You are on page 1of 4

MODERN TECHNOLOGY

FOR EVERYONE
WEB BASED
D-300
The D-300 is a cost
effective comprehensive
genset controller ready
for internet monitoring.
Dung may
FEATURES COMMUNICATION
Diesel and gas genset support Battery back-up real time clock 4-band GPRS modem (optional)
400Hz operation support Idle speed control USB Device
400 event logs, full snapshot Battery charge run enabled RS-232 (2400-57600baud)
All parameters front panel Combat mode support J1939-CANBUS
editable Multiple nominal conditions Geo-locating through GSM
3 level configuration password Contactor & MCB drive GPS support (RS-232)
128x64 graphical LCD display 4 quadrant genset power Internet Central Monitoring
Downloadable languages counters SMS message sending
Waveform display of V & I Mains power counters E-mail sending
Harmonic analysis of V & I Fuel filling counter Free PC software: Rainbow Plus
16Amp MCB & GCB outputs Fuel consumption counter Modbus RTU
8 configurable digital inputs Modem diagnostics display
6 configurable digital outputs Configurable through USB,
3 configurable analog inputs RS-232 and GPRS FUNCTIONALITIES
Both CANBUS-J1939 & MPU Free configuration program AMF unit
3 configurable service alarms Allows SMS controls ATS unit
Multiple automatic exerciser Ready for central monitoring Remote start controller
Weekly operation schedule Mobile genset support Manual start controller
Dual mutual standby with Automatic GSM geo-location Engine controller
equal aging of gensets GPS connectivity (RS232) Remote display panel
Manual speed fine adjust on Easy USB firmware upgrade
selected ECUs IP65 rating with optional gasket
Automatic fuel pump control TOPOLOGIES
Disable protections feature MEASUREMENTS 3 ph 4 w, star & delta
Excess power protection
Mains & genset PN/PP voltages 3 ph 3 w, 2 CTs
Reverse power protection
Mains & genset frequency 2 ph 3 w
Overload IDMT protection
Mains & genset phase currents 1 phase 2 wires
Load shedding, dummy load
Mains & genset neutral currents
Multiple load management
Mains & genset, phase & total,
Current unbalance protection
kW, kVA, kVAr, pf
Voltage unbalance protection
Engine speed
Fuel filling & fuel theft alarms
Battery voltage

Loi tai
COMMUNICATIONS

USB

ho

TECHNICAL SPECIFICATIONS
Alternator voltage: 0 to 300 V-AC (Ph-N) Maximum humidity: 95% non-condensing.
Alternator frequency: 0-600 Hz. IP Protection: IP65 from front panel, IP30 from the rear
Mains voltage: 0 to 300 V-AC (Ph-N) (with gasket)
Mains frequency: 0-600 Hz. Dimensions: 172 x 134 x 46mm (WxHxD)
Topology: 1-2-3 phases, with or without neutral Panel Cut-out Dimensions: 151 x 111 mm minimum.
DC Supply Range: 8.0 to 36.0 V-DC. Weight: 300 g (approx.)
V-A-cos Accuracy: 0.5% + 1 digit Case Material: High Temperature, non-flammable
kW-kVA-kVAr Accuracy: 1.0% + 1 digit ABS/PC
Current consumption: 500 mA-DC max @ 12V-DC Installation: Flat surface mounting on a Type 1 enclosure.
Current Inputs: from current transformers. ../5A. Rear retaining plastic brackets.
Digital inputs: input voltage 0 to 36 V-DC.
Analog input range: 0-5000 ohms. CONFORMITY
Mains and genset contactor outputs: 16Amps@250V
DC Outputs: Protected mosfet semiconductor outputs, EU Directives Conformity
rated 1Amp@28V-DC -2006/95/EC (low voltage)
Cranking dropouts: survives 0V for 100ms. -2004/108/EC (electro-magnetic compatibility)
Magnetic pickup voltage: 0.5 to 50Vpk. Norms of reference:
Magnetic pickup frequency: 0 to 20000 Hz. EN 61010 (safety requirements)
Charge Alternator Excitation: 2W. EN 61326 (EMC requirements)
Display Screen: 2.9, 128x64 pixels UL & CSA Compatibility:
USB Device: USB 2.0 Full speed -UL 6200, Controls for Stationary Engine Driven
RS-232 Port: selectable baud rate (2400-57600baud) Assemblies (Certificate # - 20140725-E314374)
Operating temperature: -20C to 70C (-4 to +158 F) -CAN/CSA C22.2 No. 14-13 Industrial Control
Storage temperature: -40C to 80C (-40 to +176F) Equipment
WAVEFORM DISPLAY & HARMONIC ANALYSIS

Waveform Display Graphical Harmonics Digital Harmonics Display


o

RAINBOW PLUS PROGRAM

O
Scada Harmonic analysis & Waveform

RAINBOW SCADA CENTRAL MONITORING

Fleet Display on Map, online monitoring Smartphone Support

Real time monitoring


+
BATTERY
12/24V

L3
L2
L1

N
Fuse

S
GEN-C 51
1 BAT +
GEN-L1 52 FUSE

RS-232
2 BAT -
Crank 53

Starter Motor
3 OUT 1
Fuel G-L2 54 FUSE
4 OUT 2

SIM
Alarm 55
5 OUT 3

CARD

GSM
Preheat GEN-L3 56 FUSE
6 OUT 4
D+/WL Charge Alternator 57
7 CHG
ALTERNATOR

ANTENNA
Oil Press. Sender GEN-N 58
8 SND 1
Temp. Sender
9 SND 2
GC

!
Fuel Lev. Sender
10 SND 3
Sender Gnd *1 I 1+ 59
11 SGND
I 1- 60
I 2+ 61
Low Oil Pressure I 2- 62
12 IN 1
High Temp I 3+ 63

0.2 to 6.0 Aac


13 IN 2
LOAD

Emergency Stop I 3- 64

300Vac, 0-600 Hz
14 IN 3

*1 Connect
L1 L2 L3 N

Low Coolant Level


15 IN 4

8 to 36Vdc, 500mA max


Spare Input 1
16 IN 5
MC

Spare Input 2
TYPICAL CONNECTIONS

17 IN 6 MAINS-N 65
Spare Input 3 66
18 IN 7
Spare Input 4 MAINS-L3 67 FUSE
19 IN 8

*2

*2 Ground from one end only.


20 MPU+ 68
FUSE

MPU
21 MPU- / PGND MAINS-L2 69
J1939-H CANH 70
22
J1939-L CANL MAINS-L1 71 FUSE
23

*2
MAINS-C 72

USB

To ECU

to the engine body, close to the senders.


N
MAINS

L3
L2
L1

Dung may

You might also like