters less than .50", air gap Probe Code Options
2.315 2.340 2.300 F8 3.665 3.690 3.650 M8 5.015 5.040 5.000 V8
2.340 2.365 2.325 F9 3.690 3.715 3.675 M9
With LEDs - 2.8 volts (SPST) should be .015" to .025".
EXAMPLE: If "A" = 2.900" then:
Temperature drift: none 1.375"
.547 - .562 dia.
for probe
Washdown: designed to withstand 1,000 PSI washdown and NEMA 1/4"-20 x 1/2" deep two "A" PROBE PROBE Bi-color LED
places LENGTH CODE indication (2) .266 dia. mtg.
MIN MAX
6P with Mini-Change type connector option Head/Cap
holes
Sensing probe .525/.520
2.890 2.915 2.875 J4 dia.
Underwater: rated to 10,000 PSI with deep sea connector option Piston
.688
Weld Field Immune: tested and exceeded General Motors EHS- 1.375 A
Rod
320 specifications. Testing Agency - Candid Logic
Air gap
Radio Frequency Interference (RFI): no affect at any frequency Dimension A is measured from the outside
Cylinder body
groove surface of the cylinder block to the Top
Cushion collar or sleeve
Spotface .906 min. dia. 32 Dead Center (TDC) of the ferrous cushion. (must be ferrous steel)
microinch finish Cap
Distance A may differ at each end.
Head
Figure 1
64 Cushion spear
(must be ferrous steel)
65
C ourtesy ofSteven Engineering, Inc. y 230 R yan W ay,South San Francisco,C A 94080-6370 y M ain O ffice:(650)588-9200 y O utside LocalArea:(800)258-9200 y w w w .stevenengineering.com
Stroke to GO Approvals & Wiring 502.969.8000 Leverless Limit Switches
Models 7C, 7D, 7E, 7F Non-Hazardous Hazardous 8 - SPST COM Black Black Black Black Black Black Black
Form B N/C Red Red Red Red Red Red Red
NEMA CLASSES 4 4X 6 6P 7 9 N/O w/o LED GND Green Green White White White White Green
X = Designed to meet respective NEMA specifications SPST, Form B, N/C PIN 4 GND 2
3
PIN 1 GND SPST, Form B, N/C
1
PIN 2 COM PIN 1 COM
66 67
C ourtesy ofSteven Engineering, Inc. y 230 R yan W ay,South San Francisco,C A 94080-6370 y M ain O ffice:(650)588-9200 y O utside LocalArea:(800)258-9200 y w w w .stevenengineering.com
Stroke to GO Wiring 502.969.8000 Leverless Limit Switches
SPST, Form A, N/O SPST, Form A, N/O SPST, Form A, N/O SPST, Form A, N/O SPST, Form A, N/O SPST, Form A, N/O
PIN 1 GND PIN 1 COM PIN 1 N/O PIN 1 COM PIN 1 COM PIN 1 COM
PIN 2 COM PIN 2 N/O PIN 2 Inactive PIN 2 N/O PIN 2 N/O PIN 2 N/O
PIN 3 N/O PIN 3 INACTIVE PIN 3 GND PIN 3 GND PIN 3 INACTIVE PIN 3 GND
SPST, Form B, N/C PIN 4 GND PIN 4 Inactive SPST, Form B, N/C PIN 4 GND SPST, Form B, N/C
PIN 1 GND SPST, Form B, N/C PIN 5 COM PIN 1 COM SPST, Form B, N/C PIN 1 COM
PIN 2 COM PIN 1 COM SPST, Form B, N/C PIN 2 N/C PIN 1 COM PIN 2 N/C
PIN 3 N/C PIN 2 INACTIVE PIN 1 Inactive PIN 3 GND PIN 2 INACTIVE PIN 3 GND
SPDT, Form C PIN 3 N/C PIN 2 N/C SPDT, Form C PIN 3 N/C SPDT, Form C
PIN 1 COM PIN 4 GND PIN 3 GND PIN 1 N/C PIN 4 GND PIN 1 COM
PIN 2 N/C SPDT, Form C PIN 4 Inactive PIN 2 COM SPDT, Form C PIN 2 N/O
PIN 3 N/O PIN 1 COM PIN 5 COM PIN 3 N/O PIN 1 COM PIN 3 N/C
Male View
68 69
C ourtesy ofSteven Engineering, Inc. y 230 R yan W ay,South San Francisco,C A 94080-6370 y M ain O ffice:(650)588-9200 y O utside LocalArea:(800)258-9200 y w w w .stevenengineering.com
Specialty Sensors
C ourtesy ofSteven Engineering, Inc. y 230 R yan W ay,South San Francisco,C A 94080-6370 y M ain O ffice:(650)588-9200 y O utside LocalArea:(800)258-9200 y w w w .stevenengineering.com
High Temperature - 10 Series 502.969.8000 Leverless Limit Switches
Dimensions
Model Contact Form Sensing Range Outlet Position Enclosure Material Approvals Wiring Options
Repeatability: .002" (.05 mm) Contact Material: Silver cadmium Target Material: Ferrous steel Contact Outlet: 1/2" NPT 2 Stainless steel SAA HiTemp Wire 18 gauge (.070") dia. potted-in TeflonTM insulated leads rated at 482oF (250oC)
600V UL / CSA listed
oxide, gold flashed
Response Time: 8 milliseconds Sensing Range: Approx. 3/8" (10mm) F2 36" (914 mm)
2 High temperature to 350OF
F3 72" (1829 mm)
Forms: SPDT standard (176OC) with TeflonTM insulated
F4 144" (3658 mm)
Differential: Approx. 5/16" (8 mm) leads; UL General Purpose F_ _ _ Lengths greater than 144" (Specify length in feet (e.g. F150 = 150 ft. of leads))
Ratings: Resistive Sensing Range with Target Magnet:
Operating Temperature: -40O up to 3 3/8" (86 mm) (max) B SAA: High Temp 350OF (176OC):
AC DC
to 350OF (-40O to 176OC). Volts Amps Volts Amps EX S IIC T6 IP65; Cl I Zone 1 &
120 10 24 3 1 Standard sensing - approx. 3/8" 2; EX S IIC T6 IP65; Cl I Zone 0;
11 Size: 11/2" (38 mm) square x 240 5 48 1 (10 mm) side sensing 1 Behind 2 Left of DIP Cl II (Intrinsically safe with entity
4 9/16 " (116 mm) overall. Add 1/2" 480 2.5 125 0.5 sensing sensing approved barrier. Install per NEC
(13 mm) for bottom conduit outlet 250 0.5 area area Article 501.) (Wiring must be F)
Range Extending
Target Magnets
Mounting Brackets
Connectors and more!
5 Bottom of enclosure
Form C - SPDT
Ordering Guide
Fill in the boxes to create your
ordering number.
Model Contact Form Sensing Range Outlet Position Enclosure Material Approvals Wiring Options
72 11 - 1 2 - 73
C ourtesy ofSteven Engineering, Inc. y 230 R yan W ay,South San Francisco,C A 94080-6370 y M ain O ffice:(650)588-9200 y O utside LocalArea:(800)258-9200 y w w w .stevenengineering.com
High Temperature - 80 Series 502.969.8000 Leverless Limit Switches
Sensing Sensing
Area Area
The GO Switch Model 81 HiTempTM leverless limit
switch is rated for continuous operation at 3500F. The
81 offers end sensing and an optional Double Pole 3.12" 4.38" 3.12"
Double Throw contact arrangement. The 81 is useful 79 mm 111 mm 79 mm
Model Contact Form Sensing Range Outlet Position Enclosure Material Approvals Wiring Options
Repeatability: .002" (.05 mm) Contact Material: Silver cadmium Target Material: Ferrous steel Conduit Outlet: 1/2 NPT. 2 Stainless steel SAA HiTemp Wire18 gauge (.070") dia. potted-in TeflonTM insulated leads rated at 482oF
oxide, gold flashed Two locations (250oC) 600V UL / CSA listed
Response Time: 8 milliseconds Sensing Range: Approx. 1/4" (6 mm) F2 36" (914 mm)
1 Side outlet 2 High temperature to 350OF (176OC)
Forms: DPDT Form CC, SPDT Form C F3 72" (1829 mm)
1
Differential: Approx. /4" (6 mm) Sensing Range with Target Magnet: with TeflonTM insulated leads
F4 144" (3658 mm)
Ratings: Resistive up to 3 7/8" (98 mm) (max) 5 Bottom of enclosure F_ _ _ Lengths greater than 144" (Specify length in feet (e.g. F150 = 150 ft. of
Operating Temperature: -40O B SAA: High Temp 350OF (176OC): EX
leads))
to 350OF (-40O to 176OC) 0 Approx. 1/4" (6 mm) end sensing S IIC T6 IP65; Cl I Zone 1 & 2; EX S
AC DC
Volts Amps Volts Amps
IIC T6 IP65; Cl I Zone 0; DIP Cl II
81 Size: 11/2" (38 mm) square x 120 10 24 3 (Intrinsically safe with entity approved
4 3/8" (111 mm) overall. Subtract 240 5 48 1 barrier. Install per NEC Article 501.)
1 480 2.5 120 0.5
/2" (13 mm) from length for side
250 0.5
conduit
74 81 - 0 2 - 75
C ourtesy ofSteven Engineering, Inc. y 230 R yan W ay,South San Francisco,C A 94080-6370 y M ain O ffice:(650)588-9200 y O utside LocalArea:(800)258-9200 y w w w .stevenengineering.com
High Temperature - Models 71 - 72 502.969.8000 Leverless Limit Switches
Features:
1.15
SPDT 4A contacts (29mm)
Intrinsically Safe
-400 to 4000F operating temperature 1.55"
(39mm)
.625"
(16mm)
.625"
Options: (16mm)
3.38"
English or Metric threads 1.55" 1.25 1/2"-14 NPT (86mm)
(39mm) (32mm) CONDUIT OUTLET
Mica glass lead wires rated over 8420F
3.93"
(100mm)
Model 71 Model 72
Model Contact Form Sensing Range Outlet Position Enclosure Material Approvals Wiring Options
Repeatability: .002" (.05 mm) typical Contact Material: Palladium silver with Target Material: Ferrous steel Conduit Outlet: 1/2" NPT 2 303 stainless steel SAA HiTemp Leads 18 gauge (.070" dia.) potted-in TeflonTM insulated leads rated at 482oF (250oC)
sawtooth surface configuration 600V UL / CSA listed
(rated 2,000 PSI)
Response Time: 8 milliseconds Sensing Range: Approx. .040" (1 mm) 2 Side entry (Model 72) F2 36" (914 mm)
2 High temperature to 400OF (204OC)
Form: SPDT, Form C end sensing F3 72" (1829 mm)
Differential: Approx. .020" (.51 mm) 6 316 stainless steel with TeflonTM insulated leads
5 Bottom of enclosure F4 144" (3658 mm)
Ratings: Resistive Sensing Range with Target Magnet: (rated 2,000 PSI)
F_ _ _ Lengths greater than 144" (Specify length in feet (e.g. F150 = 150 ft. of leads))
Operating Temperature: -40O to 400OF up to .15 (4mm) B SAA: High Temp 350OF (176OC): EX
(-40O to 204OC) AC DC S IIC T6 IP65; Cl I Zone 1 & 2; EX
Volts Amps Volts Amps
6 Standard sensing - approx. .040" S IIC T6 IP65; Cl I Zone 0; DIP Cl II
120 4 24 3
71 Model 71 (1 mm) end sensing (Intrinsically safe with entity approved
3/8" (10 mm) dia. x 3 15/16" (100 mm) 240 2 48 1.25
480 * 125 0.5 barrier. Install per NEC Article 501.)
long, with 3/8"-24 UNF x 11/2"
250 0.5
(38 mm) threads and 1/2"-14 NPT
conduit hub
1 Single Pole Double Throw (Form C)
71M Model 71
M12 x 1 external metric thread
72 Model 72
3
/8" (10 mm) dia. x 3 3/8" (86 mm)
long, with 3/8"-24 UNF x 11/2"
(38 mm) threads. No conduit hub
72M Model 72
M12 x 1 external metric thread
Extended Sensing Range with Need Accessories?
