PLANNING HOLDER BANDUL IMPACT CHARPY

TESTER 8041A WITH CASTING METHOD

Name Of Student : DIANA SEKAR SARI


NRP : 2110 030 100
Department : D3 Teknik Mesin FTI ITS
Consellor Lecturer : Ir. Eddy Widiyono, MSc.

Abstract
Holder damage pendulum impact testing machine in
laboratory sciences campus workshop materials D3 Mechanical
Engineering FTI quite tiring ITS lab operator at the time of
impact for research or testing. In addition, the automation system
in which the motor is still good to be not functioning optimally.
Problems that can be raised in this discussion is how to
design holder with a pendulum impact test machine noticed the
pattern dimensions and tolerance, ideal channel system and order
prints for casting process based on existing theories.
After calculation based on the theory that there is a
pattern then obtained planning and channel system with size
pattern holder Dimensions Length 101 mm, Width 54.5 mm,
163.5 mm Height planned pattern type material is wood jelutung.
Jjenis pattern in use is the single pattern. For the mold making
process needs to be created shape and dimensions of the duct
system with a diameter (d) is 13 mm down the channel. As for the
height (h) channel down is 5d, so the height of 65 mm was
obtained. The slope of the descending channel angle 90.02. Pour
the cup length 130 mm, width 52 mm cup Pour, pour the cup side

3
shallowest depth 65 mm, 58.5 mm inner side, high channel
diverter is 12.88 mm, while for ingate diameter is 14,11 mm.
Riser made with a diameter of 40mm and height of 60mm and are
used here blind enhancer. Molding sand in use is the type of
silica. The time is 64.46 secon castings. Ballast is 68.5 kgf. Mold
wall thickness is 40mm. Cup dimensions 390mm x 356mm x 183
mm. Dimensions Drag x.356mm 390mm x 202mm.
Key word: Holder bandul, gatyng system, pattern.