You are on page 1of 3

pile

Soil Details Results


g 19 kN/m Unit weight of soil (gamma) 10m long Circular pile
c' (or su) 150 kN/m For undrained soils use phi' = 0 2.31m diameter
f 0 deg Angle of friction (phi') Undrained Analysis (Phi=0)
a 0.4 Adhesion Factor
Ks 0 Coefficient of Earth Pressure Base Resistance
d 0 deg Angle of friction between pile and soil 5658 kN
Water Table 20 m Depth to Water Table Shaft Resistance
4354 kN
Pile Details Total ultimate resistance
10012 kN
Shape ci sq=Square, ci=Circular
Circular Allowable Load
Diameter 2.31 m Diameter of pile 5006 kN
Toe Depth 10 m Depth to base of pile
Overall factor of safety
Load 5000 kN Applied load - includes weight of pile 2.00
OK
Safety Factors Actual Load <=Allowable
Base 2.0 Shaft 2.0 Pile Volume
41.9 m

Page 1
pile

Pile Capacity Calculations


Bearing Capacity Factors
Nq= Err:508 (Berezantzev et al)
nalysis (Phi=0) Nc= 9.00

Overburden stress
sigma_b= 190.00 (at Base)
sigma_s= 95.00 (average for Shaft)

e resistance Base Bearing Capacity


(Base + Shaft) qu=suNc (for undrained analysis)
qu=cNc+sigma_b*Nq (for drained analysis)

qu = 1350 kN/m

Shaft skin friction


fs=alpha.su (for undrained analysis)
fs=c'+Ks.sigma_s.tan(delta) (for drained analysis)
<=Allowable
fs= 60.0 kN/m

Page 2
pile

e Capacity Calculations
Depth/Width= 4.33

Areas
Base (Ab) = 4.19 m
Shaft (As) = 72.6 m

Base Resistance

Qb=qu*Ab

Qb= 5658 kN

Shaft Resistance

Qs=fs*As

Qs= 4354 kN

Page 3

You might also like