External Target Magnets
(See Accessories for External Target Magnets) See pp. 93-104 for:
Form C - SPDT
Range Extending
Magnet Sensing Differential Target Magnets
AMP3 .12" .07" Mounting Brackets
AMS4 .15" .10" Connectors and more!
AMS7 .13" .045"
Ordering Guide
Fill in the boxes to create your
ordering number.
Model Contact Form Sensing Range Outlet Position Enclosure Material Approvals Wiring Options
76 - - 77
71 1 6
C ourtesy ofSteven Engineering, Inc. y 230 R yan W ay,South San Francisco,C A 94080-6370 y M ain O ffice:(650)588-9200 y O utside LocalArea:(800)258-9200 y w w w .stevenengineering.com
High Temperature - Models 73 - 77 502.969.8000 Leverless Limit Switches
Model 73 Model 74
conveyors, and valve position monitoring on steam
1.00" (25mm)
valves and other high heat applications. 5/8"-18 UNF-2A
A.F. ON HEX 5/8"-18 UNF-2A
THREADS
THREADS
Features:
Model Contact Form Sensing Range Outlet Position Enclosure Material Approvals Wiring Options
Repeatability: .002" (.05mm) typical Contact Material: Palladium silver with Target Material: Ferrous steel Conduit Outlet: 1/2" NPT 2 303 stainless steel HiTemp Leads 18 gauge (.070" dia. potted-in TeflonTM insulated leads rated at 482oF
sawtooth surface configuration
SAA
(rated 2,000 PSI) (Sensing (250oC) 600V UL / CSA listed
Response Time: 8 milliseconds Sensing Range: Approx. 2 Side entry with Teflon 2 High temperature to 400OF (204OC)
must be 3) F2 36" (914 mm)
Form: SPDT, Form C .100 (2.5 mm) end sensing (2,000 PSI) insulated leads (Model 74) with TeflonTM insulated leads
Differential: Approx. .020" (.51 mm) F3 72" (1829 mm)
.072 (1.8 mm) end sensing (5,000 PSI) (Wiring must be F)
Ratings: Resistive 3 HiPressure - 303 stainless F4 144" (3658 mm)
.060 (1.5 mm) end sensing (10,000 PSI) 5 Bottom of enclosure
Operating Temperature: -40O to 400OF AC DC
steel (rated 5,000 PSI) F_ _ _ Lengths greater than 144" (Specify length in feet (e.g. F150 = 150 ft. of leads))
(-40O to 204OC) Volts Amps Volts Amps (Sensing must be 4) 4 CSA certified explosion proof for
Sensing Range with Target Magnet: Cl I, Div 1; Grps A,B,C,D; Cl II, Div 1;
120 4 24 3
up to .35 (9 mm) HiTemp Leads 16 gauge potted-in Peek insulated leads with silver plated copper
73 Model 73 240 2 48 1.25 Grps E-G; Cl III (Model 73) (Wiring
5
4 HiPressure - 303 stainless conductor rated at 500oF (260oC) 600V; UL / CSA listed
/8" (16 mm) dia. x 35/8" (92 mm) 480 * 125 0.5 must be H) (Rated 2980 (1480C)) (Lead seal
3 Standard sensing - approx. .100" steel (rated 10,000 PSI) H2 36" (914 mm)
long with 5/8"-18 UNF x 17/8" 250 0.5
req'd within 18")
(48 mm) threads and 1/2"-14 NPT (3 mm) end sensing (Enclosure (Sensing must be 5) H3 72" (1829 mm)
conduit hub must be 2 or 6) H4 144" (3658 mm)
73M M18 x 1.5 external metric thread 1 Single Pole Double Throw (Form C) 6 316 stainless steel 9 CENELEC: EExdIIC T3 Zone 1. H_ _ _ Lengths greater than 144" (Specify length in feet (e.g. H150 = 150 ft. of leads))
74 Model 74 4 HiPressure sensing - approx. (rated 2,000 PSI) (EN 50 014 & EN 50 018, BASEEFA
5
/8" (16 mm) dia. x 23/4" (70 mm) .072" (2 mm) end sensing Certificate Ex89C1233X).(Model 73 & 75)
long with 5/8"-18 UNF x 17/8" (Enclosure must be 3) (Wiring must be H)
(48 mm) threads. No conduit hub
74M M18 x 1.5 external metric thread 5 HiPressure sensing - approx. B SAA: High Temp 400OF (204OC): EX
75 Model 75 S IIC T3 IP65; Cl I Zone 1 & 2; EX S
.060" (2 mm) end sensing
5
/8" (16 mm) dia. x 45/16" (110 mm)
(Enclosure must be 4) IIC T3 IP65; Cl I Zone 0; DIP Cl II
long with 5/8"-18 UNF x 213/16"
(Intrinsically safe with entity approved
(71 mm) threads and 1/2" NPT
barrier. Install per NEC Article 501.)
conduit hub
75M M18 x 1.5 external metric thread
76 Model 76 Extended Sensing Range with Need Accessories?
5
/8" (16 mm) dia. x 3 3/16" (81 mm)
External Target Magnets
(See Accessories for External Target Magnets) See pp. 93-104 for:
long with 5/8"-18 UNF x 213/16"
(71 mm) threads. No conduit hub Form C - SPDT Range Extending
76M Model 76 Magnet Sensing Differential Target Magnets
M18 x 1.5 external metric thread AMP3 .20" .25" Mounting Brackets
AMS4 .35" .15" Connectors and more!
AMS7 .20" .05"
Ordering Guide
Fill in the boxes to create your
ordering number.
Model Contact Form Sensing Range Outlet Position Enclosure Material Approvals Wiring Options
78 - 1 - 79
C ourtesy ofSteven Engineering, Inc. y 230 R yan W ay,South San Francisco,C A 94080-6370 y M ain O ffice:(650)588-9200 y O utside LocalArea:(800)258-9200 y w w w .stevenengineering.com
High Temperature - Models 7G, 7H & 7I 502.969.8000 Leverless Limit Switches
Model Contact Form Sensing Range Outlet Position Enclosure Material Approvals Wiring Options
Repeatability: .002" (.05 mm) typical Contact Material: Palladium silver with Target Material: Ferrous steel Conduit Outlet: 1/2" NPT Stainless Steel type 303 2 High temperature to 400OF HiTemp Leads 20 gauge (19 strands at .08") potted-in TeflonTM insulated leads rated at
sawtooth surface configuration (204OC) with TeflonTM insulated 482oF (250oC) 600V UL / CSA listed (Approval must be 6, 7, or 8)
Response Time: 8 milliseconds Sensing Range: 5 Bottom of enclosure 2 303 stainless steel F2 36" (914 mm)
leads
Form: SPDT Form C; DPDT Form CC .090 (2.3 mm) end sensing (2,000 PSI) F3 72" (1829 mm)
. (rated 2,000 PSI)
Differential: Approx. 020" (.51 mm) F4 144" (3658 mm)
Ratings: Resistive Sensing Range with Target Magnet: F_ _ _ Lengths greater than 144" (Specify length in feet (e.g. F150 = 150 ft. of leads))
Operating Temperature: -40O to up to .20 (5 mm) 6 316 stainless steel
221OF (-40O to 105OC) (Option to 400OF) AC DC AC DC (rated 2,000 PSI)
Volts Amps Volts Amps Volts Amps Volts Amps 3 Standard sensing - approx. .090"
7G Model 7G 120 4 24 1 120 3 24 1
(2.3 mm) end sensing
5 8
/ " (16 mm) dia. x 4" (101 mm) 240 2 48 * 240 1.5 48 *
long with 5/8"-18 UNF x 13/4" 480 * 120 0.5 480 * 120 0.5
(44 mm) threads and 1/2" NPT 250 0.5 250 0.1
7HM Model 7H
M18 x 1.5 external metric
thread
Extended Sensing Range with Need Accessories?
7I Model 7I External Target Magnets
See pp. 93-104 for:
1" (25 mm) dia. x 55/8" (148 mm) (See Accessories for External Target Magnets)
long with 1" - 14 UNF x 3" Range Extending
(76 mm) threads 1/2" NPT Form C - SPDT Form CC - DPDT
Magnet Sensing Differential Target Magnets
conduit outlet Mounting Brackets
AMP3 .15" .30"
Connectors and more!
AMS4 .20" .30"
Ordering Guide
Fill in the boxes to create your
ordering number.
Model Contact Form Sensing Range Outlet Position Enclosure Material Approvals Wiring Options
80 - 3 5 - 81
C ourtesy ofSteven Engineering, Inc. y 230 R yan W ay,South San Francisco,C A 94080-6370 y M ain O ffice:(650)588-9200 y O utside LocalArea:(800)258-9200 y w w w .stevenengineering.com
High Temperature - Models 7C, 7D, 7E, & 7F 502.969.8000 Leverless Limit Switches
Dimensions
Model Contact Form Sensing Range Outlet Position Enclosure Material Approvals Wiring Options
Repeatability: .002" (.05 mm) typical Contact Material: Palladium silver with Target Material: Ferrous steel Conduit Outlet: 1/2" NPT Stainless Steel type 303 2 High temperature to 400OF (204OC) HiTemp Leads 18 gauge (.070" dia. potted-in TeflonTM insulated leads rated at
sawtooth surface configuration with TeflonTM insulated leads 482oF (250oC) 600V UL / CSA listed
Response Time: 8 milliseconds Sensing Range: .090 (2.3 mm) 2 Side entry 360O adjustable 5 Stainless steel (rated 3,000 F2 36" (914 mm)
Form: SPDT, Form C (with or without LED end sensing (3,000 PSI) (Recommended air PSI operating) (3 to 1
No conduit hub F3 72" (1829 mm)
Differential: Approx. .020" (.51 mm) indication) Single Pole, Single Throw
gap .015 - .040) safety factor applies to
(with or without LED indication) Form A or F4 144" (3658 mm)
7 Side outlet 360O adjustable standard probe lengths) F_ _ _ Lengths greater than 144" (Specify length in feet (e.g. F150 = 150 ft. of leads))
Operating Temperature: -40O to 400OF Form B
O O
(-40 to 204 C) without LEDs with 1/2" NPT conduit hub
3 Standard sensing - approx. .090"
Ratings: Resistive
7C Model 7C (2.3 mm) end sensing
AC DC
120 4 24 3
240 2 48 *
7D Model 7D 480 * 125 0.5
1.250(32 mm) probe length 250 0.5
Without LED's
7E Model 7E
2.062 (52 mm) probe length 4 Single Pole Double Throw (Form C)
(without LED) (No leakage)
7F Custom probe lengths
1.000 (26 mm) - 5.000
7 Single Pole Single Throw (Form A)
(127 mm)*
(N/O output w/o LED indication) (No
leakage)
Range Extending
Target Magnets
Mounting Brackets
Connectors and more!
