Inband Huawei PDF
Inband Huawei PDF
DCN
Firewall
Managed network
NOTE
The U2000 uses the dedicated communication channels to transmit the management information to the
managed networks.
Context
The configuration of an inband DCN includes the following contents:
2.14.4.1 Setting NE Communication Parameters
When configuring the IP Over DCC communication, you need to set the parameters including
IP, Subnet Mask, Gateway IP, Extended ID, and Connection Mode for the NE.
2.14.4.2 Setting the VLAN ID and Bandwidth Used by an Inband DCN
The RTN equipment communicates with the U2000 in inband DCN mode. The network
management information is transmitted with the service information, and the equipment marks
the management information with a default VLAN ID. You can adjust the bandwidth of an
inband DCN.
2.14.4.3 Setting the U2000 Access Parameters
In the case of the traditional DCN network, the equipment accesses to the U2000 through the
SCC board. The RTN equipment can also access to the U2000 through the network interface of
the Ethernet board. When the RTN equipment accesses to the U2000 by using the network
interface of the Ethernet board, set the access parameters of the Ethernet board for the equipment
to communicate with the U2000.
2.14.4.4 Enabling the Port DCN
The NM information can be transported in the inband DCN only when the DCN access function
is enabled for the ports at two ends of the link.
2.14.4.5 Enabling the Tunnel DCN
The NM information can be transported in the IP/GRE Tunnel only when the DCN access
function is enabled for the IP/GRE tunnel.
Prerequisite
l You must be an NM user with "NE maintainer" authority or higher.
l The IP GNE must be created.
Context
CAUTION
The operation of modifying the NE communication parameters interrupts the communication
and affects the services.
Procedure
Step 1 In the NE Explorer, select an NE and choose Communication > Communication
Parameters from the Function Tree.
Step 2 Set the NE communication parameters, including IP, Subnet Mask, Gateway IP, Extended
ID, NSAP Address.
Step 3 Click Apply and then click OK in the Warning dialog box that appears twice. in the Warning
dialog box that appears twice. Click Close in the Operation Result dialog box.
----End
Prerequisite
You must be an NM user with "NE operator" authority or higher.
Context
l If the default VLAN ID of the DCN conflicts with the VLAN ID used by the service,
manually modify the VLAN ID of the DCN to ensure that the networkwide DCN uses the
same VLAN ID.
l If the DCN packets do not use all the available bandwidth, the idle bandwidth can be shared
with the service packets.
l It is recommended to perform the modification on non-gateway NEs and then the gateway
NE, to prevent the non-gateway NEs from being unreachable to the U2000.
Procedure
Step 1 In the NE Explorer, select an NE and choose Communication > DCN Management from the
Function Tree.
----End
Prerequisite
You must be an NM user with "NE operator" authority or higher.
Context
NOTE
l You need to set the parameters only when the U2000 accesses the equipment by using an Ethernet
service board.
l By default, the Enabled Status is Disabled.
CAUTION
In the case of the OptiX RTN equipment, when the DCN port is interconnected to the U2000,
the IP address of the U2000 and the IP address of the NNI should not be set to the same subnet.
This operation may affect the communication between the U2000 and NEs.
Procedure
Step 1 In the NE Explorer, select an NE and choose Communication > DCN Management from the
Function Tree.
Step 2 Click the Access Control tab, and enter parameters.
Step 3 Click Apply.
----End
Prerequisite
You must be an NM user with "NE operator" authority or higher.
Procedure
Step 1 In the NE Explorer, select an NE and choose Communication > DCN Management from the
Function Tree.
Step 2 Click the Port Settings tab.
Step 3 Select different interface types, and set the corresponding attributes.
NOTE
----End
Prerequisite
You must be an NM user with "NE operator" authority or higher.
Procedure
Step 1 In the NE Explorer, select an NE and choose Communication > DCN Management from the
Function Tree.
Step 2 Click the Tunnel Settings tab.
Step 3 Select different tunnel types, and set the corresponding attributes.
Step 4 Click Apply.
----End