Professional Documents
Culture Documents
GHV30/15SV10F1106T: Operating Data
GHV30/15SV10F1106T: Operating Data
Operating data
1 Pumpe ty pe Single-/Multi-pump set Fluid Water
2 No. of pumps / Reserv e 3 / 1 Operating temperature t A C 4
3 Nominal f low m/h 37.4 pH-v alue at t A 7
4 Nominal head m 94.6 Density at t A kg/dm 1
5 Static head m 0 Kin. v iscosity at t A mm/s 1.569
6 Inlet pressure bar 0.098 Vapor pressure at t A bar 0.00789
7 Env ironmental temperature C 4 Solids 0
8 Av ailable sy stem NPSH m 0 Altitude m 1000
Pump data
9 Pump designation Max. mm 105
10 GHV30/15SV10F1106T Impeller designed mm 105
11 Design Electrical booster set Min. mm 105
12 Make Lowara Nominal m/h 39.3 ( 19.6 )
13 Flow Max- m/h 24
14 Speed 1/min 2900 Min- m/h
15 Number of stages 10 Nominal m 104.2
16 Max. working pressure bar 14.6 Head at Qmax m 77.1
17 Head H(Q=0) m 150 at Qmin m 147.7
18 Weight kg 400 Shaf t power kW 15.9 ( 7.9 )
19 Weight data include external package Max. shaf t power kW 16.2
20 Ef f iciency % 70.11
21 NPSH 3% m 2.1
Materials
22 Pump Motor data
23 Pump body AISI 304 Manuf acturer Lowara Electric v oltage 400 V
24 Pump outer sleev e AISI 304 Specif ic design 3 phase IE2 motors (high ef f iciency )
25 Manif olds AISI 304 Ty pe PLM160RB5/3110 Electric current 20.3 A
26 On-of f v alv es Nickel-plated brass Rated power 11 kW Degree of protection IP 55
27 Non-return v alv es Painted cast iron with stainless steel f laps Speed 2925 1/min Insulation class F
28 Pressure switches Chrome plated zinc alloy Frame size 160 Color RAL 5010
29 Pressure transmitters AISI 316 Weight 0 kg
30 Nipples/caps/plugs/f langes Galv anized steel Frequency conv erter data
31 Bracket Painted steel Hy drov ar
32
Standard options
33 Non return v alv e in deliv ery side
34 High pressure protection Without high pressure protection
35 Pipes ov ersize Standard
37 Suction side Standard
36 Panel protection degree IP 55
38 Voltometer Without v oltometer
39 Pressure gauge
40 Analogue dev ices Standard
41 Minimum pressure switch control Without pressure switch on suction side f or dry -running protection
42 No suction manif old Standard
43 Check v alv e Standard
44 Electrical panel Standard
45 :
46
47
Page 1 / 3
GHV30/15SV10F1106T
Company Customer Date 2015-01-29
Contact Contact Item no.
Phone number Phone number Project
Email Email Project no.
1.5
1.0
0.5
12
10
6
39.3 m/h
4
0 2 4 6 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 40 42 44 46 48 50 52 [m/h]
GHV30/15SV10F1106T
Company Customer Date 2015-01-29
Contact Contact Item no.
Phone number Phone number Project
Email Email Project no.
"PLEASE NOTE:
The drawing refers the standard basic version;
For pressure booster sets with special configurations the drawing must be requested to the customer service."
Dimensions mm
A 353 H3 973 Weight
B 397.5
C 960.5 400 kg
D 1084
DNA 100
DNM 80
H 170
H1 764.5
H2 1593
Page 3 / 3