Ordering Guide
Fill in the boxes to create your
ordering number.
Model Contact Form Sensing Range Outlet Position Enclosure Material Approvals Wiring Options
82 - - 83
3 5 2
C ourtesy ofSteven Engineering, Inc. y 230 R yan W ay,South San Francisco,C A 94080-6370 y M ain O ffice:(650)588-9200 y O utside LocalArea:(800)258-9200 y w w w .stevenengineering.com
Underwater Switches - 10 & 20 Series 502.969.8000 Leverless Limit Switches
Underwater Switches
SubSea Connector Delrin Lock Sleeves SubSea Right Angle Connector
11/21 SubSeaTM Switches with Delrin Lock Sleeve (mating cable sold separately) No lock sleeve required
Model Contact Form Sensing Range Outlet Position Enclosure Material Approvals Wiring Options
Repeatability: .002" (.05 mm) Contact Material: Silver cadmium Target Material: Ferrous steel Contact Outlet: 1/2" NPT Material: Stainless Steel SubSeaTM Underwater Connector Refer to pp. 93-104 for mating cable assemblies.
oxide, gold flashed
Response Time: 8 milliseconds Sensing Range: Approx. 3/8" (10mm) Pressure Rating: 200 PSI 3DD 3 pin, certified not to leak underwater (includes male/female DelrinTM lock
Forms: SPDT, DMDB 1 Behind sensing area 7 CSA certified General Purpose
standard; 9/16" (14mm) extended sleeves)
Differential: Approx. 5/16" (8 mm) sensing (Model 11) 2 Left of sensing area 2 304 Stainless steel 8 UL listed General Purpose
Ratings: Resistive
Operating Temperature: -40O to 221OF 4DD 4 pin, certified not to leak underwater (includes male/female DelrinTM lock
(-40O to 105OC).
AC DC 3 Right of sensing area sleeves)
Volts Amps Volts Amps 1 Standard sensing - approx. 3/8" 4 304 Stainless steel -
120 10 24 3 (10 mm) side sensing corrosion resistant
11 Size: 11/2" (38 mm) square x 5 Bottom of enclosure
240 5 48 1 coating (polyurethane) 3DE 3 pin right-angle, certified not to leak underwater
4 9/16 " (116 mm) overall. Add 1/2" 480 2.5 125 0.5
(13 mm) for bottom conduit outlet. 250 0.5
2 Extended sensing - approx. 9/16"
(14 mm) side sensing (Contact
4DE 4 pin right-angle, certified not to leak underwater
1
21 Size: 1 /2" (38 mm) square x Form must be 1 or 3) (Model 11)
3 13/16 " (97 mm) overall. Add 1/2" 1 Single Pole Double Throw (Form C) SubSea - 3 Pin - Lock Sleeve SubSea - 3 Pin - Right Angle
(13 mm) for bottom conduit outlet. Pin 1 N/C Pin 1 COM
Model Contact Form Sensing Range Outlet Position Enclosure Material Approvals Wiring Options
84 - - 85
C ourtesy ofSteven Engineering, Inc. y 230 R yan W ay,South San Francisco,C A 94080-6370 y M ain O ffice:(650)588-9200 y O utside LocalArea:(800)258-9200 y w w w .stevenengineering.com
Underwater Switches - 80 Series 502.969.8000 Leverless Limit Switches
Underwater Switches
SubSea Connector Delrin Lock Sleeves SubSea Right Angle Connector
81 SubSeaTM Switch with Delrin Lock Sleeve (mating cable sold separately) No lock sleeve required
Model Contact Form Sensing Range Outlet Position Enclosure Material Approvals Wiring Options
Repeatability: .002" (.05 mm) Contact Material: Silver cadmium Target Material: Ferrous steel Conduit Outlet: 1/2" NPT. Material: Stainless Steel SubSeaTM Underwater Connector Refer to pp. 93-104 for mating cable assemblies.
oxide, gold flashed Two locations. 3DD 3 pin, certified not to leak underwater (includes male/female DelrinTM lock sleeves)
Response Time: 8 milliseconds Sensing Range: Approx. 1/4" (6 mm) 4DD 4 pin, certified not to leak underwater (includes male/female DelrinTM lock sleeves)
Forms: DPDT Form CC, SPDT Form C 1 Side outlet 2 Stainless steel 7 CSA certified General Purpose
8DD 8 pin, certified not to leak underwater (includes male/female DelrinTM lock sleeves)
Differential: Approx. 1/4" (6 mm) Sensing Range with Target Magnet:
Ratings: Resistive 4 Stainless steel - 8 UL listed General Purpose 3DE 3 pin right-angle, certified not to leak underwater
up to 3 7/8" (98 mm) (max) 5 Bottom of enclosure
Operating Temperature: -40O to 221OF corrosion resistant 4DE 4 pin right-angle, certified not to leak underwater
(-40O to 105OC). AC DC
0 Approx. 1/4" (6 mm) end sensing coating (polyurethane)
Volts Amps Volts Amps
SubSea - 3 Pin - Lock Sleeve SubSea - 4 Pin - Lock Sleeve
120 10 24 3
81 Size: 11/2" (38 mm) square x Pin 1 N/C Pin 1 COM
240 5 48 1
4 3/8" (111 mm) overall. Subtract
1 480 2.5 120 0.5 Pin 2 COM Pin 2 N/O
/2" (13 mm) from length for side
250 0.5
conduit Pin 3 N/O Pin 3 N/C
Pin 4 GND
1 Single Pole Double Throw (Form C)
(Wiring must be 3DD, 4DD, 3DE or 4DE)
Pin 5 N/C2
Extended Sensing with Need Accessories? SubSea - 4 Pin - Right Angle
Pin 6 N/O2
External Target Magnets Pin 7 COM2
(See Accessories for External Target Magnets) See pp. 93-104 for: Pin 1 COM
Pin 8 Inactive
Pin 2 N/O
Form C - SPDT Form CC - DPDT Range Extending
Magnet Sensing Differential Pin 3 N/C
Target Magnets
AMP3 15/16" 3/4" Mounting Brackets Pin 4 GND
AMS4 1-3/8" 1-1/8" Connectors and more! 8 2
1
AMC5 3-7/8" 2-1/8" 7 3
Ordering Guide AMF6 2-3/4" 1-5/8" 6 4
ordering number.
Model Contact Form Sensing Range Outlet Position Enclosure Material Approvals Wiring Options
86 81 - 0 - 87
C ourtesy ofSteven Engineering, Inc. y 230 R yan W ay,South San Francisco,C A 94080-6370 y M ain O ffice:(650)588-9200 y O utside LocalArea:(800)258-9200 y w w w .stevenengineering.com
Underwater Switches - 70 Series 502.969.8000 Leverless Limit Switches
Underwater Switches
SubSea Connector Delrin Lock Sleeves SubSea Right Angle Connector
73-75-77 SubSeaTM Switches with Delrin Lock Sleeve No lock sleeve required
GO Switch Models 73, 75, and 77 SubSeaTM leverless limit switches are submersible to .50"
.55" .28"
as deep as 23,000 feet. With their solid, one-piece stainless steel housings, there is no Neoprene
means for water to penetrate the contact chamber. These models are useful when 1.39"
precision sensing is required, in applications such as valve position monitoring, pig .98"
1.11"
detection, pin placement detection, and cylinder position sensing on lock and dam gates,
military hatch doors, ships and vessels, and offshore oil platforms.
.94"
Top View
2.9" 1.00"
Features: Dia.
mated
SPDT 4 amp contacts length
End sensing to 0.100" Neoprene
1.22"
Options:
Neoprene
Optional submersion depth to 11,500 feet .65"
Optional submersion depth to 23,000 feet
.78"
Sensing range to .35" with target magnet
Straight or right angle SubSea connector .16"
.3" 1.00"
.75" Hex Side View
O-Ring 1.29"
Model Contact Form Sensing Range Outlet Position Enclosure Material Approvals Wiring Options
Repeatability: .002" (.05mm) typical Contact Material: Palladium silver with Target Material: Ferrous steel Conduit Outlet: 1/2-14 NPT Material: 303 Stainless Steel SubSea Underwater Connector Refer to pp. 93-104 for mating cable assemblies.
sawtooth surface configuration
Response Time: 8 milliseconds Sensing Range: 5 Bottom of enclosure 2 303 stainless steel 3DD 3 pin, certified not to leak underwater (includes male/female DelrinTM lock sleeves)
.100 (2.5 mm) end sensing (2,000 PSI) 7 CSA certified General Purpose
. Form: SPDT, Form C (rated 2,000 PSI) (Sensing
Differential: Approx. 020" (.51 mm) .072 (1.8 mm) end sensing (5,000 PSI)
must be 3) 4DD 4 pin, certified not to leak underwater (includes male/female DelrinTM lock sleeves)
.060 (1.5 mm) end sensing (10,000 PSI) 8 UL listed General Purpose
Operating Temperature: -40O to 221OF Ratings: Resistive
(-40O to 105OC) AC DC 3 HiPressure - 303 3DE 3 pin right-angle, certified not to leak underwater
Volts Amps Volts Amps
3 Standard sensing - approx. .100" stainless steel (rated 5,000
73 Model 73 120 4 24 3
5 8 (3 mm) end sensing (Enclosure must PSI) (Sensing must be 4) 4DE 4 pin right-angle, certified not to leak underwater
/ " (16 mm) dia. x 35/8" (92 mm) 240 2 48 1.25
75M Model 75 SubSea - 4 Pin - Right Angle SubSea - 4 Pin - Lock Sleeve
M18 x 1.5 external metric thread Pin 1 COM Pin 1 COM
Need Accessories? Pin 2 N/O Pin 2 N/O
77 Model 77
3 See pp. 93-104 for: Pin 3 N/C Pin 3 N/C
/4" (19 mm) dia. x 5 13/16"
Form C - SPDT Pin 4 GND Pin 4 GND
(148 mm) long with 3/4"-16 UNF x
Range Extending
213/16" (71mm) threads Target Magnets
Mounting Brackets
Connectors and more!
Ordering Guide
Fill in the boxes to create your Male View
Male View
ordering number.
Model Contact Form Sensing Range Outlet Position Enclosure Material Approvals Wiring Options
88 - 1 5 89
C ourtesy ofSteven Engineering, Inc. y 230 R yan W ay,South San Francisco,C A 94080-6370 y M ain O ffice:(650)588-9200 y O utside LocalArea:(800)258-9200 y w w w .stevenengineering.com
DEFENDER Turbine Valve Monitoring System 502.969.8000 Leverless Limit Switches
Model GO Switches Wiring Options P P
6:,7&+
PP 6:,7&+
% $
%/8( 5('
P P
48 Defender Turbine Valve Model 74-LLS: SPDT, environmentally 00 Male/Female Mil Spec Quick Disconnect with back shell connection to * ) ( ' &
5(' %/$&. %/8( 5(' %/$&.
