HUAWEI TECHNOLOGIES CO., LTD. Page 1 1. Setting of IP address on your Laptop
1.1 Right Click on
icon of Local Area Connection (LAN) 1.3 Go to Internet Protocol (TCP/IP) then click Properties 1.2 Click on Properties
HUAWEI TECHNOLOGIES CO., LTD. Page 2
1.4 Type in IP Address then click on OK
ALWAYS USE THE FOLLOWING:
IP Address: 129.9.0.99 Subnet mask: 255.255.0.0
(No need to filed-up the Default gateway
and DNS)
HUAWEI TECHNOLOGIES CO., LTD. Page 3
2. Open the U2000 Web LCT application (pre-installed) 3. Type in your user name and password to Login
User Name: admin
Password: admin
HUAWEI TECHNOLOGIES CO., LTD. Page 4
4. To Search for a NE (Network Element), click NE Search
4.1 Click on NE SEARCH first
before you Add NE
HUAWEI TECHNOLOGIES CO., LTD. Page 5
4.2 Click on SEARCH Note: Domain is automatically set (no need to input
HUAWEI TECHNOLOGIES CO., LTD. Page 6
Web LCT will search and detect available NEs
4.3 Available NE will appear
4.4 Click Add NE
HUAWEI TECHNOLOGIES CO., LTD. Page 7
4.6 After pressing OK, all available NE will be added on the screen (Communication Status will be NORMAL)
4.5 Then click on OK
HUAWEI TECHNOLOGIES CO., LTD. Page 8
5. To Login into the NE
5.1 Highlight the NE you want to login
5.2 Click on NE Login
HUAWEI TECHNOLOGIES CO., LTD. Page 9
5.3 Enter Password: password
5.4 Then press Apply and OK
HUAWEI TECHNOLOGIES CO., LTD. Page 10
6. To configure the NE, check if the Login Status then click on NE Explorer
Status will be already Logged in
6.1 Highlight the NE you want to configure
6.2 Click on NE Explorer
HUAWEI TECHNOLOGIES CO., LTD. Page 11
7. Web LCT will automatically detect the available board/card on the Slot Layout (with color ) 8. To install the cards, right click on the board then pressed ADD
Note: PIU, FAN and
CSH card will automatically running installed. Also slot 23 and 25 for ODU will not detect until you finished add the IFU2 boards.
8.1 Click add Physical
Boards
HUAWEI TECHNOLOGIES CO., LTD. Page 12
8.3 Right click the ODU board then click the add physical board
8.2 After you add all the
physical boards, slot 23 and 25 for ODU board will appear.
HUAWEI TECHNOLOGIES CO., LTD. Page 13
9. Configuring NE attribute Site Name and Modifying NE
9.1 Highlight NE name
9.3 Double click box under
NAME and type SITE NAME. Then click apply and query. 9.2 Highlight NE attributes
HUAWEI TECHNOLOGIES CO., LTD. Page 14
9.4 Click Modify NE ID and a dialog box will appear.
9.5 Type Site ID based on plan
assigned by TNP. Then click OK NOTE: ID is a unique number.
11.5 Double Click the 11.6 Double Click the box 11.4 Double Click the box of Manually box of IF Channel of E1 Capacity and change Specified Module and the capacity according to Band and change the change the module band according to the the plan according to the plan plan
11.7 Click Apply then
Query
HUAWEI TECHNOLOGIES CO., LTD. Page 19
12. Configuring Transmit Frequency and Transmit Power
12. 1 Highlight 23-ODU
12.3 Double click the
box of transmit 12.4 Click apply then frequency and type the query frequency according to link budget given by TNP 12.2 Highlight ODU interface
HUAWEI TECHNOLOGIES CO., LTD. Page 20
12.5 click the power attributes
12.6 Double click the box of transmit power and
type the power according to link budget given by TNP 12.7 Click apply and query
HUAWEI TECHNOLOGIES CO., LTD. Page 21
13. Configuring Cross-Connection
13.1 Highlight NE name
13.2 Highlight cross connection
configuration
13.3 Click New
HUAWEI TECHNOLOGIES CO., LTD. Page 22
HUAWEI TECHNOLOGIES CO., LTD. Page 23 Thank You www.huawei.com