After check and remove all the carrier inconsistencies the data traffic balance hasnt
been achieved yet.
Classification the affected sites. It was found that only the sites with DC feature suffer from
data traffic unbalancing among the carriers.
Solution
Disable DRD HSPA+ cell capability ranking HSPAPlusSatisSwitch (HSPA+ Capability Switch)
Parameter ID HSPAPlusSatisSwitch
Impact on If this parameter is set to ON, UEs can access an HSPA+ cell with higher
Radio HSPA+ technical compliance. However, with the increase of HSPA+ UEs,
Network the load of the HSPA+ cell increases and HSPA+ user experience
Performance deteriorates when the cell is overloaded. If this parameter is set to OFF, the
HSPA+ technical compliance of cells is not considered in the DRD process.
Therefore, higher HSPA+ technologies cannot be used, which affects user
experience.
Suggestion
We suggested to rollout the action over all the network while monitoring as the action gain was
and
very good and achieve the customer requirement.
Summary