6:,7&+
Monitoring System sealed, rated 4A @ 120VAC, 3A @ 1-1/4" flex conduit
6:,7&+ 1 0 / . - +
P P 6:,7&+
P P %/$&. %/8( 5('
24VDC, maximum 240 VAC or 240VDC, 01 Male/Female Mil Spec Quick Disconnect with 25 ft. of cable 5(' %/$&. %/8(
6:,7&+ : 9 8 7 6 5 3 6:,7&+
Heavy Duty 11 Gauge Steel with prewired HiTempTM Teflon lead 02 Male/Female Mil Spec Quick Disconnect with 50 ft. of cable %/8( 5('
%/$&. %/8( 5(' %/$&. %/8(
P P J I H G
Gray connection to 1-1/4" flex conduit ;81)% K %/$&. 5('
6:,7&+
%/8( %/$&.
Choose number of switches 04 Male/900 Female Mil Spec Quick Disconnect with 25 ft. of cable N M
P O
(minimum 1, maximum 10) 05 Male/900 Female Mil Spec Quick Disconnect with 50 ft. of cable *5((1
06 Male/450 Female Mil Spec Quick Disconnect with back shell P P
*5281'
P P P P P P P P
050000 Five Leverless Limit Switches
12 Male/Female Mil Spec Quick Disconnect with 75 ft. of cable
060000 Six Leverless Limit Switches P P
13 Male/900 Female Mil Spec Quick Disconnect with 100 ft. of cable
070000 Seven Leverless Limit Switches 16 Male/900 Female Mil Spec Quick Disconnect with 50 ft. of HiTempTM cable
080000 Eight Leverless Limit Switches PP P P
090000 Nine Leverless Limit Switches
100000 Ten Leverless Limit Switches $//02817,1*
+2/(6$5(
P P
Accessories
ACP48 DEFENDER Calibration Unit
P P
Only one unit is required to calibrate any quantity
of Defender Systems
P P
74-LLS Replacement GO Switch and Target Cam Package
P P
Ordering Guide
Fill in the boxes to create your
ordering number. P P
90 48 - - 91
_ _0000
C ourtesy ofSteven Engineering, Inc. y 230 R yan W ay,South San Francisco,C A 94080-6370 y M ain O ffice:(650)588-9200 y O utside LocalArea:(800)258-9200 y w w w .stevenengineering.com
Accessories
C ourtesy ofSteven Engineering, Inc. y 230 R yan W ay,South San Francisco,C A 94080-6370 y M ain O ffice:(650)588-9200 y O utside LocalArea:(800)258-9200 y w w w .stevenengineering.com
Quick Disconnects & Cordsets 502.969.8000 Leverless Limit Switches
Accessories
Quality-engineered connectors and cordsets make installation
and maintenance a snap.
Standard designs are shown, with custom connectors available
on special order.
Refer to the Wiring Options portion of each GO Switch Ordering
Guide for detailed information.
C ourtesy ofSteven Engineering, Inc. y 230 R yan W ay,South San Francisco,C A 94080-6370 y M ain O ffice:(650)588-9200 y O utside LocalArea:(800)258-9200 y w w w .stevenengineering.com
AURA Light Adapter 502.969.8000 Leverless Limit Switches
Accessories
Dimensions
TM
Aura Light Adapter
1.01
Red LED
LED Adapter Module R (2) Red LEDs for normally open (N/O) output 3 3-pin Mini-Change type connector 0 None
1 Contact Wash Circuit
ALA1 Aura Light Adapter for one contact (requires a load) G (2) Green LEDs for normally open (N/O) output 4 4-pin Mini-Change type connector
3-Pin 4-Pin
5-Pin
PIN 1 - N/O
PIN 2 - NOT USED
PIN 3 - GND
Ordering Guide PIN 4 - NOT USED
Fill in the boxes to create your PIN 5 - COM
ordering number.
Model Control Arrangement Connector Options
96 ALA 97
C ourtesy ofSteven Engineering, Inc. y 230 R yan W ay,South San Francisco,C A 94080-6370 y M ain O ffice:(650)588-9200 y O utside LocalArea:(800)258-9200 y w w w .stevenengineering.com
Target Magnets 502.969.8000 Leverless Limit Switches
Accessories
Target Magnets AMS7 Magnet/Stainless
Increase the Sensing Range of GO Switches
Magnet assembly. 2" (50 mm) x
1/2 " (13mm) 7/16 -20 UNC threads.
AMF6 Magnet
(Machinable)
Flexible sensing amplifier/external magnet. 3" (76 mm)
x 12" (305 mm) x 3/8" (10 mm) thick.
AMC5 Magnet/
Stainless Cover
AMC1 magnet molded into stainless cover
with mounting holes. 7/8" (22 mm) x
29/16" (65 mm) x 17/32 " (13 mm) thick
with 7/32 " (6 mm) holes.
Refer to individual GO
Switch models for
extended sensing
ranges with external
target magnets.
98 99
C ourtesy ofSteven Engineering, Inc. y 230 R yan W ay,South San Francisco,C A 94080-6370 y M ain O ffice:(650)588-9200 y O utside LocalArea:(800)258-9200 y w w w .stevenengineering.com
Mounting Brackets 502.969.8000 Leverless Limit Switches
Accessories
Standard mounting brackets are available to
cover most GO Switch installations. They are
designed to provide secure installation without
interfering with the operation of the switch.
Item Part Number & Description Item Part Number & Description
Heavy Duty Mounting ABS2 3 (76mm) x 3 1/4 (82mm) x 1/8 (3mm) thick Cover Plates AHB1 Brass; 1-1/2 (38mm) x 1-1/2 (38mm) x 1/8 (3mm)
Bracket stainless steel AHS2 Stainless steel; 1-1/2 (38mm) x 1-1/2 (38mm) x 1/8 (3mm)
Cover plate for 10 and 20 Series
Side mount bracket for 10 Series GO Switches.
GO Switches
Bottom mount cover plate/conduit for 10 AHB3 Brass; 1-1/2 (38mm) x 1-1/2 (38mm) x 1/8 (3mm)
and 20 Series GO Switches. Furnished with
gasket and screws
Universal Mounting Bracket ABS3 6 (152mm) x 1-1/2 (38mm) x 3/16 (5mm) stainless steel
for 10/20 Series Jam Nuts AHS7 (2) 3/8 nickel plated brass for Model 71 and 72 GO Switches
AHS8 (2) 5/8 nickel plated brass for Model 73-76, 7G and 7H GO Switches
Universal mounting bracket for 10 Nickel plated brass jam nuts AHS18 (2) 5/8 stainless steel for Model 73-76, 7G and 7H GO Switches
Series and 20 Series GO Switches for 70 Series GO Switches AHS9 (2) 3/4 stainless steel for Model 77 GO Switches
AHS16 (2) 1 nickel plated brass for Model 7I GO Switches
Combination Cover Plate ABB4 3 (76mm) x 1-1/2 (38mm) x 1/8 (3mm) thick brass
and Mounting Bracket
ABS5 3 (76mm) x 1-1/2 (38mm) x 1/8 (3mm) thick stainless steel Parker Seal Nut and Washer AHS13 3/8 zinc plated steel for Model 71 and 72 GO Switches
AHS14 5/8 zinc plated steel for Model 73-76, 7G & 7H GO Switches
Bottom mount for 10 or 20 Series GO
ThredSeal Kits for 70 Series AHS19 5/8 Viton for Model 73-76, 7G & 7H GO Switches
Switches
GO Switches. Zinc plated AHS15 3/4 zinc plated steel for Model 77 GO Switches
steel with nitrile rubber (standard) or AHS20 3/4 Viton for Model 77 GO Switches
Viton (hi-temp or hydraulic fluids AHS17 1 zinc plated steel for Model 7I GO Switches
Universal Mounting ABS6 10 gauge (.134) type 304 stainless steel
detergent) washer
Bracket for 80 Series
Heavy Duty L Mounting ABS9 1-1/4 (32mm) wide. 11 gauge (.120) thick non-magnetic
Bracket stainless steel
100 101
C ourtesy ofSteven Engineering, Inc. y 230 R yan W ay,South San Francisco,C A 94080-6370 y M ain O ffice:(650)588-9200 y O utside LocalArea:(800)258-9200 y w w w .stevenengineering.com
Mounting Kits 502.969.8000
Over the years, customers have asked us to mount our GO Switch leverless limit switches
Mounting Kits
NAMUR Mounting Kits
to just about every type and brand of valve and actuator on the planet.
The vast majority of rack and pinion valve actuators come
As a result, TopWorx has amassed over 1,200 different mounting kit designs. with an ISO/NAMUR mounting pattern. This worldwide stan-
dard provides a consistent bolt pattern and shaft height
regardless of the actuator brand. As a result, there is less
So whether your valve application is rotary or linear, NAMUR or non-NAMUR, in need for expensive, custom made mounting kits, making it
production or obsolete, TopWorx is sure to have a mounting kit that fits your need. easier and less expensive to mount topworks accessories.
Courtesy of Steven Engineering, Inc. ! 230 Ryan Way, South San Francisco, CA 94080-6370 ! Main Office: (650) 588-9200 ! Outside Local Area: (800) 258-9200 ! www.stevenengineering.com
Installation Principles 502.969.8000 Leverless Limit Switches
Installation Instructions
Installation Principle - Attachment of Conduit or Cable
Square Switches
Non-ferrous brackets/plates are The greater mass of target the Attach conduit or cable correctly
See individual switch
recommended (stainless steel or better for maximum contact Ordering Guides for wiring When using long runs of
aluminum). pressure, especially in low current diagrams and information on conduit or cable, place
applications. external target magnets for supports close to the switch to
increased sensing ranges.
GO Switches may be mounted on avoid pulling switch out of
ferrous materials but it is not For heavy or inductive loads, arc position.
recommended. Loss of sensing suppression devices, or If switch is mounted on a
range will result. interposing relays are recom- moving part, be sure flexible
mended for contact longevity. conduit is long enough to allow
It is recommended to mount Contact factory for specifics. for movement, and positioned
switches 1" to 1-1/2" away from to eliminate binding or pulling.
surrounding ferrous materials GO Switches may be mounted in For installation in hazardous
when possible. any plane. locations, check local electrical
codes. Switches must be
If mounting on ferrous material, When mounting GO Switches side installed according to local
insure uniform coverage of the by side, place 2-1/4" apart edge electrical codes.
switch, biasing the internal to edge, not center to center. In damp environments, use
magnet(s) equally. (Fig. 2) If 1/4" thick non-conductive RTV
magnets are biased unequal, Contact factory for side by side or a similar moisture barrier to
latching may occur. (Fig. 1) mounting. prevent water/condensation
from entering conduit hub
GO Switches sense ferrous
materials such as mild steel, 400
series and 17/4 stainless steel.
Figure 1 Figure 2
Incorrect Correct
Avoid contact between target and
switch. Configure mounting of
switch and/or target so that target Side view Sensing Area Sensing Area
passes within proximity range of
sensing area. Sensing range will
vary according to model number
and size (mass) of target used.
Ferrous steel mounting
plates
Target magnets, available
through TopWorx, will increase
the sensing range of the switch.
Reference sensing ranges in
corresponding sections through-
out the catalog.
106 107
Courtesy of Steven Engineering, Inc. ! 230 Ryan Way, South San Francisco, CA 94080-6370 ! Main Office: (650) 588-9200 ! Outside Local Area: (800) 258-9200 ! www.stevenengineering.com
Installation Principles 502.969.8000 Leverless Limit Switches
Installation Instructions
Satisfy these 3 criteria to reduce Contact arrangements vary according to type of switch. Refer to sections on each switch series for
ATTENTION!
detailed information. Be sure that electrical load will not exceed rated capacity of the switch.
possible premature failures For two-circuit switches (DMDB), contacts must be connected same polarity only in order to minimize Please refer to individual
Sealing switches possibility of a line-to-line short. switch sections for wiring
Incorrect Correct
In figure 1 something common has diagrams.
occurred; the conduit system has filled All GO Switches are "pure"contact switches, meaning that they have no voltage drop when closed,
with water. Over a period of time this may nor do they have any leakage current when open
open. For multi-unit installation, switches may be wired
Conduit
cause the switch to fail prematurely. Thread sealing
compound
in series or parallel, as shown below.
RTV
Figure 1 Figure 2
COM N/C N
C
Incorrect Correct
Bottom view
Two circuit (DMDB)
Bottom view
Target size Same polarity only
In figure 3, the ferrous target is too small to Sensing Sensing
Range
Range
be detected reliably.
Mild Series and Parallel Wiring
steel
In figure 4, the target has sufficient size Series Wiring
and mass for long term, reliable operation. Any number of GO Switches may be wired in series, without voltage drop drop. By contrast, conventional solid state switches have about two
volts drop across the switch when operated. With a system of 12 volts and four switches in series, 8 volts is dropped across the switches and only
4V is left to operate the load. When using GO Switches, 12V is still available to operate the load.
108 109
Courtesy of Steven Engineering, Inc. ! 230 Ryan Way, South San Francisco, CA 94080-6370 ! Main Office: (650) 588-9200 ! Outside Local Area: (800) 258-9200 ! www.stevenengineering.com
Installation Principles 502.969.8000 Leverless Limit Switches
Installation Instructions
Setting Up A 70 Series GOSwitch For Optimum Perf ormance
Performance Installation Principle -
Round Switches
GO Switch 70 Series end sensing switches use three permanent magnets and a push-pull plunger to control a set of mechanical contacts.
The center magnet simultaneously attracts the primary magnet and repels the bias magnet, pushing the connecting rod and common contact into the 70 Series GO Switches are For heavy or inductive loads,
See individual switch
normally closed position, closing a contact circuit. When a ferrous or magnetic target enters the sensing area of the switch, it attracts the primary inherently shielded, and are arc suppression devices, or Ordering Guides for wiring
magnet, which pulls the connecting rod and common contact into the normally open position, closing the other contact circuit. unaffected by surrounding interposing relays are recom- diagrams and information on
ferrous material, weld fields mended for contact longevity. external target magnets for
The sensing distance is the maximum distance between the switch and target when the switch first operates; the trip point. The difdifferential,
ferential, also increased sensing ranges.
and RF interference. Contact factory for specifics.
known as deadband or hysteresis, is the distance that the target must move from the sensing area in order to allow the switch to reset.
GO Switches sense ferrous Do not use excessive force on
The internal mechanism is shown here:
materials such as mild steel, 400 external threads when installing.
series and 17/4 stainless steel. (36 in/lbs. max)
Remember, there is no exact science to use when applying a GO Switch. However, once the switch is set, and the target travels to the same position
every time (within .002), the GO Switch will maintain calibration for life. Set it and fforget
orget it!
110 111
Courtesy of Steven Engineering, Inc. ! 230 Ryan Way, South San Francisco, CA 94080-6370 ! Main Office: (650) 588-9200 ! Outside Local Area: (800) 258-9200 ! www.stevenengineering.com
Installation Principles 502.969.8000 Leverless Limit Switches
Installation Instructions
Pressure Sealing Methods Factors Affecting Contact Life
GO Switch recommends the use of our
Parker ThredSeal Washer Kits in lieu of GO Switches are designed to provide optimum performance over a long period. Their premium grade components and inherently durable
other commercially available sealing design keeps them working, trouble-free, year after year. Some of the conditions that can decrease contact life are:
hardware. Provided with the Parker
ThredSeal Washer Kit are torque values Contact Erosion
for specific pressure ratings as well as There are two types of contact erosion, mechanical and electrical. Electrical contact erosion is caused by heavy electrical loads. The
the maximum torque values. contacts may overheat and become molten if there isn't sufficient off time to allow cooling between cycles. Mechanical erosion occurs as
GO Switch
a result of friction between contacts cycling at high speeds with little or no electrical load. Mechanical wear can also occur due to
operating a switch at a frequency higher than its design capability. The high operating speed of GO Switches make them ideal for almost
Jam Nut any application. For those with unusually high-frequency switching demands, please consult factory.
Flat Washer
GO Switch
Seal / Washer
Jam Nut Electrical wear caused by arcing, can be eliminated by utilizing high quality contact materials, such as the gold-flashed silver cadmium
Flat Washer
GO Switch
Cylinder oxide used in GO Switches, and by operating the switches within the voltage parameters for which they are designed. The use of arc
Cushion
Seal / Washer
Jam Nut suppressors such as resistor-capacitor combinations or blowout coils can also serve to prevent arcing, a consideration which is particularly
Cylinder
Cushion
Flat Washer important in certain hazardous operating environments.
Seal / Washer
Cylinder
Cushion Contact Transfer
Cylinder
Cylinder
rod When switches are operated above rated voltage or at high speeds, contact material can transfer from one contact to the other. For this
rod Cylinder
rod reason, it is important to observe the input voltage specifications supplied for each GO Switch.
Models 73-76 - 5/8" Diameter Models 71 & 72 - 3/8" Diameter Model 77 - 3/4" Diameter Welding or Sticking
Torque Jam Nuts to: Torque Jam Nuts to: Torque Jam Nuts to: The GO Switch design virtually eliminates welding or sticking due to mechanical armature hang-ups. Excessive voltage and the resultant
15 lbs-ft to achieve seal at 2,000 PSI 15 lbs-in to achieve seal at 2,000 PSI 20 lbs-ft to achieve seal at 2,000 PSI arcing, however, can cause overheating of the contacts and welding or sticking. By operating the GO Switch within its specified param-
25 lbs-ft to achieve seal at 5,000 PSI 30 lbs-in to achieve seal at 5,000 PSI 65 lbs-ft to achieve seal at 5,000 PSI
eters, this problem can be eliminated.
Do not exceed 30 lbs-ft Do not exceed 45 lbs-in Do not exceed 75 lbs-ft
Side Mount
Air and Hydraulic Cylinders
A ferrous cylinder cushion or piston will actuate Cylinder Cap
the switch. 70 Series GO Switch
70 Series GO Switch
Face Mount
112 113
Courtesy of Steven Engineering, Inc. ! 230 Ryan Way, South San Francisco, CA 94080-6370 ! Main Office: (650) 588-9200 ! Outside Local Area: (800) 258-9200 ! www.stevenengineering.com
NEC Codes 502.969.8000 Leverless Limit Switches
Installation Instructions
NEC 500-4 Protection Techniques for Hazardous Locations NEC 504 Intrinsically Safe Systems Definitions as referenced by NEC Article 100 current carrying capacity to prevent the buildup of voltages that
500-4(a) Explosionproof Apparatus 504-2 Definitions may result in undue hazards to connected equipment or to
500-4(e) Intrisically Safe Systems Associated apparatus Ampacity persons.
500-4(f)(2) Nonincendive Equipment Control drawing The current, in amperes, that a conductor can carry continuously
500-4(h) Hermetically Sealed Intrinsically safe apparatus under the conditions of use without exceeding its temperature La beled
Labeled
NEC 500-5(a) Class I Group Classifications Simple apparatus rating. Equipment or materials to which has been attached a label,
NEC 500-5(b) Class II Group Classifications 504-4 Equipment Approval symbol, or other identifying mark of an organization
NEC 500-7 Class I Locations Definitions 504-10 Equipment Installation Approved that is acceptable to the authority having jurisdiction and con-
500-7(a) Class, I, Division 1. 504-10(a) Control drawing Acceptable to the authority having jurisdiction. cerned with product evaluation, that maintains periodic inspection
500-7(b) Class I, Division 2 504-10(b) Location of production of labeled equipment or materials, and by whose
NEC 500-8 Class II Locations Definitions 504-20 Wiring Methods Bonding labeling the manufacturer indicates compliance with appropriate
500-8(a) Class II, Division 1 The permanent joining of metallic parts to form an electrically standards or performance in a specified manner.
500-8(b) Class II, Division 2 505 Class I, Zone 0, 1 and 2 Locations conductive path that will ensure electrical continuity and the
NEC 500-9 Class III Locations Definitions 505-3 Location and General Requirements capacity to conduct safely any current likely to be imposed. Listed
500-9(a) Class III, Division 1 505-3(a) Classification of locations Equipment, materials, or services included in a list published by an
500-9(b) Class III, Division 2 505-4 Protection Techniques Bonding jumper organization that is acceptable to the authority having jurisdiction
505-4(a) Flameproof d A reliable conductor to ensure the required electrical conductivity and concerned with evaluation of products or services, that
NEC 501-4 Wiring Methods 505-4(c) Intrinsically safe between metal parts required to be electrically connected. maintains periodic inspection of production of listed equipment or
501-4(a) Class I, Division 1 505-4(d) Type of protection n materials or periodic evaluation of services, and whose listing
501-4(b) Class I, Division 2 505-4(f) Increased safety e Device states that either the equipment, material, or services meets
NEC 501-5 Sealing and Drainage 505-4(g) Encapsulation m A unit of an electrical system that is intended to carry but not identified standards or has been tested and found suitable for a
501-5(a) Conduit Seals, Class I, Division 1 505-5 Reference Standards utilize electric energy. specified purpose.
(Conduit Seal Locations) 505-7 Grouping and Classification
501-5(b) Conduit Seals, Class I, Division 2 505-7(a) Group IIC Disconnecting Live parts
(Conduit Seal Locations) 505-7(b) Group IIB A device, or group of devices, or other means by which the Electric conductors, buses, terminals, or components that are
501-5(c) Class I, Divisions 1 and 2 (Seal Fitting Compliance) 505-7(c) Group IIA conductors of a circuit can be disconnected from their source of uninsulated or exposed and a shock hazard exists.
501-5(d) Cable Seals, Class I, Division 1 505-9 Zone Classification supply.
501-5(e) Cable Seals, Class I, Division 2 505-9(a) Class I, Zone 0 Nonincendive circuit
Table 5.1 Conduit and Cable Seal Requirements for 505-9(b) Class I, Zone 1 Dustproof A circuit, other than field wiring, in which any arc or thermal effect
Hazardous Locations 505-9(c) Class I, Zone 2 Constructed or protected so that dust will not interfere with its produced under intended operating conditions of the equipment, is
NEC 501-6 Switches, Circuit Breakers, Motor Controllers and Fuses. 505-10 Listing, Marking and Documentation successful operation. not capable, under specified test conditions, or igniting the
501-6(a) Class I, Division 1 505-10(a) Listing flammable gas, vapor, or dust-air mixture. See Section 500-4(f) for
501-6(b) Class I, Division 2 505-10(b) Marking Dusttight details regarding this protection method allowable in Class I and II,
501-6(1) Type Required 505-10(c) Documentation Constructed so that dust will not enter the enclosing case under Division 2 classified areas.
501-6(1)(a) Hermetic seal 505-15 Wiring Methods specified test conditions.
501-6(1)(b) Factory seal 505-15(a) Zone 0 Qualified person
501-6(1)(d) Solid state switch 505-15(b) Zone 1 Enclosure One familiar with the construction and operation of the equipment
NEC 501-7 Control Transformers and Resistors (Solenoids) 505-15(c) Zone 2 The case or housing of apparatusto prevent personnel from and the hazards involved.
NEC 501-12 Receptacles and Attachment Plugs, Class I, Divisions 1 & 2 505-20 Equipment accidentally contacting energized parts, or to protect the equip-
(Disconnect Plugs) 505-15(a) Zone 0 ment from physical damage. Rainproof
NEC 501-16 Grounding, Class I, Divisions 1 & 2 505-15(b) Zone 1 Constructed, protected, or treated so as to prevent rain from
505-15(c) Zone 2 Explosionproof aappara
ppara tus
pparatus interfering with the successful operation of the apparatus under
NEC 502-4 Wiring Methods Apparatus enclosed in a case that is capable of withstanding an specified test conditions.
502-4(a) Class II, Division 1 explosion of a specified gas or vapor that may occur within it and
502-4(b) Class II, Division 2 of preventing the ignition of a specified gas or vapor surrounding Raintight
NEC 502-5 Sealing, Class II, Divisions 1 & 2 the enclosure by sparks, flashes, or explosions of gas or vapor Constructed or protected so that exposure to a beating rainwill not
NEC 502-6 Switches, Circuit Breakers, Motor Controllers and Fuses within, and that operates at such an external temperature that a result in the entrance of water under specified test conditions.
502-6(a) Class II, Division 1 surrounding flammable atmosphere will not be ignited thereby.
502-6(a)(1) Type required Watertight
502-6(a)(2) Isolating Switches Ground Constructed so that moisture will not enter the enclosure under
502-6(a)(3) Metal dusts A conducting connection, whether intentional or accidental, specified test conditions.
502-6(b) Class II, Division 2 between an electrical circuit or equipment and the earth, or to
NEC 502-7 Control Transformers and Resistors (Solenoids) some conducting body that serves in place of the earth. Wea therproof
eatherproof
502-7(a) Class II, Division 1 Constructed or protected so that exposure to the weather will not
502-7(b) Class II, Division 2 Grounded interfere with successful operation.
Intentionally connected to earth through a ground connection or
114 connections of sufficiently low impedance and having sufficient 115
Courtesy of Steven Engineering, Inc. ! 230 Ryan Way, South San Francisco, CA 94080-6370 ! Main Office: (650) 588-9200 ! Outside Local Area: (800) 258-9200 ! www.stevenengineering.com
Applications
C ourtesy ofSteven Engineering, Inc. y 230 R yan W ay,South San Francisco,C A 94080-6370 y M ain O ffice:(650)588-9200 y O utside LocalArea:(800)258-9200 y w w w .stevenengineering.com
Applications 502.969.8000 Leverless Limit Switches
AUTOMOTIVE
Applications
EQUIPMENT Compacting NUCLEAR POWER PLANTS Igniters STEEL MILLS WASTE WATER TREATMENT
Chemical washdown areas On all equipment where Engraving Fuel transfer systems Louvered dampers Bullwheels Agitators
Conveyors the value of the switch is Freezing Valve position indication Master trip valves Cold rolling units Clarifiers
Cylinder end-of-stroke judged by its performance Gluing Pyrite gates Conveyors Clutches
indication and long life Heavy Equipment OFF ROAD EQUIPMENT Pulverizer and pulverizer Cranes Shower and eyewash
Eye wash stations (Komatsu, John Deere, Boom alignment valves Dampers stations
Marmac position sensing FLUID POWER Hyundia, etc.) Cranes Scrubber valves Draw benches Sluice gates
Paint incineration damper Cylinders Lubricators Cylinders Showers and eyewash Fans Valves
indication Valves Mixing Dump truck bed indication stations Hot mill applications
Paint mixing valves Printing Ore/coal pile reclaimers Soot blowers Shower and eyewash
Paint spray areas FOOD PROCESSING Other machinery dealing Steam valves stations
Part present indication Canning/bottling equipment with abrasive, explosive, OIL/GAS EXPLORATION Stokers Track monitors
Pneumatic and hydraulic Conveyors corrosive or otherwise Off-shore sites Stop control valves Valve position indication
clamping and welding Cylinder indication "hard to handle" environ- Sub-sea applications Turbine control valves
fixtures Freezers ments Valve position indication Ventilator valves TIRE AND RUBBER
Positioning and indexing Labelers Rock crushing Wallblowers Any machinery handling
Powerhouse (see Power Material handling PETROLEUM REFINING Water de-mineralization carbon black
Generation) Mixers MATERIAL HANDLING Interlocks valves Conveyors
Safety showers Ovens Baggers/Balers Motor phase monitoring Curing presses
Speed control on conveyors Packaging equipment Bulk loading/unloading Shower and eyewash PULP AND PAPER Cylinder end-of-stroke
Scales equipment stations Agitators indication
CEMENT PLANTS Showers and eyewash Conveyors Valve position indication Conveyors Shower and eyewash
Bagging stations Crating equipment Mixers stations
Chutes Valve position indication Labelers POWER GENERATION Shower and eyewash Tire mold closure inter
Conveyors Lifts Air preheaters stations locks
Crushers FOUNDRIES Packaging machines Air preheater blowers Speed monitors Tire scrivers
Hopper doors Conveyors Ash bins Valve position indication
Kilns Crane MILITARY/MARINE Ash handling valves TOOL & DIE
Loaders Dampers Ballast transfer pumps Bag houses RAILROADS Plastic injection molding
Machinery Ladle positioning Davits Barge unloaders Bridges (draw and swing) Aluminum die-casting
Packaging Mold positioning Elevators Blow down valves Car Maintenance Eqpt. Rubber molding
Valve position indication Shakers Elevator speed control Boiler feed pump recircula- Couplers High temperature
Showers and eyewash Hatch interlock tion valve Cranes applications
CHEMICAL PROCESSING stations Safety interlocks Boiler oil injectors Crossing gates
Emergency showers Shipboard cranes Bottom ash valves Track maintenance TRANSPORTATION
Eye wash stations GLASS Valve position indication Burner valves vehicles & machinery EQUIPMENT
Filters Conveyors Coal car dumpers Track manipulation Airport fuel transfer
Hose Couplings Limits in all high heat areas MINING Coal feeders equipment (Railway equipment
Transfer panels Mixers Any limit application Coal handling apparatus Technologies) Davits
Valve position indication Conveyors Coal pulverizing swing Hangar doors
LUMBER AND WOOD Cylinders valves SOLID WASTE DISPOSAL/ Hatch interlocks
CONSTRUCTION PRODUCTS Dump bed up indication Coal samplers CO-GENERATION K-Loaders
Concrete block mfg. Conveyors Longwall equipment Coal transport conveyors Conveyors Passenger jetways
Concrete ready mix Eyewash stations Shower and eyewash Conveyors Cranes Scissor lifts
trucks (counting revolu- Sawdust bins stations Dampers Dampers Shipboard cranes
tions of drum) Saws Track signal Damper valves Valve position indication Valve position indication
Cranes Ventilation equipment Economizers Ventilation equipment Vehicle interlocks
GAS TRANSMISSION/ Feedwater heater level
ELEVATORS/ESCALATORS MACHINERY DISTRIBUTION detection
Leveling switch in mining Car wash Door security Fly ash valves
elevators Commercial laundry Valve position indication Hopper gates
118 119
C ourtesy ofSteven Engineering, Inc. y 230 R yan W ay,South San Francisco,C A 94080-6370 y M ain O ffice:(650)588-9200 y O utside LocalArea:(800)258-9200 y w w w .stevenengineering.com
Applications 502.969.8000 Leverless Limit Switches
Applications
SOOT BLOWER POSITION INDICATION AUTOMOTIVE SKID CONVEYOR INDICATION
Automotive manufacturers need reliable position indication of body skids along the skid conveyor system. The critical areas are at
Wherever power is generated, whether it is at a power generation station or a pulp and paper facility, soot blowers are used the entrance, exit, and even inside of the paint-drying ovens where temperatures can reach close to 400oF. Mechanical limit
to eliminate slag buildup from the inside wall of a boiler. The lance of the soot blower penetrates the side of the boiler wall switches and inductive proximity switches cannot withstand the heat or the physical abuse of this application. Fortunately...
and extends inside. As it enters the boiler, the lance rotates in a clockwise motion spraying high pressure steam from the
end of the lance back toward the boiler wall. This high pressure spray removes the slag in a circular pattern that enlarges GO Switch has the answer.
as the lance extends further into the boiler. After the lance is fully extended, it retracts and rotates counter-clockwise to its
original inactive state until a predetermined time when the process starts again. Depending on the size of the boiler, there We recommend our stainless steel high temperature 10 Series GO Switch with extended sensing, and a 400oF continuous
can be as many as 60 soot blowers to service one boiler! temperature rating.
As you might imagine, the area in which the soot blowers operate is a demanding environment. High temperature and The GO Switch will provide reliable maintenance-free position indication in this tough application.
physical abuse make mechanical limit switches a constant maintenance headache. If a soot blower is out of service, the
boiler wall is not being cleaned and as a result, power is not being generated efficiently. Translation: downtime, mainte- Contact the paint shop supervisor, electrical engineers, and/or maintenance people responsible for the paint booth. They will be
nance costs and lost revenue. glad you called!
Fortunately, GO Switch has the solution. Each soot blower can be retrofitted using two Double Pole, Double Throw 80
Series GO Switches and one (1) AMS4 target magnet. As the soot blower lance extends and retracts into the boiler, the
target magnet travels to the sensing area of each GO Switch, providing maintenance-free, fit and forget position indication.
The GO Switch is wired like a mechanical switch so existing wiring can be used for easy installation. Since the GO Switch
does not depend on lever arms or internal moving parts, maintenance is immediately eliminated. This has been field tested
and proven in thousands of applications already.
Paint
Sootblower Dryer
Enclosure Oven
Lance
Guide
Rail
Skid
Spray
Nozzle Guide
AMS4 Rail
Target Magnet
1/4"
GO
Teflon
Switches
Boiler Plate
GO
Switch
S.S. Mtg.
Bracket
GO Switch
w/ QDC
120 121
C ourtesy ofSteven Engineering, Inc. y 230 R yan W ay,South San Francisco,C A 94080-6370 y M ain O ffice:(650)588-9200 y O utside LocalArea:(800)258-9200 y w w w .stevenengineering.com
Applications 502.969.8000 Leverless Limit Switches
Applications
GRAIN BIN OPEN/CLOSED GATE POSITION BAR SCREEN TRASH RAKES FOR WATER TREATMENT
Grain elevators need an explosion-proof sensing device to signal when the slide gate of a grain bin is fully closed. This Bar screens are typically used in the intake channels of water treatment plants to remove solid debris from the water to prevent
permits grain to be fed into the bin without waste. damage of subsequent equipment. When debris has accumulated on the screen, cleaning is required. It is done with a trash
rake that is usually mounted in front of the screen on a support frame. Some of these trash rakes are manually operated and
The switch not only had to be explosion-proof, but also had to withstand dirty and dusty conditions. most are motor propelled so an operator only has to push a button to activate the rake. Some are activated by a timer. The rake
goes through a cycle descending in front of the screen to the bottom moving towards the screen and then moving upward
A GO Switch was mounted on a stainless steel bracket, 1/4" below the moving rack drive. This allows 1/8" of play in the transporting the accumulated debris to a discharge chute where a container or a conveyor takes it away.
drive movement, while providing accurate sensing of the position of the bin gate.
The motor operated trash rakes usually have two limit switches on them mounted to the support frame well above the water
The dependable GO Switch costs less than other explosion-proof limit switches. level. The end-of-travel limit switch defines the exact position at which the assembly will stop at the end of the cycle. The
overload protection switch is activated when the rake comes in contact with an obstruction in the screen too large for it to
remove.
Stainless steel 10 series or 80 series are the best limit switches for these applications. The harsh and moist environments in
water treatment plants are too much for mechanical or solid state switches. Often the switches must be explosion proof and
magnets must be used as targets because of the variation in the traveling rake position.
GRAIN BIN
RACK DRIVEN
SLIDE GATE
GO Switch
122 123
C ourtesy ofSteven Engineering, Inc. y 230 R yan W ay,South San Francisco,C A 94080-6370 y M ain O ffice:(650)588-9200 y O utside LocalArea:(800)258-9200 y w w w .stevenengineering.com
Applications 502.969.8000 Leverless Limit Switches
Applications
REFUSE TRUCKS SAFETY SHOWERS AND EYEWASH STATIONS
Refuse trucks have as few as three switches and as many as ten switches per truck. The most common competitive
switches used are mechanical lever-arm and push-button limit switches. Some trucks incorporate electronic proximity In an emergency first-aid is crucial and according to the OSHA Plant Safety regulations; Subpart G-Occupational Health and
sensors. Environmental Control; Section 1910.94, Paragraph (d) (9) (vii):
Limit switch/sensor failures are prevalent in the refuse collection business. These switch/sensor failures are attributed (vii) Near each tank containing a liquid which may burn, irritate, or otherwise be harmful to the skin if splashed upon the
to mechanical wear and tear, moisture-ingression, corrosion and temperature extremes. workers body, there shall be a supply of clean cold water. The water pipe (carrying a pressure not exceeding 25 pounds) shall
be provided with a quick opening valve and at least 48 inches of hose not smaller than three-fourths inch, so that no time may
Vehicles out of service for any period of time cause lost revenue. be lost in washing off liquids from the skin or clothing. Alternatively, deluge showers and eye flushes shall be provided in cases
where harmful chemicals may be splashed on the body.
GO Leverless Limit Switches will prevent these failures and downtime while reducing maintenance costs.
Deluge Showers and eye flushes are plentiful in chemical processing facilities How are the proper personnel notified should an
Visit the refuse collection companies in your area. They will be glad you called! emergency occur? Flow switches are used, but have corrosion and freezing problems.
LS1 = Normally open: held closed when side door is closed and latched. GO Switch has the answer.
LS2 = (7 & 8 normally closed) (1 & 2 normally open): switches at end of packer stroke.
LS3 = Normally closed: opens when tailgate is latched. The GO Switch VIP for deluge showers and eye flushes can be mounted on any new or existing unit. Using the GO DPDT 80
LS4 = Normally closed: opens when tailgate is latched. Series switch allows for flexibility in signalling the proper personnel. For example, when the shower or eye flush valve is opened
LS5 = Normally closed: opens when packer is fully retracted. the GO Switch can signal the central control room and first-aid personnel simultaneously, or signal the control room and sound
LS6 = Normally open: (1 & 2 normally open) (5 & 6 normally open): closes when arms are above cab. an alarm. When personal injury occurs time is of the essence.
LS7 = Normally closed: opens when top door opens.
LS7 LS1
EYEWASH
124 125
C ourtesy ofSteven Engineering, Inc. y 230 R yan W ay,South San Francisco,C A 94080-6370 y M ain O ffice:(650)588-9200 y O utside LocalArea:(800)258-9200 y w w w .stevenengineering.com
Reference Material
Courtesy of Steven Engineering, Inc. ! 230 Ryan Way, South San Francisco, CA 94080-6370 ! Main Office: (650) 588-9200 ! Outside Local Area: (800) 258-9200 ! www.stevenengineering.com
NEMA Definitions 502.969.8000 Leverless Limit Switches
Reference Material
Approval Agencies This group defines the options or approvals which may be required for a particular
Type 1 General Purpose indoor accidential contact (cage or skeleton) will not rust application. Safety requirements, the demands of the machinery on which the switch
will be used, or the type of environment will all play a role in determining the type of
approval needed.
Type 2 Drip-proof indoor limited amounts of falling water and dirt (not dust-tight) will not rust
Type 3 Dust-tight, rain-tight outdoor windblown dust, rain, sleet, and undamaged by external ice formation
Underwriters Laboratories (UL) Our file number is E79070 for
same as type 3 above, plus diverts water from live parts, provision for hazardous location switches and E81878
Type 3R Dust-tight, rain-tight outdoor DEMCO (Subsidiary of UL) for general purpose switches.
drainage, will not rust
indoor/ temporary entry of water during limited submersion (6 ft. for 30 min),
Type 6 Water-tight, dust-tight
outdoor undamaged by formation of ice, will not rust Canadian Standard Our file number is LR-24226, (CSA) which
Association (CSA) includes most GO Switches except special
indoor/ models.
Type 6P Water-tight/dust-tight same as type 6 above plus prolonged submersion at 6 psig, will not rust
outdoor
Explosion proof Hazardous locations: protection against corrosive effects of liquids and
Type 7 indoor Standards Association of Australia (SAA) Our file number is EL/29:78062/M90
Cl I, Gps A, B, C, D gases
Ex109.
Explosion proof indoor/ Hazardous locations: protection against corrosive effects of liquids and
Type 8
Cl I, Gps A, B, C, D outdoor gases; contacts or connections immersed in oil
British Approvals Service for Our file number is Ex 89C1233X for use in
Explosion proof Electrical Equipment in Flammable Zone 1 Hazardous areas.
Type 9 indoor Hazardous locations: dust-tight, hazardous dust
Cl II, Gps E or G Atmospheres (BASEEFA) (Cenelec)
Type 10 Hazardous Locations indoor (MSHA) Mine Safety and Health Adm. per 30 C.F.R., Part 18
fibers, lint, dust and light splashing, seeage, and dripping condensation of
Type 12 Oil-tight/Dust-tight indoor
non-corrosive liquids
Type 12K Oil-tight/Dust-tigh indoor same as type 12 above, enclosure has knockouts
Type 13 Oil-tight/Dust-tight indoor dust, spraying of water, oil and corrosive coolant, oil resistant gaskets
128 73 129
Courtesy of Steven Engineering, Inc. ! 230 Ryan Way, South San Francisco, CA 94080-6370 ! Main Office: (650) 588-9200 ! Outside Local Area: (800) 258-9200 ! www.stevenengineering.com
Hazardous Locations 502.969.8000 Leverless Limit Switches
Reference Material
UL Hazardous Locations UL Hazardous Locations
Class I Class II Class III Class I, Division 1 & 2 Protection Methods
Flammable Gases, Vapors or Liquids Combustible Dusts Ignitable Fibers & Flyings
Applicable Certification Documents
Class I Area Classification Class II Area Classification Class III Area Classification Area Protection U.S. Canada
Division 1: Zone 0: Division 1: Division 1: Division 1 Explosion proof UL 1203 CSA-30
Where ignitable Where ignitable Where ignitable concentrations of Where easily ignitable fibers or materials Intrinsically safe (2 fault) UL 913 CSA-157
concentrations of concentrations of combustible dusts can exist all of the producing combustible flyings are handled, Purged/pressurized (Type X or Y) NFPA 496NFPA 496
flammable gases, flammable gases, time or some of the time under normal manufactured or used.
vapors, or liquids can vapors or liquids can operating conditions. Division 2 Non-incendive UL 1604 CSA-213
exist all of the time or exist all of the time Non-sparking device UL 1604 CSA-213
some of the time or long periods of Purged/pressurized (Type Z) NFPA 496NFPA 496
under normal time under normal Hermetically sealed UL 1604 CSA 213
operating operating conditions. Any Class I, Div. 1 method --- ---
conditions. Any Class I, Zone 1 or 2 method --- ---
Zone 1:
Where ignitable
Class I, Zone 0, 1 & 2 Protection Methods
concentrations of
flammable gases,
Applicable Certification Documents
vapors or liquids can Area Protection U.S. Canada IEC Europe
exist some of the Zone 0 Intrinsically safe, 'ia' (2 fault) UL 2279, Pt. 11 CSA-E79-11 IEC 60079-11 EN50020
time under normal Class I, Div. 2 Intrinsically
operating conditions. safe, (2 fault) method UL 913 CSA-157 --- ---
Class I Temperature Codes Class II Temperature Codes Class III Temperature Codes
Division 1 & 2 Zone 0, 1 & 2 Division 1 & 2 Division 1 & 2
T1 (<450oC) T1 (<450oC) T1 (<450oC) T3B, T3C
T2 (<300oC) T2 (<300oC) T2 (<300oC) (<165oC, <160oC)
T2A, T2B, T2C, T2D T2A, T2B, T2C, T2D T4 (<135oC)
(<280oC, <260oC, (<280oC, <260oC, <230oC, <215oC) T4A (<120oC)
<230oC, <215oC) T5 (<100oC)
T3 (<200oC) T3 (<200oC) T3 (<200oC) T6 (<85oC)
T3A, T3B, T3C T3A, T3B, T3C
(<180oC,<165oC, <160oC) (<180oC, <165oC, <160oC) Note: Article 503 of the NEC limits the
T4 (<135oC) T4 (<135oC) T4 (<135oC) maximum temperature codes for Class III
T4A (<120oC) T4A (<120oC) equipment to 165oC for equipment not
T5 (<100oC) T5 (<100oC) T5 (<100oC) subject to overloading and to 120oC for
T6 (<85oC) T6 (<85oC) T6 (<85oC) equipment that may be overloaded.
130 131
Courtesy of Steven Engineering, Inc. ! 230 Ryan Way, South San Francisco, CA 94080-6370 ! Main Office: (650) 588-9200 ! Outside Local Area: (800) 258-9200 ! www.stevenengineering.com
Hazardous Locations 502.969.8000 Leverless Limit Switches
Reference Material
UL Hazardous Locations UL Hazardous Locations
Class II, Division 1 & 2 Protection Methods Class III, Division 1 & 2 Protection Methods
Applicable Certification Documents Applicable Certification Documents
Area Protection U.S. Canada Area Protection U.S. Canada
Division 1 Dust-ignition proof UL 1203 CSA-25 or CSA-E-1241-1-1 Division 1 Dust-tight UL 1604 CSA-157
Intrinsically safe UL 913 CSA-157 Intrinsically safe UL 913 CSA-157
Pressurized NFPA 496 NFPA 496
Division 2 Dust-tight UL 1604 CSA-157
Division 2 Dust-tight UL 1604 CSA-157 or CSA-E-1241-1-1 Intrinsically safe UL 913 CSA-157
Non-incendive UL 1604 ---
Non-sparking UL 1604 ---
Pressurized NFPA 496 NFPA 496
UL's Hazardous Locations Standards
Any Class II, Div. 1 method --- ---
ANSI/UL 674 Electric motors and generators for use in Division 1 hazardous (classified) locations.
Hazardous Locations Markings ANSI/UL 698 Industrial control equipment for use in hazardous (classified) locations.
ANSI/UL 781 Portable electric lighting units for use in hazardous (classified) locations.
Class I, II & III, Division 1 & 2 (U.S. & Canada) -- This marking would include:
Class(es), Division(s), Gas/Dust Group(s), Temperature Code. Example: Class I, Division 1, Groups C & D, T4A. ANSI/UL 783 Electric flashlights and lanterns for use in hazardous (classified) locations.
ANSI/UL 823 Electric heaters for use in hazardous (classified) locations.
Class I, Zone 0, 1 & 2 (U.S. & Canada) -- This marking would include: ANSI/UL 844 Electric lighting fixtures for use in hazardous (classified) locations.
Method A: For Zone Listings based on UL 2279 or the CSA-E79 Series Class, Zone(s), Ex, Protection Method(s), Gas Group, Temporary ANSI/UL 877 Circuit breakers and circuit-breaker enclosures for use in hazardous (classified) locations.
Code. Example: Class I, Zone 1, Ex de IIB T4. ANSI/UL 886 Outlet boxes and fittings for use in hazardous (classified) locations.
ANSI/UL 894 Switches for use in hazardous (classified) locations.
Method B: For Zone Listings based on UL or CSA Division Certification Documents Class, Zone(s), Gas Group, Temperature Code. ANSI/UL 913 Intrinsically safe apparatus and associated apparatus for use in Class I, II and III, Division I, hazardous (classified)
Example: Class I, Zone 1, Group IIB T4. locations.
ANSI/UL 1002 Electrically operated valves for use in hazardous (classified) locations.
Note: For U.S. Zone Listings based on UL 2279, Article 505 of the 1999 NEC requires that the "Ex" element of the marking string shall ANSI/UL 1010 Receptacle-plug combinations for use in hazardous (classified) locations.
read "AEx."
ANSI/UL 1067 Electrically conductive equipment and materials for use in flammable anesthetizing locations.
ANSI/UL 1203 Explosion-proof and dust-ignition-proof electrical equipment for use in hazardous (classified) locations.
Note: For Canadian Zone Listings based on the CSA-E79 Series, the "Class" and "Zone" elements of the marking string are optional.
ANSI/UL 1207 Sewage pumps for use in hazardous (classified) locations.
Zone 0, 1 & 2 (IEC only) -- This marking would include: UL 1604 Electrical equipment for use in Class I and II, Division 2, and Class III hazardous (classified) locations.
Ex, Protection Method(s), Gas Group, Temperature Code. Example: Ex de IIB T4. UL 2208 Solvent distillation units.
UL 2225 Metal-clad cables and cable-sealing fittings for use in hazardous (classified) locations.
Zone 0, 1 & 2 (Europe only) -- This marking would include: ANSI/UL 2279 Electrical equipment for use in Class I, Zone 0, 1 and 2 hazardous (classified) locations.
EEX, Protection Method(s), Gas Group, Temperature Code. Example: EEX de IIB T4.
132 133
Courtesy of Steven Engineering, Inc. ! 230 Ryan Way, South San Francisco, CA 94080-6370 ! Main Office: (650) 588-9200 ! Outside Local Area: (800) 258-9200 ! www.stevenengineering.com
Glossary of Terms 502.969.8000 Leverless Limit Switches
Reference Material
Ambient Temperature Digital Signal
The temperature for a medium, such as gas or liquid, surrounding an object. A signal in which the data is transmitted or represented by a series of discrete pulses or steps of constant amplitude.
134 135
Courtesy of Steven Engineering, Inc. ! 230 Ryan Way, South San Francisco, CA 94080-6370 ! Main Office: (650) 588-9200 ! Outside Local Area: (800) 258-9200 ! www.stevenengineering.com
Glossary of Terms 502.969.8000 Leverless Limit Switches
Reference Material
MSHA Reset (Differential) (Hysteresis)
Abbreviation for Mine Safety Heath Administration The distance which a target must move from the sensing point in order to allow the switch to reset.
NEC RTV
National Electric Code. Abbreviation for Room Temperature Vulcanizing.
Non-incendive SAA
Non-incendive equipment contain components that do not allow arcs or sparks to ignite concentrations of flammable gases. One method of Abbreviation for Standards Association of Australia.
producing a non-incendive switch is by sealing off the contact chamber with a hermetic seal so that a flammable gas cannot enter into the
arcing / sparking area of the switch. SAE
Abbreviation for Society of Automotive Engineers.
Normally Closed Circuit
Circuit which passes current when the GO Switch is not actuated. Symbolized by N/C. Same Polarity Only
On DMDB switches the like terminals must be wired with the same voltage polarity.
Normally Open Circuit
Circuit which passes current when the GO Switch is actuated. Symbolized by N/O. Sensing Area
That location marked on a GO Switch that is most sensitive to a ferrous or magnetic target.
Operating Distance
A distance at which the target under its axial or lateral approaching causes the switch to operate. An axial operating distance is a distance Sensing Distance Range
between an operating point and the sensing face; a lateral operating distance is a distance between an operating point and the reference axis. Maximum gap between switch and target when the switch first operates; the trip point.
Repeatability
Ability to perform the same task operating parameters, consistently, time after time.
136 137
Courtesy of Steven Engineering, Inc. ! 230 Ryan Way, South San Francisco, CA 94080-6370 ! Main Office: (650) 588-9200 ! Outside Local Area: (800) 258-9200 ! www.stevenengineering.com
Conversion Charts 502.969.8000 Leverless Limit Switches
Reference Material
Conversion Factors Fraction/Decimal/Millimeter Conversion Chart Basic Contact Forms
PSI x 27.71 = in. H2O Inches Decimals Millimeters inches Decimals Millimeters Temperature Conversion A J
PSI x 2.036 = in. Hg 1/64 0.0157 0.40 33/64 0.5156 13.10 Make Make,
PSI x 703.1 = mm H2O Fahrenheit Centigrade SPST-NO Make,
PSI x 51.75 = mm Hg 1/32 0.0313 0.80 17/32 0.5312 13.49
F C Break
PSI x .0703 = kg/cm2 3/64 0.0469 1.19 35/64 0.5469 13.89
-40 -40.00
PSI x .0689 = bar 1/16 0.0625 1.59 9/16 0.5625 14.29 B K
PSI x 68.95 = mbar -30 -34.44
5/64 0.0781 1.98 37/64 0.5781 14.68 Break Center off
PSI x 6895 = Pa -20 -28.89
3/32 0.0938 2.38 19/32 0.5938 15.08
SPST-NC SPDT
PSI x 6.895 = kPa -10 -23.33
7/64 0.1094 2.78 39/64 0.6094 15.48 0 -17.78
Note: conversion factors are rounded. 1/8 0.125 3.18 5/8 0.6250 15.88 10 -12.22 C L
9/64 0.1406 3.57 41/64 0.6406 16.27 Break, Make Break,
20 -6.67
Transfer Make,
5/32 0.1563 3.97 21/32 0.6563 16.67 30 -1.11
Pressure* SPDT Make
11/64 0.1719 4.37 43/64 0.6719 17.07 40 4.44
BAR ATM. Kg cm2 P.S.I.
3/16 0.1875 4.76 11/16 0.6875 17.46 50 10.00 D U
1 1 1 15
13/64 0.2031 5.52 45/64 0.7031 17.86 60 15.56 Make, Break Double make
2 2 2 30
7/32 0.2188 5.56 23/32 0.7188 18.26 70 21.11 (Continuity Contact on
3 3 3 45 Transfer) arm
15/64 0.2344 5.95 47/64 0.7344 18.65 80 26.67
5 5 5 75
1/4 0.2500 6.35 3/4 0.7500 19.05 90 32.22 E V
10 10 10 150
100 37.78 Break, Make, Double break
20 20 20 300 17/64 0.2656 6.75 49/64 0.7656 19.45
Break Contact on
30 30 30 450 110 43.33
9/32 0.2813 7.14 25/32 0.7813 19.84 arm
50 50 50 750 120 48.89
19/64 0.2969 7.54 51/64 0.7969 20.24
100 100 100 1500 130 54.44 F W
5/16 0.3125 7.94 13/16 0.8125 20.64
200 200 200 3000 140 60.00 Make, Double break,
21/64 0.3281 8.33 53/64 0.8281 21.03 Make Double make,
300 300 300 4500 150 65.56
11/32 0.3438 8.73 27/32 0.8348 21.43 Contact on arm
500 500 500 7500 160 71.11
23/64 0.3594 9.13 55/64 0.8594 21.83
1000 1000 1000 15000 170 76.67 G X
3/8 0.3750 9.53 7/8 0.8750 22.23 Double
180 82.22 Break,
25/64 0.3906 9.92 57/64 0.8906 22.62 190 87.78 Make make
Pressure
Standard Atmosphere Pressure is 15 psi (14.7) 13/32 0.4063 10.32 29/32 0.9063 23.02 200 93.33
15 Pounds = 1 Atmosphere
Square Inch 27/64 0.4219 10.72 59/64 0.9219 23.42 250 121.11
H Y
Bar is a Unit of Pressure Equal to 1 Atmosphere or 7/16 0.4375 11.11 15/16 0.9375 23.81 275 135.00 Break,
Approx. 15 Pounds Double
Square Inch 29/64 0.4531 11.51 61/64 0.9531 24.21 300 148.89 Break, break
*Conversions are approximate for convenience of users. 15/32 0.4688 11.91 31/32 0.9688 24.61 325 162.78 Make
31/64 0.4844 12.30 63/64 0.9844 25.00 350 176.67
I Z
1/2 0.5000 12.70 1 1 25.40 375 190.55
Make, Double make
400 204.44 Double break
Break,
1 mm = .040" .001" = .0254 mm 425 218.33 SPDT-DB
Make
450 232.22
475 246.11
500 260.00
138 139
Courtesy of Steven Engineering, Inc. ! 230 Ryan Way, South San Francisco, CA 94080-6370 ! Main Office: (650) 588-9200 ! Outside Local Area: (800) 258-9200 ! www.stevenengineering.com